• Title/Summary/Keyword: Archimedes Number

Search Result 14, Processing Time 0.019 seconds

Evaluation of Hydrodynamic Behavior in Horizontal Settling Basin with Archimedes number (Archimedes number를 이용한 장방형 침전지내 수리흐름 평가에 관한 연구)

  • Park, No-Suk;Lee, Sanguk
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.6
    • /
    • pp.865-870
    • /
    • 2009
  • In this study, the adequacy of Reynolds numbers and Froude numbers derived from about sixty domestic water treatment plants (WTPs) were analyzed in order to estimate the characteristics of hydraulic behavior within the rectangular shaped sedimentation basins used widely. From the results of analysis, most of domestic WTPs have satisfied the criteria regulated as that Reynolds number should less than 1,000(dimensionless). On the other hand, they have not been able to satisfy the Froude number criteria, which should be higher than $1.0{\times}10^{-6}$. The reasons why most of domestic WTPs could not satisfy the criteria are that its criteria basis has been not only inadequate, but also the concept of external flow occurred around a settling particle has been ignored. Accordingly, this study proved the feasibility of Archimedes number, which indicates the ratio between particle Reynolds number and Froude number, to evaluate the hydraulic efficiency and its function of scale factor.

Topological Optimization of Heat Dissipating Structure with Forced Convection (강제 대류를 통한 열소산 구조물의 위상최적화)

  • Yoon, Gil-Ho
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.408-409
    • /
    • 2008
  • This paper presents a new development for topology optimization of heat-dissipating structure with forced convection. To cool down electric devices or machines, two types of convection models have been widely used: Natural convection model with a large Archimedes number and Forced convection with a small Archimedes number. Nowadays, many engineering application areas such as electrochemical conversion device or fuel cell devices adopt the forced convection to transfer generated heat. Therefore, to our knowledge, it becomes an important issue to design flow channels inside which generated heat transfer. Thus, this paper studies optimal topological designs considering fluid-heat interaction. To consider the effect of the advection in the heat transfer problem, the incompressible Navier-stokes equation is solved. This paper numerically studies the coupling phenomena and presents optimal channel design considering forced convection.

  • PDF

Analysis of Jet-drop Distance from the Multi Opening Slots of Forced-ventilation Broiler House (강제 환기식 육계사 다중 입기 슬롯에서의 입기류 도달거리 분석)

  • Kwon, Kyeong-Seok;Ha, Tae-Hwan;Lee, In-Bok;Hong, Se-Woon;Seo, Il-Hwan;Jessie, P. Bitog
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.54 no.2
    • /
    • pp.55-65
    • /
    • 2012
  • In the winter season, when the ventilation system is operating, the fresh cold air from the slot-type openings of broiler house which directly reached the animal zone can cause various problems such as thermal stress, decreasing of feed and water consumption, occurrence of respiratory disease, and etc. Therefore it is very important to control the trajectory of aero-flow from the slot openings to induce an efficient thermal heat change. Jet-drop distance model was proposed to predict and control the jet-trajectory. However their study was restricted due to the small scaled model and difficulties of measuring the Jet-drop distance. In this study, CFD was applied to analyze qualitatively and quantitatively the jet-drop distance in a real broiler house. The various variables were considered such as installed slot-angle, designed ventilation rate, and the outdoor ambient temperature. From the present study, two linear-regression models using the Jet-drop factor and corrected Archimedes number, and their R-squared values 0.744 and 0.736, respectively, were used. From this study, the applicability of CFD on the analysis of Jet-drop distance model was confirmed.

Design of the 1/8 Scaled HU-KINS Based on the Scaling Laws for the Experimental Investigation of Thermal-Hydraulic Effect of CANDU-6 Moderator (CANDU-6 원자로 감속재 열수력 개별영향실험을 위한 축소화 기법에 따른 1/8 축소형 HU-KINS 설계)

  • Lee, Jae-Young;Kim, Man-Woong;Kim, Nam-Seok
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.9 s.252
    • /
    • pp.825-833
    • /
    • 2006
  • To investigate the moderator coolability for CANDU-6 reactors, a test facility (HU-KINS) has been manufactured as a 1/8 scaled-down of a calandria tank. In the design of the test facility, a scaling law was developed in such a way to consider the thermal-hydraulic characteristics of a CANDU-6 moderator. The proposed scaling law takes into consideration of the energy conservation, the dynamic similitude such as dimensionless numbers, Archimedes number (Ar) and Reynolds number (Re), and thermal-hydraulic properties similitude. Using this proposed scaling law, the thermal-hydraulic scaling analyses of similar test facilities such as the SPEL (1/10 scale) and the STERN (1/4 scale), have been identified. As a result, in the case of the SPEL, while the energy conservation is well defined, the similarities of Ar and the heat density are not well considered. As for the similarity of the STERN, while both the energy conservation and the characteristics of Ar are well defined, the heat density is not. In the meanwhile, the HU-KINS test facility with 1/8 length scaled-down is well similitude in compliance with all similarities of the energy conservation, the fluid dynamics and thermal-hydraulic properties. To verify the adequacy of the similarities in terms of thermal-hydraulics, a computational fluid dynamic (CFD) analysis has been conducted using the CFX-5 code. As the results of the CFD analyses, the predicted flow patterns and variation of axial properties inside the calandria tank are well consistant with those of previous studies performed with FLUENT and this implies that the present scaling method is acceptable.

Structural Optimization of Heat Dissipating Structure with Forced Convection (강제 대류가 있는 열소산 구조물의 구조최적설계)

  • Yoon, Gil-Ho;Kang, Nam-Cheol
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.13 no.1
    • /
    • pp.51-57
    • /
    • 2009
  • In this study, a new topology optimization method is developed to design heat-dissipating structure with forced convection. To cool down electrical devices or mechanical machines, two types of convection models have been widely used: the natural convection model with a large Archimedes number and the forced convection with a small Archimedes number. In these days, lots of engineering application areas such as electrochemical conversion devices (Fuel cell) or rocket propulsion engines adopt the forced convection to dissipate the generated heat. Therefore, to our knowledge, it becomes an important issue to design flow channels inside which the generated heat dissipate. Thus, this paper studies optimal topological designs considering fluid-heat interactions. To consider the effect of the advection in the heat transfer problem, the incompressible Navier-stokes equation is solved. This paper numerically studies the coupling phenomena and presents optimal channel design considering forced convection.

Effect of supply air temperature and airflow rate on ventilation effectiveness in an underfloor air conditioning space (바닥취출 공조공간에서 급기온도 및 급기풍속이 환기효율에 미치는 영향)

  • 정광섭;한화택;홍승재
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.5
    • /
    • pp.640-648
    • /
    • 1998
  • A numerical study has been conducted to investigate the effect of inflow supply air temperature and velocity on ventilation effectiveness in an underfloor air conditioning space. A low Reynolds number k-$\varepsilon$ model is implemented to calculate steady state turbulent velocity distributions. A step-down injection method is used to calculate local and room mean ages from transient concentrations based on the concept of the age of air. Results show that there is a significant effect of Archimedes number on ventilation effectiveness especially for cooling conditions. Reynolds number shows relatively minor effect on velocity distribution and ventilation effectiveness especially for isothermal and heating conditions. It can be concluded that underfloor air conditioning system provides good ventilation characteristics for cooling conditions because of temperature stratification in the space.

  • PDF

A Study on the Performance Characteristics of a Disk-type Drag Pump (원판형 드래그펌프의 성능특성에 관한 연구)

  • Hwang, Young-Kyu;Heo, Joong-Sik
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.643-648
    • /
    • 2001
  • The direct simulation Monte Carlo(DSMC) method is applied to investigate steady and unsteady flow fields of a single-stage disk-type drag pump. Two different kinds of pumps are considered: the first one is a rotor-rotor combination, and the second one is a rotor-stator combination. The pumping channels are cut on a rotor and stator. The rotor and stator have 10 Archimedes' spiral blades, respectively. In the present DSMC method, the variable hard sphere model is used as a molecular model, and the no time counter method is employed as a collision sampling technique. For simulation of diatomic gas flows, the Borgnakke-Larsen phenomenological model is adopted to redistribute the translational and internal energies. The DSMC results are in good agreement with the experimental data.

  • PDF

The Microstructure and Mechanical Properties of Y2O3-Dispersed Fe-C and Fe-CNT Sintered Steels (Y2O3가 분산된 Fe-C 및 Fe-CNT 소결체의 미세구조 및 기계적 특성)

  • Lim, Jin Young;Ahn, Jung-Ho
    • Journal of Powder Materials
    • /
    • v.24 no.4
    • /
    • pp.298-301
    • /
    • 2017
  • In the present work, we use multiwall carbon nanotubes (MWCNT) as the starting material for the fabrication of sintered carbon steel. A comparison is made with conventionally sintered carbon steel, where graphite is used as the starting material. Milling is performed using a horizontal mill sintered in a vacuum furnace. We analyze the grain size, number of pores, X-ray diffraction patterns, and microstructure. Changes in the physical properties are determined by using the Archimedes method and Vickers hardness measurements. The result shows that the use of MWCNTs instead of graphite significantly reduces the size and volume of the pores as well as the grain size after sintering. The addition of $Y_2O_3$.to the Fe-MWCNT samples further inhibits the growth of grains.

Teaching Method of Volume of a Pyramid Using Cavalieri's Principle (카발리에리의 원리를 이용한 피라미드의 부피의 지도 방안)

  • Park, Dal-Won
    • Journal of the Korean School Mathematics Society
    • /
    • v.11 no.1
    • /
    • pp.19-30
    • /
    • 2008
  • Cavalieri is chiefly remembered for his work on the problem "indivisibles." Building on the work of Archimedes, he investigated the method of construction by which areas and volumes of curved figures could be found. Cavalieri regarded an area as made up of an indefinite number of parallel line segments and a volume of an indefinite number of parallel plane areas. He called these elements the indivisibles of area and volume. Cavalieri developed a method of the indivisibles which he used to determine areas and volumes. We call this Cavalieri's principle which states that there exists a plane such that any plane parallel to it intersects equal areas In both objects, then the volumes of the two objects are equal. Cavalieri's principle and method of the indivisibles are very important to understand of volume of a pyramid for gifted students.

  • PDF

Optimal Flow Control of Ceiling Type Indoor Unit by PIV Measurements (PIV 유동 계측을 통한 천장형 실내기의 최적 제어 설계)

  • Sung, Jae-Yong;An, Kwang-Hyup;Lee, Gi-Seop;Choi, Ho-Seon;Lee, In-Seop
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.8
    • /
    • pp.1042-1050
    • /
    • 2003
  • A heating flow discharged from a 4-way ceiling type indoor unit has been investigated to determine the design parameters for the optimal flow control. The flow was measured by a PIV(particle image velocimetry) system and an experimental model of 1/10 scale with a transparent room was devised by satisfying the Archimedes number. This similarity is generally used in cases where the forced convection has similar magnitude of the natural convection. To optimize the heating flow, several vane angles and vane control algorithms of cross and right angle controls were considered. Regarding the vane angle, experimental results show that 30$^{\circ}$is an optimal angle to avoid re-suction flows without significant increase in flow noise. Temperature distribution measured in the environmental chamber ensures the increased thermal comfort when compared to the case, 60$^{\circ}$angle. At the optimal angle, applying open/close control gives rise to more uniform distribution of the heating flow than without control. Especially, the cross-control seems to be satisfactory for thermal comfort.