• Title/Summary/Keyword: Arch dimensions

Search Result 53, Processing Time 0.027 seconds

FABRICATION OF SURGICAL SPLINT BY USING OF SURGICAL JAW RELATOR (Surgical Jaw Relator를 이용한 Surgical splint의 제작)

  • Yang, Sang-Duck
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.27 no.2
    • /
    • pp.188-195
    • /
    • 2005
  • After making the surgical treatment plan, the surgical movements are duplicated in the model surgery. During this procedure, reference points and lines are drawn on the base of the models over the dental arch, and sawcuts are made according to these marked osteotomy lines. This method requires more accuracy for better postsurgical results in that the surgical splint which enables the surgeon to position the jaws intraoperatively is made from the casts as repositioned by the model surgery, and finally it will define the postsurgical results. This technique, however, has been found to be inexact, especially when the jaws are moved in several dimensions simultaneously. To overcome this, different methods have been developed for an accurate repositioning of the jaws as planned. A new appliance, Surgical Jaw Relator, was devised by the author for the simple 3-dimensional relocation of the upper and lower models, resulting in the easy construction of the splints such as centric relation splint, intermediate and final splint. This article describes an introduction and a clinical application of this appliance.

Design of Bristle Shapes using 3-dimensional Teeth Data for the Periodontally Involved Patients

  • Kim, Hyun-Jun;Suh, Myung-Won;Bae, Jong-Hyun
    • Journal of Biomedical Engineering Research
    • /
    • v.27 no.4
    • /
    • pp.180-188
    • /
    • 2006
  • Bristles for the prosthetic and periodontally involved patients are investigated based on previous studies. Specifically, the ideal location and dimensions of bristles for the patients who were installed with fixed prostheses and severely involved periodontitis were investigated. 3D (Three-Dimensional) scanner was used to develop 3D visual models of bristles and teeth. These models were used for designing the ideal bristles. In the design, the interproximal area of dental arch and bristle must be maximized and the standard teeth may have to be chosen from many gypsum molds. During the design process the factors that influence plaque removal by the bristle were considered.

Data Analysis for Structural Design of Pleurotus Eryngii Cultivation Facilities (큰느타리버섯 재배사의 구조설계용 자료 분석)

  • Suh, Won-Myung;Yoon, Yong-Cheol
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.47 no.3
    • /
    • pp.29-37
    • /
    • 2005
  • This study was carried out to file up structural design data for optimizing Pleurotus eryngii growing houses. Design data are including current farm status of Pleurotus eryngii growing houses in the aspect of structural configuration as well as environmental conditions to be controlled and maintained inside. A structural analysis was performed for the on-farm structures as well as some structures modified and suggested through field survey and analysis. The results are summarized as follows. According to the results of status analysis, Pleurotus eryngii growing houses were categorized as arch-roofed simple type and sandwich panel type. Though the size of Pleurotus eryngii cultivation facilities were considerably diverse, the basic dimensions of Pleurotus eryngii cultivation facilities showed relatively similar pattern: more or less of 20m of length, $6.6\~7.0m$ of width, $4.6\~5.0m$ of peak height, $1.2\~1.6m$ of bed width, and 4 layers of bed. In the aspect of spatial use of cultivation facilities, suggested models were shown to be mostly reasonable in the aspect of heating and cooling, micro-meteorological stability, land use efficiency per unit floor area, etc.. Especially, the standard models suggested so far were thought to be not efficient in its surface area and spatial volume per unit floor area as well as its uneffective structural design in the area around ceiling. In the results of structural analysis for the models suggested through this study by using those section frames to be found on farms, the panel type structures of both single span and double span were estimated to be over designed, whereas arch-roofed pipe houses were mostly found to be under-designed.

Spatial changes of the upper dentition following en-masse space closure: A comparison between first and second premolar extraction (En-masse 견인에 의한 발치공간 폐쇄 후 상악치열의 이동양상 -제1소구치 및 제2소구치 발치 비교)

  • Kim, Hui-Jung;Chun, Youn-Sic;Jung, Sang-Hyuk
    • The korean journal of orthodontics
    • /
    • v.35 no.5 s.112
    • /
    • pp.371-380
    • /
    • 2005
  • The purpose of this experimental study was to evaluate aㅜd compare maxillary arch dimensional and positional changes between first and second premolar extraction groups. The Calorific Machine was used to illustrate tooth movement in three dimensions. The experimental teeth except the first or second premolars were embedded in artifical alveolar bone. The extraction space was closed using arch wires with bull loops into which 15 degree gable bends were placed. Before and after space closure, radiographs were taken in the sagittal and occlusal directions using occlusal films. The results showed greater mean maxillary incisor retraction and less anchorage loss in the maxillary first premolar extraction group than in the maxillary second premolar extraction group. Mesiopalatal rotation of anchor teeth was greater after extraction of a maxillary second premolar than a maxillary first premolar (P<.001).

Accuracy of full arch digital model obtained from rendering-based intraoral scanner(IOS) : An example of CS-3600 system (동영상 촬영방식의 구강스캐너로 채득된 전악치열 디지털모형의 정확도 분석 : CS-3600 시스템을 중심으로)

  • Kim, Jae-Hong
    • Journal of Technologic Dentistry
    • /
    • v.42 no.1
    • /
    • pp.17-25
    • /
    • 2020
  • Purpose: The purpose of this study was to evaluate and compare the accuracy of definitive casts that are fabricated from digital intraoral impression and conventional impression technique. Methods: A master model(ANNA-4, Frasaco GmbH, Tettnang, Germany) with the prepared upper full arch tooth was used. Conventional impression and then stone model(n=10) were produced from this master model, and on the other hands, digital impressions were made with the CS-3600 intraoral scanner(n=10). Six linear measurements were recorded between landmarks, directly on each of the stone models on two occasions by a single examiner. Measurements were made with a digital caliper to the nearest 0.01mm from manual models and with the software(Delcam PowerSHAPE) from the virtual models. The t-student test for paired samples and intraclass correlation coefficient(ICC) were used for statistical analysis. Results: The measurement of two methods showed good reliability. The ICC of the two models were 0.88~0.91(stone model) and 0.94~0.99(digital model). The mean differences to master model for stone model and digital model were 0.10~0.14mm, and 0.14~0.20mm, respectively. Conclusion: The definitive casts obtained with digital intraoral technique model had significantly larger dimensions as compared to those of the stone model. However, the differences to the master model detected appear to provide enough accuracy and reliability for clinical application.

Prosthetic rehabilitation of soft palate resection edentulous patient with maxillary obturator (무치악 연구개 결손 환자에서 총의치형 연구개 폐색 장치를 제작한 증례)

  • Ryu, Seung-Beom;Heo, Seong-Joo;Koak, Jai-Young;Kim, Seong-Kyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.4
    • /
    • pp.475-482
    • /
    • 2019
  • This report is a case of 76-year old male patient who had difficulty in swallowing, pronunciation and suffered regurgitation of food. The patient lacks uvula and both tonsils, had short palatoglossal arch and soft palate, as well as defective left palatopharyngeal arch. The height and width of the soft palate defect were measured by reconstructing the Computed Tomography (CT) image in three dimensions. Phonation and soft palate obstructing ability were examined by nasometry and nasal endoscopy. Evaluations on phonetics and swallowing were done and improvements were shown. The patient was satisfied with the results of treatment.

Development of Structural Model and Analysis of Design Factors for Small Greenhouse of Urban Agriculture (도시농업을 위한 소형온실 설계요인 분석 및 구조모델 개발)

  • Kim, Hyung-Kweon;Ryou, Young-Sun;Kim, Young-Hwa;Lee, Tae-Seok;Oh, Sung-Sik;Lee, Won-Suk;Kim, Yong-Hyeon
    • Journal of Bio-Environment Control
    • /
    • v.28 no.4
    • /
    • pp.388-395
    • /
    • 2019
  • The purpose of this study is to suggest structural model and analyze design factors for the development of small greenhouse standardization model. The average dimensions of small greenhouse desired by urban farmers were 3.3m in width, 1.9m in eaves height, 2.7m in ridge height, 5.7m in length. The cladding materials for small greenhouse were preferred to glass, PC board and plastic film, framework to aluminum alloy and steel, and heating method in electrical energy. In addition, it was analyzed that small greenhouses need to develop structural model by dividing them into entry-level type and high-level type. The roof type that was used for entry-level type was arch shape, framework was steel pipe, cladding material was plastic film. On the other hand, high-level type was used in even span or dutch light type, framework with square hollow steel, cladding materials with glass or PC board. In consideration of these findings and practicality, this study developed four types of small greenhouses. The width, eaves height, ridges height, and length of the small greenhouses of even span type, which were covered with 5mm thick glass and 6mm thick PC board were 3m, 2.2m, 2.9m, and 6m, respectively. The small greenhouse of dutch light type covered with 5mm thick glass was designed with 3.8m in with, 2.2m in eaves height, 2.9m in ridges height, and 6m in length. The width, eaves height, ridges height, and length of the arch shape small greenhouse covered with a 0.15mm PO film were 3m, 1.5m, 2.8m, and 6m, respectively.

ORTHOGNATHIC SURGERY USING MODEL REPOSITIONING INSTRUMENT: A CASE REPORT (Model Repositioning Instrument를 이용한 악교정 수술의 치험례)

  • Lee, Nam-Ki;Choi, Dong-Soon;Cha, Bong-Kuen;Park, Young-Wook;Kim, Ji-Hyuck
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.28 no.3
    • /
    • pp.254-261
    • /
    • 2006
  • Moderate to severe dentofacial deformities usually require combined orthodontic treatment and orthognathic surgery to obtain the most stable result with optimal function and facial esthetics. Accordingly, the orthodontist and oral maxillofacial surgeon must be able to exactly diagnose existing deformities, establish an appropriate treatment plan, and execute the recommended treatment. Especially, to obtain optimal result of the maxillary surgery, model surgery is essential. But, the preoperatively planned position of the maxillary dental arch often cannot be sufficiently achieved during actual surgery, and deviations in the sagittal and vertical dimensions are common. To achieve three dimensional repositioning of the maxilla exactly, several methods have been introduced so far. Recently Model Repositioning Instrument (MRI, SAM, Inc., $M\ddot{u}nchen$, Germany), one of these methods, has been introduced and applied clinically, which is reported as accurate, effective and prompt method for three dimensional repositioning of the maxilla. This article describes an introduction and a clinical application of this MRI.

Investigation on the masonry vault by experimental and numerical approaches

  • Guner, Yunus;Ozturk, Duygu;Ercan, Emre;Nuhoglu, Ayhan
    • Earthquakes and Structures
    • /
    • v.23 no.1
    • /
    • pp.13-21
    • /
    • 2022
  • Masonry constructions exhibit uncertain behaviors under dynamic effects such as seismic action. Complex issues arise in the idealization of structural systems of buildings having different material types and mechanical properties. In this study, the structural behavior of a vaulted masonry building constructed using full clay brick and lime-based mortar and sitting on consecutive arches was investigated by experimental and numerical approaches. The dimensions of the structure built in the laboratory were 391 × 196 cm, and its height was 234 cm. An incremental repetitive loading was applied to the prototype construction model. Along the gradually increasing loading pattern, the load-displacement curves of the masonry structure were obtained with the assistance of eight linear displacement transducers. In addition, crack formation areas, and relevant causes of its formation were determined. The experimental model was idealized using the finite element method, and numerical analyses were performed for the area considered as linear being under similar loading effect. From the linear analyses, the displacement values and stress distribution of the numerical model were obtained. In addition, the effects of tie members, frequently being used in the supports of curved load-bearing elements, on the structural behavior were examined. Consequently, the experimental and numerical analysis results were comparatively evaluated.

Accuracy of lingual fixed retainers fabricated using a CAD/CAM bending machine

  • Fu Ping Cui;Jung-Jin Park;Seong-Hun Kim
    • The korean journal of orthodontics
    • /
    • v.54 no.4
    • /
    • pp.257-263
    • /
    • 2024
  • Objective: Lingual fixed retainers, made from 0.0175-inch 3-strand twisted stainless steel wire (TW) and 0.016 × 0.022-inch straight rectangular wire (RW), are generally used in clinical practice. This study aimed to calculate their accuracy by comparing the discrepancy between computer-aided customized retainers made from these two types of wires. Methods: Eleven orthodontic patients were selected, resulting in 22 maxillary and mandibular three-dimensional printing dental models. Two types of lingual fixed retainers were bonded from canine to canine. To determine the accuracy, five points were chosen for each model, resulting in 110 selected points. The absolute values of the distances on the x-, y-, and z-axes were measured to compare the accuracy of the two types of computer-aided retainers. Results: The accuracy of the two types of retainers did not differ significantly in the x- and z-axes, but only in the y-axis (P < 0.01), where RW-fixed retainers exhibited a slightly but significantly increased distance compared to the TW. Conclusions: Both types of retainers showed high accuracy; however, RW had a slight but statistically significant difference along the y-axis compared with TW. This type of computer-aided design/computer-aided manufacturing bending machine is limited to two dimensions, and the dental arch is curved. Therefore, RW may require slight manual adjustment by the practitioner after manufacturing.