• Title/Summary/Keyword: Arc voltage signal

Search Result 44, Processing Time 0.027 seconds

A Study on the High Speed Interruption of Parallel Arcing (병렬아크의 고속차단에 관한 연구)

  • Kil, Gyung-Suk;Ji, Hong-Keun;Park, Dae-Won;Kim, Il-Kwon;Kim, Young-Il;Cho, Young-Jin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.12
    • /
    • pp.95-100
    • /
    • 2008
  • Conventional Earth Leakage Circuit Breakers (ELCBs) have defects of a breaking failure or a long breaking-time against parallel arc current. In this paper, breaking characteristics of conventional ELCBs were analyzed by simulation of parallel arc in a low-voltage indoor wiring system, and an air-core current sensor and a signal converter being most available for parallel arc detection were developed and applied to a conventional ELCB. The proposed tripped the ELCB regardless of the location of parallel arc. The breaking-time was in ranges of $1.74{\sim}8.3[ms]$ depending on the phase of arc generation, which is about 5 times as fast as conventional ELCBs with the breaking-time of 50[ms].

A Study on the Diagnostic Algorithm for Arc Flash of Power Equipment (전력기기의 아크 플래시 진단 알고리즘에 관한 연구)

  • Lee, Deok-Jin
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.7
    • /
    • pp.449-453
    • /
    • 2016
  • The amount of electrical energy has been increased with the rapid development of the industrial society. Accordingly, operating voltage of the power equipment and facility capacity are continuously increasing. Development trends of recent high-voltage electrical equipment are ultra high-voltage, large-capacity and compact. Early diagnosis of a failure of the power plant has been emerging as an important task as to supply high quality power to users. In this study, we have tried to develope an algorithm for distinguishing an arc fault signal generated in the power plant by using UV sensor.

A Study of an Automatic Tip-to-Workpiece Distance Control System for Plasma Arc Cutting (플라즈마 아크 절단에서 팁-모재간 거리 자동제어 시스템에 관한 연구)

  • 구진모;김재웅
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.7
    • /
    • pp.132-140
    • /
    • 2000
  • Plasma arc cutting is one of the most widely used processes in metal cutting fields and is a process that produces parted metal plates by cutting them with an arc plasma established between the electrode tip and the plate(workpiece). When the tip-to-workpiece distance varies during cutting, the cut quality, for example the kerf width, is deteriorated by the change of plasma arc. The variations of tip-to-workpiece distance are due to the different factors such as inaccuracies in setting the torch or workpiece, thermal distortions during cutting, and uneven surface of workpiece. The control to keep the tip-to-workpiece distance constant is thus indispensable to improve the flexibility of automatic plasma arc cutting system applications. In this study, an arc sensor which utilizes the electrical signal obtained from the plasma arc itself was developed. The arc sensor has an advantage that no particular sensing device is necessary and real-time sensing of the tip-to-workpiece distance is possible directly under the plasma arc. The relationship between plasma arc voltage and tip-to-workpiece distance was determined through the repeated experimental results. The model was used for developing an automatic tip-to-workpiece distance control system of plasma arc cutting. It could be shown that the proposed system has a successful capability of tip-to-workpiece distance control.

  • PDF

A study on the welding current and voltage signal processing method for the quality evaluation of robotic GMAW (GMAW 품질분석을 위한 신호처리 방법에 관한 연구)

  • Hong, Woo Heon;Ryu, Jeong Tak
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.19 no.6
    • /
    • pp.25-31
    • /
    • 2014
  • Gas metal arc welding (GMAW) is currently the most widely used arc welding processes in the industry because of its high metal deposition rate, flexibility and low cost. It is attractive for high-productivity manufacturing applications and is well suited to automatic or robotic welding. Welding voltage and current have a significant impact on the weld bead. However, welding voltage and current are changed variously according to welding condition and user environment, and prediction is impossible. To determine the welding conditions, the welding current and voltage are applied to the appropriate data analysis techniques. In this paper, we used the moving average filter to the welding voltage and current data, and normal and abnormal welding waves were distinguished.

Development of Monitoring Program for Detecting Current and Voltage Signals for Series Arc (직렬아크에 대한 전류 및 전압 신호분석이 가능한 Monitoring Program 개발)

  • Kim, Doo-Hyun;Park, Jong-Young;Kim, Sung-Chul;Lee, Jong-Ho
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.2
    • /
    • pp.29-34
    • /
    • 2010
  • This paper is aimed to develop monitoring software for detecting the characteristics of current and voltage signals for series arc on electric wire. In order to attain this purpose, the characteristics of series arc were analyzed by the current and voltage signals on electric wire which were installed, and also analyzed by the changes of RMS, instantaneous of waveform value in time domain and THD in frequency domain. Monitoring program which analyze the signal was developed by Labview which can analyze in time domain and frequency domain, and save data. Experimental setup for detecting verification of monitoring program was composed loads of a lamp, an electric heater and an electric fan loads which were usually using. Measurement points for detecting verification of monitoring program were selected at both the panel board and the arc generator at the same time. As results of the experiments by monitoring program, the arc current waveform showed the same characteristic in all measurement points of all load. But the arc voltage waveform was different in each measurement point. When arc occurred, the THD of current value increased above 20%. The results of this study will be effectively used in developing the preventive system of electric fire by series arc.

A Study on the Detection Algorithm of Series Arc Signals in Air Conditioners (에어컨에서 직렬아크검출 알고리즘에 관한 연구)

  • Ji, Hong-Keun;Choi, Sung-Kuk;Jung, Kwang-Seok;Park, Dae-Won;Kil, Gyung-Suk
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.1970-1976
    • /
    • 2009
  • This paper describes a series arc detection algorithm in a low-voltage wiring system. We designed and fabricated an arc detection circuit which consists of a high-pass filter with the low cut-off frequency of 170 kHz to attenuate power frequency. The series arcing phenomena was simulated by an arc generator specified in UL1699. In the experiment, various loads such as resistive loads, resistive loads controlled by a dimmer, and vacuum cleaners were used. Whether the signal is arc or noise is discriminated by pulse counts and periodicity of the detected signal.

  • PDF

Detection Method of Series Arc Signal (직렬아크신호지 검출방법)

  • Kil, Gyung-Suk;Ji, Hong-Keun;Park, Dae-Won;Kim, Il-Kwon;Rhyu, Keel-Soo;Song, Jae-Yong
    • Journal of the Korean Society for Railway
    • /
    • v.11 no.5
    • /
    • pp.477-481
    • /
    • 2008
  • This paper dealt with a detection method of series arc existence which is a symptom of electric fires in low-voltage system. The proposed detection circuit consists of a high-pass filter with a low cut-off frequency of 3kHz to attenuate power frequency voltage by 80 dB and an active band-pass filter with a center frequency of 4kHz to detect only the series arc signals. The performance of the circuit was evaluated in a phase-controlled incandescent lamp as a non-linear load and an inverted-fed induction motor as a high frequency load by using the arc generator specified in UL1699. From the experimental results, it was confirmed that the proposed method solved the detection error, which is being the most problem, by discriminating the series arc signal even in non-linear and high frequency loads.

A Study on the Series Arc Detection Algorithm (직렬아크 검출 알고리즘에 관한 연구)

  • Kim, Il-Kwon;Park, Dae-Won;Choi, Su-Yeon;Park, Chan-Yong;Kil, Gyung-Suk
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.1433-1437
    • /
    • 2007
  • This paper describes the detection algorithm which can distinguish series arcing signal from voltage harmonics or noises produced by the operation of non-linear loads. A high pass filter with the cutoff frequency of 3 kHz is designed and it can attenuate power frequency signal to 80 dB. Series arcing phenomena is simulated to an incandescent lamp controlled by a dimmer. From the experimental results, it is confirmed that the amplitude of the filter output voltage varies at random during series arcing but the signal generated by non-linear loads appears on a regular basis. We proposed a series arcing detection algorithm using the chaotic nature of voltage signal.

  • PDF

Highly Sensitive Partial Discharge Sensor with Remote Monitoring Capabilities (원격감시 기능을 갖는 고감도 부분방전센서)

  • Choi, Kyoo-Nam
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.10 no.3
    • /
    • pp.349-356
    • /
    • 2015
  • Remote monitoring partial discharge sensor, equipping with hybrid filter combining optical and electrical noise reduction capabilities and with signal integrating function to calculate total arc energy, was investigated. Hybrid filter showed insensitivity to fluorescent and incandescent lamps under simulated distribution panel condition. Signal integrating function showed selective detection capability corresponding to different arc energy levels, while convention arc sensor had difficulty to discriminate arc energy level due to bursty arc waveform and peak level detection characteristics. The sensor showed possibility for application to remote monitoring partial discharge sensor, since it detected arc energy level corresponding to normal open and close discharge in low voltage 100A MCCB at 2m distance.

A Study on the Weavingless Arc Sensor System in GMA Welding (I) -Implementation of Weld Seam Tracking Algrithm- (GMA 용접에서 강제적인 위빙이 없는 아크센서 시스템에 관한 연구 (I) -용접선 추적 알고리즘의 구현-)

  • 안재현;김재웅
    • Journal of Welding and Joining
    • /
    • v.16 no.3
    • /
    • pp.44-54
    • /
    • 1998
  • In this study a new arc sensor algorithm for automatic weld seam tracking was proposed, which uses the relative welding current variation according to the tip-to-workpiece distance in GMA welding. Since the new developed arc sensor algorithm is not sensitive to unstable factors of arc signal, the system is expected to get rid of the problems of already existing arc sensor system which include the difficulty of modeling the process for various welding conditions and limitation of application to thick plate welding. Thus the system is applicable not only to thick plate welding but also to thin plate welding. To implement the new arc sensor algorithm the system parameters which include sampling time, averaging range, weighting factor of moving averaging, basic compensation time, and basic compensation distance were determined by experimental analysis. Consequently this system has shown the successful tracking capability for the various welding conditions.

  • PDF