• 제목/요약/키워드: Arc detector

검색결과 63건 처리시간 0.024초

Performance assessment of HEPA filter to reduce internal dose against radioactive aerosol in nuclear decommissioning

  • Hee Kwon Ku;Min-Ho Lee;Hyunjin Boo;Geun-Dong Song;Deokhee Lee;Kaphyun Yoo;Byung Gi Park
    • Nuclear Engineering and Technology
    • /
    • 제55권5호
    • /
    • pp.1830-1837
    • /
    • 2023
  • The thermal cutting of contaminated or activated metals during decommissioning nuclear power plants inevitably results in the release of radioactive aerosol. Since radioactive aerosols are pernicious particles that contribute to the internal dose of workers, air conditioning units with a HEPA filter are used to remove radioactive aerosols. However, a HEPA filter cannot be used permanently. This study evaluates the efficiency and lifetime of filters in actual metal cutting condition using a plasma arc cutter and a high-resolution aerosol detector. The number concentration and size distribution of aerosols from 6 nm to 10 ㎛ were measured on both the upstream and downstream sides of the filter. The total aerosol removal efficiency of HEPA filter satisfies the standard of removing at least 99.97% of 0.3 ㎛ airborne particles, even if the pressure drop increases due to dust feeding load. The pressure drop and particle size removal efficiency at 0.3 ㎛ of the HEPA filter were found to increase with repeated cutting experiments. By contrast, the efficiency of used HEPA filter reduced in removing nano-sized aerosols by up to 79.26%. Altogether, these results can be used to determine the performance guidance and replacement frequency of HEPA filters used in nuclear power plants.

다용도 팬톰에서 정위방사선수술기법의 선량 정확도 확인 (Confirmation of the Dose Distribution by Stereotactic Radiosurgery Technique with a Multi-purpose Phantom)

  • 유형준;김일한;하성환;박찬일;허순녕;강위생
    • Radiation Oncology Journal
    • /
    • 제20권2호
    • /
    • pp.179-185
    • /
    • 2002
  • 목적 : 본 교실에서 개발한 정위방사선수술 시스템의 정도관리를 위하여 다용도 팬톰을 제작하고 정위방사선수술 기법의 선량의 정확도를 확인하려 하였다. 대상 및 방법 : CL2100C 선형가속기에서 발생하는 6 MV 엑스선을 사용하여 정위적 방사선수술을 시행하였고 Farmer형 이온함, 0.125 cc 이온함, 다이오드 검출기 등을 정위 기준기구가 부착된 팬톰내에 설치한 후 선량을 측정하였다. 고정 빔, $20^{\circ}\~100^{\circ}$의 각도를 갖는 단일회전빔, 복합회전빔 등의 방사선조사 조건에서 측정기와 팬톰의 상대적 위치를 변화시키면서 측정하였다. 내경이 10, 20, 30, 40 mm인 원형의 3차 콜리메이터를 사용하였다. 결과 : 고정 빔, 단일 회전빔, 5개의 회전 빔으로 구성된 복합회전빔 등에서의 선량오차는 Farmer형 이온함으로 측정한 경우는 $0.5\%$ 이하, 0.125 cc 이온함의 경우에는 $0.5\%$, 다이오드 검출기인 경우에는 $2\%$ 이내였다. 결론 : 본 교실 개발 정위방사선수술 기법에 의한 방사선 조사선량의 정확도를 확인하였으며 이 자료는 향후 정위방사선수술 및 다분할 방사선치료의 정도관리에 유용한 기초자료로 활용될 것이다.

Lifting을 이용한 고저항고장 검출에 관한 연구 (A Study on High Impedance Fault Detection using Lifting Scheme)

  • 홍대승;임화영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 D
    • /
    • pp.2228-2230
    • /
    • 2002
  • The research presented in this paper focuses on a method for the detection of High Impedance Fault(HIF). The method will use the Lifting and neural network system. HIF on the multi-grounded three-phase four-wires primary distribution power system cannot be detected effectively by existing over current sensing devices. These paper describes the application of lifting scheme to the various HIF data. These data were measured in actual 22.9kV distribution system. Wavelet transform analysis gives the frequency and time-scale information. The neural network system as a fault detector was trained to discriminate HIF from the normal status by a gradient descent method. The proposed method performed very well by proving the right state when it was applied staged fault data and normal load mimics HIF, such as arc-welder.

  • PDF

대용량 PV 시스템 적용을 위한 DWT 알고리즘 기반 태양광 직렬 아크 검출기 (DC Series Arc Fault Detector Based on the Discrete Wavelet Transform Algorithm for a Large Photovoltaic System)

  • 조찬기;안재범;이진한;류홍제
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2020년도 전력전자학술대회
    • /
    • pp.1-3
    • /
    • 2020
  • 본 논문은 주파수 분석 방법 중 하나인 Discrete Wavelet Transform (DWT)을 활용하여 태양광 직렬 아크 사고를 검출하는 방법에 관하여 다룬다. DWT 알고리즘은 주파수 도메인에서도 시간 축 정보를 표현할 수 있어 기존의 Fast Fourier Transform (FFT) 주파수 분석 알고리즘과 차이점이 있으며, 대용량 태양광 시스템의 직렬 아크 사고 검출에 최적화 되도록 DWT 알고리즘의 속도를 향상시켜 태양광 DC 아크 사고 안전규격인 UL1699B의 요구 조건을 만족시켰다. DWT 알고리즘의 경우 TMS320F28033 기반으로 구현 되었으며 대용량 PV 시스템 적용을 위해 로고스키코일을 전류 센서로 사용하였다. 또한, 모의 DC 직렬 아크 발생 회로를 구축하여 제작한 사고 검출기의 성능을 실제 아크 발생 조건에서 검증하였다.

  • PDF

체적변조회전치료에서 Hybrid Optimized VMAT Phantom (HOVP)을 이용한 실시간 환자 맞춤형 정도관리를 위한 예비연구 (A Pilot Research for Real-Time Specific Patient Quality Assurance Using the Hybrid Optimized Vmat Phantom (Hovp) in Volume Modulated Arc Therapy)

  • 허현도;최상현;김우철;김헌정;김금배;김성훈;조삼주;민철기;조광환;이상훈;이석;심장보;신동오;지영훈
    • 한국의학물리학회지:의학물리
    • /
    • 제22권4호
    • /
    • pp.206-215
    • /
    • 2011
  • 다엽콜리메이터, 겐트리회전, 선량율 등에서 형성되는 플루언스 맵을 이용하여 환자 맞춤형 치료 선량검증이 가능한지 알아보았다. 플루언스 맵은 2D 배열 검출기로 측정하였고, 동일 치료계획을 팬톰 내에서 이온전리함, 필름, 유리선량계 등을 이용하여 측정 비교하였다. 목표점에서 체적감마인자(volume gamma index, 3%, 3 mm)기준에 통과율은 $85.22%{\pm}1.7$(RT_target), $89.96%{\pm}2.15$였고, G4는 $95.14%{\pm}1.18$이었다. 선량 전달 오차는 선량이 급격히 변화는 영역(G1, G2, G3)과 주요장기(G4)에서 각각 $11.72%{\pm}0.531$, $-11.47%{\pm}0.991$, $7.81%{\pm}0.857$, $-4.14%{\pm}0.761$이었다. 이온전리함 측정값의 상대오차는 각각 평균 $-1.02%{\pm}0.222$ (Rt_target), $0.96%{\pm}0.294$ (Lt_target)이었다. 필름의 감마인자(3%, 3 mm) 기준 평균 통과율은 $92.59%{\pm}3.312$이었다. 유리선량계 상대 오차는 8.3% (G1), -5.4% (G2), 7.2% (G3), 6.1% (G4)이었다. 체적변조회전방사선 치료(VMAT)시 실시간 플루언스 맵 측정을 통한 실시간 환자 맞춤형 선량 검증이 가능할 것으로 사료되었다.

Planning and Dosimetric Study of Volumetric Modulated Arc Based Hypofractionated Stereotactic Radiotherapy for Acoustic Schwannoma - 6MV Flattening Filter Free Photon Beam

  • Swamy, Shanmugam Thirumalai;Radha, Chandrasekaran Anu;Arun, Gandhi;Kathirvel, Murugesan;Subramanian, Sai
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권12호
    • /
    • pp.5019-5024
    • /
    • 2015
  • Background: The purpose of this study was to assess the dosimetric and clinical feasibility of volumetric modulated arc based hypofractionated stereotactic radiotherapy (RapidArc) treatment for large acoustic schwannoma (AS >10cc). Materials and Methods: Ten AS patients were immobilized using BrainLab mask. They were subject to multimodality imaging (magnetic resonance and computed tomography) to contour target and organs at risk (brainstem and cochlea). Volumetric modulated arc therapy (VMAT) based stereotactic plans were optimized in Eclipse (V11) treatment planning system (TPS) using progressive resolution optimizer-III and final dose calculations were performed using analytical anisotropic algorithm with 1.5 mm grid resolution. All AS presented in this study were treated with VMAT based HSRT to a total dose of 25Gy in 5 fractions (5fractions/week). VMAT plan contains 2-4 non-coplanar arcs. Treatment planning was performed to achieve at least 99% of PTV volume (D99) receives 100% of prescription dose (25Gy), while dose to OAR's were kept below the tolerance limits. Dose-volume histograms (DVH) were analyzed to assess plan quality. Treatments were delivered using upgraded 6 MV un-flattened photon beam (FFF) from Clinac-iX machine. Extensive pretreatment quality assurance measurements were carried out to report on quality of delivery. Point dosimetry was performed using three different detectors, which includes CC13 ion-chamber, Exradin A14 ion-chamber and Exradin W1 plastic scintillator detector (PSD) which have measuring volume of $0.13cm^3$, $0.009cm^3$ and $0.002cm^3$ respectively. Results: Average PTV volume of AS was 11.3cc (${\pm}4.8$), and located in eloquent areas. VMAT plans provided complete PTV coverage with average conformity index of 1.06 (${\pm}0.05$). OAR's dose were kept below tolerance limit recommend by American Association of Physicist in Medicine task group-101(brainstem $V_{0.5cc}$ < 23Gy, cochlea maximum < 25Gy and Optic pathway <25Gy). PSD resulted in superior dosimetric accuracy compared with other two detectors (p=0.021 for PSD.

RapidArc를 이용한 호흡연동 회전세기조절방사선치료 할 때 전달선량의 정확성 평가 (Evaluation of the Accuracy for Respiratory-gated RapidArc)

  • 성지원;윤명근;정원규;배선현;신동오;김동욱
    • 한국의학물리학회지:의학물리
    • /
    • 제24권2호
    • /
    • pp.127-132
    • /
    • 2013
  • 환자 호흡할 때 흉 복부 내부에 있는 장기의 위치는 주기적으로 변한다. 이에 따라 방사선치료 동안 종양에 대한 선량불확도가 발생하게 되며, 불확도를 줄이기 위한 여러 방사선치료방법이 제시되고 있다. 호흡연동방사선치료는 특정 위상 또는 진폭에만 방사선을 조사하는 방법으로 불필요한 피폭선량은 줄일 수 있는 장점이 있지만 긴 치료 시간과 노력이 필요하다는 단점이 있다. 호흡연동방사선치료 중 회전세기조절방사선치료(respiratory gated Volumetric Modulated Arc Therapy, VMAT)는 다른 호흡연동치료시스템에 비해 치료 시간이 짧다는 장점이 있기 때문에 본 연구는 respiratory gated VMAT 치료 선량의 정확성을 검증하여 임상 적용의 적절성을 평가하고자 한다. 본 연구는 총 6개의 VMAT 치료계획(Eclipse, ver. 8.6, Palo Alto, USA)을 토대로 수행되었으며, 각각의 치료계획은 AAA 알고리즘을 이용해서 선량이 계산되었다. 환자의 호흡운동을 구현하기 위해 환자 테이블 위에 1차원운동팬텀이 사용되었으며, 영상 기반 추적 시스템(Real-time Position Management, RPM, Varian Medical Systems, Palo Alto, USA)을 통해 운동 주기 신호를 획득하였다. 또한, 2차원-이온함-배열(MatriXX, IBA, Germany) 측정기를 이용하여 특정 호흡 신호 위상에 따른 전달 선량을 측정하였다. 측정된 선량과 치료 계획된 선량을 정성적인 분석을 위해 상용화되어 있는 선량분석용 프로그램(I'mRT, IBA, Germany)을 통해 2차원 선량분포를 0에서 1사이의 감마지표(Gamma index) 비교 결과 모든 케이스에서 97% 이상의 일치함을 확인하였다. 따라서 호흡연동 회전세기조절 방사선치료는 호흡연동방사선치료의 단점인 시간적인 제약을 일정 부분 해소할 수 있었으며 2차원 선량분포 비교 결과 오차값 3%이내의 정확도에서 환자정도관리 수준을 만족하였고 임상적용이 가능함을 확인하였다.

MOSFET를 이용한 X선 신호의 전기적 획득에 관한 연구 (The study for electric readout of X-ray signal using MOSFET)

  • 박성광;강영수;서지현;박지군;남상희
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1998년도 추계학술대회
    • /
    • pp.295-296
    • /
    • 1998
  • With xeroradiography appearance, DR (Digital Radiography) system have been studying for X-ray detection using photoreceptor. Also detection method for receptor charge change have been developing variably. We use photoreceptor material of a-Se(Amorphous Selenium) with high DQE, high SNR(Signal to Noise Ratio) and high transformation efficiency of X-ray signals into electrical signals. After a-Se receptor is uniformly charged by using Arc discharge, X-ray is exposed. Then a-Se receptor produce subtle charge variation and MOSFET detect charge variations. The detected signal pass A/D converter and signal processing by PC. As results, the initial voltage is 8V. It has wide dynamic range needed digital radiography system. In this study, we obtained data with changing kVp(tube potential voltage) and fixed 8mAs(tube current by exposure time) in X-ray system. However MOSFET detector for X-ray signal is not tested X-ray mAs variations. But if MOSFET detector is tested X-ray mAs variation and exactly calibrated multichannel is made and noise-reduction is done, suitable DR system readout method will be done.

  • PDF

천문관측용 PtSi 전하결합소자 적외선 카메라의 개발 (DEVELOPMENT OF AN ASTRONOMICAL INFRARED PtSi CAMERA)

  • 홍승수;우에노무네타카;구본철;김광태;김칠영;오갑수;이명균;이형목;강용우;박원기
    • 천문학논총
    • /
    • 제11권1호
    • /
    • pp.1-26
    • /
    • 1996
  • We have built a near-infrared imaging camera with a PtSi array detector manufactured by the Mitsubishi Company. The PtSi detector is sensitive in the wavelength range 1 to $5{\mu}m$. Quantum efficiency of PtSi is much lower than that of InSb and HgCdTe types. However, the PtSi array has advantages over the latter ones: (i)The read-out noise is very low; (ii)the characteristics of the array elements arc uniform and stable; (iii)it is not difficult to make a large PtSi array; and (iv) consequently the price is affordably low. The array used consists of $512{\times}512$ pixels and its size is $10.2\;mm{\times}13.3\;mm$. The filter wheel of the camera is equipped with J, H, K filters, and an aluminum plate for measuring the dark noise. The dewar is cooled with liquid nitrogen. We have adopted a method of installing the clock pattern and the observing softwares in the RAM, which Gill he easily used for other systems. We have developed a software with a pull-down menu for operating the camera and data acquisition. The camera has been tested by observing $\delta$ Orionis.

  • PDF