• Title/Summary/Keyword: Arc Metal Spray Method

Search Result 13, Processing Time 0.017 seconds

An Experimental Study on Corrosion Behavior in Steel of Concrete Applied with Arc Metal Spray Method Surface Treatment Technology Using EIS (EIS를 이용한 아크 금속용사 표면처리기법이 적용된 강재의 콘크리트 내 부식 거동에 관한 실험적 연구)

  • Yoon, Chang-Bok;Park, Jang hyun;Lee, Han-Seung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.3
    • /
    • pp.87-95
    • /
    • 2020
  • As an experimental study on the corrosion behavior of steel materials to which ATMS method using EIS was applied in concrete, immersion of Ca(OH)2 saturated aqueous solution and NaCl aqueous solution simulating the environment inside concrete The corrosion behavior was tested. The equivalent circuit was derived through the analysis of the Nyquist plot, and the interfacial resistance and the polarization resistance of the Ca(OH)2 aqueous solution were compared, and Al ATMS was the best interfacial resistance and Zn ATMS was the best polarization resistance. After burying ATMS steel material of cement mortar, the initial immersion impedance measurement value was the highest in the Zn ATMS test body in the impedance measurement by the immersion time by immersing it in the NaCl aqueous solution. Al ATMS test piece has the highest impedance and is highly reliable. This is because Al, which has a high ionization tendency, is continuously oxidized in a strong alkaline environment to form a film and protect the steel from permeation of chlorine ions.

An Electrochemical Evaluation on the Corrosion Property of Metallizing Film (용사 도막의 내식성에 관한 전기화학적 평가)

  • Moon, Kyung-Man;Shin, Joong-Ha;Lee, Myung-Hoon;Lee, Sung-Yul;Kim, Yun-Hae
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.5
    • /
    • pp.670-677
    • /
    • 2010
  • There are many surface protection methods for numerous steel structures being used under severely corrosive environment, one of them, metallizing(thermal spray) is a available protection method which is comparatively and recently developed for surrface protection of various steel structures. However coating film obtained by spraying is to be needed increasingly more good corrosion resistance due to accelerating of environmental contamination. In this study, coating films(DFT:$200{\mu}m$) are performed with arc spray by wire metal and their types of films are pure zinc, pure aluminum, alloy film(Al:Zn=85:15) and alloy film(Al:Zn=95:5). And corrosion resistance of their films was investigated with electrochemical methods in seawater solution. Pure aluminum film showed a relatively somewhat good corrosion resistance compared to among those of other films and alloy films also showed a good corrosion resistance compared to pure zinc film. Especially it was observed that pure aluminum film showed a comparatively good corrosion resistance than that of alloy film named as galvarium spray(Al:Zn=85:15) in seawater solution. Morphology of corroded surface of pure zinc film appeared the pattern like intergranlar corrosion, however films of pure aluminum and alloy metal showed a general corrosion pattern.

An Experimental Study on Evaluation of Bond Strength of Arc Thermal Metal Spaying According to Treatment Method of Water Facilities Concrete Surface (수처리 시설물 콘크리트 표면처리 방법에 따른 금속용사 피막의 부착성능 평가에 관한 실험적 연구)

  • Park, Jin-Ho;Lee, Han-Seung;Shin, Jun-Ho
    • Journal of the Korea Institute of Building Construction
    • /
    • v.16 no.2
    • /
    • pp.107-115
    • /
    • 2016
  • In this study, the bond strength of metal spraying system by surface treatment of concrete (waterproof/corrosion method) in water treatment facilities was evaluated. The results showed that the system with Sa-P-R-(S) (sanding-perviousness surface hardener-surface roughness agent-metal spraying-sealing) led to the desirable performance. The bond strength, the coefficient of water permeability and air permeability were 3.7MPa, $0.68{\ast}10^{-8}cm/sec$, and $0.45{\ast}10^{-16}m^2$, respectively. In scanning electron microscope analysis, the microstructure of specimen coated with perviousness surface hardener was much denser than that without it. Therefore, the specimen coated with sanding-perviousness surface hardener-surface roughness agent-metal spraying-sealing had the best bond performance and was the most suitable system to concrete surface in water treatment facilities.