• 제목/요약/키워드: Arc Fault

검색결과 229건 처리시간 0.034초

고장 전압의 correlation을 이용한 2차 아크 소호 판별 (A Detection Scheme of a Secondary Arc Extinction Using Correlation of a Fault Voltage)

  • 장원혁;서훈철;김철환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.340_341
    • /
    • 2009
  • This paper suggests a detection scheme of a secondary arc extinction using the peak value of a fault voltage estimated by correlation algorithms. The system implemented in this paper is based on a Korean 765 kV system and the suggested proposed scheme is tested on the system. The performance of the method is analyzed by using Electro-Magnetic Transients Program (EMTP)/ATPDraw.

  • PDF

전기화재 징후 감지를 위한 아크전류 파형분석에 관한 연구 (A Study on Analysis of Arc Current Waveforms for Detection of Prognostics of Electrical Fires)

  • 황진권
    • 한국화재소방학회논문지
    • /
    • 제23권1호
    • /
    • pp.7-14
    • /
    • 2009
  • 전류 돌입형, 비선형 및 전류 단속형 부하들은 정상작동 상태에서 아크 발생의 경우와 유사한 전류파형을 갖는다. 이러한 부하들에서 아크 검출기법을 정확하게 구현하기 위하여서는 아크 유무에 따른 전류파형의 전형적인 특징을 찾을 필요가 있다. 본 논문에서는 UL 1699의 직렬과 병렬 아크 발생장치들로 이러한 부하들에 마크를 발생시키고 시간 및 주파수 영역에서 아크 전류파형을 분석한다. 아크 실험의 분석결과를 통하여 아크 전류파형의 전형적인 특징은 시간영역에서는 영점전류의 처짐 현상이고 주파수영역에서는 60Hz 고조파 성분을 제외한 전대역의 주파수에 걸쳐서 스펙트럼 크기가 증가되는 것임을 보인다. 비선형 및 전류 단속형 부하들에서 시간영역보다는 주파수영역의 아크 전류의 특징이 보다 명확히 나타남을 보인다. 본 논문에서 제시된 아크 전류파형의 특징들은 아크 차단기 개발을 위한 기반자료로 활용될 것으로 기대된다.

차단용량 향상을 위한 신소호 구조 (New Arc Chamber to Improve Breaking Capacity)

  • 박진영;조해용
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제36권2호
    • /
    • pp.321-326
    • /
    • 2012
  • 배선용 차단기(MCCB)를 구성하는 개폐기구부, 아크(Arc)소호부, 트립(Trip)부는 차단기의 성능을 결정짓는 중요한 요소들이다. 그 중 아크소호부는 차단시 발생한 아크를 소호실 안쪽으로 유도하여 여러개의 짧은 아크로 분할시키며 아크를 냉각, 소멸시켜 차단을 빠르게 하는 구조이다. 본 연구에서는 새로운 소호구조를 제안하였고, 차단 성능이 우수한 변수에 대한 최적화 실험을 하였으며, 이를 토대로 실제 실험제품에 적용하여 성능 향상에 대한 연구를 수행하였다.

50kW 태양광 설비의 아크 검출 알고리즘 개발 (Development of Arc Detection Algorithm for 50 kW Photovoltaic System)

  • 김상규;이창성;지평식
    • 전기학회논문지P
    • /
    • 제67권1호
    • /
    • pp.27-32
    • /
    • 2018
  • In this paper, we developed an algorithm to detect arc of PV power plant through frequency analysis. For arc detection based on frequency analysis, the filter should be designed to emphasize the difference between the arc state and the normal state. Therefore, in this paper, we analyzed the arc detection performance according to various filter structures. The arc detection algorithm developed in this paper extracts the filtering signal on current by using various filters and then calculates the frequency components and total energy using the FFT. In the final step, the arc is detected using the calculated energy magnitude. In order to verify the performance of the proposed arc detection algorithm, experiments were conducted on 51 kW solar inverters connected to power line. Through various experiments, it was confirmed that the proposed method effectively detects the arc.

사고전압 감지형 아크차단 제어회로 개발 (Development of Arc Fault Interruption Control Circuit of Fault Voltage Sensing Type)

  • 곽동걸;변재기;이봉섭
    • 한국화재소방학회논문지
    • /
    • 제27권2호
    • /
    • pp.1-5
    • /
    • 2013
  • 본 논문은 사고전압 감지형의 아크차단 제어회로에 대한 연구로써, 전기사고 발생 시 선간전압의 순간적인 전압감쇠를 감지하여 기존 차단기를 동작시키는 전압감지형 전기화재 예방장치이다. 현재 저압배전 계통에 사용중인 누전차단기, 배선용차단기 그리고 RCD 등은 전기화재의 주요 요인인 아크사고에 대해 보호능력이 없는 것으로 분석된다. 본 논문에서는 이러한 문제점들을 개선하기위하여 이전의 전류감지에 의한 아크사고 차단방식이 아닌 사고발생 시 전압파형의 왜곡을 이용한 새로운 전압감지형 아크차단 제어회로를 개발하여 전기화재를 예방하고자 한다. 제안한 아크차단 제어회로는 소형 경량으로 제작되는 장점과 다양한 동작분석을 통하여 그 실용성을 검증하였다.

아크플래시 장해 대책 보호계전기 협조 검토 (Protection Relay Coordination Study for Reducing Arc Flash Hazard)

  • 이강완;양정욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.545-546
    • /
    • 2015
  • Arc flash hazard study is required for the electric power system of industrial plant nowadays. Arc flash incident energy and level are calculated by arc flash hazard study. The arcing fault clearing time is determined by the response time of protection devices. This paper is protection devices coordination study to reduce potential incident energy for industrial electric power system.

  • PDF

저압 배전선로의 누전 및 배선용 차단기의 오동작 방지를 위한 고속형 전기안전 보호장치 (Electric Safety Protection Device of High Speed for Incapable Operation of ELB and MCCB Using the Low Voltage Distribution Line)

  • 곽동걸;정도영
    • 전기학회논문지
    • /
    • 제56권11호
    • /
    • pp.1925-1929
    • /
    • 2007
  • This paper is studied on a novel Electric Safety Protection Device (ESPD) of high speed for incapable operation of Earth Leakage Circuit Breaker (ELB) and Molded_case Circuit Breaker (MCCB) using the low voltage distribution line. The major causes of electrical fire are classified to short circuit fault, overload fault, electric leakage and electric contact failure. The occurrence factor of the fire is electric arc or spark accompanied with electrical faults. Residual Current Protective Device (RCD), that is ELB and MCCB, of high sensitivity type used at low voltage wiring cuts off earth leakage and overload, but the RCD can't cut off electric arc or spark to be a major factor of electrical fire. As the RCDs which are applied low voltage distribution panel are prescribed to rated breaking time about 30[ms] (KS C 4613), the RCDs can't perceive to the periodic electric arc or spark of more short wavelength level. To be improved on such problem, this research development is proposed to a novel ESPD of high speed to trip of distribution line on electric arc or spark due to electrical fire. Some experimental results of the proposed ESPD are confirmed to the validity of the analytical results.

765kV 1회선 선로의 2차아크 모의결과 분석 (Analysis of Simulation Results for Secondary Arc in 765kV single transmission line)

  • 안상필;김철환;박남옥;주형준;심응보
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.36-38
    • /
    • 2004
  • In many countries, including Korea, in order to transmit the more electric power, the higher transmission line voltage is inevitable. So, a rapid reclosing scheme is important for UHV transmission lines to ensure requirements for high reliability of main lines. But, because of the high voltage and long span of UHV lines, the secondary arc current flows across the fault point even after the interruption of the fault current. i.e. A critical aspect of reclosing operation is the extinction of the secondary arc since it must extinguish before successful reclosure can occur. In Korea transmission lines, it is scheduled to energize 765kV single transmission line(79km) between Sin-Ansung S/S and Sin-Gapyeong S/S at June 2006. Therefore this paper analyzes characteristics of the secondary arc extinction on 765kV single transmission line using EMTP. Simulation results shows that the average value of the secondary arc is $30A_{rms}$ and the auto-extinction time of it is longer at closer point to Sin-Gapyeong S/S.

  • PDF

웨이브렛 변환을 이용한 철도 고압배전선로의 고장검출기법 (Fault Detection Technique in Railway High Voltage Distribution Lines using Wavelet Transform)

  • 정호성;한문섭;이장무;김주락;이한민
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 춘계학술대회 논문집
    • /
    • pp.1274-1279
    • /
    • 2004
  • This paper proposes technique to detect ground fault in railway high voltage distribution lines. Overcurrent relay technique is widely used for detecting one line ground fault that occurs most frequently in railway high voltage distribution lines. However, ground fault in distribution line is usually high impedance fault with arc. Because the fault current magnitude measured in substation is very small, the conventional overcurrent relay can't detect the high impedance ground fault. Therefore this paper proposes the advanced technique using wavelet transform. It extracts D1 component from fault signals and detects fault comparing magnitude of D1 component in each phase. To evaluate this proposed technique, we model distribution system using PSCAD/EMTDC and extract various fault data. In conclusion this technique can detect ground fault including high impedance fault regardless of fault distance, fault impedance etc.

  • PDF

지그비 네트워크 기반 복합형 AFCI 설계 및 구현 (Design and Implementation of a ZigBee Nework-based Integrated AFCI)

  • 장기흥;김기민;김재오;안현식
    • 한국인터넷방송통신학회논문지
    • /
    • 제10권4호
    • /
    • pp.41-48
    • /
    • 2010
  • 전기적 위험요소인 아크고장, 과전류, 누설전류, 온도 등을 마이크로콘트롤러를 이용하여 실시간 감시할 수 있는 복합형 AFCI(Arc Fault Circuit Interrupter, 아크고장 차단기)를 설계 구현하며, 지그비(ZigBee)기반 네트워크를 구성함으로써 아크고장에 의한 전기화재의 위험성을 예측할 수 있는 시스템을 제안한다. 복합형 아크고장 차단기는 미국의 AFCI의 인증 규격인 UL1699의 시험 조건과 KS C 규격에서 요구하는 배선용차단기와 누전차단기의 규격을 만족시키며, 검출된 전기적 위험신호들을 분류하고 전송할 수 있는 복합형 AFCI를 네트워크의 종단에 설치하고, 화재의 위험요소들의 발생 상황을 분석함으로써, 화재 위험성을 방지하기 위한 예측 시스템의 구현에 관한 연구이다.