• 제목/요약/키워드: Arc Fault

검색결과 229건 처리시간 0.026초

전압파형의 THD를 이용한 영구/일시고장 판별 적응형 재폐로 기법 (An Adaptive Reclosing Algorithm to Discriminate between Permanent Fault and Transient Fault using THD of Voltage Waveform)

  • 이철문;김철환
    • 전기학회논문지
    • /
    • 제59권8호
    • /
    • pp.1347-1352
    • /
    • 2010
  • This paper presents a new adaptive single-phase auto reclosure (SPAR) algorithm to discriminate between a permanent fault and a transient fault and to minimize a protection dead time. The algorithm precisely detects the extinction of the secondary arc, based on THD's profiles on the faulted phase voltage waveform. The EMTP/ATPDraw program was used to simulate the single phase grounding fault for evaluating the proposed algorithm. And the simulation results show that the proposed algorithm is performing well.

Two-Terminal Numerical Algorithm for Single-Phase Arcing Fault Detection and Fault Location Estimation Based on the Spectral Information

  • Kim, Hyun-Houng;Lee, Chan-Joo;Park, Jong-Bae;Shin, Joong-Rin;Jeong, Sang-Yun
    • Journal of Electrical Engineering and Technology
    • /
    • 제3권4호
    • /
    • pp.460-467
    • /
    • 2008
  • This paper presents a new numerical algorithm for the fault location estimation and arcing fault detection when a single-phase arcing ground fault occurs on a transmission line. The proposed algorithm derived in the spectrum domain is based on the synchronized voltage and current samples measured from the PMUs(Phasor Measurement Units) installed at both ends of the transmission lines. In this paper, the algorithm uses DFT(Discrete Fourier Transform) for estimation. The algorithm uses a short data window for real-time transmission line protection. Also, from the calculated arc voltage amplitude, a decision can be made whether the fault is permanent or transient. The proposed algorithm is tested through computer simulation to show its effectiveness.

장거리 송전선로를 고려한 사고거리추정 수치해석 알고리즘 (A Numerical Algorithm for Fault Location Estimation Considering Long-Transmission Line)

  • 김병만;채명석;강용철
    • 전기학회논문지
    • /
    • 제57권12호
    • /
    • pp.2139-2146
    • /
    • 2008
  • This paper presents a numerical algorithm for fault location estimation which used to data from both end of the transmission line. The proposed algorithm is also based on the synchronized voltage and current phasor measured from the PMUs(Phasor Measurement Units) in the time-domain. This paper has separated from two part of with/without shunt capacitance(short/long distance). Most fault was arc one-ground fault which is 75% over [1]. so most study focused with it. In this paper, the numerical algorithm has calculated to distance for ground fault and line-line fault. In this paper, the algorithm is given with/without shunt capacitance using II parameter line model, simple impedance model and estimated using DFT(Discrete Fourier Transform) and the LES(Least Error Squares Method). To verify the validity of the proposed algorithm, the EMTP(Electro- Magnetic Transient Program) and MATLAB did used.

아크 및 스파크 재해에 대한 누전차단기 트립을 위한 보조제어 전기안전장치에 관한 연구 - 전력용 반도체 스위칭 소자 적용 및 응용 - (A Study on Auxiliary Control Safety Apparatus for RCD Trip on Electric Arc and Spark Disasters - Using by Power Semiconductor Switching Device -)

  • 곽동걸;신미영;정도영
    • 한국화재소방학회논문지
    • /
    • 제20권1호
    • /
    • pp.71-76
    • /
    • 2006
  • 전기화재의 주된 원인은 단락 및 과부하 사고, 누전 및 접촉불량 등으로 구분되며, 화재의 발생요인은 이들 사고에서 동반되는 아크나 스파크로 인한 화재가 대다수이다. 저압배전선로에 사용되는 고감도형 누전차단기는 누전과 과부하를 검출하여 차단하는 기능은 있으나, 전기화재의 직접적인 위험요소인 아크나 스파크 현상에 대한 차단기능은 없는 것으로 분석된다. 이것은 저압 분전반에 적용되는 누전차단기의 경우 정격차단시간이 30[ms](KS C 4613)로 정해져 있어, 더욱 낮은 레벨로 주기적으로 발생되는 아크나 스파크를 감지하지 못하기 때문이다. 이러한 문제점을 개선하기 위하여 본 논문에서는 전기화재에 기인되는 아크나 스파크에 대해 누전차단기를 트립시키는 보조제어장치를 제안하고, 제안된 보조제어장치의 이론적 해석과 실험측정을 통해 그 타당성을 입증시킨다.

마이크로프로세서를 이용한 아크결함 차단기 설계 (Arc Fault Circuit Interrupter Design using Microprocessor)

  • 윤광호;반기종;이효직;박병석;남문현
    • 전자공학회논문지SC
    • /
    • 제44권1호
    • /
    • pp.12-18
    • /
    • 2007
  • 본 연구에서 설계한 AFCI는 Arc 고장 차단기로서 종속된 전기 배선상의 노화, 절연 및 배선 파괴, 연결 고장, 절연과 배선에 과도한 기계적 손상으로 인한 아크고장을 검출하여 차단하는 기능을 가지고 있으며 기존 차단기가 가지고 있던 과전류에 의한 바이메탈의 만곡 특성에 의한 동작으로 차단하는 방식은 차단에 긴 시간이 걸리나 설계한 AFCI는 전자방식으로서 과부하, 과전류에 의한 기계적 , 전기적인 스트레스를 검출하여 차단하는 기능을 가진 제품으로 차단시간이 100% 이상 단축되어 전기 화재의 발생률을 낮추도록 하였다.

배전급 전류제한 장치 효과 분석 및 도입 방안 (Effects of distribution fault current limiting apparatus and emerging applications)

  • 이방욱;박권배;김호민;오일성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 C
    • /
    • pp.1540-1541
    • /
    • 2006
  • For limitation and interruption of short circuit currents from low voltage to extra high voltage applications, the electrical equipment including fuses and circuit breakers, are widely used today. But in order to anticipate increasing needs for effective and competitive device for limiting the growing fault current in electrical power systems, fault current limitation technologies and fault current limitation devices are widely introduced and investigated in these days. Fault current limiters are emerging electric equipment which is under development using various methods including superconducting fault current limiter, solid state fault current limiter, arc driving fault current limiters. And these various methods have some advantages and disadvantages to take into considerations In order to commercialize fault current limiters in the electrical networks, a lot of discussions should be given on the point that fault current limiting methods, need for fault current limiters, coordination with existing protective system, and field experience before commercialization. In this paper, recent trends of fault current limiting technologies will be reviewed and the key issues of superconducting fault current limiters will be dealt with. And finally, future applications of superconducting fault current limiters would be discussed.

  • PDF

웨이브렛 변환과 신경망 학습을 이용한 고저항 지락사고 검출에 관한 연구 (A Study on High Impedance Fault Detection using Wavelet Transform and Neural -Network)

  • 홍대승;유창완;임화영
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제50권3호
    • /
    • pp.105-111
    • /
    • 2001
  • The research presented in this paper focuses on a method for the detection of High Impedance Fault(HIF). The method will use the wavelet transform and neural network system. HIF on the multi-grounded three-phase four-wires primary distribution power system cannot be detected effectively by existing over current sensing devices. These paper describes the application of discrete wavelet transform to the various HIF data. These data were measured in actual 22-9kV distribution system. Wavelet transform analysis gives the frequency and time-scale information. The neural network system as a fault detector was trained to discriminate HIF from the normal status by a gradient descent method. The proposed method performed very well by proving the right state when it was applied staged fault data and normal load mimics HIF, such as arc-welder.

  • PDF

SF6 가스절연 개페장치 일 (A Study on the Interrupting Capability of the Fault Current in the E.H.V. Transmission System.)

  • 강길건
    • 대한전기학회논문지
    • /
    • 제40권1호
    • /
    • pp.18-23
    • /
    • 1991
  • Recently SLAMECKA suggested the mathematical dynamic arc model of the SF6 gas circuit breaker [1]. The author applied the above dynamic arc model to the E.H.V. transmission line and investigated the interrupting capability of the SF6 gas circuit breaker. In particular the Runge-Kutta-England numerical method suitable for the use in systems that involve nonlinear dynamic arc and traveling wave was used by converting the current source into the voltage source in the DOMMEL's method [2]. The successful computer resultls were obtained and it was found that the arc time constant and the second derivative of the arc conductance are closely related to the interrupting capability of the SF6 gas circuit breaker.

  • PDF

인버터 시스템에 미치는 아크의 영향 분석 (The analysis of PWM inverter at arcing state)

  • 서현욱;변병주;임종웅;김승열;이영진;권완성;최규하
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2012년도 추계학술대회 논문집
    • /
    • pp.161-162
    • /
    • 2012
  • Arc is very serious problem in different electric fields because arc is the cause of electrical fire. In the power electronics, arc give a bad impact in power quality and reliability Therefore, in order to effectively prevent the possible damages of arc fault, this paper studies arc characteristic in power electronic system.

  • PDF

유한요소법을 이용한 배선용 차단기의 아크소호 성능향상에 관한 연구 (A Study on Improving Arc Quenching Performance of MCCB by FEM)

  • 김길수;임기조;강성화;조현길;이강원;박정남
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 연구회
    • /
    • pp.51-54
    • /
    • 2001
  • This Paper is described basic principles of arc quenching in Molded Case Circuit Breaker. We analyzed magnetic blowout forces acting on the arc in contact system when circuit breakers interrupt fault currents in different three models by 3-D FEM(Finite Element Method). The interrupting time simulated is compared with that of short circuit tests. The results of this study derive valid of the simulation method and present the techniques to improve arc quenching performance.

  • PDF