• Title/Summary/Keyword: Arc Chamber

Search Result 143, Processing Time 0.054 seconds

New Arc Chamber to Improve Breaking Capacity (차단용량 향상을 위한 신소호 구조)

  • Park, Jin-Young;Cho, Hea-Yong
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.2
    • /
    • pp.321-326
    • /
    • 2012
  • The mechanism unit, arc chamber and trip unit are imperative components of MCCB which will decide the level of performance of MCCB. Among them, Arc chamber unit is used for extinguishing arc rapidly of fault current and induce the arc inside of grid. At that time inducing arc will split into parts and cooled rapidly so the arc would disappear. This paper suggests new arc chamber unit to improve arc extinguishing performance with optimum design and are applied to actual products based on the results.

Influence of Contact and Wall Material on Arc Interruption in Air (기중 아크 차단에 대한 접점 및 소호 재료의 영향)

  • Lee, S.Y.;Park, H.T.;Oh, I.S.;Lee, K.H.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1637-1639
    • /
    • 2001
  • Air arc interruption used in low rated voltage breaker, ACB and MCCB, have used the arc chamber composed of metal plates and insulating laminates which supposed these mechanically. and geometry and materials of arc chamber are very different by breaker manufacturer. These breakers have required to be smaller and to interrupt higher current by user. therefore the arc chamber geometry and material in breaker have been small, complex and various. The purpose of this study is to examine the effects of insulating laminates and contact materials on air arc interruption. Contacts were surrounded by a rectangle chamber of insulating laminates. Contact concoctions were composed of AgW, AgCdO that have used in low rated voltage breaker, and insulating laminates were polyester, epoxy. We found strong dependance of arc voltage on insulating material. The ablated vapor on polyester increased arc voltage that was useful in air arc interruption.

  • PDF

Investigation of Arc Breaking Characteristic for Arc Chamber in Molded Case Circuit Breakerg (배선용차단기의 소호구조에 의한 한류 특성 연구)

  • Kim, Yong-Gi;Song, Jung-Chun;Ryu, Man-Jong
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.708-710
    • /
    • 2001
  • In this paper, back commutation phenomena for iron chute chamber in AC low testing. For this experimental we used high speed camera and carried out with same prospective currents up to 10kA RMS. Hybrid arc quenching chambers which are composed with iron plate and insulating materials tested for reducing back commutation phenomena in interrupting process. It is shows that hybrid chambers which are various narrow slot path width reduces back commutation. As a result, a new type arc quenching chamber is to force the arc rapidly into a narrow insulating slot with iron plate. By this means the arc is lengthened and squeezed between insulating walls. Using this model, the behavior of the arc squeezed in the hybrid chamber and characteristics of arc voltage are also investigated.

  • PDF

Study on the Flow and Mass Transfer in a PASB Arc Plasma Chamber (PASB 아크 플라즈마 챔버에서 발생하는 유동 및 물질전달에 관한 연구)

  • Lee, Jong-Chul;Kim, Youn-J.
    • The KSFM Journal of Fluid Machinery
    • /
    • v.11 no.4
    • /
    • pp.7-13
    • /
    • 2008
  • The computational investigation is performed to find out the interaction of arc plasmas with surrounding materials and the thermal flow characteristics in a PASB (Puffer-Assisted Self-Blast) chamber, which is one of new breaking concepts in $SF_6$ switchgears. It is very important to define the flow and mass transfer happened during the full arcing history for further understanding complex physics inside the chamber. In this study, we have considered two diffusion processes by the hot arc plasma, one is PTFE nozzle ablation and the other is Cu electrode evaporation, simultaneously. It was found that the principle of the pressure-rise inside the chamber is confirmed by the computational results and the increase of the electrical conductivity of the residual gas near current zero is critical to the chamber design.

Calculation of Pressure Rise in a Thermal-expansion Type Arc Chamber (열팽창 분사식 가스차단부의 소호실내 압력상승 계산)

  • Choi, Y.K.;Oh, Y.H.;Shin, Y.J.;Park, K.Y.;Kim, H.J.;Choulkov, V.V.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07a
    • /
    • pp.167-169
    • /
    • 1998
  • Recently $SF_6$ gas circuit breakers utilizing the thermal-expansion principle are increasingly used in distribution power system. Active researches and developments have been conducted to reduce the size and weight, and to improve the interrupting performance of the circuit breakers. It was first developed a programme which could show the hot gas flowing into the thermal-expansion arc chamber. This programme, using so-called FLIC method basically, adopted 'Simplified Enthalpy Arc Model' which was somewhat modified to estimate the arc quenching process. The computation by it was compared with the measured results of the pressure rise in the chamber, and both showed fairly good agreement.

  • PDF

A Study of the Arcing History in a Thermal Puffer Plasma Chamber with a Coupled Simulation (연성해석을 통한 열파퍼 플라즈마 챔버의 아크현상 이력에 관한 연구)

  • Lee, Jong-Chul;Heo, Joong-Sik;Kim, Youn-Jea
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2506-2511
    • /
    • 2007
  • The coupled simulation is performed to find out the interaction of arc plasmas with surrounding materials in a thermal puffer plasma chamber. In order to be more realistic, PTFE nozzle ablation and Cu electrode evaporation, which are caused by high temperature of arc plasmas, are considered together. Pressure rise and temperature inside the chamber generated during the whole arcing history are investigated with the applied currents. It is very important to define how thermal flow and mass transfer are processing between the arc plasma and surrounding materials for further understanding complex physics inside the chamber. It is concluded that the result might be very useful to understand the mechanism happened inside and to design thermal puffer plasma chambers, but further experimental studies are required to verify the results for the more practical applications.

  • PDF

Arc Ion Plating Deposition System의 Bias 종류에 따른 TiN 박막의 특성평가

  • Kim, Wang-Ryeol;Park, Min-Seok;Kim, Dae-Yeong;Kim, Hyeon-Seung;Gwon, Min-Cheol
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.208-208
    • /
    • 2012
  • 최근 환경문제가 많이 제기되면서 친환경적 운송수단인 자전거 개발과 관련하여 다양한 기술개발이 이루어지고 있다. 그 중 고부가가치의 서스펜션 포크의 프레임에 고기능성 표면처리로 Arc ion plating deposition system (AIPDS)을 이용하여 부식, 내마모 특성이 뛰어난 TiN 박막을 증착시켰다. AIPDS는 기존의 arc system과 달리 다원계 소재 코팅 공정조건 확립을 위하여 chamber wall에 2개의 rectangular type sputter source를 장착하고 소재의 pre-treatment 용 linear type ion source를 설치하였다. 장비의 Chamber 중앙에는 pipe형 arc cathode를 설치하였으며, 그 주위를 anode 역할을 하는 copper 코일로 감아 이는 발생한 arc를 target인 cathode 축을 중심으로 방향성을 가지고 회전하여 진행 할 수 있도록 유도 하였다. 이 시스템에서 증착된 TiN 박막은 bias 전압 변화에 따른 박막의 구조 및 물성을 평가하였다. XRD 장비를 통하여 TiN 박막의 상분석을 진행하였고, 마모테스터, 원자현미경, 마이크로 비커스 경도기 등을 이용하여 기계적 특성을 평가하였다.

  • PDF

STUDY ON NUMERICAL ANALYSIS AND TURBULENCE MODELS FOR ARC DISCHARGES IN HIGH-VOLTAGE INTERRUPTERS (초고압 차단부 아크방전 수치해석 및 난류모델에 관한 연구)

  • Lee, J.C.
    • Journal of computational fluids engineering
    • /
    • v.15 no.3
    • /
    • pp.9-15
    • /
    • 2010
  • In this study, we calculated arc discharges and flow characteristics driven by arcs in a thermal puffer chamber, which is one of most outstanding high-voltage interrupters, for understanding the complex physics and the probability of thermal breakdown. The four main parts of arc model for this virtual-reality are radiation, PTFE ablation, Cu evaporation, and turbulence. Among these important parts the turbulence model can be critical to the reliability of computation results during the whole arcing history because the plasma flow is affected by high heat energy and mass momentum. Two turbulence models, the Prandtl's mixing length model and the standard $k-\varepsilon$ model, are applied for these calculations and are compared with pressure-rise inside chamber and arc voltage between the contacts as well as flow characteristics near current zero.

3-D Finite Element Analysis of Magnetic Force on the Arc for Design of Arc Chamber or Molded Case Circuit Breaker (배선용 차단기의 소호실 설계를 위한 Arc의 자기구동력의 3차원 해석)

  • Song, Hee-Chan;Son, Jong-Man;Kang, Sung-Wha;Lim, Kee-Joe
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1536-1540
    • /
    • 1996
  • The Design of are quenching parts of molded case circuit breakers depends on the utilization of strength and distribution of the magnetic field by which the arc is forced. The magnetic field causes the are to move into a set of V-slotted iron grids, where the are is extinguished rapidly. This paper present the effective method 10 design V-slotted iron plates of the are breaking chamber of molded case circuit breakers. This magnetic force was calculated by using the flux densities in the arc which are obtained by three dimensional finite element method, as a result of that this paper verified by testing that a grid model which has biggest magnetic force is excellent in the are quenching ability.

  • PDF

Mathematical Modelling of $SF_6$ Puffer Circuit Breakers I : High Current Region ($SF_6$ 파퍼차단기의 수학적 모델링 I : 대전류 영역)

  • Park, K.Y.;Park, J.H.;Shin, Y.J.
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.640-644
    • /
    • 1993
  • A mathematical arc model based on the integral method has been developed to study the arc behaviour of $SF_6$ Puffer circuit breakers during high current period. The interaction between the compression chamber and the arc interrupter plays a critical role in determining the arc behaviour. Computations have been carried out for the puffer circuit breaker of Noeske et al.[1]. The aerodynamic behaviour and electrical characteristics of the puffer circuit breaker have been investigated. In addition, the pressure rise in the compression chamber and arc voltage have been computed and the results compared with the available experimental results of Noeske et al.[1]. Special attention has been paid to the presence of the shock.

  • PDF