• Title/Summary/Keyword: Aqueous Absorbents

Search Result 26, Processing Time 0.027 seconds

Absorption Properties of $CO_2$ in Aqueous Solutions of Piperazine, Piperidine, Cyclohexylamine (Piperazine, Piperidine, Cyclohexylamine 수용액에 대한 이산화탄소의 흡수특성)

  • Song Ho-Jun;Lee Seoungmoon;Song Hocheol;Ahn Se-Woong;Park Jin-won
    • Journal of Energy Engineering
    • /
    • v.14 no.4 s.44
    • /
    • pp.219-225
    • /
    • 2005
  • for the removal of carbon dioxide in flue gas, which is the main cause of the global warming, chemical absorption methods were widely used for years. Alkanolamines such as MEA, AMP, MDEA are mainly used as an absorbent. In this study, cyclic amines - Piperazine, Piperidine and Cyclohelylamine are investigated to compare the chemical solubilities, absorption capacities and rate ot reaction. In conclusion, Piperazine is the most effective absorbent of $CO_2$ and ran be the excellent alternative to the former absorbents. Experiments were performed at 5, 10, 15 weight percent, 30, 40, $50^{\circ}C$, and the gas solubilities are determined by back-titration method, and using Gas Chromatography the absorption rate was compared.

A Study on the Absorption of Carbon Dioxide using PVDF/Plasma Membrane Contactor (PVDF/플라즈마 막접촉기를 이용한 이산화탄소의 흡수에 관한 연구)

  • Choi, Seung-Hak;Gao, Tongzhai;Oh, Sae-Joong
    • Korean Chemical Engineering Research
    • /
    • v.43 no.1
    • /
    • pp.161-169
    • /
    • 2005
  • Numerical simulation and experiments were carried out on the absorption of carbon dioxide using PVDF hollow-fiber membrane contactor. Water or monoethanolamine (MEA) aqueous soluton was used as absorbents. Simulation results showed that the concentration profile of carbon dioxide was less affected by the flow rate of MEA than that of water absorbent. The absorption rate and mass transfer coefficient of carbon dioxide increased as the concentration of MEA increased. The mass transfer coefficients obtained by experiments coincided with those obtained by numerical simulation and theoretical results for $CO_2-water$ system. However, for $CO_2-MEA$ system, the mass transfer coefficients obtained by experiments were lower than those obtained by simulation, while the simulation results agreed well with theoretical results. The durability of plasma-treated hollow fiber membranes was better than that of no plasma-treated ones.

Removal of Synthetic Heavy Metal ($Cr^{6+}$, $Cu^{2+}$, $As^{3+}$, $Pb^{2+}$) from Water Using Red Mud and Lime Stone (적니와 석회석을 이용한 혼합 중금속($Cr^{6+}$, $Cu^{2+}$, $As^{3+}$, $Pb^{2+}$)의 제거)

  • Kang, Ku;Park, Seong-Jik;Shin, Woo-Seok;Um, Byung-Hwan;Kim, Young-Kee
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.8
    • /
    • pp.566-573
    • /
    • 2012
  • This study examined the removal rate of heavy metals from synthetic control water using red mud and lime stone. Overall, the percent of absorption obtained in this study for the red mud treatment was 94.0% ($Pb^{2+}$), 67.1% ($As^{3+}$), 37.5% ($Cu^{2+}$), and 36.6% ($Cr^{6+}$), while that of lime stone was $Pb^{2+}$ (30.8%), $Cu^{2+}$ (16.5%), $Cr^{6+}$ (11.5%), and $As^{3+}$ (8.9%). The kinetic data presented that the slow course of adsorption follows the Pseudo first and second order models, the equilibriuim adsorption of $Cr^{6+}$ and $Pb^{2+}$ obeys Freundlich isotherm model, while the adsorption of $Cu^{2+}$ obeys only Langmuir model. The results also showed that adsorption rate slightly increased with increasing pH from 5 to 9. Interestingly, this trend is similar to results obtained as function of loading amount of red mud. Meanwhile, an unit adsorption rate was slightly decreased. For lime stone, it did not much change in adsorption as function of treatment amount. Consequently, it was concluded that the absorbents can be successfully used the removal of the heavy metals from the aqueous solutions.

A Study on the CO2 Removal Efficiency with Aqueous MEA and Blended Solutions in a Vortex Tube Type Absorber (Vortex Tube 형 흡수장치에서 MEA와 혼합흡수용액을 이용한 CO2 제거 효율 고찰)

  • Ryu, Woo-Jung;Han, Keun-Hee;Choi, Won-Kil;Lee, Jong-Sub;Park, So-Jin
    • Korean Chemical Engineering Research
    • /
    • v.47 no.6
    • /
    • pp.795-800
    • /
    • 2009
  • In this study, the $CO_2$ removal characteristics of the Vortex tube type absorbtion apparatus were investigated to enhance the compactness of $CO_2$ absorption process and to reduce the amount of absorbing solution of the $CO_2$ separation process. The Vortex tube with the diameter of 17 mm and the length of 250mm was introduced in the experimental apparatus to treat $20Nm^3/hr$ of $CO_2$ containing flue gas. The flue gases for experiments containing 11~13 vol% of $CO_2$ were supplied from the coal-firing CFBC power plant with 12 ton/hr of steam producing capacity. The mixed solutions of 20 wt% of MEA as base solution with the adding solutions like HMDA, AMP and KOH were used as absorbents. The experiments were executed under the various conditions like the absorbing solution concentrations in the range of 20 to 50 wt%, the flow rate of $CO_2$ containing flue gases in the range of 6 to $15Nm^3/hr$ and the flow rate of absorbing solution in the range of 1.0 to 3.0 l/min. As a results, the $CO_2$ removal efficiency of mixed absorbent of 20 wt% of MEA with HMDA was remarkable. From this study, we concluded that the efficient separation of $CO_2$ from flue gases using the features of the Vortex tube type absorbing unit for gas/liquid contact and the separation of gas/liquid be possible. But more works are needed to increase the $CO_2$ removal efficiency of Vortex tube process.

The Uptake of Lead Ion with Staphylococcus epidermidis (Staphylococcus epidermidis 를 이용한 납 이온의 축적에 관한 연구)

  • 김종혜;김말남
    • Korean Journal of Microbiology
    • /
    • v.30 no.4
    • /
    • pp.310-315
    • /
    • 1992
  • Absorption of $\textrm{Pb}^{2-}$ from aqueous solution was studied using Staphylococcus epidermidis. Cells of exponential phase were employed as absorbents. Uptake ratio defined as the ratio of amount of $\textrm{Pb}^{2+}$ absorbed to that of initial $\textrm{Pb}^{2+}$. Absorption of $\textrm{Pb}^{2+}$ increased with increase in cell concentration. while amount of $\textrm{Pb}^{2+}$ per unit cell mass decreased. Uptake ratio of $\textrm{Pb}^{2+}$ augmented and then diminished after exhibiting a maximum as the pH of the solution increased. Equilibrium absorption of $\textrm{Pb}^{2+}$ deviated from Freundlich isotherm especially at higher concentration of $\textrm{Pb}^{2+}$ due to the precipitation phenomena. HCI and EDTA were founded to desorb $\textrm{Pb}^{2+}$ more effectively than $\textrm{Na}_{2}\textrm{CO}_{3}$ or $\textrm{NaHCO}_{3}$. After 10 cycles of absorption and desorption. $\textrm{Pb}^{2+}$ absorption capability remained almost unchanged and the biomass had leaked out 30-40 wt/%. Uptake ratio of Pb2+ decreased in the presence of other heavy metal ions due to the competitive absorption The inhibition of $\textrm{Pb}^{2+}$ absorption appeared to have a strong correlation with ionic radius of the competing ions. Especially $\textrm{Cr}^{3-}$, $\textrm{Co}^{2+}$ or $\textrm{Fe}^{2+}$ having smaller ionic radius depressed more significantly the uptake of $\textrm{Pb}^{2+}$ than any other metal ions tested.

  • PDF

Characteristics of $CO_{2}$ Absorption and Degradation of Aqueous Alkanolamine Solutions in $CO_{2}$ and $CO_{2}-O_{2}$ System ($CO_{2}$$CO_{2}-O_{2}$ 시스템에서 알카놀아민류 흡수제를 이용한 $CO_{2}$ 흡수 및 흡수제 열화 특성)

  • Choi, Won-Joon;Lee, Jong-Seop;Han, Keun-Hee;Min, Byoung-Moo
    • Korean Chemical Engineering Research
    • /
    • v.49 no.2
    • /
    • pp.256-262
    • /
    • 2011
  • Amine can undergo irreversible reactions by $O_{2}$ and high temperature in amine scrubbing process and these phenomena are called "degradation". Degradation causes not only a loss of valuable amine, but also operational problems such as foaming, corrosion and fouling. In this study, using various chemical absorbents(MEA; monoethanolamine, AMP; 2-amino-2-methyl-1-propanol, DAM; 1,8-diamino-p-menthane), we examined the following variable. I) loading ratio of $CO_{2}$ at $50^{\circ}C$ and $120^{\circ}C$, ii) concentration variation and initial degradation rate constant of absorbent in $CO_{2}$ and $CO_{2}/O_{2}$ system, and iii) effect of degradation by $O_{2}$. The $CO_{2}$ loading of 20 wt% DAM was 400% and 270% higher than that of 20 wt% MEA and AMP at 50, respectively and was the largest the difference of $CO_{2}$ loading between absorption $(50^{\circ}C)$ and regeneration $(120^{\circ}C)$ condition. The initial degradation rate constant of 20 wt% DAM was $2.254{\times}10^{-4}cycle^{-1}$ which was slower than that of MEA $(2.761{\times}10^{-4}cycle^{-1})$ and AMP $(2.461{\times}10^{-4}cycle^{-1})$ in $CO_{2}$ system. Also, it was increased 30% by $O_{2}$ that effects on the degradation by $O_{2}$ was less than 100% increased. these degradation reactions was able to identify by formation of new peak in GC and FT-IR spectrum analysis.