• 제목/요약/키워드: Applied pressure

Search Result 6,708, Processing Time 0.035 seconds

Temperature, Electric Field, Pressure Dependency and Dielectric properties on the interface between XLPE and EPDM (XLPE와 EPDM의 계면에 따른 유전특성과 온도, 전계, 압력의존성)

  • 김동식;박대희
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.11a
    • /
    • pp.109-111
    • /
    • 1997
  • In this paper, we have evaluated temperature, electric field, Pressure dependency and dielectric properties of EPDM XLPE and EPDM/XLPE\`s interface. Temperature dependency of EPDM had great influence with dielectric properties, but pressure and applied voltage of EPDM had no effect on dielectric properties. Dielectric properties of XLPE were influenced by not only temperature but also pressure and applied voltage. We knowed that dielectric properties of EPDM/XLPE were trended toward tendency of those of EPDM

  • PDF

Novel Three-Dimensional Knitted Fabric for Pressure Ulcer Prevention: Preliminary Clinical Application and Testing in a Diabetic Mouse Model of Pressure Ulcers

  • Kim, Sungae;Hong, Jamin;Lee, Yongseong;Son, Daegu
    • Archives of Plastic Surgery
    • /
    • v.49 no.2
    • /
    • pp.275-284
    • /
    • 2022
  • Background Population aging has led to an increased incidence of pressure ulcers, resulting in a social burden and economic costs. We developed a three-dimensional knitted fabric (3-DKF) with a pressure-reducing function that can be applied topically in the early stages of pressure ulcers to prevent progression. Methods We evaluated the effects of the 3-DKF in a streptozotocin-induced diabetes mellitus pressure ulcer mouse model, and the fabric was preliminarily applied to patients. Twelve-week-old male C57BL/6 mice were used for the animal experiments. In the pressure ulcer mouse model, an ischemia-reperfusion injury was created using a magnet on the dorsa of the mice. Pressure was measured with BodiTrak before and after applying the 3-DKF to 14 patients at risk of sacral pressure ulcers. Results In the 3-DKF-applied mice group, the ulcers were shallower and smaller than those in the control group. Compared with the mice in the control group, the 3-DKF group had lower platelet-derived growth factor-α and neutrophil elastase expression, as parameters related to inflammation, and increased levels of transforming growth factor (TGF)-β1, TGF-β3, proliferating cell nuclear antigen, and α-smooth muscle actin, which are related to growth factors and proliferation. Additionally, typical normal tissue staining patterns were observed in the 3-DKF group. In the preliminary clinical analysis, the average skin pressure was 26.2 mm Hg before applying the 3-DKF, but it decreased to an average of 23.4 mm Hg after 3-DKF application. Conclusion This study demonstrated that the newly developed 3-DKF was effective in preventing pressure ulcers through testing in a pressure ulcer animal model and preliminary clinical application.

Study on the Difference of Pulse Waveform Parameter with Applied Variations of Pressure (측정가압에 의한 좌관부위(左關部位) 맥파요인 변화에 대한 실험 연구)

  • Kim, Gyeong-Cheol;Lee, Jeong-Won;Ryu, Kyeong-Ho;Kang, Hee-Jung;Yim, Yun-Kyoung
    • Korean Journal of Acupuncture
    • /
    • v.27 no.4
    • /
    • pp.59-72
    • /
    • 2010
  • Objectives : In the study on the waveform analysis of radial artery pulse diagnosis, we need to establish fundaments of contemporary pulse diagnosis research, and to find the change of pulse waveform parameter with applied variation pf pressure. Methods : As we will to do experimental research on the difference of pulse waveform on the radial artery with applied variations of pressure(5 stage-pressure) and measuring position(left KWAN). In this research, we analyzed the change of the waveform according to five stage pressure. Results : The results were as follows; When we analyzed the change of the waveform according to pressure in the left KWAN, E, hl, h2 and A were the difference between 8ths pressure grades in 95% trust section. And t2, t4 were the difference between 8ths pressure grades in 95% trust section. W was the difference between 8ths pressure grades in 95% trust section. And h2/h1 was the difference between 6ths pressure grades in 95% trust section. There is the difference between 1st and 2nd grade & between 2nd and 5th grade in the case of t4/t2 in 95% trust section. And there is the difference between 1st and 5th grade, between 3rd and 4th grade, between 3rd and 5th grade & between 4th and 5th grade in the case of W/A in 95% trust section. And there is the difference between 1st and 2nd grade, between 2nd and 3rd grade, between 2nd and 4th grade, between 3rd and 4th grade, between 3rd and 5th grade & between 4th and 5th grade in the case of A/E in 95% trust section. Conclusions : We found the statistically resonable differences between each pulse depending on the applied pressure. And Analysing the radial pulse(left KWAN) at 5 applied pressure levels may be useful to study on the pulse waveform diagnosis.

A study on wiry pulse in hypertensive patients analyzed at 5 levels of applied pressure using 3 dimensional pulse imaging analyzer (3차원 로봇 맥 영상 분석기의 5단계 가압 맥파 분석에 의한 고혈압 환자의 현맥(弦脈) 연구)

  • Kang, Hee-Jung;Kwon, Young-Sang;Kim, Dal-Lae;Kim, Kyung-Cheol;Yim, Yun-Kyoung
    • Korean Journal of Acupuncture
    • /
    • v.27 no.1
    • /
    • pp.1-12
    • /
    • 2010
  • Objectives: The purpose of this study is to gain the objective indicators for the classification of hypertension by oriental medical pulse diagnosis, through finding out the parameters which can distinguish the pulse of hypertensive patient from that of normal subject, and characterizes the wiry pulse of hypertension. Methods: 30-59 yr, male, 946 healthy volunteers and 35 hypertensive patients were enrolled in this study. All the hypertensive patients were taking medicine to control the blood pressure and the blood pressure of the hypertension group was not statistically different from that of the normal healthy group. Data were acquired using 3 dimensional pulse imaging analyser(DMP-3000, DAEYOMEDI, KOREA) and analysed according to the age bands and the applied pressure levels. Results: 1. RAI/t, w/t and t2/t decreased with the levels of applied pressure and increased with age in the normal healthy group, not in the hypertension group. 2. RAI/t, w/t, t2/t were significantly higher in the hypertension group than the normal healthy group in the 30-age band, and elasticity coefficient was higher in the hypertension group than the normal healthy group in the 40-age band. 3. Researches on the patients without hypotensive agents are needed to figure out whether these parameters are the components of hypertensive wiry pulse. Conclusions: Analysing the radial pulse at 5 applied pressure levels using 3 dimensional pulse imaging analyser may be useful to differentiate the pulses of the hypertensive patients from those of the normal subjects, and characterize the hypertension.

Analysis of SF6, N2 Pressure Characteristic of Spark Gap According to Simulation (시뮬레이션을 통한 스파크갭의 SF6, N2 압력 특성 분석)

  • Choi, Sun-Ho;Lee, Tae-Woo;Bang, Jeong-Ju;Huh, Chang-Su
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.27 no.3
    • /
    • pp.172-177
    • /
    • 2014
  • Industrial, medical, environment and agriculture application of pulse power technology have been developing rapidly in many field. In order to make use in the form of pulses is applied to the pulse forming technique. At this time, spark gap is generally used for the pulse forming. Spark gap may be possible to simulate the shape of the electrode, to know the uniform or non-uniform electric field of the electrode structure. Further, it can be determined using Paschen's law applied pressure of the insulating gas in accordance with the voltage which is created using the value of the electric field. In this paper, we tried to found using a formula and the simulation process to determine the pressure. The value of the electric field is different according to the shape of the electrode. So, the range of pressure applied also varies. In order to withstand the 100 kV with a gap of 5 mm, the nitrogen gas must be applied to about 7 bar in the electrode structure. On the other hand, in the same conditions, Sulfur hexafluoride gas must be applied to about 2 bar. Consequently, the Sulfur hexafluoride gas has a higher insulation properties than nitrogen gas may be applied to low pressure at the same conditions.

Studies on Garment Restraint(I) -Change of Skin Temperature by Continuous Restraint Method- (의복의 구속성에 관한 연구(I) -지속적인 구속방법에 따른 피부온 변화에 대하여-)

  • 심부자
    • Journal of the Korean Home Economics Association
    • /
    • v.29 no.1
    • /
    • pp.13-25
    • /
    • 1991
  • We measured change of peripheral skin temperature and mean skin temperature when the upper arm and thigh are pressured in order to know the effect of skin pressure applied by clothing on blood circulation. After release from pressure, we observed also recovery condition. At the same time, we examined relation between pressure and a feeling of thightness. Three physiques of healthy females, namely slender, standard and plump, served as subjects. We used continuous restraint method with skin pressure applied by experimental fabric for 10 min. As a result of this experiment, we obtained following findings. 1. The significant difference was marked at the pressure, measuring time and physique with change of skin temperature under upper arm restraint. The peripheral and mean skin temperature decreased with the lapse of restraint time. A remarkable tendency observed according to the increase of restraint pressure. Recovery condition after release from pressure not yet recovered to original state, for all after a lapse of 10 min. 2. The significant difference was marked at the pressure, measuring time and physique with change of skin temperature under thigh restraint, especially different physique was remarkable among them. The peripheral skin temperature decreased or decreased. Recovery condition after release from pressure was the same upper arm. 3. Main factor affecting the evaluation of a feeling of tightness was restraint pressure. The value of pressure sensation made remarkable declined after a lapse of 10 min restraint time. Individual differences, however, were shown in pressure sensation.

  • PDF

Compression and Dewatering of Chinese Cabbage (배추의 압축탈수특성에 관한 연구)

  • Kim, Y.J.;Lee, D.H.;Lee, Y.B.
    • Journal of Biosystems Engineering
    • /
    • v.19 no.1
    • /
    • pp.3-8
    • /
    • 1994
  • An experiment on the expression and dewatering of chinese cabbage was conducted in order to investigate its dewatering behavior. Chopped cabbage was packed into cylinder and pressed by piston upto the predetermined pressure on Instron-1000. The rates of dewatering were affected domintantly by the applied pressure, but not significantly by the packed amount of cabbage in the cylinder. The pressure effect was increased very abruptly at first, but the increase rate was very low at high pressure greater than 20 MPa, showing great deviation from linear dependence of flow rate on pressure in Darcy's Law. Therefore, water expression from cabbage was not Newtonian flow of water through cell wall. In fact, the squeezed water contained a lot of solid particles, about 3% of solid cabbage particles, showing destruction of cell wall. It appeared that compression and dewatering of vegetable wastes in the low pressure. under 20 MPa, is more desirable for later treatment of the dewater. More researches are needed in order to develop a treatment method for the solid particles in the expressed water before an expeller treatment system can be applied to vegetable wastes.

  • PDF

Collapsible Phenomena in the Flexible Tubes due to the Flow Rate and Transmural Pressure Changes (유량과 벽면횡단압력의 변화에 의한 유연한 관의 압착현상)

  • Cho, Min-Tae;Suh, Sang-Ho;Yoo, Sang-Sin
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.377-380
    • /
    • 2000
  • The collapsible phenomena of the circular tubes due to the excessive transmural pressure are investigated experimentally. Collapsible tubes are installed in the test section where the external pressure is applied to the test tubes by applying the hydrostatic head. The collapsible circular tubes are made of rubber, whose diameters are 6 and 4.2 mm, respectively. The hydrostatic water head of the upper reservoir is applied to the test section. Pressures at the upstream and downstream sides are measured by the pressure transducers. The collapsible phenomena are observed as the transmural pressure Increases, and also the flutter phenomenon occurs due to the critical transmural pressure.

  • PDF

PSP Pressure Field Visualization of an Oblique Impinging Jet (경사충돌제트의 PSP 압력장 가시화)

  • Kang Jong Hoon;Lee Sang Joon
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2004.11a
    • /
    • pp.10-13
    • /
    • 2004
  • The PSP(pressure sensitive paint) technique has recently received a large attention as a new revolutionary optical method to measure absolute pressure distribution on a model surface. The PSP technique can be applied to quantitatively investigate flow structure using a CCD camera and image processing technique. In the static calibration, the luminescent intensity of PSP coatings was measured from 0kPa to 11kPa with 0.5, 1, 2kPa increments. In this study, the low-pressure PSP technique was applied to an oblique impinging jet to measure pressure field variations on the impingement plate with varying angle of an oblique jet. The flow structure over the impingement plate was visualized using a surface tracing method. As a result, the detail pressure field distributions of the oblique low-speed impinging jet were visualized effectively using the PSP technique.

  • PDF

Analysis on the Train-wind Pressure applied to Screen Door in Island-type Platform of Subway (지하철의 섬식 정거장에 설치된 스크린도어에 가해지는 열차풍압 해석)

  • Kim, Jung-Yup
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.138-141
    • /
    • 2008
  • The screen doors installed in the station of subway are subject to the train-wind pressure caused by the operation of trains. The train-wind pressure has to be correctly estimated for the design of safe structure of screen doors. As three-dimensional numerical flow analysis technology has been significantly developed, the analysis on the train-wind pressure with diverse variables such as train specifications, train speed, tunnel and station configurations, and blockage ratio can be effectively carried out with three-dimensional numerical method. In this study, computational analysis of train-induced wind in a subway tunnel employing the screen doors are carried out by using the three-dimensional numerical method with the model of the moving boundary for the run of trains. While the numerical analysis of train-wind pressure was applied on the one island-type station in the Seoul Subway Line 2, maximum pressure of 494 Pa was estimated on the screen door when two trains pass each other at the speed of 80km/h in the platform.

  • PDF