• 제목/요약/키워드: Application-SoC

검색결과 914건 처리시간 0.034초

Study on the Simulation of Heat Pump Heating and Cooling Systems to Resident Building (숙박업소 건물의 히트펌프 냉난방 시스템 적용을 위한 시뮬레이션 연구)

  • Choi, Young-Don;Han, Seong-Ho;Cho, Sung-Hwan;Kim, Du-Sung;Um, Chul-Jun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • 제20권1호
    • /
    • pp.65-74
    • /
    • 2008
  • In Korea, air source heat pump system is less efficient than conventional heat source facilities, such as ground source, river water, because the air temperature in winter season is so low that COP of air source heat pump system drops below 3.0. Therefore, the study on the application of heat pump heating and cooling systems is crucial for the efficient popularization of heat pump. In this work, we present the dynamic analysis of energy consumption for the large resident building by heat resistance-capacitance method. The system simulation of water storage air source heat pump is additionally performed by changing of sizes and locations of the hospital building. The computed results show that energy cost of water storage air source heat pump is low, so it is more economical than absorption chiller & heater.

Expansion Factors of Cement Mortar Containing Expanding Admixture (팽창재를 포함한 시멘트 모르터의 팽창 요인)

  • 황인동;염희남;정윤중
    • Journal of the Korean Ceramic Society
    • /
    • 제37권6호
    • /
    • pp.576-582
    • /
    • 2000
  • Two type of expanding cement generally referred to as CSA with Hauyne(3CaO 3Al2O3 CaSO4) and Quick lime(CaO). Hauyne is formed to ettringite when there are presented with CaO and CaSO4, and CaO reacts wtih water to form Ca(OH)2. REcently, the mechanism of compensation and expand mortar or concrete tend to same and it has been used improving on its shrink property. The volume of cement paste varies with its water content shrink with drying and re-wetting. Concrete and mortar works are required shrinking compensation and expansion properties to reduce of potential crack. The use of expansion cement may improve on its shrinking volume changes. CSA dosages for shrinking compensation limited by cement weight, but obtained difference expansion rate with varied W/C or inorganic admixture. This paper studies expansion rate according to expansion cement dosages, water and inorganic admixtures as Silica fume. Therefor, the expansion factor has to considered before the application.

  • PDF

A Study on Ozone Passive Sampler (II) -Interference and Field Application (오존간이 측정기에 대한 연구(II)-간섭현상 및 현장 적용성)

  • Jeong, Sang-Jin;Yang, Hee-Jun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제22권6호
    • /
    • pp.904-911
    • /
    • 2006
  • Passive sampler is simple and inexpensive measuring equipment for air pollution. In this study we developed colorimetric ozone passive sampler which was coated a colorimetric reagent to a filter substrate. Interference of criteria all pollutant ($SO_2,\;NO_2,\;CO$) on ozone passive sampler was investigated through experimental chamber. Field measurement of developed ozone passive samper was compared automatic sampler result in Suwon area. The results shows interference of $SO_2$ gas is larger than other gases. Developed passive sampler can be roughly applicable to wind speed range from 0.8 to 3.3 m/s, temperature range from 3.9 to $27.5^{\circ}C$ and relative humidity range from 48 to 84%.

A Study on Design of Controller Gain for PWM Converter (PWM 컨버터 제어기 이득의 해석적 설계)

  • Gho J.S.;Cho J.S.;Kang B.H.;Choe G.H.;Kwak C.H.;Chung S.E.
    • Proceedings of the KIPE Conference
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.491-495
    • /
    • 2001
  • Compare with diode or thyristor bridge AC/DC converter, the 3 phase PWM converter has some merits of low THD and unit power factor. So, in many critical application like as UPS, using PWM converter is the trends. 3 phase PWM converter had been studied widely already. But analytical design procedure can not found from publication for hardware design and controller design. So, in this paper, 3 phase PWM converter analysis review was given. And from the DC analysis result, parameter design was done. From the AC model, the voltage controller and current controller was designed. The gain of controllers was calculated by analytical method.

  • PDF

Design and Implementation of Fire Management Components

  • Kim, K.S.;Park, J.H.;Lee, J.H.
    • Proceedings of the KSRS Conference
    • /
    • 대한원격탐사학회 2003년도 Proceedings of ACRS 2003 ISRS
    • /
    • pp.600-602
    • /
    • 2003
  • In Korea, fire is the second frequent disaster. A total of 32,966 fires were happened in 2002, and injured 2,235 people and damaged 12 million dollars. So, we developed several components related to fire in order to decrease these victims and the amount of damage and have applied those components to Daegu Fire Agency. In this paper, we describe the developing system. It consists of 5 major components: mobile fire facility management component, web service component, fire management component, fire server, and fire application. They were developed in object-oriented computing environment, ATL/COM and Visual C++. So, they have some advantages such as high reusability, full interoperability, and easy understanding.

  • PDF

The Inspection of Press Forming Product of backward lamp parts at automobile through Application of Reverse Engineering System (역설계 시스템 적용을 통한 자동차 후방 램프부의 프레스 성형물 검사)

  • Kim S.Y.;Kim T.H.;Kim M.J.;Lee S.S.;Jeon E.C.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 한국정밀공학회 2005년도 추계학술대회 논문집
    • /
    • pp.419-422
    • /
    • 2005
  • This study is an inspection of press forming product and mould using reverse engineering system. The inspection process on production field involves a lot of errors because of the hand-work so we focussed on improving the measured precision through performing the effective inspection using 3D non-contact scanner. By so doing that, we improved the precision of press forming product by analyzing the cause fellowing the inspection result. Through the inspection, we applied it to the reverse engineering and we could improve the inspection process.

  • PDF

The Inspection of Press Forming Product of forward conner parts at automobile through Application of Reverse Engineering System (역설계 시스템 적용을 통한 자동차 전방 모서리부의 프레스 성형물 검사)

  • Han M.S.;Park J.D.;Kim M.J.;Lee S.S.;Jeon E.C.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 한국정밀공학회 2005년도 추계학술대회 논문집
    • /
    • pp.962-965
    • /
    • 2005
  • This study is an inspection of press forming product and mould using reverse engineering system. The inspection process on production field involves a lot of errors because of the hand-work so we focussed on improving the measured precision through performing the effective inspection using 3D non-contact scanner. By so doing that, we improved the precision of press forming product by analyzing the cause following the inspection result. Through the inspection, we applied it to the reverse engineering and we could improve the inspection process.

  • PDF

Study on Optimal Phase Arrangement Considering the Characteristics of Inductive Interference from Overhead Transmission Lines (가공송전선 유도장해 특성을 고려한 최적 상배열 연구)

  • Kang, Kyung-Doo;Kim, Jin-Gyu
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • 제68권1호
    • /
    • pp.13-18
    • /
    • 2019
  • The domestic overhead transmission lines use a vertical configuration and reverse phase arrangement, but when there is a limitation in steel tower height because the transmission lines pass a height limit zone or special zone, an application of triangular arrangement is necessary, and a study on the optimal phase arrangement to minimize inductive interference for this is necessary. If conductor arrangement are changed, the action of electrostatic induction and electromagnetic induction becomes different from before changes, so the changed conductor arrangement should be reviewed in terms of inductive interference. So this paper presents an optimal phase arrangement to reduce inductive interference by calculating electrostatic induction and electromagnetic induction according to conductor arrangement.

Selective Oxidation of Hydrogen Sulfide Containing Ammonia and Water Using Fe2O3/SiO2 Catalyst (Fe2O3/SiO2 촉매 상에서 물과 암모니아가 함께 존재하는 황화수소의 선택적 산화 반응)

  • Kim, Moon-Il;Lee, Gu-Hwa;Chun, Sung-Woo;Park, Dae-Won
    • Korean Chemical Engineering Research
    • /
    • 제50권3호
    • /
    • pp.398-402
    • /
    • 2012
  • The catalytic performance of some metal oxides in the vapor phase selective oxidation of $H_2S$ in the stream containing ammonia and water was investigated. Among the catalysts tested $Fe_2O_3/SiO_2$ was the most promising catalyst for practical application. It showed higher than 90% $H_2S$ conversion and very small amount of $SO_2$ emission over a temperature range of $240{\sim}280^{\circ}C$. The effects of reaction temperature, $O_2/H_2S$ ratio, amount of ammonia and water vapor on the catalytic activity of $Fe_2O_3/SiO_2$ were discussed to better understand the reaction mechanism. The $H_2S$ conversion showed a maximum at $260^{\circ}C$ and it decreased with increasing temperature over $280^{\circ}C$. With an increase of $O_2/H_2S$ ratio from 0.5 to 4, the conversion was slightly increased, but the selectivity to elemental sulfur was remarkably decreased. The increase of ammonia amount favored the conversion and the selectivity to elemental sulfur with a decrease in $SO_2$ production. The presence of water vapor decreased both the activity and the selectivity to sulfur, but increased the ATS selectivity.