• Title/Summary/Keyword: Application Procedure

Search Result 2,388, Processing Time 0.031 seconds

Evaluation of at-home bleaching protocol with application on different surfaces: bleaching efficacy and hydrogen peroxide permeability

  • Heloisa Forville;Michael Willian Favoreto;Michel Wendlinger;Roberta Micheten Dias;Christiane Philippini Ferreira Borges;Alessandra Reis;Alessandro D. Loguercio
    • Restorative Dentistry and Endodontics
    • /
    • v.48 no.4
    • /
    • pp.33.1-33.12
    • /
    • 2023
  • Objectives: This study aimed to evaluate the bleaching efficacy and hydrogen peroxide permeability in the pulp chamber by the at-home bleaching gel in protocols applied on different dental surfaces. Materials and Methods: Forty premolars were randomly into 4 groups: control group no bleaching, only application on the buccal surface (OB), only application on the lingual surface (OL) and application in buccal and lingual surfaces, simultaneously (BL). At-home bleaching gel (White Class 7.5%) was used for the procedure. The bleaching efficacy was evaluated with a digital spectrophotometer (color change in CIELAB [ΔEab] and CIEDE 2000 [ΔE00] systems and Whitening Index for Dentistry [ΔWID]). The hydrogen peroxide permeability in the pulp chamber (㎍/mL) was assessed using UV-Vis spectrophotometry and data were analyzed for a 1-way analysis of variance and Tukey's test (α = 0.05). Results: All groups submitted to bleaching procedure showed bleaching efficacy when measured with ΔEab and ΔE00 (p > 0.05). Therefore, when analyzed by ΔWID, a higher bleaching efficacy were observed for the application on the groups OB and BL (p = 0.00003). Similar hydrogen peroxide permeability was found in the pulp chambers of the teeth undergoing different protocols (p > 0.05). Conclusions: The application of bleaching gel exclusively on the OB is sufficient to achieve bleaching efficacy, when compared to BL. Although the OL protocol demonstrated lower bleaching efficacy based on the ΔWID values, it may still be of interest and relevant in certain clinical scenarios based on individual needs, requiring clinical trials to better understand its specificities.

Analyzing a Class of Investment Decisions in New Ventures : A CBR Approach (벤쳐 투자를 위한 의사결정 클래스 분석 : 사례기반추론 접근방법)

  • Lee, Jae-Kwang;Kim, Jae-Kyeong
    • Proceedings of the Korea Inteligent Information System Society Conference
    • /
    • 1999.10a
    • /
    • pp.355-361
    • /
    • 1999
  • An application of case-based reasoning is proposed to build an influence diagram for identifying successful new ventures. The decision to invest in new ventures in characterized by incomplete information and uncertainty, where some measures of firm performance are quantitative, while some others are substituted by qualitative indicators. Influence diagrams are used as a model for representing investment decision problems based on incomplete and uncertain information from a variety of sources. The building of influence diagrams needs much time and efforts and the resulting model such as a decision model is applicable to only one specific problem. However, some prior knowledge from the experience to build decision model can be utilized to resolve other similar decision problems. The basic idea of case-based reasoning is that humans reuse the problem solving experience to solve a new decision. In this paper, we suggest a case-based reasoning approach to build an influence diagram for the class of investment decision problems. This is composed of a retrieval procedure and an adaptation procedure. The retrieval procedure use two suggested measures, the fitting ratio and the garbage ratio. An adaptation procedure is based on a decision-analytic knowledge and decision participants knowledge. Each step of procedure is explained step by step, and it is applied to the investment decision problem in new ventures.

  • PDF

The Effect of Look-Ahead Routing Procedure for Flow Control in an FMS (FMS 흐름 통제를 위한 Look-Ahead Routing Procedure의 적용효과)

  • Suh, Jeong-Dae;Jang, Jae-Jin
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.25 no.1
    • /
    • pp.35-46
    • /
    • 1999
  • The introduction of general purpose machining centers and the information system based on computer network has added a new control problem to the classical job shop control problems: a routing problem. A routing problem is to determine the machine on which a part will be processed. The modern manufacturing systems are given much system status information including the arrival time of the future parts via the computer network for automation. This paper presents and tests the performance of a routing procedure, LARP(Look-Ahead Routing Procedure) which uses look-ahead information on the future arrival of parts in the system. The manufacturing system considered in this paper has multi-stations which consists of general purpose machines and processes parts of different types. The application of LARP under many operating conditions shows that the reduction of part flow time and tardiness from the cases without using this information is up to 8% for flow time and 21% for tardiness. The procedure introduced here can be used for many highly automated systems such as an FMS and a semi-conductor fabrication system for routing where the arrivals of parts in the near future are known.

  • PDF

Limitations and improvement of the in situ measurements of ground thermal conductivity in Korea (국내 지중열전도도 측정 방법의 한계 및 개선 방향)

  • Shim, Byoung Ohan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.195.2-195.2
    • /
    • 2011
  • The borehole heat exchanger of Geothermal Heat Pump (GHP) system should be sustainable and cost effective for long term operation. To guaranty the performance of the system thermal Response Tests (TRTs) with simple recommended procedures have been applied in many countries. Korea government developed a standard TRT procedure in order to control the quality on GHP projects. In the TRT procedure interpretation method has a rule that data set has to be interpreted by the line source model(LSM). The LSM employes some assumptions that surrounding medium is homogeneous and the line source is infinite and constant heat flux, however real ground condition is unisotropic and heterogeneous, and showing regional or local ground water flows in many cases. We need to develope improved evaluation models to estimate accurate ground thermal conductivity with respect to geological and influence of ground water because current TRT standard test procedure has limitations to be applied for every locations and system. This study surveyed the uncertainty of the thermal parameters from the interpretation method considering different evaluation period. The interpretation of 208 TRT data sets represents limitations of LSM application that some obtained ground thermal conductivities are statistically unstable and convergence time of ground thermal conductivity over test period shows trends responding the length of test period. This evaluation study will be helpful to provide some effective procedure for the thermal parameter estimation and to complement current TRT standard procedure.

  • PDF

A unified design procedure for preloaded rectangular RC columns strengthened with post-compressed plates

  • Wang, L.;Su, R.K.L.
    • Advances in concrete construction
    • /
    • v.1 no.2
    • /
    • pp.163-185
    • /
    • 2013
  • The use of post-compressed plates (PCP) to strengthen preloaded reinforced concrete (RC) columns is an innovative approach for alleviating the effects of stress-lagging between the original column and the additional steel plates. Experimental and theoretical studies on PCP-strengthened RC columns have been presented in our companion papers. The results have demonstrated the effectiveness of this technique for improving the strength, deformability and ductility of preloaded RC columns when subjected to axial or eccentric compression loading. An original and comprehensive design procedure is presented in this paper to aid engineers in designing this new type of PCP-strengthened RC column and to ensure proper strengthening details for desirable performance. The proposed design procedure consists of five parts: (1) the estimation of the ultimate load capacity of the strengthened column, (2) the design of the initial pre-camber displacement of the steel plate, (3) the design of the vertical spacing of the bolts, (4) the design of the bearing ends of the steel plates, and (5) the calculation of the tightening force of the bolts. A worked example of the design of a PCP-strengthened RC column is shown to demonstrate the application of the proposed design procedure.

A displacement-based seismic design procedure for buildings with fluid viscous dampers

  • Banuelos-Garcia, Francisco H.;Ayala, Gustavo;Lopez, Saul
    • Earthquakes and Structures
    • /
    • v.18 no.5
    • /
    • pp.609-623
    • /
    • 2020
  • This paper presents a displacement-based seismic design procedure for new structures with fluid viscous dampers and/or for existing structures, where these devices are required as a retrofit measure and damage control. To consider the non-proportional damping produced by these devices in a conventional modal spectral analysis, the effect of the fluid viscous dampers is approximated as the sum of a proportional damping matrix and a complementary matrix which is representative of non-proportional damping matrix. To illustrate the application of this procedure and evaluate the performance of structures designed with the procedure proposed, five regular plane frames: 8, 12, 17, 20 and 25-storey, and an 8-storey building are designed. The seismic demands used for design and validation were the records obtained at the SCT site during the 1985 Michoacan earthquake, and that of the 2017 Morelos - Puebla earthquake obtained at the Culhuacan site, both stations located on soft soil sites. To validate the procedure proposed, the performances and damage distributions used as design targets were compared with the corresponding results from the nonlinear step-by-step analyses of the designed structures subjected to the same seismic demands.

GDSS for the Mobile Internet

  • Cho, Yoon-Ho;Choi, Sang-Hyun;Kim, Jae-Kyeong
    • Proceedings of the Korea Inteligent Information System Society Conference
    • /
    • 2005.05a
    • /
    • pp.283-291
    • /
    • 2005
  • The development of mobile applications is fast in recent years. However, nearly all applications are for messaging, financial, locating services based on simple interactions with mobile users because of the limited screen size, narrow network bandwidth, and low computing power. Processing an algorithm for supporting a group decision process on mobile devices becomes impossible. In this paper, we introduce the mobile-oriented simple interactive procedure for support a group decision making process. The interactive procedure is developed for multiple objective linear programming problems to help the group select a compromising solution in the mobile Internet environment. Our procedure lessens the burden of group decision makers, which is one of necessary conditions of the mobile environment. Only the partial weak order preferences of variables and objectives from group decision makers are enough for searching the best compromising solution. The methodology is designed to avoid any assumption about the shape or existence of the decision makers's utility function. For the purpose of the experimental study of the procedure, we developed a group decision support system in the mobile Internet environment, MOBIGSS and applied to an allocation problem of investor assets.

  • PDF

The Current State of and Barriers to Quality Measurement, and Quality Managers' Reported Evaluation on Quality Indicators in Korea (국내 질 향상부서 중심의 질 지표 측정 현황, 장애요인과 평가)

  • Hwang Jee-In
    • Health Policy and Management
    • /
    • v.15 no.4
    • /
    • pp.26-45
    • /
    • 2005
  • The purposes of this study were to Identify the .level of measurement on quality Indicators and evaluate the existing indicators in order to determine the priority of quality indicators' application in Korean general hospitals. A survey was conducted using a questionnaire. The subjects were quality managers working at general hospital having over 300 beds. The criteria were relevance, reliability, precision, impact, application, and preference to evaluate quality indicators. According to these six criteria, each indicator was evaluated on a five point scale(5: excellent, 1: poor). The response rate was $40.4\%$. The hospitals have monitored the average of 3.8 indicators(median 4). The indicators such as return to operating room, unplanned readmission, cancellation of booked operations, death, hospital infection, cesarean section rate, volume per disease or procedure, readmission, re-operation, blood transfusion, and post-procedural complications were frequently measured. The top ten quality indicators in the evaluation by its relevance, validity, reliability, impact, preference and application were decubitus ulcer, clean wound infection, fall, unplanned return to operation room, transfusion reactions, foreign body left In during procedure, unplanned readmission, wound infection after contaminated surgery, postoperative hemorrhage/hematoma, and cesarean section rate in order. The high priority quality indicators frequently measured could be used as primary national indicators. Standardized guidelines about monitoring indicators and the utilization will preliminarily be needed to compare and reuse the data for various purposes and improve the quality of care continuously.

Effects of Kinesio Taping Therapy in Patients with Stenosing Tenosynovitis (협착성 건초염에 대한 키네시오 테이핑치료의 효과)

  • Lee, Moon-Hwan;Ma, Sang-Yeol;Lee, Hyeon-Hee;Kim, Seong-Hak;Park, Rae-Joon
    • The Journal of Korean Physical Therapy
    • /
    • v.19 no.1
    • /
    • pp.1-9
    • /
    • 2007
  • Purpose: Stenosing tenosynovitis is a stenosing condition of the sheath of the abductor pollicis longus and extensor pollicis brevis tendons at the radial styloid process. The purpose of this study was to investigate the effects of kinesio taping on the pain and grip power in patients with de Quervain's disease. Method: 20 female with de Quervain's disease was recruited. This procedure was performed with or without taping procedure. Pain levels were assessed using a visual analogue scale, and spherical and pinch grip powers were assessed using a dynamometer. Results: 1. Resting pain, Finkelstein test pain, and Tenderness using VAS scale was showed significantly reduced after taping application(p<0.01). 2. Spherical grip power using dynamometer was showed significantly increased after taping application(p<0.01). 3. Pinch grip power using dynamometer was showed significantly increased after taping application(p<0.01). Conclusion: So we thought that kinesio taping therapy had effects on the pain release and grip power increasing to the small or local muscle groups and joints.

  • PDF

A consistent FEM-Vlasov model for hyperbolic cooling towers on layered soil under unsymmetrical wind load

  • Karakas, Ali I.;Ozgan, Korhan;Daloglu, Ayse T.
    • Wind and Structures
    • /
    • v.22 no.6
    • /
    • pp.617-633
    • /
    • 2016
  • In this paper, the analysis of hyperbolic cooling tower on elastic subsoil exposed to unsymmetrical wind loading is presented. Modified Vlasov foundation model is used to determine the soil parameters as a function of vertical deformation profile within subsoil. The iterative parameter updating procedure involves the use of Open Application Programming Interface (OAPI) feature of SAP2000 to provide two way data flow during execution. A computing tool coded in MATLAB employing OAPI is used to perform the analysis of hyperbolic cooling tower with supporting columns over a hollow annular raft founded on elastic subsoil. The analysis of such complex soil-structure system is investigated under self-weight and unsymmetrical wind load. The response of the cooling tower on elastic subsoil is compared with that of a tower that its supporting raft foundation is treated as fixed at the base. The results show that the effect of subsoil on the behavior of cooling tower is considerable at the top and bottom of the wall as well as supporting columns and raft foundation. The application of a full-size cooling tower has demonstrated that the procedure is simple, fast and can easily be implemented in practice.