• Title/Summary/Keyword: Application

Search Result 82,557, Processing Time 0.104 seconds

Development of a Simultaneous Analysis Method for DDT (DDD & DDE) in Ginseng (인삼 중 DDT(DDD 및 DDE) 분석법의 개발)

  • Kim, Sung-Dan;Cho, Tae-Hee;Han, Eun-Jung;Park, Seoung-Gyu;Han, Chang-Ho;Jo, Han-Bin;Choi, Byung-Hyun
    • Korean Journal of Food Science and Technology
    • /
    • v.40 no.2
    • /
    • pp.123-128
    • /
    • 2008
  • The MRLs (maximum residue limits) of DDT (DDD and DDE) in fresh ginseng, dried ginseng, and steamed red ginseng are set as low as 0.01 mg/kg, 0.05 mg/kg, and 0.05 mg/kg, respectively. Therefore, this study was undertaken to develop a simple and highly sensitive analysis method, as well as to reduce interfering ginseng matrix peaks, for the determination of DDT isomers (o,p'-DDE, p,p'-DDE, o,p'-DDD, p,p'-DDD, o,p'-DDT, and p,p'-DDT) in fresh ginseng, dried ginseng, and steamed red ginseng at the 0.01 mg/kg level. The method used acetonitrile extraction according to simultaneous analysis, followed by normal-phase Florisil solid-phase extraction column clean-up. The purification method entailed the following steps: (1) dissolve the concentrated sample extract in 7 mL hexane; (2) add 3 mL of $H_2SO_4$; (3) vigorously shake on avortex mixer; (4) cetrifuge at 2000 rpm for 5 min; (5) transfer 3.5 mL of the supernatant to the Florisil-SPE (500 mg/6 mL);and (6) elute the SPE column with 1.5 mL of hexane and 10 mL of ether/hexane (6:94). The determination of DDT isomers was carried out by a gas chromatography-electron capture detector (GC-${\mu}$ECD). The hexane and ether/hexane (6:94) eluate significantly removed chromatographic interferences, and the addition of 30% $H_2SO_4$ to the acetonitrile extract effectively reduced many interfering ginseng matrix peaks, to allow for the determination of the DDT isomers at the 0.01 mg/kg level. The recoveries of the 6 fortified (most at 0.01 mg/kg) DDT isomers from fresh ginseng, dried ginseng, and steamed red ginseng ranged from 87.9 to 99.6%. The MDLs (method detection limits) ranged from 0.003 to 0.009 mg/kg. Finally, the application of this method for the determination of DDT isomers is sensitive, rapid, simple, and inexpensive.

Detection of irradiated food using photostimulated luminescence and thermoluminescence (물리적 방법(PSL, TL)을 이용한 선종별 조사처리 식품의 검지 특성)

  • Jung, Yoo-Kyung;Lee, Ji-Yeon;Kang, Tae-Sun;Jo, Cheon-Ho;Lee, Jae-Hwang;Choi, Jang-Duck;Kwon, Ki-Sung
    • Korean Journal of Food Science and Technology
    • /
    • v.48 no.5
    • /
    • pp.399-404
    • /
    • 2016
  • The applicability of photostimulated-luminescence (PSL) and thermoluminescence (TL) for the detection of 12 food materials (potato, onion, garlic, dried pumpkin, black mushroom, black soybean, Cheongkukjang powder, sea mustard, pepper powder, Ramyun soup, corn tea, and green tea powder) irradiated with an electron beam, gamma ray, and X ray at a range of 0.15 to 10 kGy was investigated. For PSL, negative results (less than 700 photon counts (PCs)) were observed from non-irradiated foods while the irradiated foods showed intermediate (879 to 2,414 PCs) and/or positive (19,951 to 65,919,035 PCs) values. In all irradiated samples, the maximum peak of the TL glow curve was observed between 150 and $250^{\circ}C$. Our findings demonstrate the successful application of PSL and TL to determine whether food items were irradiated or not. However, there were no significant differences among the radiation sources.

Development of Task Guidelines for Hospice Team Members (호스피스 팀 구성원의 직무지침 개발)

  • Ro, You-Ja;Han, Sung-Suk;Yoo, Yang-Sook;Yong, Jin-Sun
    • Journal of Hospice and Palliative Care
    • /
    • v.4 no.1
    • /
    • pp.26-40
    • /
    • 2001
  • Purpose : The purpose of this study was to develop task guidelines for hospice team members. The task range of all personnel who work for hospice institutions was identified, and a tool describing roles and tasks of the hospice team members was developed based on review of related literature, both domestic and international. Methods : The content validity of the tool was assured by an expert panel through two phases of discussion. The first phase of the study included a survey conducted from December 1999 to January 2000 for a total of 126 hospice experts and practitioners affiliated with domestic hospice institutions. The second phase of the study included 35 subjects. The data were collected using a survey when the investigators visited each hospice institution. The data were analyzed using descriptive statistics. Results : 1) In the first phase of the study, all items scored over 80 points in CVI were selected as the roles and tasks of hospice coordinator, nurse, pastor, social worker, pharmacist, nutritionist, therapist, volunteer, and nurse aide. However, two items were excluded because they scored below 80 points: an item describing eligibility of a physician, a person who has a license for managing anesthetic agents was scored as 78.6 points, and an item describing the eligibility of the team leader of volunteers, a person educated at the graduate level was scored as 74.7 points. 2) In the second phase of the study, all items scored over 80 points in CVI were selected as the roles and tasks of hospice nurse, pastor, social worker, pharmacist, nutritionist, therapist, volunteer, and nurse aide. Of the roles of the hospice coordinator, however, the item scored as 77.9 points, assess and plan a patients physical, social, emotional, and spiritual status, and, of the roles of the team leaders of volunteers, the item scored as 78.6, attend a team meeting once a week and participate in building an standard nursing plan for patients were included in the tool since they scored over 80 points in the first phase of the study. Conclusion : The developed task guideline should be further modified and revised based on the findings of a preliminary application in the actual field. There is also a need of continuous research for developing more culturally-appropriate task guidelines for hospice team members.

  • PDF

Microbiological Hazard Analysis for HACCP System Application to Non Heat-Frozen Carrot Juice (비가열냉동 당근주스의 HACCP 시스템 적용을 위한 미생물학적 위해 분석)

  • Lee, Ung-Soo;Kwon, Sang-Chul
    • Journal of Food Hygiene and Safety
    • /
    • v.29 no.2
    • /
    • pp.79-84
    • /
    • 2014
  • This study has been performed for about 270 days at analyzing biologically hazardous factors in order to develop HACCP system for the non heat-frozen carrot juice. A process chart was prepared by manufacturing process of raw agricultural products of non heat-frozen carrot juice, which was contained water and packing material, storage, washing, cutting, extraction of the juice, internal packing, metal detection, external packing, storage and consignment (delivery). As a result of measuring Coliform group, Staphylococcus aureus, Salmonella spp., Bacillus cereus, Listeria Monocytogenes, Enterohemorrhagic E. coli before and after washing raw carrot, Standard plate count was $4.7{\times}10^4CFU/g$ before washing but it was $1.2{\times}10^2CFU/g$ detected after washing. As a result of testing airborne bacteria (Standard plate count, Coliform group, Yeast and Fungal) depending on each workplace, number of microorganism of in packaging room, shower room and juice extraction room was detected to be 10 CFU/Plate, 60 CFU/Plate, 20 CFU/Plate, respectively. As a result of testing palm condition of workers, as number of Standard plate count, Coliform group and Staphylococcus aureus was represented to be high as $6{\times}10^4CFU/cm^2$, $0CFU/cm^2$ and $0CFU/cm^2$, respectively, an education and training for individual sanitation control was considered to be required. As a result of inspecting surface pollution level of manufacturing facility and devices, Coliform group was not detected in all the specimen but Standard plate count was most dominantly detected in scouring kier, scouring kier tray, cooling tank, grinding extractor, storage tank and packaging machine-nozzle as $8.00{\times}10CFU/cm^2$, $3.0{\times}10CFU/cm^2$, $4.3{\times}10^2CFU/cm^2$, $7.5{\times}10^2CFU/cm^2$, $6.0{\times}10CFU/cm^2$, $8.5{\times}10^2CFU/cm^2$ respectively. As a result of analyzing above hazardous factors, processing process of ultraviolet ray sterilizing where pathogenic bacteria may be prevented, reduced or removed is required to be controlled by CCP-B (Biological) and critical level (critical control point) was set at flow speed is 4L/min. Therefore, it is considered that thorough HACCP control plan including control criteria (point) of seasoning fluid processing process, countermeasures in case of its deviation, its verification method, education/training and record control would be required.

Effect of Chlorine Dioxide and Sodium Hypochlorite Treatment on the Reduction of Foodborne Pathogen in Korean Chive (영양부추에서 이산화염소와 차아염소산나트륨 처리의 식중독세균 저감화 효과)

  • Yun, Bohyun;Lee, Hyo-Sup;An, Hyun Mi;Kim, Won-Il;Kim, Hwang-Yong;Han, Sanghyun;Kim, Hyun-Ju;Ryu, Jae-Gee;Kim, Se-Ri
    • Journal of Food Hygiene and Safety
    • /
    • v.32 no.2
    • /
    • pp.154-162
    • /
    • 2017
  • The purpose of this study was to investigate the microbial reduction effect of chlorine dioxide and sodium hypochlorite in Korean chive. Korean chive inoculated with foodborne pathogens at the level of approximately 7~8 log CFU/g was treated with various concentration of chlorine dioxide (3, 4, 10, 25 and 100 ppm and sodium hypochlorite (100, 150 and 200 ppm) for 5, 10, 30 and 60 minutes. The treatment of 150 ppm sodium hypochlorite and 50 ppm chlorine dioxide for 30 min reduced the number of total bacteria in Korean chive up to 2.0 log CFU/g. Reduction of microbial levels was observed for all concentrations of sanitizers but their effectiveness did not correspond to their concentration. Due to the quality degradation, 50 ppm chlorine dioxide was not appropriate for Korean chive. Most effective reduction of microbial levels was observed when Korean chive were treated with 9 times more sanitizer in volume. For field application, the treatment of 150 ppm sodium hypochlorite showed 2.7 and 4.0 log CFU/g reductions for numbers of total bacteria and coliforms, respectively. Therefore, washing with sodium hypochlorite of a ratio of 1:9 (Korean chive : 150 ppm sodium hypochlorite (w/v)) for 30 minutes can reduce the number of foodborne pathogen in Korean chive.

Ultasonic Reflection Characteristics of the Underwater Corner Reflector (수중코오너리프렉터의 초음파반사특성에 관한 연구)

  • Lee, Dae-Jae;Sin, Hyeong-Il
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.19 no.1
    • /
    • pp.25-32
    • /
    • 1983
  • The corner reflector is used to increase the echoing area of radar targets in the air, and it can also be applied to increase the echoing area of the sonar targets under water. As the basic research for this application, the authors investigated the ultrasonic reflection characteristics under water for the corner reflector which was made of aluminum plate. The experiments were made by pulse measuring method with the magnetostrictive ferrite transducers of 28, 50 and 75KHz in the experimental water tank. The results obtained are as follows; 1. The target strength of corner reflectors were increased in proportion to the diameter and were greater at higher frequency of 75KHz than at lower frequency of 28KHz. 2. In the case of 5 corner reflectors of 150mm in diameter which have corner angles of 15$^{\circ}$, 30$^{\circ}$, 45$^{\circ}$, 60$^{\circ}$ and 90$^{\circ}$the measured values of the maximum target strength at 75KHz were-25.0 dB, -17.2dB, -15.1dB, -13.4dB and 11.0dB, and then the number of main lobes showing the maximum target strength in the backscattering patterns were 24, 12, 8, 6 and 4, respectively. 3. When 7 corner reflector of 80mm in diameter and 90$^{\circ}$ in the corner angle was located on the minor axis of the horizontal section with directional angles of 0$^{\circ}$, 2.5$^{\circ}$, 5.0$^{\circ}$, 7.5$^{\circ}$, 10$^{\circ}$ and 12.5$^{\circ}$ against the sound beam axis, the measured values of the target strength on each position at 75KHz were -21.2dB, -21.9dB, -26.0dB, -30.5dB and -36.8dB, respectively.

  • PDF

Evaluation of hazardous factors for the application of HACCP on production and transportation flow in home-delivered meals for the elderly (노인을 위한 가정배달급식의 생산 및 배송단계에 HACCP 적용을 위한 위해요인 분석 1)

  • 김혜영;류시현
    • Korean journal of food and cookery science
    • /
    • v.19 no.2
    • /
    • pp.195-209
    • /
    • 2003
  • The purpose of this study was to identify the hazard analysis critical control point on food production and transportation flow, applied to home-delivered meals for the elderly. To carry out this study, 1) pan-fried oak mushroom and meat, soy sauce glazed hair tail, and roasted dodok were selected as high nutrient and preferred foods for the elderly and 2) time, temperature, and microbiological quality(standard plate count, coliform, Salmonella spp, Vibrio parahaemolyticus, Staphylococcus spp., Escherichia coli O157:H7, and Listeria monocytogenes) were measured at various phases of the home-delivered meal production and its transportation flows. The results of this experiments are as follows: The temperature measured at cooling phases during the home-delivered meal production flows was 19.2 ∼ 20.0$^{\circ}C$ for the pan- fried oak mushroom and meat and the roasted dodok and was 24.0 ∼ 25.2$^{\circ}C$ for the soy sauce glazed hair tail. These temperature were in the potentially dangerous zone. Microbiological analysis showed that S. spp. was higher in the raw ingredients, including oak mushroom, hair tail, radish, and dodok, than the standard limit. SPC was lower than the standard limit from cooking to transportation phase, but SPC increased significantly during the cooling and packaging phase. The level of coliform detected was far lower than the standard limit and was not detected at all during the transportation phase. Few S. spp. was detected in the pan-fried oak mushroom and meat, but was found in above standards limit during the wrap packaging phase in the soy sauce glazed hair tail and roasted dodok. The level decreased rapidly during the holding and transportation phase. Sal. spp., V. parahaemolyticus, S. spp., E. coli O157:H7, and L. monocytogenes were not detected. For the pan-fried oak mushroom and meat, the critical control points were during the purchasing and receiving of raw ingredients, cooling, and packaging phases. For the soy sauce glazed hair tail and roasted dodok, the critical control points were during the purchasing and receiving of raw ingredients, preparation, cooling, and packaging phases.

Monitoring the Rate of Frozen Denaturation of Bovine Myosin by Competitive Indirect ELISA Method (Competitive Indirect ELISA를 이용한 Bovine Myosin의 동결 변성도 측정)

  • Kim, Seong-Bae;Lee, Ju-Woon;Park, Jong-Heum;Do, Hyung-Ki;Hyun, Chang-Kee;Shin, Heuyn-Kil
    • Korean Journal of Food Science and Technology
    • /
    • v.30 no.4
    • /
    • pp.862-870
    • /
    • 1998
  • This study shows the application of Ci-ELISA method for monitoring the denaturation of myosin by the frozen treatment in order to differentiate thawed beef from chilled. Hanwoo M.Semitendinosus (n=25) was treated under the two different frozen process as follows; simple frozen treatment (Exp-1) at 4 different temperatures, -10, -20, -50 and $-80^{\circ}C$, respectively, and repeated thawing-refreezing treatment (Exp-2) stored at 4 different temperatures, -10, -20, -50 and $-80^{\circ}C$, respectively. Antibodies (Abs) were produced from rabbits immunized with myosin whole molecule (MWM) isolated from beef round, heavy meromyosin S-1 (S-1) and light meromyosin (LMM) prepared by digestion of MWM. Each immunoglobulin G (IgG) was separated from antiserum. At 6 month storage, IA of anti-MWM IgG for myosin was decreased to 32.67, 32. 23, 51.52 and 34.27% in Exp-1 and to 14.82, 15.61, 25.3 and 23.7% in Exp-2 at -10, -20, -50 and $-80^{\circ}C$, respectively (P<0.05). In Exp-1, the reactivities of anti-LMM IgG were decreased to 25.12, 21.42, 49.05 and 28.96%, and those of Exp-2 were to 11.88, 9.56, 20.63 and 12.64% at -10, -20, -50 and $-80^{\circ}C$, respectively, at 6 times thawing (P<0.05). Conclusively, myosin was denaturated by freezing treatment and LMM or myosin rod part might have suffered from more extreme demage than HMM S-1, and samples at $-50^{\circ}C$ were slightly injured less than others by freezing treatment.

  • PDF

A Study on the Application of Bushings Fire Prevent Structure to Prevent Fire Spread of Transformer (변압기의 화재확산 방지를 위한 부싱 방화구조체 적용에 관한 연구)

  • Kim, Do-Hyun;Cho, Nam-Wook;Yoon, Choung-Ho;Park, Pil-Yong;Park, Keun-Sung
    • Fire Science and Engineering
    • /
    • v.31 no.5
    • /
    • pp.53-62
    • /
    • 2017
  • Electric power which is the energy source of economy and industries requires long distance transportation due to regional difference between its production and consumption, and it is supplied through the multi-loop transmission and distribution system. Prior to its actual use, electric power flows through several transformations by voltage transformers in substations depending on the characteristics of each usage, and a transformer has the structure consisting of the main body, winding wire, insulating oil and bushings. A transformer fire that breaks out in substations entails the primary damage that interrupts the power supply to houses and commercial facilities and causes various safety accidents as well as the secondary economic losses. It is considered that causes of such fire include the leak of insulating oil resulting from the destruction of bottom part of bushings, and the chain reaction of fire due to insulating oil that reaches its ignition point within 1 second. The smoke detector and automatic fire extinguishing system are established in order to minimize fire damage, but a difficulty in securing golden time for extinguishing fire due to delay in the operation of detector and release of gas from the extinguishing system has become a problem. Accordingly, this study was carried out according to needs of active mechanism to prevent the spread of fire and block the leak of insulating oil, in accordance with the importance of securing golden time in extinguishing a fire in its early stage. A bushings fireproof structure was developed by applying the high temperature shape retention materials, which are expanded by flame, and mechanical flame cutoff devices. The bushings fireproof structure was installed on the transformer model produced by applying the actual standards of bushings and flange, and the full scale fire test was carried out. It was confirmed that the bushings fireproof structure operated at accurate position and height within 3 seconds from the flame initiation. It is considered that it could block the spread of flame effectively in the event of actual transformer fire.

A Study on the Cause Analysis and Countermeasures of the Traditional Market for Fires in the TRIZ Method (TRIZ 기법에 의한 재래시장 화재의 원인분석과 대책에 관한 연구)

  • Seo, Yong-Goo;Min, Se-Hong
    • Fire Science and Engineering
    • /
    • v.31 no.4
    • /
    • pp.95-102
    • /
    • 2017
  • The fires in the traditional markets often occur recently with the most of them expanded into great fires so that the damage is very serious. The status of traditional markets handling the distribution for ordinary people is greatly shrunk with the aggressive marketing of the local large companies and the foreign large distribution companies after the overall opening of the local distribution market. Most of the traditional markets have the history and tradition from decades to centuries and have grown steadily with the joys and sorrows of ordinary people and the development of the local economy. The fire developing to the large fire has the characteristics of the problem that the fire possibility is high since all products can be flammable due to the deterioration of facilities, the arbitrary modification of equipment, and the crowding of the goods for sale. Furthermore, most of the stores are petty with their small sizes so that the passage is narrow affecting the passage of pedestrians. Accordingly, the traditional markets are vulnerable to fire due to the initial unplanned structural problem so that the large scale fire damage occurs. The study is concerned with systematically classifying and analyzing the result by applying the TRIZ tool to the fire risk factors to extract the fundamental problem with the fire of the traditional market and make the active response. The study was done for preventing the fire on the basis of it and the expansion to the large fire in case of fire to prepare the specific measure to minimize the fire damage. On the basis of the fire expansion risk factor of the derived traditional market, the study presented the passive measures such as the improvement of the fire resisting capacity, the fire safety island, etc. and the active and institutional measures such as the obligation of the fire breaking news facilities, the application of the extra-high pressure pump system, the divided use of the electric line, etc.