A Study on the Development of Greenhouse Temperature Control System by Using Micro-computer (Micro-computer를 이용(利用)한 Greenhouse의 온도제어(溫度制御) System 개발(開發)에 관한 연구(硏究))

  • Suh, W.M.;Min, Y.B.;Yoon, Y.C.
    • Journal of Biosystems Engineering
    • /
    • v.15 no.2
    • /
    • pp.134-142
    • /
    • 1990
  • This study was carried out for the development of greenhouse temperature control system by modifying an APPLE-II microcomputer attached with several interface systems. The interface systems are composed of 12 bit A/D converter, output port, multiplexer, time clock, etc. Under the operation of developed system, the greenhouse temperature was to be manipulated within the setting temperatures assumed to be appropriate for certain plant growth. The temperature control equimpents installed in the greenhouse are one-speed propeller type fan and two-phase electric heater, which are selectively started or stopped according to the control logic programmed in the control system. The results are summarized as follows : 1. The difference between two temperatures measured by the developed system and the self-recording thermometer calibrated with standard thermometer was less than $1^{\circ}C$. 2. When the temperature were measurd by 12 bit A/D converter and both electric heater and ventilation fan were controlled by developed ON/OFF logic, greenhouse temperature showed narrow fluctuation bands of less than $1^{\circ}C$ near the setting temperatures. 3. The temperature acquisition and control system developed in this study is expected to be applicable to environment control system such as greenhouse only by modifying the logic based on long term experimental data. 4. In order to reduce the measurement error and to increase the system control efficiency, it is recommended that continuous study should be carried out in the aspect of eliminating various systematic noises and improving the environmental control logic.

  • PDF

Microwave Cure of Rubber Compound for Tire Tread (타이어 트레드용 고무배합물의 마이크로파 가황)

  • Han, Shin;Kang, Yong-Gu;Sohn, Bong-Young;Oh, Sei-Chul;Park, Chan-Young
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.2 no.1
    • /
    • pp.69-75
    • /
    • 1999
  • Intending to develop a new rubber curing process using only microwave, the both the characteristics of cure and the mechanical properties of rubbers for the tire tread, for which a green styrene-butadiene compounds had been cured with 2.45 GHz microwave, have been compared with those of the custom thermal cured rubber. The unintentional hot spot formation in the compound during the microwave curing has not found where the compound has a microwave absorbing ceramic powders in 4.18 weight percents and the supplying voltage has been adjusted to 90 volts. The new microwave process accomplished preheating to 418K in a quarter of the thermal cure time. The average tensile strength of the microwave-cured rubber indicating $190kg/cm^3$ was compatible to that of the thermal cure. In conclusion, the new microwave cure had approved to be applicable in a commercial plant.

  • PDF

Prediction Models to Control Pro-chlorination in Water Treatment Plant (정수장 후염소 공정제어를 위한 예측모델 개발)

  • Shin, Gang-Wook;Lee, Kyung-Hyuk
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.2
    • /
    • pp.213-218
    • /
    • 2008
  • Prediction models for post-chlorination require complicated information of reaction time, chlorine dosage considering flow rate as well as environmental conditions such as turbidity, temperature and pH. In order to operate post-chlorination process effectively, the correlations between inlet and outlet of clear well were investigated to develop prediction models of chlorine dosages in post-chlorination process. Correlations of environmental conditions including turbidity and chlorine dosage were investigated to predict residual chlorine at the outlet of clear well. A linear regression model and autoregressive model were developed to apply for the post-chlorination which take place time delay due to detention in clear well tank. The results from autoregressive model show the correlationship of 0.915~0.995. Consequently, the autoregressive model developed in this study would be applicable for real time control for post chlorination process. As a result, the autoregressive model for post chlorination which take place time delay and have multi parameters to control system would contribute to water treatment automation system by applying the process control algorithm.

Stress Classification Using Artificial Neural Networks and Fatigue Life Assessment (인공신경망을 이용한 계측응력 분류 및 피로수명 평가)

  • Jung Sung-Wook;Chang Yoon-Suk;Choi Jae-Boons;Kim Young-Jin
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.30 no.5 s.248
    • /
    • pp.520-527
    • /
    • 2006
  • The design of major industrial facilities for the prevention of fatigue failure is customarily done by defining a set of transients and performing a calculation of cumulative usage factor. However, sometimes, the inherent conservatism or lack of details as well as unanticipated transients in old plant may cause maintenance problems. Even though several famous on-line monitoring and diagnosis systems have been developed world-widely, in this paper, a new system fur fatigue monitoring and life evaluation of crane is proposed to reduce customizing effort and purchasing cost. With regard to the system, at first, comprehensive operating transient data has been acquired at critical locations of crane. The real-time data were classified, by using adaptive resonance theory that is one of typical artificial neural network, into representative stress groups. Then the each classified stress pattern was mapped to calculated cumulative usage factor in accordance with ASME procedure. Thereby, promising results were obtained fur the crane and it is believed that the developed system can be applicable to other major facilities extensively.

Resistance Reduction of a High Speed Small Boat by Air Lubrication

  • Jang Jin-Ho;Kim Hyo-Chul
    • Journal of Ship and Ocean Technology
    • /
    • v.10 no.1
    • /
    • pp.1-9
    • /
    • 2006
  • The resistance reduction by an air lubrication effect of a large air cavity covering the hull bottom surface and the similarity relations involved have been investigated with a series of towing tank tests of three geometrically similar models. The test results of geometrically similar models have indicated that a large air cavity was formed beneath the bottom having a backward-facing step by artificially supplying air is effective for resistance reduction. The areas of air cavity and the required flow rates of air are directly related to the effective wetted surface area. The traditional extrapolation methods seem to be applicable to the estimation of the resistance in the tested range if corrections are made to account the changes in the frictional resistance caused by the changes in the effective wetted surface area. To investigate the effectiveness of air lubrication in improving the resistance performance of a practical ship, a small test boat having a backward-facing step under its bottom has been manufactured and speed trials in a river have been performed. Air has been supplied artificially into the downstream region of the bottom step to form a large air cavity covering the bottom surface. The results have confirmed the practical applicability of air lubrication for the resistance reduction of a small high-speed boat.

The development standard research for railway safety software (철도 안전 소프트웨어를 위한 개발 기준 연구)

  • Lee, Young-Jun;Kim, Jang-Yoel;Cha, Kyung-Ho;Cheon, Se-Woo;Lee, Jang-Soo;Kwon, Ki-Choon;Jung, Ui-Jin
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.968-973
    • /
    • 2007
  • The systems such as the railway control system, satellite control system and nuclear power plant control system are the safety critical systems because the failure of them could lead to risk significant events. These softwares of digital systems must follow the life cycle process from the beginning of software development to guarantee their safety and reliability. The NRC(Nuclear Regulatory Commission) Reg Guide of nuclear fields, the RTCA/DO-178B standard which is used to acquire the certification for software in industrial aero field in European Union and United State, the DEF STAN 00-55 standard for the safety of electronic weapon in England, the IEC 601-1-4 for medical equipment and the IEC 62279 for railway system recommended the development life cycle. This paper introduces the development process and compares each other. Also it indicates applicable development criteria for the software of systems related to railway fields and describes the detailed procedure of development criteria. We describe the procedure to make the software development criteria in nuclear filed. For the software development related to railways, the process from plan phase to maintenance phase must be satisfied. The safety and reliability is guaranteed through these standards.

  • PDF

Membrane Diffusion through Flexible-Wall Permeameter for Soil Flushing Tests (연성벽체 투수기를 이용한 흙세척 실험시 벽막을 통한 확산량 산정)

  • Junboum Park;Jee-Sang Kim
    • Journal of Korea Soil Environment Society
    • /
    • v.2 no.2
    • /
    • pp.95-103
    • /
    • 1997
  • Solvent extraction using aqueous solutions is presumed as one of the most effective methods applicable to in situ conditions without excavation of contaminated soils. Laboratory permeameter soil flushing test is performed to describe the process of solvent extraction of contaminants absorbed on soil particles. When the permeameter tests conducted, diffusion of contaminants through the permeameter flexible-wall was considered for adjusting the remediation percentage. Input and output balance for concentration was well matched in the permeameter tests. Nitrobenzene diffused so excessively (approximately 75%) that it was not suitable for the permeameter desorption tests. No biodegradation was detected in the soil samples.

  • PDF

A study on Applicable to Advanced treatment of using Side Stream Plug-Flow Reactor (효과적 공간활용을 위한 Side Stream Plug-Flow Reactor를 이용한 하수 고도처리 공정 적용에 관한 연구)

  • Kim, samju;Hyun, InHwan;Dockko, Suk
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.3
    • /
    • pp.367-372
    • /
    • 2008
  • This study configured the conventional $A^2O$ (Anaerobic-Anoxic-Aerobic bioreactor) system which the fixed media immersed into the anoxic reactor(Named PFR system : Plug Flow Reactor) for evaluating the removal efficiency of nitrogen in the wastewater. The experimental equipment was a cylinder which was consist of 4 pleated PE Pipes(Length 330M, Diameter 100mm) including 2 rope shape media. As a result, the average effluent T-N removal efficiency of the conventional $A^2O$ system was 17.9, 40.3, 50.6, 44.6% in each mode, but the average effluent T-N removal efficiency of the PFR system could achieve 38.8, 57.1, 71.8, 65.4% in each mode. It indicated that the PFR system caused to the increasing of C/N ratio that effected to the increasing of the denitrification efficiency. Not only the effective T-N removal efficiency but also the controllable install space will give advantages for retrofitting of the wastewater treatment plant with the conventional treatment system to the PFR system.

Plasticity of clay bodies containing bottom ashes from power plant (석탄 바닥재를 함유한 점토 소지의 가소성에 관한 연구)

  • Jeon, Hye-Jin;Kim, Yoo-Taek
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.17 no.5
    • /
    • pp.223-230
    • /
    • 2007
  • Plasticity of clay bodies containing bottom ashes(BA) and small portion of other wastes was investigated. Plasticity indices of clay bodies using Atterberg limits were measured. It was confirmed that the plasticity indices could be applicable in actual forming process by extrusion. The forming possible compositions were found by changing the contents of water, bottom ash, stone dust, and sewage sludge. The relationship between the plasticity and physical properties of the aggregate green body was also investigated. The compositions for extrusion forming can be expected by measured the plasticity indices and these results were confirmed by real extrusion process. There is also strong relationship between the plasticity indices and the property of aggregate green body.

Indoor Temperature Control of an Air-Conditioning System Using Model Predictive Control (모델예측제어를 이용한 에어컨 시스템의 실내온도 제어)

  • Jo, Hang-Cheol;Byeon, Gyeong-Seok;Song, Jae-Bok;Jang, Hyo-Hwan;Choe, Yeong-Don
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.4
    • /
    • pp.467-474
    • /
    • 2001
  • The mathematical model of a air-conditioning system is generally very complex and difficult to apply to controller design. In this paper, simple models applicable to the controller design are obtained by modeling the air-conditioning system by single-input single-output between compressor speed and indoor temperature, and by multi-input single-output between compressor speed, indoor fan speed and indoor temperature. Using these empirical models, model predictive control(MPC) technique was implemented for indoor temperature control of the air-conditioning system. It has been shown from various experiments that the indoor temperature control based on the MPC scheme yields reasonably good tracking performance with smooth changes in plant inputs. this multi-input multi-output MPC approach can be extended to multi air- conditioning systems where the conventional PID control scheme is very difficult to apply.