• Title/Summary/Keyword: Apparent Discharge

Search Result 63, Processing Time 0.023 seconds

Partial Discharge Characteristics of Metallic Particles Under HVDC in SF6 Gas (SF6 가스 중 HVDC에서 금속 파티클의 부분방전 특성)

  • Kim, Sun-Jae;Jo, Hyang-Eun;Wang, Guoming;Yun, Min-Young;Kil, Gyung-Suk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.12
    • /
    • pp.831-836
    • /
    • 2015
  • This paper dealt with the PD (partial discharge) characteristics produced by metallic particles presented in a gas insulated switchgear. Four types of metallic particles such as a ball, a trapezoid, a rectangle, and a twist were fabricated and placed in a PD cell filled with $SF_6$ gas. PD pulses were detected through a $50{\Omega}$ non-inductive resistor. Calibration was carried out according to IEC 60270 and the sensitivity was calculated as 4 mV/pC. Apparent charge, pulse count, DIV (discharge inception voltage), DEV (discharge extinction voltage), and TRPD (time resolved partial discharge) were analyzed. Among the metallic particle types, the twist frequently occurred PD pulse at the lowest DIV, while the rectangle showed the highest. DEV of the twist was about 2 times lower than that for the rectangle. Kurtosis of ball clustered at high value, and skewness of other three metallic particles distributed at low value. TRPD showed different distribution by metallic particle types.

Hydraulic Experiments on the Measuring Equipments of Ronoff and Soil Loss (유출수 및 유실토량 측정장치에 관한 수리시험)

  • 유한열
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.10 no.1
    • /
    • pp.1377-1387
    • /
    • 1968
  • In order to measure runoff and soil losses produced in a small test plot during rainfall, it is usually insufficient to use a tank only, necessitating the combined use of a main tank and a subsidiary tank. Accordingly. exact measurement largely depends on how to connect those two measuring tanks. The main purpose of this thesis is to improve the connecting parts of two measuring tanks so as to assure exact measurement of runoff and soil losses. In this experiment, two types of main tank, i. e. A-type and B-type, were used. A-type is a square tank having a flume at its end. At the flume, ten apertures are provided by using metal columns so as to be able to catch one tenth of total muddy flow discharging at the end of the flume, One tenth of total flow is led to the subsidiary tank through a slot sampler fixed to an aperture. B-type differes in that its flume does not have apertures and slot sampler is fixed directly to the end of the flume, other features being the same as those of A-type. Discharge volumes were measured by using weighing tanks and compared. The effect of baffle screen provided in the flume was also observed in connection with exact measurements. In order to keep main tank and its flume in a horizontal position, bolts and nuts mechanism was used. Vertical and horizontal screens were provided in the main to prevent coarse sands coming into the flume. The conclusion derived through this experiment is as follows: (1) The discharge through slot sampler at each aperture is almost the same for A-type. However, it is slightly more than one tenth of total discharge volume. (2) In case that baffle screen is provided in the flume of A-type tank, the discharge volume of slot sampler is less than that of the same type without screen. (3) For B-type tank, slot sampler discharge increases as slot sampler nears toward the center of flume. (4) When baffle screen is provided in the flume of B-type, slot sampler discharge is less than that of the same type without screen, and this phenomenon is more apparent as compared with A-type. (5) In case that the slot width of slot sampler for B-type is one inch, slot sampler discharge exceeds one tenth of total discharge volume. (6) When the slot width for B-type is 15/16 inch and slot sampler is fixed 3/8 inch apart from either flume wall, slot sampler discharge is approximately equal to one tenth of total discharge volume.

  • PDF

An Estimation of the Amount of Ship's Ballast Water to be Discharged at Korean Major Ports (국내 주요항만에서의 선박평형수 배출량 추정)

  • Choi, Hark-Sun;Kim, Han-Soo;Lee, Seung-Guk
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.12 no.4
    • /
    • pp.284-288
    • /
    • 2009
  • The International Convention for the Control and Management of Ships Ballast Water & Sediments was adopted by consensus at a diplomatic conference of IMO at 2004. To prepare the Ballast Water Management Convention, fundamental technologies such as treatment system, type approval, risk assessment and various technical informations for formulation of the regulation for national strategy shall be developed. The information item of voyage and discharge of ship's ballast water are gathered by visiting vessel and agent at port. Using the 97 results by ships type characteristic analysis on the relation between loading/unloading and discharge/uptake of ballast water, the amounts of discharge/uptake of ballast water at each port and all of country in Korea are predicted. Hence, It is apparent that the uptake of ballast water is predicted to about 70 million ton in total of Busan, Incheon, Kwangyang and Ulsan ports at 2006 which is over 3 times than discharges.

  • PDF

The Effect of Pad Groove Density on CMP Characteristics (패드 그루브의 밀도변화가 연마특성에 미치는 영향)

  • Park Kihyun;Jung Jaewoo;Lee Hyunseop;Seo Heondeok;Jeong Seokhun;Lee Sangjik;Jeong Haedo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.8 s.173
    • /
    • pp.27-33
    • /
    • 2005
  • Polishing pads play an important role in chemical mechanical polishing(CMP) which has recently been recognized at the most effective method to achieve global planarization. In this paper, we have investigated CMP characteristics as a change of groove density of polishing pads. The parameter $(K_n)$ is proposed to estimate groove density of pad. The $K_n$ is defined as groove area divided by pitch area. As the groove density value increased, removal rate increased to some point and then gradually saturated in case of increasing the groove density excessively. In addition Within wafer non-uniformity(WIWNU) worse as groove density increased excessively, although WIWNU improved as groove density increased. Also the uniformity of temperature of pad surface decreased as the groove density increased. It was because that the cooling effect increased as groove density increased. In other words, increasing the groove density which means the apparent contact area of pad has influence on amount of discharge of slurry during polishing process.

A Study on the Bathochromic of Poly(Ethylene Terephthalate) Fabrics by Plasma Polymerization (Plasma polymerization에 의한 PET 직물의 심색화에 관한 연구)

  • Cho, Hwan;Kim, Han-Ki;Jang, Byung-Yul;Lee, Kwang-Woo;Cho, In-Sool;Heo, Man-Woo
    • Textile Coloration and Finishing
    • /
    • v.5 no.3
    • /
    • pp.194-205
    • /
    • 1993
  • Plasma polymerization in prepared glow discharge was carried out to improve the bathochromic of dyed PET fabrics by using silicon containing vinyl monomer in plasma polymerization equipment which consists of a pair of electrodes was connected to the 13.56MHz RF generator. The optimum condition for the bathochromic effect was investigated on various plasma polymeriztion parameters. By plasma polymerization used silicon containing vinyl monomer, the bathochromic of dyed PET fabrics was very enhanced. The optimum conditions on this equipment were as follows ; electrode distance : 3cm, discharge output : 60W, gas pressure : 0.3 Torr, monomer flow rate : 30㎤/min. plasma polymerization time : 60sec. The apparent strength of plasma polymerized PET fabrics was increased about 40∼47% with decreasing about 3 of L value.

  • PDF

A Possible Application of the PD Detection Technique Using Electro-Optic Pockels Cell With Nonlinear Characteristic Analysis on the PD signals

  • Kang, Won-Jong;Lim, Yun-Sok;Chang, Young-Moo;Koo, Ja-Yoon
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.11C no.2
    • /
    • pp.6-11
    • /
    • 2001
  • Abstract- In this paper, a new Partial Discharge (PD) detection using Pockels cell was proposed and considerable apparent chaotic characteristics were discussed. For this purpose, PD was generated from needle-plane electrode in air and detecte by optical measuring system using Pockels cell, based on Mach-Zehner interferometer, consisting of He-Ne laser, single mode optical fiber, 50/50 beam splitter and photo detector. In addition, the presence of chaos of the PD signals has been investigated by examining their means of qualitative and quantitative information. For the former, return map and 3-dimensional strange attractor have been drawn in order to investigate the presence of chaotic characteristics relevant to PD signals, detected through CT and Peckels sensor respectively, in the normalized time series. The presence of strange attractor indicates the existence of fractal structures in it's phase space. For the latter, several dimension values of strange attractor were verified sequentially. Throughout this paper, it is likely that the chaotic characteristics regarding the PD signals under air are verified.

RADIOLOGIC STUDY OF THE MAXILLARY SINUSITIS (상악동염의 방사선학적 연구)

  • Choi Soon Chul
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.11 no.1
    • /
    • pp.41-50
    • /
    • 1981
  • Radiographic features of maxillary sinusitis, types of mucosal thickening, types of bony wall change, and relationship between the radiographic features and symptoms of patients were observed and classified in the Waters' view of 360 patients with 441 maxillary sinuses demonstrating radiologic changes. And the classification of antral floor and pathologic change was observed in the 154 periapi- cal films. Finally, the value of orthopantomography in the diagnosis of maxillary sinusitis was evaluated in the 138 cases, The obtained results were as followings. 1. Among 441 maxillary sinuses examined by Waters' projection, mucosal thickening was seen in 56.7% and generalized opacification was seen in 36.3%. 2. Among 270 mucosal thickenings classified 8 types, overall regularly thickened type was the highest in incidence (36.3%). 3. Bony wall change was seen in 35.6% of all cases and the indistinct white line of the cortical plates was the highest in incidence (78.2%) among the 6 types. 4. Pain (41.9%) and pus discharge (21.0%) were the most frequent symptoms. And pus discharge, foul odor, and headache was more prevalent in type of generalized opacification than any other types. 5. Regular pneumatization involving all roots of premolars and molars was the highest in incidence (55.0%). The first molar presented the most frequent involvement (61.0%). 6. In orthopantomography, 46.4% showed apparent increased radiopacity and 23.9% showed suspicious increased radiopacity in comparison to Waters' projection.

  • PDF

A Study on the New Evaluation Method on Insulation of Electronic Components (전자부품의 새로운 절연평가기법 연구)

  • Kil, Gyung-Suk;Snog, Jae-Yong;Moon, Seung-Bo;Cha, Myung-Soo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.503-504
    • /
    • 2006
  • This paper describes a low-level partial discharge(PD) testing that has been accepted as a non-destructive test method on insulation performance of electronic components. A comparative PD analysis combined with the Withstand Voltage Test (WVT) specified in IEC standards is carried out on high frequency switching transformers. The analysis shows that insulation degradation of the transformers under test progresses during the WVT. To avoid insulation degradation of the specimen, PD test has to be carried out at as low voltage as possible. In this study, the PD test on the transformers is performed in ranges from 50% to 70% of the test voltage specified in the WVT by measuring apparent charges below 1 pC. From the experimental results, it is expects that the low-level PD test is applicable for electronic components as a replacement of the WVT.

  • PDF

Thermal Stimulated Conductivity in Cellulose Triacetate-Multiwalled Carbon Nanotube Polymer Films

  • Basavaraja, C.;Jo, Eun-Ae;Kim, Bong-Sung;Huh, Do-Sung
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.8
    • /
    • pp.2207-2210
    • /
    • 2010
  • This paper describes the preparation and study of thermally stimulated discharge conductivity (TSDC) study of cellulose triacetate (CTA) - multiwalled carbon nanotubes (MWNTs) film thermoelectrets. TSDC has been carried out in the temperature range 308 - 503 K and at four different polarizing fields. The conductivity of the polymer blends increased with increase in temperature showing a semi-conducting behavior. The apparent activation energy also showed a pronounced effect with the increase in the content of MWNTs.

Operating Characteristics of a Continuous Two-Stage Bubbling Fluidized-Bed Process (연속식 2단 기포 유동층 공정의 운전특성)

  • Youn, Pil-Sang;Choi, Jeong-Hoo
    • Korean Chemical Engineering Research
    • /
    • v.52 no.1
    • /
    • pp.81-87
    • /
    • 2014
  • Flow characteristics and the operating range of gas velocity was investigated for a two-stage bubbling fluidized-bed (0.1 m-i.d., 1.2 m-high) that had continuous solids feed and discharge. Solids were fed in to the upper fluidized-bed and overflowed into the bed section of the lower fluidized-bed through a standpipe (0.025 m-i.d.). The standpipe was simply a dense solids bed with no mechanical or non-mechanical valves. The solids overflowed the lower bed for discharge. The fluidizing gas was fed to the lower fluidized-bed and the exit gas was also used to fluidize the upper bed. Air was used as fluidizing gas and mixture of coarse (< $1000{\mu}m$ in diameter and $3090kg/m^3$ in apparent density) and fine (< $100{\mu}m$ in diameter and $4400kg/m^3$ in apparent density) particles were used as bed materials. The proportion of fine particles was employed as the experimental variable. The gas velocity of the lower fluidized-bed was defined as collapse velocity in the condition that the standpipe was emptied by upflow gas bypassing from the lower fluidized-bed. It could be used as the maximum operating velocity of the present process. The collapse velocity decreased after an initial increase as the proportion of fine particles increased. The maximum took place at the proportion of fine particles 30%. The trend of the collapse velocity was similar with that of standpipe pressure drop. The collapse velocity was expressed as a function of bulk density of particles and voidage of static bed. It increased with an increase of bulk density, however, decreased with an increase of voidage of static bed.