• 제목/요약/키워드: Apparatus Capacity

검색결과 175건 처리시간 0.022초

Development of umbrella anchor approach in terms of the requirements of field application

  • Evirgen, Burak;Tuncan, Ahmet;Tuncan, Mustafa
    • Geomechanics and Engineering
    • /
    • 제18권3호
    • /
    • pp.277-289
    • /
    • 2019
  • In this study, an innovative anchoring approach has been developed dealing with all relevant aspects in consideration of previous works. An ultimate pulling force calculation of anchor is presented from a geotechnical point of view. The proposed umbrella anchor focuses not only on the friction resistance capacity, but also on the axial capacity of the composite end structure and the friction capacity occurring around the wedge. Even though the theoretical background is proposed, in-situ application requires high-level mechanical design. Hence, the required parts have been carefully improved and are composed of anchor body, anchor cap, connection brackets, cutter vanes, open-close ring, support elements and grouting system. Besides, stretcher element made of aramid fabric, interior grouting system, guide tube and cable-locking apparatus are the unique parts of this design. The production and placement steps of real sized anchors are explained in detail. Experimental results of 52 pullout tests on the weak dry soils and 12 in-situ tests inside natural soil indicate that the proposed approach is conservative and its peak pullout value is directly limited by a maximum strength of anchored soil layer if other failure possibilities are eliminated. Umbrella anchor is an alternative to conventional anchor applications used in all types of soils. It not only provides time and workmanship benefits, but also a high level of economic gain and safe design.

모래다짐말뚝(SCP) 시공지반의 지지력에 관한 실험적 연구 (Experimental Study on Bearing Capacity of Ground Treated by Sand Compaction Piles)

  • 김병일;김영욱;이상익;최용성
    • 한국지반공학회논문집
    • /
    • 제20권4호
    • /
    • pp.39-47
    • /
    • 2004
  • 모래다짐말뚝(sand compaction pile)공법은 연약지반에 모래말뚝을 다져 시공하는 지반개량공법으로 최근 우리나라에서 많이 사용되고 있다. 모래다짐말뚝이 시공된 지반의 지지력을 산정하는 공식은 여러 개가 있으나 대부분 모래다 짐말뚝의 치환율은 고려하지 않고 있다. 이 연구에서는 20, 30% 및 40%의 치환율로 복합지반을 무리형태로 조성하여 원심력 압밀시험기를 이용하여 압밀시킨 후, 재하시험을 실시하여 모래다짐말뚝이 시공된 지반의 지지력 특성을 파악하는 모형시험을 수행하였다. 또한, 치환율을 고려한 복합지반의 지지력을 구하기 위해서 치환율에 따라 가중평균하여 지지력을 구할 수 있는 식을 제시하였으며 그에 대한 적용성을 검토하기 위해서 시험결과와 제안 식에 의한 복합지반의 지지력을 비교 검토하였다.

개설된 직접전단시험기(CNS)를 이용한 보강재의 인발력 추정 (Estimation of Pull-out force by using modified Direct Shear Apparatus)

  • 유병선;이학무;장기태;한희수
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2003년도 사면안정학술발표회
    • /
    • pp.145-154
    • /
    • 2003
  • When a nail pulled out in dense, granular soil, the soil in the vicinity of the nail tends to dilate, but its dilatancy results in a normal stress concentration at the soil/nail interface, thereby increasing the pull-out resistance of the inclusion. It is thought to be occurring within the resistance zone where the soil mass is at stationary state and the reinforcement are held in position by the soil, due to the friction or bond. In this paper, A series of direct shear and interface tests were conducted by using so called‘Constant Normal Stiffness Test Apparatus’which was modified and improved from the conventional direct shear box test rig. Unlikely the normal shear box test, this enables to simulate the different constraint effects of surrounding soil during shear under the conditions of constant stress and volume, constant normal stiffness. The aim of the research programme is to get better understanding of pull-out bond mechanism, thus to explore the possibility of evaluating the pull-out bond capacity of soil/reinforcement at the preliminary design stage from the laboratory test.

  • PDF

Different Susceptibilities to Low Temperature Photoinhibition in the Photosynthetic Apparatus Among three Cultivars of Cucumber (Cucumis sativus L.)

  • Oh, Kwang-Hoon;Lee, Woo-Sung;Lee, Choon-Hwan
    • Journal of Photoscience
    • /
    • 제8권3_4호
    • /
    • pp.105-112
    • /
    • 2001
  • Susceptibility to low temperature photoinhibition in photosynthetic apparatus was compared among three cucumber cultivars, Gahachungjang (GH), Banbaekjijeo (BB) and Gaeryangsymji (GR). By chilling in the light for 6 h, a sustained decrease in the potential quantum yield (Fv/Fm) and the oxidizable P700 contents was observed, and the decrease was less in GH than in BB and GR. Although the difference was small, some $\Phi_{PSII}$ remained in GH after light-chilling for 6 h indicating that a few electrons can flow around photosystem II(PSII). As a consequence, the primary electron acceptor of PSII, $Q_{A}$, was reduced slowly and was not fully reduced after light-chilling for 6 h in GH. Although the amplitude was small, the development of NPQ was also faster in GH, indicating a higher capacity for non-photochemical energy dissipation. The relative fraction of a fast relaxing component of NPQ (qf) was higher in GH. After light-chilling for 5 h, the values of qf in BB and GR became much smaller than that in GH, indicating BB and GR suffered more significant uncoupling of ATPase and/or irreversible damages in PSII. When fluorescence induction transients were recorded after chilling, significant differences in quenching coefficients (qQ and qN) were observed among the three cultivars.

  • PDF

Cryoscopy 裝置와 方法의 改良에 關한 硏究 (On Automatic Apparatus for Cryoscopy and Improvement in Experimental Method)

  • 신윤경;이준
    • 대한화학회지
    • /
    • 제18권2호
    • /
    • pp.143-149
    • /
    • 1974
  • 從來에 開發된 cryoscopy 裝置는 手動型으로서 一回測定에 所要되는 最少 한時間을 두사람이 測定에 꼬박 關與하여야 하는 不便을 갖는다. 뿐만 아니라 手動攪拌에 依한 不規則的攪拌速度에서 오는 誤差나, Beckmann 溫度計의 感溫部가 나타내는 큰 熱容量 및 判讀時의 視角差차와 波勞度에서 오는 誤差等이 不可避하게 作用한다. 그러므로 本 硏究에서는 이들 誤差를 減少시키기 爲하여 다음과 같이 裝置改良에 依한 自動測定法을 開發하였다. (1) 水槽溫度의 自動精密調節 (2) 感溫部의 熱容量이 매우 작은 thermistor에 依한 溫度測定 (3) 檢流計의 反射光을 感光紙에 照射시켜 轉移溫度를 自動記錄하는 이른바 溫度自動記錄裝置의 開發 (4) 攪拌裝置의 自動化 한편 從前부터 使用되어 오는 10水和物 芒硝는 加入時 一部가 容器壁에 묻어 反應에 關與하지 못하며, 또한 10水和物화물을 部分的으로나마 脫水되지 않은채 保存하여 測定에 使用하기는 어려우므로 本硏究에서는 無水芒硝를 써서 하는 實驗條件을 아울러 究明하였다.

  • PDF

Experimental investigation of two-phase natural circulation loop as passive containment cooling system

  • Lim, Sun Taek;Kim, Koung Moon;Kim, Haeseong;Jerng, Dong-Wook;Ahn, Ho Seon
    • Nuclear Engineering and Technology
    • /
    • 제53권12호
    • /
    • pp.3918-3929
    • /
    • 2021
  • In this study, we experimentally investigate of a two-phase natural circulation loop that functions as a passive containment cooling system (PCCS). The experimental apparatus comprises two loops: a hot loop, for simulating containment under severe accidents, and a natural circulation loop, for simulating the PCCS. The experiment is conducted by controlling the pressure and inlet temperature of the hot loop in the range of 0.59-0.69 MPa (abs) and 119.6-158.8 ℃, respectively. The heat balance of the hot loop is established and compared with a natural circulation loop to assess the thermal reliability of the experimental apparatus, and an additional system is installed to measure the vapor mass flow rate. Furthermore, the thermal-hydraulic characteristics are considered in terms of a temperature, mass flow rate, heat transfer coefficient (HTC), etc. The flow rate of the natural circulation loop is induced primarily by flashing, and a distortion is observed in the local HTC because of the fully develop as well as subcooled boiling. As a result, we present the amount of heat capacity that the PCCS can passively remove according to the experimental conditions and compared the heat transfer performance using Chen's and Dittus-Boelter correlation.

흐름방향과 압밀응력이 지반의 수리저항특성에 미치는 영향 (Effects of Flow Direction and Consolidation Pressure on Hydraulic Resistance Capacity of Soils)

  • 김영상;정신현;이창호
    • 한국지반환경공학회 논문집
    • /
    • 제16권5호
    • /
    • pp.55-66
    • /
    • 2015
  • 우리나라 남서해안의 조차는 지역에 따라 3~8m까지 발생하며 이 지역의 풍력기초들은 조류의 다양한 흐름에 의한 세굴로 전체 구조물에 예상치 못한 진동에 의한 장기적인 불안정성이 야기될 수 있다. 본 연구에서는 흐름방향을 고려할 수 있도록 개선된 관수로식 수리저항성능 실험기를 이용하여 압밀압력과 흐름방향의 변화가 지반의 수리저항성능에 미치는 영향을 검토하였다. 실험결과 양방향 흐름에 노출된 시료의 세굴률이 일방향 흐름에서보다 크며, 한계전단응력은 감소하여 세굴에 더욱 취약해지는 것으로 나타났다. 또한 압밀압력이 증가함에 따라 세립질 토사의 한계전단응력과 같은 수리저항특성은 증가하여 세굴에 대한 저항성이 증가하나 조립토의 수리저항 성능은 크게 변화하지 않았다. 지반공학적 특성과 수리저항특성의 상관관계를 검토한 결과, 비배수전단강도는 한계전단응력과 비례관계이며 세립토 및 조립토의 흙 분류와 관계없이 하나의 상관관계로 효과적으로 한계전단응력을 예측할 수 있는 것으로 나타났으며 전단파 속도는 한계전단응력과 비례관계에 있으며 조립토와 세립토의 영역에 따라 비교적 명확히 구분되었다.

Model tests on bearing capacity and accumulated settlement of a single pile in simulated soft rock under axial cyclic loading

  • Zhang, Benjiao;Mei, Can;Huang, Bin;Fu, Xudong;Luo, Gang;Lv, Bu
    • Geomechanics and Engineering
    • /
    • 제12권4호
    • /
    • pp.611-626
    • /
    • 2017
  • The research reported herein is concerned with the model testing of piles socketed in soft rock which was simulated by cement, plaster, sand, water and concrete hardening accelerator. Model tests on a single pile socketed in simulated soft rock under axial cyclic loading were conducted and the bearing capacity and accumulated deformation characteristics under different static, and cyclic loads were studied by using a device which combined oneself-designed test apparatus with a dynamic triaxial system. The accumulated deformation of the pile head, and the axial force, were measured by LVDT and strain gauges, respectively. Test results show that the static load ratio (SLR), cyclic load ratio (CLR), and the number of cycles affect the accumulated deformation, cyclic secant modulus of pile head, and ultimate bearing capacity. The accumulated deformation increases with increasing numbers of cycles, however, its rate of growth decreases and is asymptotic to zero. The cyclic secant modulus of pile head increases and then decreases with the growth in the number of cycles, and finally remains stable after 50 cycles. The ultimate bearing capacity of the pile is increased by about 30% because of the cyclic loading thereon, and the axial force is changed due to the applied cyclic shear stress. According to the test results, the development of accumulated settlement is analysed. Finally, an empirical formula for accumulated settlement, considering the effects of the number of cycles, the static load ratio, the cyclic load ratio and the uniaxial compressive strength, is proposed which can be used for feasibility studies or preliminary design of pile foundations on soft rock subjected to cyclic loading.

다층형 열교환기를 이용한 제습기의 전면 풍속 변화에 따른 성능 특성에 관한 연구 (A Study on Performance Characteristics of a Dehumidifier with Multi-layer Type Heat Exchangers Varying Frontal Air Velocity)

  • 구학근
    • 한국산학기술학회논문지
    • /
    • 제11권7호
    • /
    • pp.2323-2327
    • /
    • 2010
  • 저온환경에서의 자동화 설비, 반도체, 제조공정 및 수분 접촉이 되는 화학생산 라인 공정 등의 수분 제거를 위하여 다층형 열교환기를 이용한 제습장치를 구성하였다. 이 장치의 주요구성은 핀 피치가 다른 증발기 4대, 2대의 압축기, 2대의 응축기 그리고 팽창밸브로 각각 제작되었다. 본 연구에서는 제 1 열교환기(증발기)의 전면 풍속을 변화시켜 제습기의 성능 특성을 분석하였다. 즉, 제1 열교환기의 정면 풍속을 1.0m/s에서 4.0m/s까지 0.5 m/s의 간격으로 증가시켜 각 측정지점에서 온도와 상대습도를 측정하여 엔탈피를 구하여 각 열교환기의 냉각능력을 구했다. 그 결과 제1 열교환기의 정면 풍속이 2.0 m/s에서 각 열교환기의 냉각능력이 가장 좋은 것을 알 수 있었다.

분산전원이 도입된 배전계통의 보호협조 해석방법 (Protection Coordination Analysis for Distribution Systems Integrated with Distributed Generation)

  • 김재언;김의환
    • 한국산학기술학회논문지
    • /
    • 제12권5호
    • /
    • pp.2279-2284
    • /
    • 2011
  • 기존의 수지상 배전계통은 사고 등에 대한 설비보호 및 전력공급 신뢰도 향상을 위하여 과전류보호협조방식을 채택하고 있다. 국내 배전계통의 경우, 그 보호방식 협조체계는 배전용변전소 동일 변압기 동일 모선에서 다수의 배전선이 각각 CB(변전소 차단기)를 통하여 인출되어 각 배전선로 이하에서 사고발생시 고장전류를 검출하여 해당 CB를 차단하도록 되어있다. 그러나, 이와 같은 보호방식을 채용하고 있는 배전계통에 분산전원이 도입될 경우 변전소 인출차단기의 차단용량은 영향을 받게 되므로 충분한 검토가 필요하다. 본 논문에서는 분산전원 도입시, 국내 배전용 변전소의 인출차단기에 대한 차단용량을 초과하지 않는 보호협조방법을 제시하고, 이를 PSCAD-EMTDC 계통해석 S/W Tool에 의하여 모의하여 검증하였다.