• Title/Summary/Keyword: Apical instrumentation

Search Result 76, Processing Time 0.021 seconds

Effects of Fusion Level for Scioliotic Spine Correction Simulation with Pedicle Screw and Rod Derotation Method (척추경 나사못 고정과 강봉 감염술을 이용한 척추 측만증 교정 해석시 유합 범위에 따른 교정 효과 분석)

  • 김영은;손창규;최형연;하정현;이춘기
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.1
    • /
    • pp.71-76
    • /
    • 2004
  • In order to investigate the Post-operative changes in scoliotic spine according to selection of fusion level a mathematical finite element model of King-Moe type II scoliotics spine system was developed. By utilizing this finite element scoliosis model surgical correction simulation procedures of pedicle fixation and derotation were simulated. In consequence of the calculation by changing the fusion Levels, postoperative changes like Cobb angle, apical vertebrae axial rotation (AVAR), thoracic kyphosis, and rib hump were Qualitatively analyzed. In the analysis of operative kinematics, the decrease or Cobb angle was most prominent in distraction than in deroation. Applying the rod derotation only was not effective in decrease of Cobb angle but just caused increase of At AR and rib hump. From the operative simulation, co-action or distraction and translation during rod insertion has major impact on Cobb angle decrease and maintenance of kyphosis. With rod rotation, Cobb angle decrease was obtained, but combined increase of AVAR and rib hump was simulation observed as well. The case of most extended instrumentation range with 60o rod rotation produced double decrease of Cobb angle, but the increase of rib hump and AYAR occurred corresponding1y. The optimum selection of fusion level was proved as one level less than inflection position of the thoracic spine curvature.

SEM EVALUATION OF THE PREPARED ROOT CANALS BY HAND AND Ni-Ti ROTARY ROOT CANAL INSTRUMENTS (Hand & rotary root canal instrument의 근관내 삭제 형태에 관한 전자현미경적 비교)

  • Oh, Tae-Seok;Park, Jeong-Won
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.1
    • /
    • pp.477-486
    • /
    • 1998
  • Recently the development of rotary instrument makes it possible that in root canal treatment operator saves much more time, maintans original curved canal shape and easily prepares continuous tapered root canal. The purpose of this experiment was to examine the smoothness of the internal surface of prepared root canal and the effectiveness of debridement in prepared root canal by SEM for the comparison of hand and Ni-Ti rotary instrument. 25 extracted human teeth were access opened and # 10 K-type file was introduced into canal until it was appeared at the apical foramen. The working length was established by subtracting 0.5mm from this measurement. Group 1. The root canal preparation was done to # 30 with working length and then step-back until # 45 with K-Flexofile (Maillefer, Swiss). Group 2. Root canal preparation was done by Naviflex Ni-Ti file (Brasseler, USA) as the same technique with group 1. Group 3. Canal was prepared by Profile .04 (Maillefer, Swiss) taper until #30. Group 4. With use of Quantec (Tycom, USA) root canal was prepared from file number 1 to 8. In group 1 and 2, the root canal irrigant was NaOCl and the other groups, NaOCl and RC-prep (Premine Dental Products, USA) was used. The prepared teeth were notched with high-speed bur as bucco-lingual direction and fractured with chisel and mallet, then examined with SEM. Group 1 showed smooth internal surface. There were scratches mainly to the axial direction. Group 2 showed similar characteristics to those in group 1. Group 3 showed more smoother and linear cutting surface with bised scratches. Group 4 has the almost same characteristics group 3 and there was no difference in the file design. Ni-Ti rotary root canal instrument prepare the dentinal wall more smoother than hand instrument. The effectiveness of debridement was not fully affected by file design. The isthmus area and accessory canals of the root canal system were not prepared in any group. According to the result, hand and rotary type instrumentation techniques were effective in removal of major amount of tissue from root canal but it was not complete. In the direction of cutting movement there was difference between them.

  • PDF

A COMPARISON OF THE SHAPING ABILITY OF FOUR ROTARY NICKEL-TITANIUM FILES IN SIMULATED ROOT CANALS (엔진구동형 NiTi 파일의 근관성형효과 비교)

  • Kim, Bo-Hye;Choi, Kyoung-Kyu;Park, Sang-Hyuk;Choi, Gi-Woon
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.2
    • /
    • pp.88-95
    • /
    • 2010
  • The purpose of this study was to compare the root canal shaping ability of 4 rotary NiTi instruments in simulated root canals. For the preparation of thirty two curved root canals, Mtwo instruments using "single length"technique, and Profile, ProTaper Universal, and K3 using crown-down technique (N = 8) were used. All canal samples were prepared by reaching an apical canal size of #30. Pre- and post-instrumentation digital images were recorded and an assessment of canal shape was determined using a computer image analysis program SigmaScan Pro (Systat Software Inc., San Jose, CA, USA). The changes of the dimension of inner walls of canals, (2) the changes of the dimension of outer walls of canals, and (3) the centering ratio were measured at 7 measuring points, and then data were statistically analyzed using one-way ANOVA and Duncan's test. The results were as below; 1. The root canal shaping ability of Profile was significantly faster than that of other rotary NiTi instruments (p < 0.05). 2. The deformation and fracture of all instruments used for this study were not experienced. 3. In the degree of changes of the dimension of inner walls of canals, Profile demonstrated the lowest changes of the dimension of inner walls of canals except at the measuring points of the 1 and 2 mm (p < 0.05). However, the ProTaper Universal showed the highest changes of the dimension of inner walls of canals at all measuring points (p < 0.05). 4. In the degree of changes of the dimension of outer walls of canals, Mtwo demonstrated the lowest changse of the dimension of outer walls of canals except at the measuring point of the 1 mm (p < 0.05). However, Profile exhibited the highest changes of the dimension of outer walls of canals at the measuring points of 3 and 4 mm and ProTaper Universal and K3 showed the largest changes of the dimension of outer walls of canals at the measuring points of 1, 2, 6, and 7 mm (p < 0.05). 5. In degree of centering ratio, Profile demonstrated the least centering ratio comparing with the centering ratio shown by other NiTi instruments at the measuring points of 1, 4, 5, and 6 mm. Results suggest that in the coronal part of canal preparation, active cutting files such as ProTaper Universal may efficiently flare the canal orifice and form a better taper, and in the apical part of the canal, files which have a better centering ability such as Profile may maintain the original canal curvature and reduce the shaping time.

THE EFFECT OF SMEAR LAYER TREATMENT ON THE MICROLEAKAGE (Smear layer 처리에 따른 미세누출에 대한 연구)

  • Lee, Jung-Min;Park, Sang-Hyuk;Choi, Gi-Woon
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.5
    • /
    • pp.378-389
    • /
    • 2006
  • The purpose of this study was to compare the sealing ability of root canal obturation with or without the treatment of smear layer. Eighty extracted human teeth with one canal were selected Instrumentation was performed with crown-down technique. After instrumentation, root canals of the NaOCl group and NaOCl-6 group were irrigated with 3% NaOCl. EDTA group and EDTA-6 group were irrigated with 17% EDTA. Then all teeth were obturated using continuous wane obturation technique NaOCl group and EDTA group were immersed in methylene blue solution for 84hours. NaOCl-6 group and EDTA-6 group were immersed in methylene blue solution for 6months. The teeth were sectioned at 1.5 mn (Level 1), 3.0 mm (Level 2) and 4.5 mm (Level 3) from the root apex. The length of dye-penetrated inter-face and the circumferential length of canal at each level were measured using Sigma-Scan Pro 5.0. 1. The mean leakage ratio was decreased cervically. 2. NaOCl group showed higher mean leakage ratio than EDTA group at each level. But there was significant difference at level 1 only (p < 0.05). 3. NaOCl-6 group showed higher mean leakage ratio than EDTA-6 group at each level. But there was significant difference at level 1 only (p < 0.05). 4. NaOCl-6 group showed higher mean leakage ratio than NaOCl group at each level. But there was significant difference at level 1 only (p < 0.05). 5. EDTA-6 group showed higher mean leakage ratio than EDTA group at each level. But there was no significant difference. 6. In NaOCl group and NaOCl-6 group, scanning electron micrographs of tooth sections generally covered with smear layer. In EDTA group and EDTA-6 group, tooth sections showing the penetration of sealers to opened dentinal tubules. The results suggest that removal of smear layer was effective to reduce the apical microleakage of the root canal.

A COMPARISON OF SHAPING ABILITY OF THE THREE ProTaper® INSTRUMENTATION TECHNIQUES IN SIMULATED CANALS (ProTaper®의 세 가지 사용방식에 따른 성형능력 비교)

  • Kim, So-Youn;Park, Jeong-Kil;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.1
    • /
    • pp.58-65
    • /
    • 2005
  • The purpose of this study was to compare the shaping ability of the three $ProTaper^{(R)}$ instrumentation techniques in simulated canals. Thirty resin blocks were divided into 3 groups with 10 canals each. Each group was instrumented with manual $ProTaper^{(R)}$ (Group M), rotary $ProTaper^{(R)}$ (Group R), and hybrid technique (Group H). Canal preparation time was recorded. The images of pre- and post-instrumented root canals were scanned and superimposed. The amounts of canal deviation, total canal width, inner canal width, outer canal width and centering ratio were measured at apical 1, 2, 3, 4, 5 and 6 mm levels 1. Canal preparation time was the shortest in R group (p < 0.05). 2. The amounts of total canal width in R group was generally larger than the other groups, but no significant differences were observed except at the 1, 3 mm levels (p > 0.05) .3. The amounts of inner canal width in R group was larger than M group at the 1 mm level and H group was larger than R group at the 6 mm level (p < 0.05). The amounts of outer canal width in R group was larger than H group only at the 1 mm level (p < 0.05). 4. The direction of canal deviation in H, R group at the 1, 2, 3 mm levels was outward and that in M group at the 1, 2 mm levels was inward. The amounts of canal deviation in H group was larger than R group at the 6 mm level (p < 0.05). 5. The amounts of centering ratio in H group was larger than R group at the 6 mm level (p < 0.05).

SCANNING ELECTRON MICROSCOPIC STUDY ON THE EFFICACY OF ROOT CANAL WALL DEBRIDEMENT OF ROTARY NI-TI INSTRUMENTS WITH DIFFERENT CUTTING ANGLE (엔진 구동형 니켈-타이타늄 합금파일의 절삭각에 따른 근관성형 효과에 관한 전자현미경적 연구)

  • Jeon, In-Soo;Yoon, Tai-Cheol;Park, Seong-Ho;Kum, Kee-Yeon
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.6
    • /
    • pp.577-586
    • /
    • 2002
  • The purpose of this in vitro study was to compare the effects of root canal cleanness following two Ni-Ti rotary instruments with different rake angle. Thirty-six sound, extracted human premolars with single root were randomly divided into three groups. The used rotary instruments were HEROShaper (Group 1, Micro-Mega, Besancon, France, n=12) and ProFile (Group 2, Maillefer, Ballaigues, Switzerland, n=12). Control group (n=12) was only extirpated with barbed broach (Mani, Matsutani Seisakusho Co., Japan) Group 1 & 2 teeth were prepared to a #40/.04 taper at the apex followed by 1 mm using crown-down technique. After canal preparation and frequent irrigation with 5.25% sodium hypochlorite, the roots split longitudinally into a bucco-lingual direction. Root halves were cross-sectioned in apical third portion again. All root specimens were processed for SEM investigation and photographed. Separate evaluations by one endodontist were undertaken for smear layer on prepared walls with a five score-index for each using reference photograph in root halves. The penetration depth of smear layer into dentinal tubules was also estimated in the other halves. Following results were obtained: 1. Smear layer was observed on all the prepared walls with two experimental groups except control group. 2. Smear layer characteristics in two experimental groups; 1) HEROShaper group showed snowy, dusty appearance and were shown open dentinal tubuli on the prepared walls of almost specimens, and the thickness of smear layer covering onto dentinal surfaces was within 1-2 ${\mu}m$ in a few specimens. 2) ProFile group showed shiny, burnished appearance and complete root canal wall covered by a homogenous smear layer with no open dentinal tubuli in all specimens. The penetration of smear layer into dentinal tubules was found in all specimens and the thickness was at 2-4 ${\mu}m$ in all specimens. These results demonstrated that a completely clean root canal could not be achieved regardless of positive or negative rake angle, which is in accordance with the majority of previous studies on root canal cleanliness In conclusion, through irrigation with antibacterial solutions or chelating agents is recommended to remove the smear layer on prepared canal wall in spite of Ni-Ti instrumentation.