• 제목/요약/키워드: Apex Angle

검색결과 113건 처리시간 0.032초

디지털 흉부 후·전 방향 방사선영상을 이용한 정상 한국인 폐 크기의 영상의학적 계측 (Radiological Measurements of Lung Field Size in Normal Korean using Digital Chest Posteroanterior Radiography)

  • 박여진;주영철;이일수
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권1호
    • /
    • pp.1-6
    • /
    • 2018
  • The purpose of this study is to provide baseline data on lung field size measured radiological method by chest PA image in normal Korean. The subject of this study is 496 normal persons who performed chest PA examination using x-ray digital radiography system. The measurement method is from the apex of right and left lung to the costophrenic angle of both lung, from the top of the image to the lowest costophrenic angle of both lung and transverse line of the largest lung area. As a result of this study, the following conclusions were obtained. A lung field size of male is larger than the female(p<0.05). The younger the age, the longer both lung length and total lung height statistically significant. As a increase height and length, A lung field size was increased(p<0.05). But, BMI is not associated with a lung field size. This study will be data of reference data when radiological technologists perform chest PA examination.

Polarization State of Scattered Light in Apertureless Reflection-mode Scanning Near-Field Optical Microscopy

  • Cai, Yongfu;Aoyagi, Mitsuharu;Emoto, Akira;Shioda, Tatsutoshi;Ishibashi, Takayuki
    • Journal of Magnetics
    • /
    • 제18권3호
    • /
    • pp.317-320
    • /
    • 2013
  • We studied the polarization state in an apertureless scanning near-field microscopy (a-SNOM) operating in reflection mode by using three-dimensional Finite-difference Time-domain (FDTD) method. As a result, the electric field around tip apex in the near-field region enhanced four times stronger than the incident light for ppolarization when the tip-sample separation was 10 nm. We find that the p- and s-polarization state is maintained for the scattered light when the probe is perpendicular to the sample. When the probe is not perpendicular to the sample, the polarization state of scattered light will rotate an angle that equals to the inclination angle of probe with p-polarization illumination. On the other hand, the polarization state will not rotate with s-polarization illumination.

Effects of Three Week 3D Pilates Breathing Exercise on Spinal Curvature, Trunk Imbalance and Alignment of Healthy Adults

  • Kim, Seongyeol
    • 국제물리치료학회지
    • /
    • 제10권2호
    • /
    • pp.1797-1802
    • /
    • 2019
  • Background: Breathing is the essential step of Pilates exercise and can be used to activate core muscles. Although the effects of breathing exercise on pain, breathing muscles, and cervical posture have been extensively studied, little is known about the impact of Pilates breathing on spinal posture and alignment. Purpose: To determine the effect of 3D-Pilates breathing exercise on spinal curvature and alignment of healthy adults during corrected to normal alignment. Design: One group pre-post test design Methods: Eighteen participants were given a 3D-pilates breathing exercise twice a week (20 minutes per session) for three weeks and warmed up for 10 minutes before each exercise session. To examine spinal curvature and alignment of each subject, this study used radiation free rasterstereography (Formetric III, Germany). Paired t-test and Wilcoxon signed rank test were performed to determine the difference between pre and post exercise. Results: There were statistically significant differences in height (p<.001), kyphosis angle (p<.05), trunk imbalance (p<.05), kyphotic apex (p<.01), cervical fleche (p<.05), pelvic tilt (p<.01), and lateral deviation (p<.05) between before and after 3D Pilates breathing exercise. However, there was no significant difference in lordosis angle. Conclusions: The study results indicated that three week 3D-pilates breathing exercise program could be presented as an effective rehabilitation method for improving spinal curvature and alignment.

남자 높이뛰기 BKH 선수를 중심으로 한 도움닫기 마지막 1보와 발구름 국면의 운동학적 분석 (The Kinematic Analysis of the Last Approach Stride and Take-off Phase of BKH Athlete in the High Jump)

  • 윤희중;김태삼;이진택
    • 한국운동역학회지
    • /
    • 제15권3호
    • /
    • pp.105-115
    • /
    • 2005
  • This study was investigated the kinematic factors of the last approach strides and. take off motion for the skill improving of BKH elite male athlete. 'The subjects chosen for the study were BKH and. KASZCZYK Emillian male athletes who were participated in 2003 Dae-Gu Universiad Games. Three high speed video cameras set in 60frames/s setting were used. for recording from the last approach strides to the apex position. After digitizing motion, the Direct Linear Transformation(DLT) technique was employed to obtain 3-D position coordinates, The kinematic factors of the distance, velocity and angle variable were calculated for Kwon3D 3.1. The following conclusions were drawn; 1. It showed longer stride length, as well as faster horizontal and lateral velocity than the success trial during the approach phase. For consistent of the approach rhythm, it appeared that the subject should a short length for obtain the breaking force by the lower COG during the approach phase. 2. The body lean angle showed a small angle by a high COG during the take-off phase. For obtain the vertical displacement of the COG and a enough space form the bar after take-off, it appeared that the subject should increase the body lean angle. 3. For obtain the vertical force during the takeoff phase, it appeared that the subject should keep straight as possible the knee joint. Therefor, the subject can be obtain a enough breaking force at the approach landing.

하악 대구치의 II형 근심 근관에서 치근단 부위의 만곡도 조사 (An evaluation of canal curvature at the apical one third in type II mesial canals of mandibular molars)

  • 윤혜림;이동균;황호길
    • Restorative Dentistry and Endodontics
    • /
    • 제37권2호
    • /
    • pp.104-109
    • /
    • 2012
  • Objectives: The purpose of this study was to evaluate the buccolingual curvature at the apical one third in type II mesial canals of mandibular molars using the radius and angle of curvature. Materials and Methods: Total 100 mandibular molars were selected. Following an endodontic access in the teeth, their distal roots were removed. #15 H- or K-files (Dentsply Maillefer) were inserted into the mesiobuccal and mesiolingual canals of the teeth. Radiographs of the teeth were taken for the proximal view. Among them, type II canals were selected and divided into two subgroups, IIa and IIb. In type IIa, two separate canals merged into one canal before reaching the apex and in type IIb, two separate canals merged into one canal within the apical foramen. The radius and angle of curvature of specimens were examined. Results: In type II, mean radius of curvature in mesiolingual and mesiobuccal canals were 2.82 mm and 3.58 mm, respectively. The radius of the curvature of mesiolingual canals were significantly smaller than that of mesiobuccal canals in type II, and especially in type IIa. However, there were no statistically significant differences in radius of curvature between mesiobuccal and mesiolingual canals in type IIb and there were no significant differences in angle of curvature between type IIa and IIb. Conclusion: In this study, type II mesial canals of mandibular molars showed severe curvature in the proximal view. Especially, mesiolingual canals of type IIa had more abrupt curvature than mesiobuccal canals at the apical one third.

주사탐침현미경용 카본나노튜브 팁의 조립 조건 실험 (An Experiment about Assembling Condition of Carbon Nanotube Tip for AFM)

  • 박준기;한창수
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2004년도 추계학술대회 논문집
    • /
    • pp.501-504
    • /
    • 2004
  • This paper describes the fabrication method for atomic force microscopy(AFM) tip with multi-walled carbon nanotube(MWNT). For making a carbon nanotube (CNT) modified tips, AC electric field which cause the dielectrophoresis was used for alignment and deposition of CNTs in this research. By dropping the MWNT solution and applying an electric field between an AFM tip and an electrode, MWNTs which were dispersed into a diluted solution were directly assembled onto the apex of the AFM tips due to the attraction by the dielectrophoretic force. In this case, we investigate the effect of the angle between a tip axis and an electrode. Experimental setup were presented, and then CNT attached AFM tips are successfully shown in this paper.

  • PDF

폴리머 원형 튜브 대상 미세 패턴 정수압 성형 (Micro Pattern Forming on Polymeric Circular Tubes by Hydrostatic Pressing)

  • 임성한
    • 소성∙가공
    • /
    • 제23권8호
    • /
    • pp.507-512
    • /
    • 2014
  • The objective of the current investigation is to establish techniques in micro pattern forming operations of polymeric circular tubes by using hydrostatic pressing. This method was developed and successfully applied to the micro pattern forming on polymeric plates. The key idea of the new technique is to pressurize multiple vacuum-packed substrate-mold stacks above the glass transition temperature of the polymeric substrates. The new process is thought to be a promising micro-pattern fabrication technique for two reasons; first, (hydro-) isostatic pressing ensures a uniform micro-pattern replicating condition regardless of the substrate area and thickness. Second, multiple curved substrates can be patterned at the same time. With the prototype forming machine for the new process, micro prismatic array patterns, 25um in height and 90 degrees in apex angle, were successfully made on the PMMA circular tubes with diameters of 5~40mm. These results show that this process can be also used in the micro pattern forming process on curved plates such as circular tube.

다소선 Biconical antenna 특성 임피던스 (Study on the characteristic Impedance of Biconical antenna Consisting of 4m conical wires)

  • 박정기;이두수
    • 대한전자공학회논문지
    • /
    • 제11권2호
    • /
    • pp.27-32
    • /
    • 1974
  • 전방향성을 가지는 다소선으로 만들어진 Biconical Antenna의 특성 임피던스식을 해석적으로 구하고, 이식에 의하여 소선수의 변화가 특성 임피던스에 미치는 영향을 고찰하였다. 이 식은 매우 복잡한 형태를하고, 있으나 정각이 40°보다 작다고 하였을 때 얻어지는 근사식은 매우 간단해지며 이것이 바로 Shelkunoff의 식과 일치함을 볼 수 있었다. 그러나 상기 엄밀식과 근사식에 의한 특성 임피던스의 전자계산치를 비교 분석한 결과 항각이 70° 이하인 범위에서는 양자의 차가 별로 크지 않았으므로 정각이 70°보다 작은 범위에서는 상기의 근사식을 적용할 수 있는 것으로 생각한다.

  • PDF

Effect of Reynolds number on compressible convex-corner flows

  • Chung, Kung-Ming;Chang, Po-Hsiung;Chang, Keh-Chin
    • Advances in aircraft and spacecraft science
    • /
    • 제1권4호
    • /
    • pp.443-454
    • /
    • 2014
  • An experimental study was conducted to investigate the effect of Reynolds number on compressible convex-corner flows, which correspond to an upper surface of a deflected flap of an aircraft wing. The flow is naturally developed along a flat plate with two different lengths, resulting in different incoming boundary layer thicknesses or Reynolds numbers. It is found that boundary layer Reynolds number, ranging from $8.04{\times}10^4$ to $1.63{\times}10^5$, has a minor influence on flow expansion and compression near the corner apex in the transonic flow regime, but not for the subsonic expansion flow. For shock-induced separated flow, higher peak pressure fluctuations are observed at smaller Reynolds number, corresponding to the excursion phenomena and the shorter region of shock-induced boundary layer separation. An explicit correlation of separation length with deflection angle is also presented.

A comparative study of several nickel-titanium instruments on canal shaping ability in the simulated canal with abrupt curvature

  • Lim, Jung-Jang;Hwang, In-Nam;Oh, Won-Mann
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2003년도 제120회 추계학술대회 제 5차 한ㆍ일 치과보존학회 공동학술대회
    • /
    • pp.595-595
    • /
    • 2003
  • I. Objectives This study was done to evaluate which type of Ni-Ti instrument be able to perform canal shape well in the simulated canal with abrupt curvature near it's apex. II. Materials and Methods A total of 96 simulated root canals were made in epoxy resin(EPOXICURETM, BUEHLER, USA), #15 finger spreader (MANI, Japan) were used as root canal templates. The simulated root canal were made with radius of curvature of 1.5 mm, 3.0 mm, 4.0 mm, 6.0 mm respectively, and angle of curvature of all simulate camals was 90 degree.(omitted)

  • PDF