• Title/Summary/Keyword: Aperture Size

Search Result 308, Processing Time 0.026 seconds

Program Development to Evaluate Permeability Tensor of Fractured Media Using Borehole Televiewer and BIPS Images and an Assessment of Feasibility of the Program on Field Sites (시추공 텔리뷰어 및 BIPS의 영상자료 해석을 통한 파쇄매질의 투수율텐서 계산 프로그램 개발 및 현장 적용성 평가)

  • 구민호;이동우;원경식
    • The Journal of Engineering Geology
    • /
    • v.9 no.3
    • /
    • pp.187-206
    • /
    • 1999
  • A computer program to numerically predict the permeability tensor of fractured rocks is developed using information on discontinuities which Borehole Televiewer and Borehole Image Processing System (BIPS) provide. It uses orientation and thickness of a large number of discontinuities as input data, and calculates relative values of the 9 elements consisting of the permeability tensor by the formulation based on the EPM model, which regards a fractured rock as a homogeneous, anisotropic porous medium. In order to assess feasibility of the program on field sites, the numerically calculated tensor was obtained using BIPS logs and compared to the results of pumping test conducted in the boreholes of the study area. The degree of horizontal anisotropy and the direction of maximum horizontal permeability are 2.8 and $N77^{\circ}CE$, respectively, determined from the pumping test data, while 3.0 and $N63^{\circ}CE$ from the numerical analysis by the developed program. Disagreement between two analyses, especially for the principal direction of anisotropy, seems to be caused by problems in analyzing the pumping test data, in applicability of the EPM model and the cubic law, and in simplified relationship between the crack size and aperture. Aside from these problems, consideration of hydraulic parameters characterizing roughness of cracks and infilling materials seems to be required to improve feasibility of the proposed program. Three-dimensional assessment of its feasibility on field sites can be accomplished by conducting a series of cross-hole packer tests consisting of an injecting well and a monitoring well at close distance.

  • PDF

The Development of Topographic Feature Extraction Method by use of the Seafloor Curvature Measurement (곡률 계산에 의한 해저면 지형요소 추출 기법 개발)

  • Kim, Hyun-Sub;Jung, Mee-Sook;Park, Cheong-Kee
    • Geophysics and Geophysical Exploration
    • /
    • v.10 no.3
    • /
    • pp.163-172
    • /
    • 2007
  • A seafloor curvature measurement method was developed to extract redundant topographic features from the multi-beam bathymetry data, and then applied to the data of abyssal plain area in the Pacific. Any seafloor might be modeled to a quadratic surface determined in a linear least squares sense, and its curvature could be derived from the eigen values related with quadratic model parameters. The curvature's magnitude as well as polarity showed distinct relationship with geometric characteristics of the seafloor like as ridge and valley. From the investigation of curvature's variation with the number of data in the quadratic surface, the optimal size of data aperture could be applied to real bathymetry data. The application to real data also required the determination of the accompanying threshold values to cope with corresponding topographic features. The calculation method of previous studies were reported to be sensitive to the background noise. The improved curvature measurement method, incorporating the sum of eigen values has reduced unwanted artifacts and enhanced ability to extract lineament features along strike direction. The result of application shows that the curvature measurement method is effective tool for the estimation of a possible mining area in the seamount free abyssal hill area.

High resolution flexible e-paper driven by printed OTFT

  • Hu, Tarng-Shiang;Wang, Yi-Kai;Peng, Yu-Rung;Yang, Tsung-Hua;Chiang, Ko-Yu;Lo, Po-Yuan;Chang, Chih-Hao;Hsu, Hsin-Yun;Chou, Chun-Cheng;Hsieh, Yen-Min;Liu, Chueh-Wen;Hu, Jupiter
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.421-427
    • /
    • 2009
  • We successfully fabricated 4.7-inch organic thin film transistors array with $640{\times}480$ pixels on flexible substrate. All the processes were done by photolithography, spin coating and ink-jet printing. The OTFT-Electrophoretic (EP) pixel structure, based on a top gate OTFT, was fabricated. The mobility, ON/OFF ratio, subthreshold swing and threshold voltage of OTFT on flexible substrate are: 0.01 ^2/V-s, 1.3 V/dec, 10E5 and -3.5 V. After laminated the EP media on OTFT array, a panel of 4.7-inch $640{\times}480$ OTFT-EPD was fabricated. All of process temperature in OTFT-EPD is lower than $150^{\circ}C$. The pixel size in our panel is $150{\mu}m{\times}150{\mu}m$, and the aperture ratio is 50 %. The OTFT channel length and width is 20 um and 200um, respectively. We also used OTFT to drive EP media successfully. The operation voltages that are used on the gate bias are -30 V during the row data selection and the gate bias are 0 V during the row data hold time. The data voltages that are used on the source bias are -20 V, 0 V, and 20 V during display media operation.

  • PDF

Pollen morphology of Patrinieae Höck (Valerianaceae) (마타리족(Patrinieae Höck, 마타리과)의 화분형태학적인 연구)

  • Jung, Eun-Hee;Hong, Suk-Pyo
    • Korean Journal of Plant Taxonomy
    • /
    • v.38 no.2
    • /
    • pp.163-177
    • /
    • 2008
  • Pollen grains of 17 taxa (14 species with two additional subspecies and one variety) of genera Patrinia Juss. and Nardostachys DC. in tribe Patrinieae (Valerianaceae) were studied using light microscope, scanning electron microscope, and transmission electron microscope. Pollen grains are medium ($37.41{\times}43.60{\mu}m$ - $45.65{\times}48.50{\mu}m$) to large ($54.88{\times}59.41{\mu}m$ - $61.70{\times}71.00{\mu}m$) in size, tricolpate (rarely tetracolpate) with the characteristic halo surrounding the aperture. In equatorial view, the pollen is oblate to subprolate, and in polar view, it is mostly circular or rarely 3-lobed. Two major pollen types are recognized on the basis of exine sculpturing patterns; Type I: Exine is composed of echinae together with sparse or dense microechinae, and verrucae shallow or rarely absent (Nardostachys and sections Paleopatrinia, and Monanadropatrinia of Patirinia). - Type II: Exine is composed of massive echinae together with dense microechinae, and prominent verrucae (section Centrotrinia of Patrinia). In TEM sections, columellae are extended from the footlayer into verrucae, and exine thickness is uniform at the pole and equator. Additionally, the infrageneric classification systems of the Patrinieae were evaluated on the basis of the present data.

COLOR DIFFERENCE OF THE DENTAL COMPOSITES MEASURED BY DIFFERENT COLOR MEASURING INSTRUMENTS (복합레진 색상의 측정 기기에 따른 차이)

  • Park, Su-Jung;Noh, Eun-Young;Cho, Hyun-Gu;Hwang, Yun-Chan;Oh, Won-Mann;Hwang, In-Nam
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.3
    • /
    • pp.199-207
    • /
    • 2009
  • The objective of this study was to evaluate the effect of color measuring instrument by measuring the color of dental composite resins. Nine shade light cured composite resin disks were prepared (diameter : 15 mm, thickness : 4 mm). CIE $L^*a^*b^*$ color scale of each disk was measured with 3 different types of spectrophotometer [MiniScan XE plus (Model 4000S, Hunter Lab, USA), CM-3500d (Minolta, Japan) and Specbos 2100 Miniature VIS Reflection spectrometer (Serial No: 319416, JETI Technishe VIS Instrumentic GmbH. Germany)]. Miniscan XE Plus and CM-3500d using identical measuring geometry with different size of viewing aperture. But Specbos 2100 using different measuring geometry. Within the limitation of this study, there were color difference (${\Delta}E^*$) from 2.4 to 7.8 between Miniscan XE Plus and CM-3500d, but $L^*$, $a^*$, $b^*$ values showed the high correlation. However, there were great color difference (${\Delta}E^*$) in the extent of about 20 between instruments with the different measuring geometry. Therefore, color scale measured by color measuring instrument should be used as a relative value rather than an absolute value in the field of dentistry.

Analysis of the Visual Function in low Vision Patients and Normals in Canada, Using Contrast Sensitivity (대비감도를 사용한 캐나나 내 저시력 환자와 정상인의 시기능 분석)

  • Seo, Jae Myung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.3
    • /
    • pp.83-88
    • /
    • 2009
  • Purpose: It is said that persons with low vision (LV) require larger object and longer exposure time to make a visual judgment. The spatial summation stands for the increasing of contrast sensitivity (CS), as the target size is enlarged. Likewise, the term temporal summation is used when the CS increases as the exposure duration is extended. The present study investigates whether or not greater target and longer exposure duration is required for LV subjects than for control subjects. Methods: Twenty subjects with LV and twenty age-matched controls took part in the study. The CS was measured with a 2 alternative forced choice stair case for 0.7 and 3.0 cycle per degree (c/d) static sinusoidal gratings within a circular aperture. The results were analyzed by mixed ANOVA (2${\times}$2). Results: As expected, the CS in the LV group were overall depressed. For spatial summation, mixed ANOVA (2 groups${\times}$2 spatial frequencies) gave p values of 0.13 for the effect of group, 0.14 for spatial frequency and there was no interaction (p=0.59). Similarly, for temporal summation the results were p=0.19 for group, 0.31 for spatial frequency and p=0.95 for interaction. Conclusions: Despite the depression of CS in the LV group, a significant difference for spatial and temporal summation between two subject groups was not reached.

  • PDF

Miniaturized λ/4 Folded Microstrip Antenna for Parking Monitoring Base Station System (주차장관리 시스템 기지국용 소형 λ/4 폴디드 마이크로스트립 안테나)

  • Keum, Jae-Min;Ko, Dong-Ok;Jeong, Jae-Yeop;Woo, Jong-Myung
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.15 no.2
    • /
    • pp.95-101
    • /
    • 2016
  • In this paper, miniaturized ${\lambda}/4$ folded microstrip antennas is presented for parking monitoring base station system. The proposed antenna reduced a width of the radiating element for miniaturizing a size and we changed an aperture such as folded shape for reducing a length of the antenna by the pertubation effect by reducing a width of the antenna. Finally, the ${\lambda}/2$ length of the folded microstrip antenna to ${\lambda}/4$ folded microstrip antenna was miniaturized by reducing the length. The proposed antenna was designed to receive 425 MHz of center frequency that can be used without permission. Dimensions are $134mm{\times}143.85mm{\times}20.1mm$($0.19{\lambda}{\times}0.2{\lambda}{\times}0.028{\lambda}$, ${\lambda}$ is wavelength at 425 MHz) that are compared with basic microstrip patch antenna miniaturized 97.2%. Also, Measured -10 dB bandwidth was 2.44 MHz(0.57%). On the other hand, measured radiation patterns was 1.82 dBi at E-plane $15^{\circ}$.

Verification of Radiation and Beam-Steering Characteristics for Planar-Phased Array Radars Using Near-Field Beam Focusing (근전계 빔 집속 시험 기법을 활용한 평면위상배열레이다 시스템 복사 및 빔 조향 특성 검증)

  • Kim, Young-Wan;Lee, Jaemin;Jung, Chae-Hyun;Park, Jongkuk;Lee, Yuri;Kim, Jong-Phil;Kim, Sunju
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.30 no.2
    • /
    • pp.160-168
    • /
    • 2019
  • In this study, we propose a verification method for a planar-phased array radar system using a near-field beam focusing(NFBF) test method. We then confirmed the validity of the results. The proposed method can be used to verify a radar system in the near-field range of twice the antenna aperture size, and this is done in the same manner as the field system performance test conducted in a non-outdoor electromagnetic anechoic chamber. The test configuration and procedure for verifying the NFBF using near-field energies were reviewed. In addition, the phase compensation values of additional individual channels were quantified through mathematical verification of the beam-steered NFBF test. Based on a theoretical verification, the actual NFBF test was performed and the validity of the test method was confirmed through comparison with ideal analytical results.

Functional beamforming for high-resolution ultrasound imaging in the air with random sparse array transducer (고해상도 공기중 초음파 영상을 위한 기능성 빔형성법 적용)

  • Choon-Su Park
    • The Journal of the Acoustical Society of Korea
    • /
    • v.43 no.3
    • /
    • pp.361-367
    • /
    • 2024
  • Ultrasound in the air is widely used in industry as a measurement technique to prevent abnormalities in the machinery. Recently, the use of airborne ultrasound imaging techniques, which can find the location of abnormalities using an array transducers, is increasing. A beamforming method that uses the phase difference for each sensor is used to visualize the location of the ultrasonic sound source. We exploit a random sparse ultrasonic array and obtain beamforming power distribution on the source in a certain distance away from the array. Conventional beamforming methods inevitably have limited spatial resolution depending on the number of sensors used and the aperture size. A high-resolution ultrasound imaging technique was implemented by applying functional beamforming as a method to overcome the geometric constraints of the array. The functional beamforming method can be expressed as a generalized beam forming method mathematically, and has the advantage of being able to obtain high-resolution imaging by reducing main-lobe width and side lobes. As a result of observation through computer simulation, it was verified that the resolution of the ultrasonic source in the air was successfully increased by functional beamforming using the ultrasonic sparse array.

Compact Orthomode Transducer for Field Experiments of Radar Backscatter at L-band (L-밴드 대역 레이더 후방 산란 측정용 소형 직교 모드 변환기)

  • Hwang, Ji-Hwan;Kwon, Soon-Gu;Joo, Jeong-Myeong;Oh, Yi-Sok
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.7
    • /
    • pp.711-719
    • /
    • 2011
  • A study of miniaturization of an L-band orthomode transducer(OMT) for field experiments of radar backscatter is presented in this paper. The proposed OMT is not required the additional waveguide taper structures to connect with a standard adaptor by the newly designed junction structure which bases on a waveguide taper. Total length of the OMT for L-band is about 1.2 ${\lambda}_o$(310 mm) and it's a size of 60 % of the existing OMTs. And, to increase the matching and isolation performances of each polarization, two conducting posts are inserted. The bandwidth of 420 MHz and the isolation level of about 40 dB are measured in the operating frequency. The L-band scatterometer consisting of the manufactured OMT, a horn-antenna and network analyzer(Agilent 8753E) was used STCT and 2DTST to analysis the measurement accuracy of radar backscatter. The full-polarimetric RCSs of test-target, 55 cm trihedral corner reflector, measured by the calibrated scatterometer have errors of -0.2 dB and 0.25 dB for vv-/hh-polarization, respectively. The effective isolation level is about 35.8 dB in the operating frequency. Then, the horn-antenna used to measure has the length of 300 mm, the aperture size of $450{\times}450\;mm^2$, and HPBWs of $29.5^{\circ}$ and $36.5^{\circ}$ on the principle E-/H-planes.