• Title/Summary/Keyword: Apartments

Search Result 1,235, Processing Time 0.027 seconds

A Study on the Factors Affecting Asbestos Exposure Level from Asbestos Abatement in Building Demolition Sites (석면 해체·제거시 공기 중 노출수준과 영향요인)

  • Kim, Ji-Yeong;Lee, Song-Kwon;Lee, Jeong Hee;Lim, Mu Heok;Kang, Sungwook;Phee, Young Gyu
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.19 no.1
    • /
    • pp.8-15
    • /
    • 2009
  • This study was examined to find out asbestos exposure level the factors which affected the level at asbestos abatement sites. We visited a total of thirteen building demolition sites(3 apartments, 3 schools, 4 stores, and 3 houses) were visited to collect samples and related data from August to November, 2006. The results of this study were as follows 1. The results of an analysis of bulk samples to identify types of asbestos at the asbestos abatement sites showed that the kinds of the asbestos detected were chrysotile by 50.0%, were tremolite by 2.6%, and were the contents of chrysotile by 3 to 20%. 2. The geometric mean concentration of asbestos was 0.007 f/cc(range 0.001-0.34 f/cc) and its geometric standard deviation was 5.83. Of the samples, however, 12 exceeded the Korean Occupational Exposure Limit(0.1f/cc). 3. Of the materials, textile material had the highest concentration with geometric mean of 0.016 f/cc. When asbestos-containing materials were removed using T type tools, the geometric mean concentration of asbestos was 0.061 f/cc. The level by this method was much higher than by other removal methods. In analysis by the type of building, the geometric mean concentration of asbestos in stores was 0.042 f/cc and was higher than in other buildings. 4. The Poisson regression analysis was applied to find out the factors that affect the airborne asbestos concentration. As a result of the analysis, removal using a T type tool was the most important factor affecting the asbestos concentration(p<0.01). In conclusion, the airborne asbestos concentration(geometric mean) in asbestos abatement sites was 0.007 f/cc(0.001~0.34 f/cc), and 12(14.6%) of all samples were over the 0.1 f/cc. These results showed that asbestos abatement workers have been exposed to the high level of airborne asbestos because they have not been keeping asbestos removal rule. In accordance with increases of the number of building demolition sites, the better government regulation on asbestos abatement methods should be made and be performed well at building demolition sites.

An analyses of the noise reduction effect of vegetation noise barrier using scaled model experiments (모형실험을 통한 식생형 방음벽의 소음저감 효과 분석)

  • Haan, Chan-Hoon;Hong, Seong-Shin
    • The Journal of the Acoustical Society of Korea
    • /
    • v.35 no.3
    • /
    • pp.223-233
    • /
    • 2016
  • Design of a vegetation type sound barrier was presented as a noise barrier on the boundary of neighborhood facilities including schools, and apartments. The suggested noise barrier is made of unit blocks that are to be formed by stacking over the wall structure containing the plant and soils in the blocks. The advantage of the vegetation noise barrier is to acquire not only sound absorptive effects of plants and soils, but also sound diffusive effect caused by the irregular surface of the barrier which could eventually mitigate the noise. First, the optimum size of the units to obtain the highest noise reduction was investigated using 1/10 scaled model experiment, and sound attenuation experiments were carried out using a 1/2 mock-up model which is 2 m high and 5 m long. Total 1,137 unit blocks were made of synthetic woods with the size of $10{\times}10{\times}9cm$. These unit blocks were installed on the both side of the 1/2 mock-up steel framed noise barrier. As a result, it was revealed that the block typed vegetation noise barrier has 7 dB higher insertion loss in comparison with the general plane noise barrier. Also, it was found that the appropriate size of unit blocks is $20{\times}20cm$ which has large effect of sound insertion loss.

Analysis of Occupational Accident Types in the Apartment Construction Sites using Multiple Correspondence Analysis (다중 상응 분석을 통한 아파트 건설현장 업무상 재해 유형 분석)

  • Ryu, Han-Guk;Son, Seunghyun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.20 no.3
    • /
    • pp.269-278
    • /
    • 2020
  • In this study, we analyzed the safety accidents that occurred in the apartment construction site and the correlations between the victims according to the type of work accidents through multiple correspondence analysis. There is a lack of disaster-related studies on apartment construction sites, the third most frequent building type in Korea, and most of them have used survey techniques. Therefore, the exploratory data analysis was conducted in industrial accident cause data, and derived the correlation analysis between each disaster victim through multiple correspondence analysis. The results of the study are summarized in two as follows. First, as the number of heights increased due to the high rise and complexity of apartments, the fall rate and mortality rate were high. In addition, deaths are mostly caused by very few experienced workers or those with more than 10 years of experience, resulting from safety training, lack of experience, and insensitivity to safety. Second, multi-correspondence analysis showed that most safety accidents can be prevented by wearing safety equipment, and following proper work process and its safety action. The key factors derived from this study can be used for safety education, supervision, and management in apartment construction sites.

Convergence Research for CIGS Solar Cell Aesthetics Product Design Development for Utilizing Urban Living Structures (도시 생활구조물 활용을 위한 CIGS 태양전지 심미성 향상 제품디자인 개발융합연구)

  • Jo, Jae-Yoon;Jang, Hui-su;Jeong, Je-yoon;Nam, Won-Suk;Jang, Joong-Sik
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.4
    • /
    • pp.157-163
    • /
    • 2020
  • This paper is a product design convergence study to improve the aesthetic quality of CIGS solar cells for utilizing urban living structures, identifying problems of existing solar cell panels and drawing expert aesthetic elements for improving CIGS solar cells through survey and [Group discussion of experts] based on aesthetic elements of product design. Out of the aesthetic elements derived, the top three models of the product design process were 'environmental harmonization', 'pattern balance', and 'period universality' to derive the design and assembly design of the CIGS solar cell module for improving aesthetic quality, and applied to apartments, veranda, windows, and streetcar through product simulation. This study is suitable for applying aesthetic and CIGS solar cell function later to actual urban living structure, and future research direction needs to be studied on various patterns and structural design development of design.

A Study on Strength of Plat-Plate Wall-Column Connections (Wall Column을 적용한 플랫플레이트 접합부 강도발현에 관한 연구)

  • Lee, Do-Bum;Park, Hong-Gun;Lee, Li-Hyung
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.2 s.92
    • /
    • pp.257-266
    • /
    • 2006
  • Flat-plate building systems are utilized extensively for construction of apartments, hotels and office buildings because of short construction period, low floor-to-floor height and flexibility in plan design. Recently, to increase lateral seismic resistance of flat-plate building systems, wall-columns are used frequently. Therefore, to estimate strength of flat-plate column connection accurately, the effect of column section shape on the behavior of flat-plate column connection should be considered properly, In the present study, a numerical analysis was performed for interior connections of continuous flat-plate to analyze the effect of column section shape. For the purpose, a computer program for nonlinear FE analysis was developed, and the validity was verified. Through the parametric study, the variations of shear stress distribution around the connection were investigated. According to the result of numerical analysis, as the length of the cross section of column in the direction of lateral load increases, the effective area and the maximum shear strength providing the torsional resistance decrease considerably. Therefore, these effects should be considered properly to estimate the strength of flat-plate connection accurately.

Shear Strength Reduction Ratio of Reinforced Concrete Shear Walls with Openings (개구부를 갖는 철근콘크리트 전단벽의 전단강도 저감률)

  • Bae, Baek-Il;Choi, Yun-Cheul;Choi, Chang-Sik;Choi, Hyun-Ki
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.4
    • /
    • pp.451-460
    • /
    • 2010
  • There are many types of remodeling, however, engineers and architectures preferred to merge two or more separate units to one very spacious unit. Performing this type of remodeling, in the case of wall dominant apartments, requires partial removal of structural wall causing a concern of structural integrity. However, there are insufficient studies about partial removal, that is, openings. Presently, ACI standard have no clear way to evaluate the effect of opening on the structural wall. AIJ has the provision about strength reduction factor '$\gamma$'. However, this reduction factor cannot exactly evaluate the reduction effect of openings because this factor '$\gamma$' was determined through the elastic analysis. Therefore, in this study, 2 structural wall specimens were tested and many test results from previous studies were collected. Using these data, this study performed statistical analysis about strength of structural wall which have the opening in wall panel. And this study performed parametric study verifying shear strength reducing effect by opening area. In the results of statistical study, previous reduction factor show very conservative results because this equation did not consider other factors, reinforcement ratio and aspect ratio of openings, which was affect the shear strength of shear walls. Therefore we performed parametric study based on the test data and suggest new equation for shear strength reduction factor '$\gamma$'.

A Study on Developing A Design of Package Air Conitioner For Home use-With a Focus on Goldstar Co Package Air conditioner (가정용 PACKAGE AIR CONDITIONER 디자인 개발에 관한 연구-(주) 금성사 PAC를 중심으로-)

  • 오성진
    • Archives of design research
    • /
    • v.13
    • /
    • pp.153-162
    • /
    • 1996
  • The residence space has been in the trend of being expanded with the J'l'cent economic growth Therefore PAC may be said to have [wen from business use to home US(: the progressed living standard as the goods ior Uw "ummel' S('dSOn rest'ntly though sold in Uw fast for mainly buslTw"s use. PAC has been in the demand day ;lner day and in the tn'nd on the bc,ing the necessJty of the n'sent wf',lther warming phenomenon This study is the case study nf the products development and design process of PAC which has bpcn llrivcn and developed by Gold Star Co. ,Ltd. Which .is the firm for home electric appliances representing Korea. This studies for the development and the design of the products by the firm thus emphasizing the visulizing it based on this study. For example as they being the goods for the summer season I have tried to know the physical quakity and the characters of koreans by the weather conditions and estimated the demand by setting up the target customers of the PAC as the customers' environment. And I analyzed the acts in the living room in the apartments as the living envinorment which has the direct relation with PAC and also became a help to the moulding work of PAC by analyzing the complete interior image in the living room. In the practical moulding work the Design concept was classified into the envinorment of customer, living and products to drive as the below. Firstly - New shape (Round slim) has been realized which leads the minimizing the moulding space and visul sense of opening as its being spacious. The 2nd - the high class sense of the products which are harmonious with the atmosphere of the living room by making it interiorized has been visible. The 3rd - The shape stimulating the sensitivity of the users and surface treatment are emphasized by making it be touched. The 4th - During inviting use of technology image which appears in the electronics products are attemptedby making it be high quality.king it be high quality.

  • PDF

Evaluation of the Magnetic Field Exposure Level in 60 Hz High Voltage Transmission Lines Nearby Residential Area (60 Hz 고압송전선로 인접 주거지역의 자기장 노출수준 평가)

  • Hong, Seung-Cheol;Jung, Joon-Sig;Kim, Keun-Young;Park, Hyun-Ju;Choi, Sung-Ho
    • Journal of Environmental Health Sciences
    • /
    • v.34 no.1
    • /
    • pp.27-33
    • /
    • 2008
  • In order to evaluate the magnetic field (MF) exposure level in residential areas near high voltage power lines, this research measured MF levels at 120 sites near high voltage transmission lines in the Busan region, Gwangju region, Daegu region and Changwon region from July to December, 2005, and compared and analyzed the efficiencies by measuring and applying the MF emission levels of underground cables and high voltage transmission lines. As a result of the investigation of the MF exposure level by the building usage, the average MF level of 17 locations at schools was $2.44{\pm}2.45mG;$ that of 10 locations at hospitals $6.21{\pm}12.39mG;$that of 76 locations at apartments $2.55{\pm}2.98mG;$ and that at kindergartens and infant houses $3.32{\pm}4.21mG$. MF exposure was analysed as a function of distance from the source and the MF levels directly below a source were $5.15{\pm}8.72mG$, those within 30 m were $3.10{\pm}3.32mG$, while those within 50 m were $2.45{\pm}2.38mG$, and within 100 m were $0.71{\pm}0.93mG$. In order to determine the difference of MF levels by the actual distance from high voltage transmission line within the same building, the evaluation of the floor position and the MF level has shown that the MF levels were highest in the order of roof, 4th floor, 3rd floor, 2nd floor and 1st floor. Comparison of MF emission intensity of underground cables and high voltage transmission lines, has shown that underground cables have an 86-94% of reduction ratio in MF compared to high voltage transmission lines, thus demonstrating higher efficiency.

A Comparative Study of Economical Efficiency in Apartment Security System: Focused on a Enhancing the Effectiveness of Senior Employment Programs (아파트 유·무인 경비시스템의 경제성 비교 연구: 노인일자리 사업의 효용성 제고를 중심으로)

  • Ha, Jai-Ryong;Lee, Kwang-Won
    • Korean Security Journal
    • /
    • no.41
    • /
    • pp.7-36
    • /
    • 2014
  • Recently the Korean government announced that minimum wage policy would be applied even to apartment security staffs by 2015 who had been waived from the policy enforcement for their unique work conditions. This caused apartment management to introduce unmanned security system instead of employing security staffs because of fearing possible hike of management fees. People recklessly tend to believe unmaned system is cheaper than maned system if minimum wage guideline is applied. This study examines the economic feasibility of two different apartment security systems by utilizing cost-benefit analysis: maned and unmaned security systems. The authors estimate the costs and the benefits of each security system for 5 years(2014-2018) with application of social discount rate(5.5%). Thirty six apartment complexes at 8 different areas(meons and dongs) in Asan, Chungcheongnam-do province were surveyed. And to attain the exact costs of unmaned system establishment and operation, the authors interviewed persons working for the unmaned security corporations. The benefit-cost(B/C) ratio for unmanned security system is 1.66% at minimum and 1.30% at maximum. while B/C ratio for manned security system is 1.42% and 1.66% respectively. This results mean that people's belief is not correct, that is, transferring from maned system to unmaned is not always economically efficient. Benefits of maned security system is more diverse than unmaned system. The former provides living conveniences(parking helps and keeping parcels) and social benefits(employing aged worker and giving them opportunities to enjoy happier lives) as well as security benefits like crime prevention. The latter provides security benefits only, but that effect is also doubtable. Taking into account these diverse benefits maned system provides, the B/C ratio of maned system is equitable or higher than unmaned system.

  • PDF

Wave Propagation Characteristics for Mobile Communications beyond 3G in Microcellular Environments (마이크로셀룰라 환경에서의 차세대 이등 통신을 위한 전파 전파 특성)

  • Jo Han-Shin;Yook Jong-Gwan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.5 s.108
    • /
    • pp.430-439
    • /
    • 2006
  • This paper presents the a measured path-loss characteristics for mobile communications beyond 3G in microcellular residential area and street microcell at 3.4, 5.3, and 6.4 GHz band signals. The residential area is divided into two sections, one of which is composed of fifteen-story appartment buildings. The other section comprises four-story houses. The street microcell is classified line-of-sight(LOS) and nonline-of-sight(NLOS) areas. Both residential areas have standard deviations independent of the residential area classification, whereas the path loss exponents in the apartments is higher than those in area for same frequencies. A two-ray model is applied to analyse the path-loss charateristics in LOS areas. In LOS areas, an empirical breakpoint, whose distance is 6 percent shorter than a theorical breakpoint, is founded. Further, a sudden power level drop occurs at a transition point from LOS region to NLOS area. Path loss exponent is found to be significantly higher for non-LOS region than for LOS region. The power level drop due to corner loss and path-loss exponents both increase as the distance between the transmitter and the corner increases.