• 제목/요약/키워드: Apartment noise

검색결과 364건 처리시간 0.021초

도심지 발파공사장의 발파진동 특성 (The Characteristics of Blasting Vibration in the Construction of Apartment and Buildings in Urban Area)

  • 이연수;장서일
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 춘계학술대회논문집
    • /
    • pp.521-526
    • /
    • 2004
  • In order to evaluate the effect of blasting vibration in buildings and it's resident located around blasting construction field in urban area, blasting vibration characteristics were measured the vibration level, vibration velocity. The 250g and 750g of charged powder were used at the apartment and at the ground, respectively. In the measurement of the ground, Z(perpendicularity) axis was the highest value in vibration level, but vertical axis was the highest value at 25m point and longitudinal axis was the highest value at 50m point in vibration velocity. The amount of measurement was high value when measuring point is higher than blasting source, while that of measurement was low value when measuring point is lower than blasting source. In the measurement of the apartment, 2 axis was the highest value in vibration level, but in vibration velocity transverse axis was the highest value at ground, was vertical axis at 1st floor, was longitudinal axis at 3rd floor and was vertical and longitudinal axis at 5th floor. The vibration level and the vibration velocity of 50m point showed higher correlation value than 25m point at the ground, but those of 25m point showed higher correlation value than 50m point at the apartment.

  • PDF

도심지 발파공사장의 발파진동 특성 (The Characteristics of Blasting Vibration in the Construction of Apartment and Buildings in Urban Area)

  • 장서일;이연수
    • 한국소음진동공학회논문집
    • /
    • 제14권7호
    • /
    • pp.632-638
    • /
    • 2004
  • In order to evaluate the effect of blasting vibration in buildings and it's resident located around blasting construction field in urban area, blasting vibration characteristics were measured by the vibration level, vibration velocity. The 250g and 750g of charged powder were used at the apartment and at the ground, respectively. In the measurement of the ground, 2 (perpendicularity) axis was the highest value in vibration level, but vertical direction was the highest value at 25 m point and longitudinal direction was the highest value at 50 m point in vibration velocity. The amount of measurement was high value when measuring point is higher than blasting source, while that of measurement was low value when measuring point is lower than blasting source. In the measurement of the apartment, Z axis was the highest value in vibration level, but in vibration velocity transverse direction was the highest value at ground, was vertical direction at 1st floor, was longitudinal direction at 3rd floor and was vertical and longitudinal direction at 5th floor. The vibration level and the vibration velocity of 50 m point showed higher correlation value than 25 m point at the ground, but those of 25 m point showed higher correlation value than 50 m point at the apartment.

설문조사를 통한 노후 공동주택의 설비 리모델링 의식조사 (A Residents' Mechanical Equipment Remodeling Preferences Study on the Aged Apartment Housing by Questioning Survey)

  • 김지현;유선용;이상엽;정차수;김태연;이승복
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.1061-1068
    • /
    • 2006
  • This study has been conducted to provide the basic datum to draw mechanical equipments needed for aged apartment housing remodeling by questioning survey and interview for residents who has been lived in the aged apartment housing. To preferences survey, we prepare four forms of sheets - questioning survey and interview for residents, interview for managers, and visiting interview for residents. The questioning survey results shows that some residents feel discomfort for water hammer and water supply noise and for noise and stink transmission from air duct installed ceiling to ventilate bathroom. The interview results for residents and managers shows typically two major problems. The first is insulation and heating problems when balcony extended in each household. The second is piping and shaft layouts problem for maintenance and remodeling flexibility. It is important to study indepth each problems because these problems will increase more in the future.

  • PDF

도심지 내 복층 저소음포장 설치에 따른 소음저감 사례연구 (A Case Study on Noise Reduction Effect of Two-layer Porous Asphalt Pavement in an Urban Area)

  • 정종석;소정락;이수형;양홍석
    • 한국도로학회논문집
    • /
    • 제18권5호
    • /
    • pp.49-56
    • /
    • 2016
  • PURPOSES : In this study, noise reduction effect of a two-layer porous asphalt pavement was investigated through site measurement and computer simulation. METHODS : To examine noise reduction effect, a 3 km long quiet pavement was installed by removing previous normal pavement, which had a rather low porosity. The studied site was a high-rise apartment building surrounded by the quiet pavement and Seoul ring road with heavy traffic volume, indicating relatively high background noise. RESULTS : The measurement result before and after installing the quiet pavement showed a noise reduction effect of 4.3 dB(A) at a distance of 7.5 m from the road. After validating the accuracy of simulation using SoundPLAN, the reduction in SPL(sound pressure level) at the facades by the quiet pavement was predicted by considering five different road conditions generating traffic noise from each road or in the combination of the quiet pavement and Seoul ring road. In the case of no noise from Seoul ring road, noise reduction at the facades was 4.2 dB(A) on average for 702 housing units. With background noise from Seoul ring road, however, the average SPL decreased to 2.0 dB(A). Regarding subjective response of noise, the number of housing units with a noise reduction of over 3 dB(A) was 229 out of 706 units (approximately 32%). For 77 housing units, the noise reduction was between 1~3 dB(A), while it was less than 1 dB(A) for 400 housing units. CONCLUSIONS : The overall result indicates that the quiet pavement is useful to reduce noise evenly at low and high floors compared to noise barriers, especially in the urban situation where background noise is low.

완충재 적용에 따른 습식온돌의 구조안전성 평가를 위한 실험연구 (An Experimental Study on Structural Safety Assesment of Wet Type Floor Heating System with Insulation)

  • 안재원;전명훈;이범식;이도헌
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.287-290
    • /
    • 2005
  • Housing is demanded to convert simple dwelling space into delightful one by improving of standard of living by economic development It is interested in the impact noise of the apartment housing that is revised to housing construction criteria at 29 March 2005 and then regulated the level of floor impact noise by the rule. The plan, which is actively investigated by counterplan for the reduction of impact noise, is application of sound insulation. In generally, first target by using insulation is the reduction of floor thermal transmittance in floor heating system of apartment housing. It is recently proposed soft materials that reduce the impact noise. However, it is a fact that the application of soft sound insulation includes some problem about structural performance. In this study, we made wet-heating specimen with various sound insulations, and carried out structralexperiment for evaluating the structural safety of it.

  • PDF

바닥충격음 저감이 가능한 천장 공법 개발 (Development of ceiling construction methods reduced floor impact sound)

  • 김경호;김성훈;류종관;이종인;김용민
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.203-207
    • /
    • 2014
  • According to the advanced study, Increase of ceiling air space could cause increase of floor impact sound by air-spring effect. So in this research, we studied the increase of floor impact sound caused by ceiling air space in apartment buildings. At first, we evaluated the change of floor impact noise in the condition of with or without ceiling air-space. And then we installed perforated ceiling systems and glass wool at ceiling area. we expected that perforated ceiling systems could prevent air-spring effect in ceiling space. As a result, ceiling air space caused increasement of floor heavy impact noise about 2~4dB. But perforated ceiling & sound-absorbing materials system could give us reduction of heavy floor impact noise about 3dB. So this systems could be a good alternative to obey national regulations, because it can reduce heavy impact noise additional to floating floor systems.

  • PDF

공동주택의 현관문 차음성능 개선을 위한 연구 (Improvement of Sound Transmission Class in the Front Door of Apartment)

  • 이병권;배상환;홍천화;송만수;정문호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.93-96
    • /
    • 2004
  • In the case of the front door of the apartment, which functions as an entrance, the study about noise has been less active than corridor type plane in the past, since stair room type plane was generalized. Hence, this study shows the survey about residents' thoughts of noise transmission through the front door, and after researching sound insulation of the present apartments, we figured out what the problem is. Moreover, we did an efficiency test as developing the front door, which increases sound insulation. As a result, it turned out that residents think that the noise transmission through the front door is as serious as floor impact noise, and also, the efficiency of the front door is as poor as STC 22-30. Therefore, in the developed front door, we should improve the efficiency to the level of STCSS. It will be a good way preparing for a demand of residents.

  • PDF

소비자가 인식하는 아파트 구매가격결정요인과 쾌적성 결정요인과의 순위적 관계분석 (An Analysis of Rank Correlation between the Apartment Purchase Price Decision Factor and Amenity decision Factor with cognition of the Consumer.)

  • 김형돈
    • 한국주거학회논문집
    • /
    • 제12권2호
    • /
    • pp.45-54
    • /
    • 2001
  • The purpose of this research was to analyze the correlation between the Apartment Purchase Price Decision Factor and Amenity decision Factor with cognition of the Consumer. The result are as follows; 1. The correlation coefficient between the Apartment Price Decision Factor and Amenity decision Factor with cognition of the Consumer was 0.587. 2. The ranking of the purchase price factor which it prefers were analyzed orientation > sunlight > view > the rising price expectation > natural environment etc. And the ranking of the amenity were analyzed orientation > natural environment > view > sunlight > noise etc. 3. Consumer group was classified the location, sex, year of ages and unit scale. The rank correlation coefficient of (the significant was below 0.05) sex was 0.617~0.644, year of ages was 0.62~0.771 and unit scale was 0.762~0.852. This research proved the fact that the amenity correlated with the apartment purchase price decision factor, so amenity contained an economic value. And this result will be used in decision-making-process of apartment construction.

  • PDF

초고층 공동주택의 평수와 층수에 따른 바닥충격음 차음 특성 (Impact Sound Insulation Characteristics of Floors according to the number of P'yong and Layers)

  • 이상우
    • KIEAE Journal
    • /
    • 제4권3호
    • /
    • pp.71-78
    • /
    • 2004
  • Apartment housing is a widely-spread type in Korean housing market. Nevertheless, it has caused serious problems such as traditional community corruption, unsafe structure, defects and litigation from noise. Noise, especially in concrete structure for apartment housing, is hardly controlled in proper to prevent sound transmission between upper and lower families with existing system. In foreign countries, there are floating floor system to enhance the noise control performance in multi-family housing. This study is to examine the impact sound insulation performance of floors according to the different P'yong and Layers by field measurement in highrise building.

수음실 내 구조체의 진동량 계측을 통한 바닥충격음레벨 예측 (Prediction of Floor Impact Sound by Measuring the Vibration Acceleration Level on the Interior Structures of Receiving Room in Apartment Buildings)

  • 김명준;김흥식;김하근
    • 한국소음진동공학회논문집
    • /
    • 제13권1호
    • /
    • pp.3-9
    • /
    • 2003
  • In an apartment building, the impact sound from upstairs has been regarded as a main source of noise causing discontentment among occupants. To set the optimum design for sound insulation. it is nesessary to suggest the useful tools or technique that predict the floor impact sound. The purpose of this study is to investigate the applicability of the theory of sound radiation. We measured the vibration acceleration levels on the interior structures and predicted the sound pressure level of the room by using them. The result show that the predicted value, in general, were in good agreement with the measured values within 5∼10% in error rate.