• Title/Summary/Keyword: Apartment fire

Search Result 197, Processing Time 0.033 seconds

A Study on the Effective Method of Fire Extinguisher Maintenance In the Underground Parking Lot of the Apartment (아파트 지하주차장 소화기의 유지관리 효율화 방안에 관한 연구)

  • Lee, Young-Sam
    • Journal of the Korea Safety Management & Science
    • /
    • v.18 no.3
    • /
    • pp.1-8
    • /
    • 2016
  • The definition of an apartment is a building more than 5 stories high and which is the standard law. Currently, the number of apartments is increasing much faster than detached houses. Owning an apartment is a normal trend these days. However, the increasing number of apartments has been increasing the number of apartment fires which also has been making social problems. Therefore, this study was conducted for the fire extinguisher among other fire facilities because it is important for initial fire suppression. The research subject is on the fire extinguisher that is in the underground parking lot of 40 apartment complexes which are more than 10 stories. Survey and analysis were conducted for 80 fire extinguishers. There are two fire extinguishers for each apartment. The result of this study is that all installed fire extinguishers are ABC dry chemical type, 92% of them is 3.3kg and that meet the legal height(less than 1.5m). However, the condition such as appearance, inspection, manufactured year, appearance of signs, material of signs, size of signs, etc. was insufficiency. So improvement of law and system that are fire facility construction, maintenance implementation and additional designation of type approval about sign will be needed in my opinion.

A Full-scale Fire Test of an Apartment House (공동주택 실물화재 실험)

  • Kim, Myung-Bae;Han, Yong-Shik;Choi, Byung-Il;Do, Kyu-Hyung
    • Fire Science and Engineering
    • /
    • v.23 no.4
    • /
    • pp.104-111
    • /
    • 2009
  • To research about the fire spread in Korean apartment house, a full-scale fire test in a four-story apartment was executed. The fire started at the third floor, and originated from overheated cooking oil in the kitchen. The apartment included all combustibles in general house. Through measuring temperature, measuring the concentration of oxygen and observing, we investigated the fire spread inside the apartment house. As a result, we got the data of the time needed for the initiation of fire, the time for fire to spread into each area in the house, and the time required until flash-over was seen. Also we grasped the understanding of the fire spread to the upper floor.

A Study on the Fire Safety Design of High-Rise Apartment Buildings (초고층아파트의 화재안전성에 관한 건축계획적 연구)

  • 서동갑;장순익;이명호
    • Fire Science and Engineering
    • /
    • v.5 no.3
    • /
    • pp.23-30
    • /
    • 1991
  • One of the most serious national problems is the shortage of houses, especially in great cities. Housing shortage resulted from an overpopulated city brought the high-rise apartment buildings. While these buildings provide city-dwellers with much more houses, they have the basic fire safety problem in proportion to their heights. In these respect, this study aims to present the basic data for the fire safety design of high-rise apartment buildings. In this study, national fire damage statistics of past eleven years were investigated and the problem of the fire safety design of high-rise apartment buildings was studied through the methods of questions, observations and records on the representative six high-rise apartment buildings in seoul.

  • PDF

A Case study on the Escape Performance of Apartment Buildings (사례를 통한 공동주택의 피난성능에 관한 연구)

  • 이용재;이범재
    • Fire Science and Engineering
    • /
    • v.12 no.4
    • /
    • pp.59-69
    • /
    • 1998
  • As high-rise Apartment buildings increase the importance of fire prevention and escape performance. While these buildings provide dwellers with much more houses, they have the basic escape safety problem in their apartment buildings. In these respect, this study aims to present the Principles of Fire protection for the escape performance of apartment buildings. This study reviews basic theories of escape in apartment buildings. I figure out the characteristics of the fires in apartment buildings by case studying the fire in the apartment buildings, and find out the existing problems for escape performance and fire prevention by surveying. In this study, the major findings are as follows: The planning method should be based on the escape performance. In the planning stage, fire safety should be considered more seriously than law and economic factors.

  • PDF

A Study on the Fire Safety Design of High-Rise Apartment Housing in Korea (초고층 아파트의 화재안전계획에 관한 연구)

  • 최인석;박윤성
    • Fire Science and Engineering
    • /
    • v.5 no.1
    • /
    • pp.15-22
    • /
    • 1991
  • After the appearance of apartments in Korea, Apartment Housing has been generally accepted for its high capacity of population and convenience in the management. Nowadays, apartments have become higher, larger and more complex than ever before, showing abrupt changes in structure, form and mechanical systems. Likewise, the hazards of fire and the scale of fire losses have become a serious problem. Therefore. considerations of fire safety have taken a greater portion in the design of Apartment Housing. This study is focused particulary on spatial planning rather than on mechanical systems for fire safety.

  • PDF

공동주택 소방설계원칙 및 발전방향에 관한 연구

  • 서덕석;윤명오
    • Fire Science and Engineering
    • /
    • v.8 no.2
    • /
    • pp.16-26
    • /
    • 1994
  • This Research developes the principles in apartment fire safty planning, suitable to the fire characteristics of apartment. On the base of the principles, alternative proposals are suggested to unreasonable provisions in Fire Protection Codes.

  • PDF

Statistical Analysis on the Structure of the Front Door in Apartment House (공동주택 세대 현관 방화문 구조에 관한 통계적 분석)

  • Shim, Han-Young;Park, Won-Jun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.23-24
    • /
    • 2021
  • Since 2011, apartment houses account for about 41% of the fires in residential facilities for the past 10 years. Fire-resistant performance of fire doors is becoming more important to prevent the spread of fire in apartment houses. This research analyzed the structure of fire door through each 10 DB based on the quality inspection report of Continuous Acquisition & Life-cycle Support(CALS) from 2016 to 2020, which passed the fire performance test based on the laws and notices of domestic fire door. Therefore, based on the results of the analysis of DB in the future, we will conduct a study on structural improvement and addition for fireproof performance improvement of fire door.

  • PDF

A Study for Performance Improvement of Fire Detector and Sprinkler Head in Apartment Houses (공동주택 화재감지 및 소화성능개선에 관한 연구)

  • Lee, Chae-Won;Son, Bong-Sei
    • Fire Science and Engineering
    • /
    • v.29 no.1
    • /
    • pp.38-44
    • /
    • 2015
  • This study suggested the problems and their improvement measures for the operation of fire detectors and sprinkler heads installed at apartment houses. According to a census on population and housing in 2010, apartment houses account for 71.6% of the total housing facilities. And by fire statistics data of the National Emergency Management Agency, approximately 25.0% of fire accidents and 46.4% of casualties occur at apartment houses every year. Therefore, this study conducted for identifying the causes and characteristics of fire to establish the fire safety improvement measures for apartment houses. And this study was carried out virtual fire simulation at domestic apartment houses. The scenario of the simulation contains a comparative analysis on the operation time of standard sprinkler heads and residential sprinkler heads, heat detectors and smoke detectors. As a result of simulation, it was found that standard sprinkler heads and heat detectors installed at the existing apartment houses should be replaced with residential sprinkler heads and smoke detectors for rapid fire suppression. In addition, sprinkler systems should be considered to be installed for excluded floor at apartment houses. Especially, it is necessary to construct remote inspect systems like advanced countries for efficiency of apartment houses safety management.

Basic Study for performance Improvement of Fire Detectors System at Domestic Apartment Buildings (국내 공동주택 화재감지시스템의 성능개선을 위한 기초연구)

  • Son, Bong-Sae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.1
    • /
    • pp.533-538
    • /
    • 2014
  • This study examines the performance of and searches for improvements to the existing automatic fire detection systems installed at domestic apartment buildings as a basic study for development of intelligent fire detection systems specifically for apartments. Thus, this study aims to find out the problems in performance and maintenance of the existing fire detectors installed at apartment buildings which is the prerequisite process for development of intelligent fire detection system for that specific application. It is also found impossible to check whether or not the detectors installed at each apartment are in an operational state at normal times. This study finds that it is desirable to replace the slow-sensing heat detectors by a smoke and single smoke detectors which can detect a fire at its early stage in an effort to improve the problems of fire detectors installed at apartment buildings presently. Because we need to the independence fire detection system of apartment building.

Study of the Fire Risk of Occupants During Pilotis Space Fires (필로티 공간의 화재 시 재실자의 위험성에 관한 연구)

  • Choi, Seung-Bok;Choi, Doo-Chan;Choi, Don-Mook
    • Fire Science and Engineering
    • /
    • v.30 no.5
    • /
    • pp.144-150
    • /
    • 2016
  • An apartment house with a pilotis that raises the architectural volume and provides a space for circulation is becoming popular. With the popularity of pilotis in apartment houses, people also have a keen interest in the potential fire risk at the pilotis. As residents can only access their apartment house through the pilotis, there is a risk to the occupants if there is fire there. Therefore, this study evaluated the pilotis fire cases of urban multifamily housing to conduct a Fire Dynamics Simulator (FDS) and Fire Evacuation Simulation (FES). Through these two simulation methods, it is possible to validate the riskiness of fire at an apartment with a pilotis. The study identified that the toxic gases and flame spread out to the pilotis within hundred seconds after ignition. In addition, the toxic gases and flame also reach the second floor within three seconds and the entire building within 735 seconds if the entrance doors at the pilotis are opened. On the other hand, the FES simulation results showed that it also takes about approximately 609 seconds to excavate from the apartment house with a pilotis. Therefore, this research shows that an apartment house with a pilotis can ensure the building occupants' lives and their safety if there is fire.