• Title/Summary/Keyword: Aortic valve surgery

Search Result 576, Processing Time 0.026 seconds

Left Coronary Ostial Obstruction by a Dislocated Sutureless Aortic Valve Prosthesis: Redo Aortic Valve Replacement with Hybrid Coronary Revascularization: A Case Report

  • Seungmo Yoo;Hong Rae Kim;Jae Suk Yoo
    • Journal of Chest Surgery
    • /
    • v.56 no.5
    • /
    • pp.359-361
    • /
    • 2023
  • Coronary ostium obstruction due to dislodgement of the prosthetic valve is a rare and life-threatening complication, and particular caution is required for sutureless aortic valve replacement (AVR) with concomitant valvular surgery. In general, coronary artery bypass surgery is performed when coronary ostium obstruction occurs after AVR, but other options may need to be considered in some cases. Herein, we present a case of coronary artery occlusion in an 82-year-old female patient who had undergone AVR and mitral valve replacement for aortic valve stenosis and mitral valve stenosis at the age of 77 years. A hybrid procedure involving redo AVR and percutaneous coronary intervention after left main coronary ostium endarterectomy was performed. To summarize, we present a case of hybrid AVR in a patient with coronary artery obstruction after AVR that was successfully managed using this method.

Right anterior mini-thoracotomy aortic valve replacement versus transcatheter aortic valve implantation in octogenarians: a single-center retrospective study

  • Ji Eun Im;Eun Yeung Jung;Seok Soo Lee;Ho-Ki Min
    • Journal of Yeungnam Medical Science
    • /
    • v.41 no.2
    • /
    • pp.96-102
    • /
    • 2024
  • Background: The aim of this study was to compare the early outcomes of octogenarians undergoing minimally invasive right anterior mini-thoracotomy aortic valve replacement (RAT-AVR) with those undergoing transcatheter aortic valve implantation (TAVI) for aortic valve disease. Methods: In this single-center retrospective study, data were collected from octogenarians before and after RAT-AVR and TAVI between January 2021 and July 2022. Short-term outcomes, including the length of hospital stay, in-hospital mortality, all-cause mortality, and other major postoperative complications, were compared and analyzed. Results: There were no significant differences in in-hospital mortality, stroke, acute kidney dysfunction requiring renal replacement therapy, length of intensive care unit stay, or length of hospital stay. However, the TAVI group had a higher incidence of permanent pacemaker insertion (10% vs. 0%, p=0.54) and paravalvular leaks (75% vs. 0%, p<0.001). Conclusion: In the present study on octogenarians, both TAVI and RAT-AVR showed comparable short-term results. Although both procedures were considered safe and effective in the selected group, RAT-AVR had a lower incidence of complete atrioventricular block and paravalvular regurgitation.

Aortic Valve Replacement for Aortic Stenosis in Elderly Patients (75 Years or Older)

  • Sohn, Bongyeon;Choi, Jae Woong;Hwang, Ho Young;Kim, Kyung Hwan;Kim, Ki-Bong
    • Journal of Chest Surgery
    • /
    • v.51 no.5
    • /
    • pp.322-327
    • /
    • 2018
  • Background: This study evaluated the early and long-term outcomes of surgical aortic valve replacement (AVR) in elderly patients in the era of transcatheter aortic valve implantation. Methods: Between 2001 and 2018, 94 patients aged ${\geq}75years$ underwent isolated AVR with stented bioprosthetic valves for aortic valve stenosis (AS). The main etiologies of AS were degenerative (n=63) and bicuspid (n=21). The median follow-up duration was 40.7 months (range, 0.6-174 months). Results: Operative mortality occurred in 2 patients (2.1%) and paravalvular leak occurred in 1 patient. No patients required permanent pacemaker insertion after surgery. Late death occurred in 11 patients. The overall survival rates at 5 and 10 years were 87.2% and 65.1%, respectively. The rates of freedom from valve-related events at 5 and 10 years were 94.5% and 88.6%, respectively. The Society of Thoracic Surgeons (STS) score (p=0.013) and chronic kidney disease (p=0.030) were significant factors affecting long-term survival. The minimal p-value approach demonstrated that an STS score of 3.5% was the most suitable cut-off value for predicting long-term survival. Conclusion: Surgical AVR for elderly AS patients may be feasible in terms of early mortality and postoperative complications, particularly paravalvular leak and permanent pacemaker insertion. The STS score and chronic kidney disease were associated with long-term outcomes after AVR in the elderly.

Aortic Root Replacement with Pulmonary Autograft in Patient with Subaortic Abscess and False Aneurysm in Left Ventricular Outflow Tract -Report of A Case- (동맥근 농양 및 좌심실유출호 가성 심실류 환자에서 폐동맥 자가이식편을 이용한 대동맥근부치환술 -1례 치험 보고-)

  • 장병철
    • Journal of Chest Surgery
    • /
    • v.28 no.7
    • /
    • pp.704-707
    • /
    • 1995
  • The use of the patient`s pulmonary valve for replacement of the patient`s diseased aortic valve was introduced and developed by Mr. Donald Ross. The long term benefits of having a normal, fully viable, trileaflet semilunar valve in aortic position was demonstrated. A 38 year old male had histories of failures of previously implanted aortic prosthetic valves twice and evidence of progressive heart failure. At operation, aortic root abscess was found; the abscess extension to adjacent structures and partial valve dehiscence had occurred. The patient underwent replacement of the aortic root with autologous pulmonary valve, autologous pericardial patch repair of left ventricuar outflow tract and recontruction of the right ventricular outflow tract and pulmonary artery with prosthetic valved conduit. Postoperatively, the patient recovered well. Postoperative doppler echocardiography demonstrated minimal central regurgitation in new aortic valve. Aortic root replacement with pulmonary autograft in a patient of recurrent aortic root abscess and false aneurysm of left ventricuar outflow tract was experienced and reported with follow up echocardiography.

  • PDF

Infective Endocarditis of Aortic Valve and Tricuspid Valve Associated with a Fistula between Aorta and Right Ventricle - One Case Report - (대동맥과 우심실사이의 누루를 동반한 대동맥판막 및 삼첨판막의 감염성 심내막염 치험 1례)

  • Seo, Pil-Won;Ahn, Hyuk
    • Journal of Chest Surgery
    • /
    • v.21 no.5
    • /
    • pp.889-893
    • /
    • 1988
  • We experienced a case of infective endocarditis of aortic valve and tricuspid valve associated with a fistula between aorta and right ventricle. The patient was 35 years old woman and showed severe congestive heart failure. Large and multiple vagetations were found on the valvular surfaces and a fistula was present between aorta and right ventricle. Probably infective endocarditis of aortic valve resulted in annular abscess and as it healed, a fistula was formed and tricuspid valve endocarditis followed. We replaced the aortic valve and tricuspid valve with St. Jude mechanical prostheses, and closed the fistula opening with suture. The postoperative course was smooth and the patient has no problems till now 4 months after operation.

  • PDF

Diffuse Supravalvar Aortic Stenosis Associated with Congenital Anomaly of the Aortic Valve(Williams Syndrome) -1 case report- (선천성 대동맥 판막 이상과 무명동맥 협착이 동반된 미만성 대동맥 판막상부 협착증 치험 1례)

  • 김수철;전순호
    • Journal of Chest Surgery
    • /
    • v.33 no.9
    • /
    • pp.748-751
    • /
    • 2000
  • The diffuse form of supravalvar aortic stenosis represents a surgical challenge when the ascending aorta, aortic arch, proximal descending thoracic aorta and arch arteries are involved. It can be treated by a variety of surgical approaches. We report a case of severe diffuse supravalvar aortic stenosis combined with an aortic valve anomaly and occlusion of the right coronary artery ostium in a 14-year-old boy with Williams syndrome. We enlarged the aortic root(Nick's procedure), ascending aorta, aortic arch, proximal descending thoracic aorta, and innominate artery with patches and replaced aortic valve with 19 mm St. Jude valve. Deep hypothermic circulatory arrest and retrograde cerebral perfusion were used during repair of the arch and arch artery.

  • PDF

Mass Reduction and Functional Improvement of the Left Ventricle after Aortic Valve Replacement for Degenerative Aortic Stenosis

  • Shin, Su-Min;Park, Pyo-Won;Han, Woo-Sik;Sung, Ki-Ick;Kim, Wook-Sung;Lee, Young-Tak
    • Journal of Chest Surgery
    • /
    • v.44 no.6
    • /
    • pp.399-405
    • /
    • 2011
  • Background: Left ventricular (LV) hypertrophy caused by aortic valve stenosis (AS) leads to cardiovascular morbidity and mortality. We sought to determine whether aortic valve replacement (AVR) decreases LV mass and improves LV function. Materials and Methods: Retrospective review for 358 consecutive patients, who underwent aortic valve replacement for degenerative AS between January 1995 and December 2008, was performed. There were 230 men and 128 women, and their age at operation was $63.2{\pm}10$ years (30~85 years). Results: There was no in-hospital mortality, and mean follow-up duration after discharge was 48.9 months (2~167 months). Immediate postoperative echocardiography revealed that LV mass index and mean gradient across the aortic valve decreased significantly (p<0.001), and LV mass continued to decrease during the follow-up period (p<0.001). LV ejection fraction (EF) temporarily decreased postoperatively (p<0.001), but LV function recovered immediately and continued to improve with a significant difference between preoperative and postoperative EF (p<0.001). There were 15 late deaths during the follow-up period, and overall survival at 5 and 10 years were 94% and 90%, respectively. On multivariable analysis, age at operation (p=0.008), concomitant coronary bypass surgery (p<0.003), lower preoperative LVEF (<40%) (p=0.0018), and higher EUROScore (>7) (p=0.045) were risk factors for late death. Conclusion: After AVR for degenerative AS, reduction of left ventricular mass and improvement of left ventricular function continue late after operation.

Aortic Valve Replacement Using Balloon Catheter for Thoracic Endovascular Aortic Repair to Patient with Calcified Aorta

  • Kim, In Sook;Byun, Joung Hun;Yoo, Byung Ha;Kim, Han Yong;Hwang, Sang Won;Song, Yun Gyu
    • Journal of Chest Surgery
    • /
    • v.46 no.3
    • /
    • pp.212-215
    • /
    • 2013
  • A 79-year-old man was admitted to Samsung Changwon Hospital due to chest pain and dyspnea. The ejection fraction was 31% and mean pressure gradient between the left ventricle and aorta was 69.4 mmHg on echocardiography. Chest computed tomography showed severe calcification of the ascending aorta. Aortic valve replacement was successfully performed using a thoracic endovascular aortic repair balloon catheter without classic aortic cross clamping. The patient was discharged on the eleventh postoperative day.

Aortic Valve Replacement with Patch Enlargement of Aortic Annulus in Aortic Stenosis with small aortic Annulus. (소 대동맥 판막륜을 가진 대동맥판막 협착증 치험 1례 보고)

  • 권오춘
    • Journal of Chest Surgery
    • /
    • v.18 no.4
    • /
    • pp.663-666
    • /
    • 1985
  • Whatever a surgeon choose aortic prosthesis in aortic stenosis, it will always provoke some degree of obstruction to flow due to its smaller effective orifice area to tissue annulus. Occasionally, we meet small aortic annulus to his or her body surface area in aortic valve replacement. The small annulus remains a problem in that both tissue and mechanical prosthesis have significant pressure gradients between LV and aorta in resting or exercising states. In these circumstances, diverse surgical procedures, such as tilting disc prosthesis, supraannular position of aortic prosthesis, and enlargement of aortic root [including aortoventriculoplasty, translocation of aortic valve, & double outlet of LV by valved conduit], were applied. We experienced one case of aortic stenosis with small aortic annulus. Systolic pressure gradients between LV & aorta were 90 mmHg. Diameter of annulus was 19 mm. So we performed patch enlargement of aortic root by Manouguian and AVR with St. Jude medical valve 23 mm.

  • PDF

Prognosis of Unrepaired Ascending Aorta after the Surgical Replacement of Bicuspid Aortic Valves

  • Hong Ju Shin;Wan Kee Kim;Dong Kyu Kim;Ho Jin Kim;Joon Bum Kim
    • Journal of Chest Surgery
    • /
    • v.56 no.4
    • /
    • pp.255-261
    • /
    • 2023
  • Background: The surgical threshold for bicuspid aortic valve (BAV)-related aortopathy is a matter of debate due to its uncertain etiology and prognosis. This study investigated the prognosis of unrepaired BAV aortopathy in patients undergoing surgical aortic valve replacement (SAVR). Methods: We retrospectively analyzed data from 720 patients (age, 60.8±11.5 years; 246 women) who underwent SAVR for BAV disease without aortic repair between 2005 and 2020 at Asan Medical Center. The clinical endpoints were defined as occurrences of sudden death, aortic dissection or rupture, and elective aortic repair. To estimate postoperative changes in the dimensions of the unrepaired aorta, the individual annual aortic expansion rate was calculated. Multiple linear regression models were used to evaluate the risk of aortic expansion. Results: The mean ascending aortic diameter was 39.5±4.6 mm, and 299 patients (41.5%) had a baseline ascending aorta diameter >40 mm. During 70.0±68.3 months of follow-up, the mean annual aortic expansion rate was 0.39±1.96 mm/yr, no aortic dissection or rupture was observed, and sudden deaths were reported in 12 patients (0.34% per person-year). Linear regression analysis revealed no significant correlation between the baseline ascending aortic diameter and postoperative aortic expansion (R2=0.004, β=-0.84, p=0.082). Conclusion: In selected patients undergoing SAVR for a BAV (<55 mm), the risk of adverse aortic events was very low. As this observation contradicts current practice guidelines advocating for proactive aortic replacement in dilated ascending aortas measuring >45 mm, the study results need further validation by studies involving larger populations or randomized controlled trials.