• Title/Summary/Keyword: Aortic valve surgery

Search Result 584, Processing Time 0.02 seconds

Surgical Treatment of Annuloaortic Ectasia Report of One Case (Annuloaortic Ectasia 수술치험)

  • 김광택
    • Journal of Chest Surgery
    • /
    • v.18 no.3
    • /
    • pp.456-460
    • /
    • 1985
  • A case of Annuloaortic Ectasia associated with Marfan syndrome was treated by replacement of aorta and aortic valve with a valved conduit. A 26 years old man had suffered from palpitation and precordial pain. He had stigmata of Marfan`s syndrome. Aortogram and 2-D echocardiogram confirmed aneurysm of the ascending aorta with aortic insufficiency. Surgery was performed under the moderate hypothermia to 28oC. There was marked dilatation of the aortic annulus as well as sinus of Valsalva, with displacement of the coronary ostia. Aortic valve and aneurysm was replacement with 25mm, woven Dacron tubular graft, to which a 25mm, S.T. Jude Medical valve had been previously sutured. Right & left coronary ostia were anastomosed to the graft with the use of 3O Nylon pledget suture. The patient had a satisfactory post operation period with out specific complication.

  • PDF

One Stage Correction of the Pectus Excavatum with Marfan Syndrome (Marfan증후군의 수술 교정 1례)

  • Lee, Seung-Yeol;Nam, Yeong-Su;Kim, Hyeong-Muk
    • Journal of Chest Surgery
    • /
    • v.28 no.1
    • /
    • pp.65-68
    • /
    • 1995
  • Pectus excavatum occasionally occurs in patients who have underlying cardiac disease, especially Marfan syndrome. This report describes a patient with pectus excavatum who had ascending aortic aneurysm with aortic regurgitation and anterior leaflet prolapse of mitral valve. This patient underwent replacement of aortic valve and ascending aorta with 25 mm SJM valved conduit graft[Bentall operation with Cabrol shunt , and mitral valve replacement with SJM 31 mm, the pectus excavatum was corrected at the time of completion of the intracardiac operation with the modified sternal turnover. This procedure offered excellent operative exposure for the inracardiac operation with prevention of low cardiac output after operation due to depressed sternum and maintained chest wall stability resulting good cosmetic chest wall appearance. This patient recovered and discharged in good postoperative result with minimal temporary peroneal nerve palsy in his left leg.

  • PDF

One-stage Repair of Interrupted Aortic Arch with Ventricular Septal Defect and Valvular Aortic Stenosis - A case report- (심실 중격 결손과 대동맥 판 협착을 가진 대동맥 궁 단절의 일차 완전 교정술 -1예 보고-)

  • Cho, Joon-Yong;Jeong, Young-Kyun;Lee, Jong-Tae;Kim, Kyu-Tae;Chang, Bong-Hyun
    • Journal of Chest Surgery
    • /
    • v.38 no.12 s.257
    • /
    • pp.856-859
    • /
    • 2005
  • A male neonate was referred to our hospital with facial cyanosis and tachypnea at 19 days of age. Two-dimensional echocardiography showed type B interrupted aortic arch, posterior malalignment ventricular septal defect and valvular aortic stenosis. A new surgical repair was done with biventricular repair and neo-aortic arch reconstruction. Left ventricular outflow track (LVOT) was consisted of aortic valve and pulmonic valve. Right ventricular outflow (RVOT) track was reconstructed with extracardiac conduit. Postoperative two-dimensional echocardiography showed no stenosis and turbulency flow on LVOT and RVOT.

An Aortic Root Abscess Presenting as a Suprasternal Pulsatile Mass

  • Raman, Karthik;Sheriff, Ejaz Ahmed;Jamesraj, Jacob;Kumar, Ram
    • Journal of Chest Surgery
    • /
    • v.52 no.3
    • /
    • pp.178-181
    • /
    • 2019
  • Prosthetic valve endocarditis with aortic root abscess is a serious condition requiring urgent surgical intervention. We present a case caused by an infected Bentall mechanical valve conduit after cardiac surgery in a patient who was referred for a suprasternal pulsatile mass. The patient also had 1 episode of sentinel haemorrhage.

Thrombocytopenia in Moderate- to High-Risk Sutureless Aortic Valve Replacement

  • Thitivaraporn, Puwadon;Chiramongkol, Sarun;Muntham, Dittapol;Pornpatrtanarak, Nopporn;Kittayarak, Chanapong;Namchaisiri, Jule;Singhatanadgige, Seri;Ongcharit, Pat;Benjacholamas, Vichai
    • Journal of Chest Surgery
    • /
    • v.51 no.3
    • /
    • pp.172-179
    • /
    • 2018
  • Background: This study aimed to compare preliminary data on the outcomes of sutureless aortic valve replacement (SU-AVR) with those of aortic valve replacement (AVR). Methods: We conducted a retrospective study of SU-AVR in moderate- to high-risk patients from 2013 to 2016. Matching was performed at a 1:1 ratio using the Society of Thoracic Surgeons predicted risk of mortality score with sex and age. The primary outcome was 30-day mortality. The secondary outcomes were operative outcomes and complications. Results: A total of 277 patients were studied. Ten patients (50% males; median age, 81.5 years) underwent SU-AVR. Postoperative echocardiography showed impressive outcomes in the SU-AVR group. The 30-day mortality was 10% in both groups. In our study, the patients in the SU-AVR group developed postoperative thrombocytopenia. Platelet counts decreased from $225{\times}10^3/{\mu}L$ preoperatively to 94.5, 54.5, and $50.1{\times}10^3/{\mu}L$ on postoperative days 1, 2, and 3, respectively, showing significant differences compared with the AVR group (p=0.04, p=0.16, and p=0.20, respectively). The median amount of platelet transfusion was higher in the AVR group (12.5 vs. 0 units, p=0.052). Conclusion: There was no difference in the 30-day mortality of moderate-to high-risk patients depending on whether they underwent SU-AVR or AVR. Although SU-AVR is associated with favorable cardiopulmonary bypass and cross-clamp times, it may be associated with postoperative thrombocytopenia.

Aortic valve replacement in the patient with rheumatic heart disease (류마치스성 심장질환 환자에서 대동맥판막치환)

  • An, Jae-Ho;Lee, Yeong-Gyun
    • Journal of Chest Surgery
    • /
    • v.17 no.3
    • /
    • pp.346-355
    • /
    • 1984
  • 77 cases of Aortic Valve Replacement, which were composed of 64 rheumatic valvular heart disease and 13 combined congenital heart disease, were operated at Seoul National University Hospital for Aortic valvular disease during the period from June 1968 to December 1983. Among these 64 rheumatic aortic valvular heart disease cases, 8 patients were expired during and immediate after operation and overall mortality rate was 12.5%. For more precise remarks, these patients were divided into two periodic groups, 1st period [from 1968 to 1976] and 2nd [from 1977 to 1983] when annual open heart surgery were over 100 cases, and in 1st period three of four patients were died and in 2nd period five of sixty patients were died and its mortality rate was 8.3%. There were 12 cases of postoperative complication, which were 3 cases of remaining other valvular heart disease required MVR, 2 paravalvular leaks [one of them got Redo AVR], 4 thromboembolism or problem of anticoagulant therapy, 2 late death due to SBE with replaced valve failure and one functional AS with small sized valve. Operative death was affected by pump-time and aortic cross-clamping time, heart size, Ejection Fraction, LVEDP and symptom duration, and other many factors may influence the survival rate. Improved operative technique and myocardial protection and meticulous evaluation of the preoperative patient status will make the AVR safer.

  • PDF

Intravascular Hemolysis after Prosthetic Valve Replacement (인공판막 치환수술후의 용혈)

  • Jang, Won-Chae;Lee, Gye-Yeong;Kim, Sang-Hyeong
    • Journal of Chest Surgery
    • /
    • v.25 no.12
    • /
    • pp.1556-1562
    • /
    • 1992
  • Forty two consecutive patients who had had valve replacement with St. Jude Medical prosthesis were studied on a view point of intravascular hemolysis. Patients were consisted of 14 mitral valve replacement, and 7 aortic valve replacement, and 21 double, mitral and aortic, valve replacement. Serum LDH, indirect bilirubin, GOT, hemoglobin levels and ret-iculocyte count were pursued in postopeative 1st day, 3rd day, 7th day, 14th day and 21th day. Postoperatively, all patients were not detected paravalvular leakage on the ech-ocardiographical study. The patients with double valve replacement revealed higher levels of LDH on postopeative 14th day[P<0 05] than those with single valve replacement. Among the patients with single valve replacement, the patients with aortic valve replacement revealed slightly higher levels of entire postopeative data, but considered insignificant. There was correlation between the severity of hemolysis and the size of replaced aortic valve. In the postoperative LDH levels, the patients with small sized-aortic valve[less than 21mm in diameter] replacement revealed higher levels of postoperative 3rd day, 7th day and 14th day than those with large size[more than 23mm in diameter]. The patients with high level LDH of greater than 800 WU /L on postoperative 7th day were 61.9%[26 of 42]. The high LDH frequency of DVR was 71.4%[15 of 21], MVR 50.0%[7 of 14] and AVR, 57.1%[4 of 7]. The level of LDH declined gradualiy thereafter through postoperative 3 weeks. In conclusion, intravascular hemolysis after prosthetic valve replacement was dependent on position of valve replacement and size of valve. And this study supports the conventional valve selection and usage in our hospital. The patients with subclinical hemolysis after valve replacement should be placed on a close observation.

  • PDF

Long-Term Results of the Leaflet Extension Technique for Rheumatic Aortic Regurgitation: A 20-Year Follow-up

  • Kwak, Yu-jin;Ahn, Hyuk;Choi, Jae Woong;Kim, Kyung-Hwan
    • Journal of Chest Surgery
    • /
    • v.52 no.1
    • /
    • pp.9-15
    • /
    • 2019
  • Background: Although aortic valve repair can reduce prosthesis-related complications, rheumatic aortic regurgitation (AR) caused by leaflet restriction is a significant risk factor for recurrent AR. In this study, we evaluated the long-term results of the leaflet extension technique for rheumatic AR. Methods: Between 1995 and 2016, 33 patients underwent aortic valve repair using the leaflet extension technique with autologous pericardium for rheumatic pure AR. Twenty patients had severe AR and 9 had combined moderate or greater mitral regurgitation. Their mean age was $32.2{\pm}13.9$ years. The mean follow-up duration was $18.3{\pm}5.8$ years. Results: There were no cases of operative mortality, but postoperative complications occurred in 5 patients. Overall survival at 10 and 20 years was 93.5% and 87.1%, respectively. There were no thromboembolic cerebrovascular events, but 4 late deaths occurred, as well as a bleeding event in 1 patient who was taking warfarin. Twelve patients underwent aortic valve reoperation. The mean interval to reoperation was $13.1{\pm}6.1$ years. Freedom from reoperation at 10 and 20 years was 96.7% and 66.6%, respectively. Conclusion: The long-term results of the leaflet extension technique showed acceptable durability and a low incidence of thromboembolic events and bleeding. The leaflet extension technique may be a good option for young patients with rheumatic AR.

COR-KNOT-Induced Leaflet Perforation: How It Happens and How to Prevent It: A Case Report

  • Michael Salna;Jack Shanewise;Alex D'Angelo;Isaac George
    • Journal of Chest Surgery
    • /
    • v.57 no.1
    • /
    • pp.96-98
    • /
    • 2024
  • The COR-KNOT suture fastening device has dramatically improved the efficiency of valve suture fixation. Despite its relative ease of use, there are important considerations in deployment to limit the risk of prosthetic valve injury. Herein, we report a case of iatrogenic aortic bioprosthetic insufficiency caused by poorly positioned COR-KNOTs and outline technical strategies to ensure success.

Redo AVR: One Case Report (대동맥판막 재이식술 -1예 보고-)

  • Seong, Sang-Hyeon;Seong, Suk-Hwan;Lee, Yeong-Gyun
    • Journal of Chest Surgery
    • /
    • v.15 no.2
    • /
    • pp.254-258
    • /
    • 1982
  • We have experienced one case of Redo AVR which was performed 13 months after initial operation. The patient had received AVR [Bjork-Shiley disc valve] and MVR [Ionescu-Shiley tissue valve] because of ASI and MSI at March, 1981. During follow up through the OPD, he complained exertional dyspnea and progressive jaundice with hemolytic anemia was also noticed since 1 month prior to readmission. Cardiac catheterization and angiography revealed periaortic valvular leakage due to partial detachment of previously replaced prosthetic aortic valve. Re-replacement of prosthetic aortic valve with Ionescu-Shiley valve was performed and the patient was discharged at 17th POD without any complications.

  • PDF