• Title/Summary/Keyword: Aortic valve

검색결과 630건 처리시간 0.029초

Aortic Valve Sparing Operations: A Review

  • David, Tirone E.
    • Journal of Chest Surgery
    • /
    • 제45권4호
    • /
    • pp.205-212
    • /
    • 2012
  • Aortic valve sparing operations were developed to preserve the native aortic valve during surgery for aortic root aneurysm as well as surgery for ascending aortic aneurysms with associated aortic insufficiency. There are basically two types of aortic valve sparing oprations: remodeling of the aortic root and reimplantation of the aortic valve. These operations have been performed for over two decades and the clinical outcomes have been excellent in experienced hands. Although remodeling of the aortic root is physiologically superior to reimplantation of the aortic valve, long-term follow-up suggests that the latter is associated with lower risk of developing aortic insufficiency. Failure of remodeling of the aortic root is often due to dilatation of the aortic annulus. Thus, this type of aortic valve sparing should be reserved for older patients with ascending aortic aneurysm and normal aortic annulus whereas reimplantation of the aortic valve is more appropriate for young patients with inherited disorders that cause aortic root aneurysms. This article summarizes the published experience with these two operations. They are no longer experimental procedures and should be part of the surgical armamentarium to treat patients with aortic root aneurysm and ascending aortic aneurysms with associated aortic insufficiency.

Surgical Management of Aortic Root Dilatation with Advanced Aortic Regurgitation: Bentall Operation versus Valve-sparing Procedure

  • Lim, Ju-Yong;Kim, Joon-Bum;Jung, Sung-Ho;Choo, Suk-Jung;Chung, Cheol-Hyun;Lee, Jae-Won
    • Journal of Chest Surgery
    • /
    • 제45권3호
    • /
    • pp.141-147
    • /
    • 2012
  • Background: Although the aortic valve-sparing procedure has gained popularity in recent years, it still remains challenging in patients with advanced aortic regurgitation (AR). We compared the long-term outcomes of the aortic valve-sparing procedure with the Bentall operation in patients with advanced aortic regurgitation secondary to aortic root dilatation. Materials and Methods: A retrospective review of 120 patients who underwent surgery for aortic root dilatation with moderate to severe AR between January 1999 and June 2009 was performed. Forty-eight patients underwent valve-sparing procedures (valve-sparing group), and 72 patients underwent the Bentall procedure (Bentall group). The two groups' overall survival, valve-related complications, and aortic valve function were compared. Results: The mean follow-up duration was $4.9{\pm}3.1$ years. After adjustment, the valve-sparing group had similar risks of death (hazard ratio [HR], 0.61; p=0.45), and valve related complications (HR, 1.27; p=0.66). However, a significant number of patients developed moderate to severe AR in the valve-sparing group at a mean of $4.4{\pm}2.5$ years of echocardiographic follow-up (p<0.001). Conclusion: Both the Bentall operation and aortic valve-sparing procedure showed comparable long-term clinical results in patients with advanced aortic regurgitation with aortic root dilatation. However, recurrent advanced aortic regurgitation was more frequently observed following valve-sparing procedures.

Bentall Operation in a Patient with a Unicommissural Unicuspid Aortic Valve

  • Park, Sung Joon;Lee, Jae Hoon;Chung, Eui Suk
    • Journal of Chest Surgery
    • /
    • 제52권5호
    • /
    • pp.368-371
    • /
    • 2019
  • A unicuspid aortic valve is a rare congenital malformation that frequently presents with valvular dysfunction and dilatation or aortic aneurysm, requiring combined aortic valve surgery and aortic repair. Some patients show severe valve calcification extending into the interventricular septum, possibly resulting in damage to the conduction system during debridement for valve replacement. We present a rare case of severe aortic stenosis with a unicommissural unicuspid aortic valve diagnosed by preoperative transesophageal echocardiography in a 36-year-old man. After composite graft replacement of the aortic valve, aortic root, and ascending aorta, a permanent pacemaker was placed because of postoperative complete heart block.

심초음파도를 이용한 대동맥인공판막치수 예 (Two-Dimensional Echocardiographic Prediction of Prosthetic Aortic Valve Size)

  • 박창권
    • Journal of Chest Surgery
    • /
    • 제20권4호
    • /
    • pp.655-658
    • /
    • 1987
  • Aortic annulus size was measured by two-dimensional echocardiography [2DE] in 29 patients undergoing aortic valve replacement or double valve replacement in order to predict prosthetic aortic valve size. Fifteen patients had aortic stenoinsufficiency, eleven had aortic insufficiency, and three had aortic stenosis. 2DE measurements of aortic annulus diameter, as determined from the parasternal long-axis view, demonstrated a high correlation with actual prosthetic valve size implanted at surgery [r=0.85, p<0.05]. 2DE exactly predicted actual prosthetic valve size in 8 of 29 patients [27.6%], was within 1mm of prosthetic valve size in 11 of 29 patients [37.9%], was within 2mm of prosthetic valve size in 8 of 29 patients, and was within 3mm of prosthetic valve size in 2 patients.

  • PDF

동맥근 농양 및 좌심실유출호 가성 심실류 환자에서 폐동맥 자가이식편을 이용한 대동맥근부치환술 -1례 치험 보고- (Aortic Root Replacement with Pulmonary Autograft in Patient with Subaortic Abscess and False Aneurysm in Left Ventricular Outflow Tract -Report of A Case-)

  • 장병철
    • Journal of Chest Surgery
    • /
    • 제28권7호
    • /
    • pp.704-707
    • /
    • 1995
  • The use of the patient`s pulmonary valve for replacement of the patient`s diseased aortic valve was introduced and developed by Mr. Donald Ross. The long term benefits of having a normal, fully viable, trileaflet semilunar valve in aortic position was demonstrated. A 38 year old male had histories of failures of previously implanted aortic prosthetic valves twice and evidence of progressive heart failure. At operation, aortic root abscess was found; the abscess extension to adjacent structures and partial valve dehiscence had occurred. The patient underwent replacement of the aortic root with autologous pulmonary valve, autologous pericardial patch repair of left ventricuar outflow tract and recontruction of the right ventricular outflow tract and pulmonary artery with prosthetic valved conduit. Postoperatively, the patient recovered well. Postoperative doppler echocardiography demonstrated minimal central regurgitation in new aortic valve. Aortic root replacement with pulmonary autograft in a patient of recurrent aortic root abscess and false aneurysm of left ventricuar outflow tract was experienced and reported with follow up echocardiography.

  • PDF

4첨 대동맥판막 환자에서 발생한 대동맥 판막폐쇄부전 -1례 보고- (Quadricuspid Aortic Valve Associated with Aortic Regurgitation -Report of A case-)

  • 박국양;김성철;김창호
    • Journal of Chest Surgery
    • /
    • 제23권3호
    • /
    • pp.527-531
    • /
    • 1990
  • A 11 year-old girl with quadricuspid aortic avlve associated with regurgitation left superior vena cava and chromosomal anomaly is presented. The quadricuspid valve was unexpectedly found during operation for aortic valve replacement. The aortic valve consisted of 4 equal-sized cusps and retrospective review of the aortogram revealed the aortic valve to have 4 cusps also. To the best of our knowledge, this combination of anomalies has not been reported in Korea previously.

  • PDF

선천성 대동맥 판막 이상과 무명동맥 협착이 동반된 미만성 대동맥 판막상부 협착증 치험 1례 (Diffuse Supravalvar Aortic Stenosis Associated with Congenital Anomaly of the Aortic Valve(Williams Syndrome) -1 case report-)

  • 김수철;전순호
    • Journal of Chest Surgery
    • /
    • 제33권9호
    • /
    • pp.748-751
    • /
    • 2000
  • The diffuse form of supravalvar aortic stenosis represents a surgical challenge when the ascending aorta, aortic arch, proximal descending thoracic aorta and arch arteries are involved. It can be treated by a variety of surgical approaches. We report a case of severe diffuse supravalvar aortic stenosis combined with an aortic valve anomaly and occlusion of the right coronary artery ostium in a 14-year-old boy with Williams syndrome. We enlarged the aortic root(Nick's procedure), ascending aorta, aortic arch, proximal descending thoracic aorta, and innominate artery with patches and replaced aortic valve with 19 mm St. Jude valve. Deep hypothermic circulatory arrest and retrograde cerebral perfusion were used during repair of the arch and arch artery.

  • PDF

Valve-Sparing Root Replacement in a Turner Syndrome Patient with Bicuspid Aortic Valve and Juxtacommissural Origin of the Right Coronary Artery: A Case Report

  • Son, Dong Hyeon;Cho, Sungkyu;Song, Mi Kyoung
    • Journal of Chest Surgery
    • /
    • 제55권5호
    • /
    • pp.413-416
    • /
    • 2022
  • A 32-year-old woman diagnosed with Turner syndrome presented to the hospital for an evaluation of cardiovascular complications. Preoperative computed tomography (CT) and echocardiography showed progression of aortic root and ascending aorta dilatation, as well as a bicuspid aortic valve. There was no evidence of aortic regurgitation. We planned valve-sparing aortic root replacement and ascending aorta replacement with a high risk of aortic rupture. Intraoperatively, we incidentally found a juxtacommissural origin of the right coronary artery (RCA). We performed aortic valve reimplantation using a graft designed with a key-shaped hole to wrap the juxtacommissural-origin RCA by modifying the Florida sleeve technique. Coronary blood flow was patent on postoperative CT angiography, and there was no evidence of aortic regurgitation on postoperative echocardiography. The patient was discharged from the hospital on postoperative day 7 without any complications.

대동맥판을 보존한 대동맥근부치환술 - 증례보고 - (Aortic Root Replacement with Valve Preservation in a Patient with Annuloaortic Ectasia)

  • 김대준;윤치순;장병철
    • Journal of Chest Surgery
    • /
    • 제31권12호
    • /
    • pp.1234-1237
    • /
    • 1998
  • Marfan 증후군과 같은 대동맥 질환의 경우 대동맥동 및 대동맥륜의 점진적인 확장 및 변형이 발생하여 대동맥판막의 폐쇄부전을 초래한다. 이런 경우 대부분 상행대동맥과 대동맥 판막을 composite graft의 형태로 치환하고 여기에 관상동맥을 문합하는 술식이 적용되어왔다. 본 증례는 Marfan 증후군이 동반된 22세 남자 환자로 대동맥 근부 확장과 승모판막 부전이 있었다. 수술은 대동맥 판막 및 좌심실유출로의 일부를 보존하면서 상행대동맥 및 Valsalva동의 동맥류를 제거하고, 대동맥 판막 및 관상동맥을 인조혈관에 다시 문합하는 술식을 적용하였다. 술후 심초음파 검사상 대동맥 판막의 기능은 정상이었다. 대동맥륜 확장증에 있어서 대동맥 판막이 정상적인 해부학적 구조를 가진다면 이상의 술식을 적용함으로써 자신의 대동맥 판막은 보존하면서 대동맥 근부를 치환할 수 있으리라 생각된다.

  • PDF

Comparable Outcomes of Bicuspid Aortic Valves for Rapid-Deployment Aortic Valve Replacement

  • Somin Im;Kyung Hwan Kim;Suk Ho Sohn;Yoonjin Kang;Ji Seong Kim;Jae Woong Choi
    • Journal of Chest Surgery
    • /
    • 제56권6호
    • /
    • pp.435-444
    • /
    • 2023
  • Background: Edwards Intuity is recognized as a relatively contraindicated bioprosthesis for bicuspid aortic valve disease. This study compared the early echocardiographic and clinical outcomes of rapid-deployment aortic valve replacement for bicuspid versus tricuspid aortic valves. Methods: Of 278 patients who underwent rapid-deployment aortic valve replacement using Intuity at Seoul National University Hospital, 252 patients were enrolled after excluding those with pure aortic regurgitation, prosthetic valve failure, endocarditis, and quadricuspid valves. The bicuspid and tricuspid groups included 147 and 105 patients, respectively. Early outcomes and the incidence of paravalvular leak were compared between the groups. A subgroup analysis compared the outcomes for type 0 versus type 1 or 2 bicuspid valves. Results: The bicuspid group had more male and younger patients. Comorbidities, including diabetes mellitus, hypertension, chronic kidney disease, and coronary artery disease, were less prevalent in the bicuspid group. Early echocardiographic evaluations demonstrated that the incidence of ≥mild paravalvular leak did not differ significantly between the groups (5.5% vs. 1.0% in the bicuspid vs. tricuspid groups, p=0.09), and the early clinical outcomes were also comparable between the groups. In the subgroup analysis between type 0 and type 1 or 2 bicuspid valves, the incidence of mild or greater paravalvular leak (2.4% vs. 6.7% in type 0 vs. type 1 or 2, p=0.34) and clinical outcomes were comparable. Conclusion: Rapid-deployment aortic valve replacement for bicuspid aortic valves demonstrated comparable early echocardiographic and clinical outcomes to those for tricuspid aortic valves, and the outcomes were also satisfactory for type 0 bicuspid aortic valves.