• 제목/요약/키워드: Aortic valve, replacement

검색결과 420건 처리시간 0.024초

Ebstein 심기형 수술 1례[Plication 및 삼첨판막 이식예] (Ebstein`S Anomaly: A Case Report of Plication and Tricuspid Valve Replacement)

  • 송명근
    • Journal of Chest Surgery
    • /
    • 제11권3호
    • /
    • pp.342-347
    • /
    • 1978
  • A 8 year old male was admitted to the Department of Thoracic Surgery, Korea University Hospital on June 22, 1978. The chief complaints were cyanosis and exertional dyspnea since at birth. EKG shows BVH and dextrocardia, phonocardiogram revealed the accentuation of second heart sound in aortic area. Echocardiogram from the left ventricle to the base of the heart, there is a discontinuity between the ventricular septum and the anterior aortic margin with a large aortic root & aortic overriding. His cardiac catheterization data and cardiac angiogram shows situs inversus totalis, dextrocardia, right aortic arch, large ventricular septal defect etc., and finally diagnosed Truncus Arteriosus. Edwards type IV with retrograde aortogram and selective bronchial angiogram. This is the first operative case reported as Rastelli operation for Truncus Arteriosus type IV in the literatures in Korea. Authors have experienced I case of Truncus Arteriosus, Edward type IV and Rastelli operation with Dacron Arterial Conduit Graft under cardiopulmonary bypass on July 3, 1978. The procedures were as follows; 2] Cardiopulmonary bypass: Origin of bronchial arteries excised from descending aorta bilaterally; defects in aorta closed. 2] Horizontal incision made high in right ventricle. 2] Ventricular septal defect [Kirklin type I+II] closed with Teflon patch. 4] Bifurcated dacron arterial graft with pericardial monocusp sutured to the bilateral pulmonary arteries. [Diameter 9 mm: Length 7 cm]. 5] Proximal end of the conduit graft anastomosed to right ventricle. [Diameter 19 mm: Length 5 cm]..Total perfusion time was 220 min. The result of operation was poor due to anastomotic leakage and increased pulmonary vascular resistance resulting acute right heart failure. The patient was died on the operation table. Literatures were briefly reviewed.

  • PDF

협소한 대동맥판륜 환자에서의 대동맥판막 치환술; 대동맥판륜 확장술군과 환자-인공판막 부조화군의 비교 (Small Aortic Annulus in Aortic Valve Replacement; Comparison between Aortic Annular Enlargement Group and Patient-prosthesis Mismatch Group)

  • 김재현;오삼세;이길수;신성호;백만종;나찬영
    • Journal of Chest Surgery
    • /
    • 제40권3호
    • /
    • pp.200-208
    • /
    • 2007
  • 배경: 대동맥판막 치환술 후 발생하는 환자-인공판막 부조화(patient-prosthesis mismatch, PPM)가 환자의 경과에 어떠한 영향을 주는가에 대해서는 아직 논란의 여지가 있다. 이 연구는 대동맥판막 치환술 후 PPM이 발생한 환자군과 PPM을 예방하기 위해 대동맥판륜 확장술을 시행한 환자군 간의 수술 결과와 경과를 비교해 보았다. 대상 및 방법: 1996년 1월부터 2006년 2월까지 stent가 있는 조직판막 혹은 기계판막을 이용하여 대동맥판막 치환술을 시행 받은 627명의 성인 환자를 연구대상으로 하였다. 치환된 대동맥판막의 indexed effective orifice area (iEOA)가 $0.85cm^2/m^2$ 이하인 경우를 PPM으로 정의 하였고 $0.65cm^2/m^2$ 이하는 심한 PPM으로 정의하였다 PPM은 103명(16.4%, PPM군)에서 발생하였고 심한 PPM은 11명(1.8%, SPPM군)에서 발생하였다. 동일한 연구 기간 동안 대동맥판륜 확장술을 시행 받은 환자(Annular Enlargement군, AE)는 모두 21명이었다. 결과: AE군의 평균 iEOA는 PPM군보다 더 컸다($0.95\;vs.\;0.76cm^2/m^2,\;p=0.00$). AE군은 PPM군보다 심폐바이패스 시간, 심장허혈 시간 및 수술 시간이 더 길었으며 수술 사망률이 더 높은 경향을 보였다(14.3% vs. 2.9%, p=0.06). 술 후 가장 최근에 시행한 심초음파 검사에서 SPPM군은 대동맥판막 판구 압력차(최고/평균)가 AE군보다 더 높게 나타났으며(72/45 mmHg vs. 38/25 mmHg, p=0.02/0.06), 대동맥판막 관련 문제(대동맥판막 재치환술 혹은 심한 대동맥판막 협착)가 더 많이 발생하였다(45.5% vs. 9.5%, p=0.03). 또한 대동맥판막 관련 문제가 발생한 환자들에서는 좌심실 심근량 감축(regression)을 관찰할 수 없었다. 결론: 협소한 대동맥판륜을 가진 환자에서 대동맥판륜 확장술의 시행여부는 대동맥판륜 확장술 자체의 위험도와 환자 상태 및 동반 질환 등을 함께 고려하여 신중히 결정하여야 한다. 하지만 대동맥판막 치환술 후 심한 PPM이 예상되는 환자에서는 대동맥판륜 확장술이 대안으로 이용될 수 있다.

소아심장판막치환술 (Valve Replacement in Children)

  • 김재현;이광숙;윤경찬;유영선;박창권;최세영
    • Journal of Chest Surgery
    • /
    • 제32권4호
    • /
    • pp.341-346
    • /
    • 1999
  • 배경: 소아에서의 심장판막치환술은 성인에서의 심장판막치환술의 제반문제 이외에도 작은 판막의 혈류역학적 문제, 신체발육에 따른 재수술, 출산 및 항응고요법에 따른 여러 문제점이 있다. 이에 본 연구에서는 계명대학교 동산의료원 흉부외과에서 경험한 심장판막치환술에 대하여 후향적 조사를 실시하여 소아 심장판막치환술의 여러 문제점과 해결책을 규명하려 하였다. 대상 및 방법: 1982년부터 1997년까지 15세 이하 소아 30명에서 심장판막치환술을 시행하였다. 남아가 16명, 여아가 14명이었으며, 연령 분포는 3세에서 15세로 평균 연령은 12.1$\pm$3.2세 였다. 판막 부위별로 보면 승모판치환술 15례, 대동맥판치환술 11례, 삼첨판치환술이 3례였으며, 승모판 및 대동맥판치환술이 1례 있었다. 판막질환의 원인을 보면 선천성이 17명, 후천성이 13명이었다. 이용한 판막으로는 조직판막 10례, 기계판막 20례였으며 1985년 이후로는 조직판막은 사용하지 않았다. 기계판막치환 환자에서는 술후 coumadin으로 항응고치료를 지속하였으며, 조직판막치환 환자에서는 술후 3개월간 coumadin을 복용하였다. 판막치환술 이전에 심장수술을 받은 환자는 8명으로 엡스타인씨기형 교정술 2례, 심실중격결손증과 대동맥폐쇄부전의 교정술 2례가 있었으며, 그 외 대동맥판막하협착, 방실중격결손증, 대동맥판협착증 및 심실중격결손증 등의 교정술이 각각 1례씩 있었다. 판막치환시 동시에 시행한 술식으로는 삼첨판륜성형술 3례, 심실중격결손증 교정 2례, 동맥관개존증 결찰 2례, 대동맥판륜확장술 2례, 심실중격결손증과 동맥관개존증 교정 1례, 승모 풉낮첬括珝낵\ulcorner1례등이 있었다. 결과: 수술사망은 2례로 조기사망률은 6.7%였다. 수술생존자 28명중 4명은 장기추적관찰이 불가능하였으며, 총 2091환자.월(평균 74.7$\pm$68.4개월, 최장 187개월)동안 관찰하였다. 이 기간중 판막의 혈전, 혈전색전증 및 항응고치료에 따른 출혈등의 합병증은 없었으나, 조직판막을 이용한 10례중 8례에서 술후 평균 87.1$\pm$23.6개월에 판막기능부전으로 재수술하였으며(이중 2례는 타 병원에서 수술함), 기계판막을 치환한 1례에서 판막주위누출과 감염으로 술후 3개월째 재수술하였다. 재수술시 사망례는 없었다. 만기사망은 1례로 방실중격결손증 교정술후 잔존 승모판폐쇄부전으로 승모판치환술을 받은 7세환아로 판막치환술후 4개월에 확장성심근염으로 사망하였다. 조직판막의 경우 생명표분석에 의한 판막실패가 없는 장기누적률은 6년째 75.0%, 7년째 50.0%, 8년째 12.5%의 기록을 보여 술후 6년에서 8년에 걸쳐 격감하는 양상을 보였다. 수술사망 2례를 제외한 28명의 장기생존률을 Kaplan-Meiyer법에 의해 분석하였을때 4개월째 생존률이 96.0%로 그 이후로는 사망례가 없었다. 결론:이상의 결과로 보아 소아 심장판막치환술은 비교적 안전하고, 술후 적절한 추적관찰이 행해질 경우 항응고요법에 따른 합병증은 거의 없으나, 5세이하 소아나 판막치환술 이전에 심장수술을 한 경우는 위험도가 여전히 높은 것으로 사료된다.

  • PDF

동맥전환술 후의 신생대동맥근부 확장과 대동맥판막폐쇄부전의 관계 (Relation of Neoaortic Root Dilation and Aortic Insufficiency after Arterial Switch Operation)

  • 박한기;김도균;홍유선;이종균;최재영;조범구;박영환
    • Journal of Chest Surgery
    • /
    • 제36권12호
    • /
    • pp.921-927
    • /
    • 2003
  • 동맥전환술은 대혈관전위증의 가장 효과적인 수술 방법이 되어왔다. 그러나 동맥전환술 후 신생대동맥근부가 과도하게 확장되는 현상이 보고되었으며, 이에 따른 신생대동맥판막의 기능과 대동맥의 성장에 미치는 영향에 대해서는 잘 알려져 있지 않다. 본 연구에서는 신생대동맥판막과 대동맥의 수술 후 크기의 변화와 신생대동맥판막의 기능 및 기능에 영향을 미치는 요인을 조사하였다. 대상 및 방법: 대동맥전환술을 받고 추적관찰기간 중 심도자술을 시행 받은 48명의 환자들이 연구 대상이 되었으며, 동맥전환술은 나이 중앙값 생후 18일(1∼211일)에 시행받았다. 수술 전 심도자술은 26명의 환자에서 시행되었고, 수술 후 15.8$\pm$9.6개월에 모든 환자에서 심도자술을 시행하였다. 수술 후의 하행대동맥에 대한 신생대동맥륜, 대동맥근부과 대동맥문합부위의 직경 비율을 수술 전의 폐동맥륜, 근위부 및 동관경계부위의 크기와 비교하였다. 수술 전과 수술 시의 변수에 대한 신생대동맥판막폐쇄부전의 위험인자를 분석하였다. 결과: 추적관찰 중 2명의 환자에서 중등도 이상의(grade$\geq$II/IV) 대동맥판막폐쇄부전이 있었으며 이 중 1명은 대동맥판막치환술이 필요하였다. 1명의 환자에서 대동맥문합부 협착으로 재수술이 필요하였다. 수술 후 neoaortic annulus/DA 비는 1.33$\pm$0.28에서 1.52$\pm$0.33로 증가하였고(p=0.01), neoaortic root/DA 비도 2.02$\pm$0.40에서 2.56$\pm$0.38로 증가하였다(p<0.0001). 그러나 aortic anastomosis/DA 비는 통계적으로 유의한 차이는 없었다(p=0.06). 신생대동맥판폐쇄부전의 발생과 neoaortic annulus/DA 비, neoaortic root/DA 비율에는 통계적으로 유의한 상관관계는 없었다. 신생아기 이후의 교정(나이>30일)(p=0.02), 수술 전 폐동맥판막협착(p=0.01)과 이엽성폐동맥판막(p=0.03)이 단일변수 분석에서 대동맥판막폐쇄부전의 위험인자이었다. 결론: 동맥전환술 후 대동맥문합부는 하행대동맥의 성장에 비례하는 정상 성장을 보이나 신생대동맥판막륜과 대동맥근부는 이상 확장을 보였다. 신생대동맥판막륜과 대동맥근부의 크기는 대동맥폐쇄부전과 직접적으로 연관되어 있지 않았으며, 임상적으로 의미 있는 대동맥판막폐쇄부전은 동맥전환술 후 드물게 발생했다. 신생아기 이후의 동맥전환술, 수술 전 폐동맥협착, 이엽성 폐동맥판막이 신생대동맥판막 폐쇄부전의 위험인자였다.

A Korean Multi-Center Survey about Warfarin Management before Gastroenterological Endoscopy in Patients with a History of Mechanical Valve Replacement Surgery

  • Son, Kuk Hui;Choi, Chang-Hyu;Lee, Jae-Ik;Kim, Kun Woo;Kim, Ji Sung;Lee, So Young;Park, Kook Yang;Park, Chul Hyun
    • Journal of Chest Surgery
    • /
    • 제49권5호
    • /
    • pp.329-336
    • /
    • 2016
  • Background: Guidelines for esophagogastroduodenoscopy (EGD) in the West allow the continued use of warfarin under therapeutic international normalized ratio (INR) level. In Korea, no guidelines have been issued regarding warfarin treatment before EGD. The authors surveyed Korean cardiac surgeons about how Korean cardiac surgeons handle warfarin therapy before EGD using a questionnaire. Participants were requested to make decisions regarding the continuation of warfarin therapy in two hypothetical cases. Methods: The questionnaire was administered to cardiac surgeons and consisted of eight questions, including two case scenarios. Results: Thirty- six cardiac surgeons at 28 hospitals participated in the survey, and 52.7% of the participants chose to stop warfarin before EGD in aortic valve replacement patients without risk factors for thromboembolism. When the patient's INR level was 2, 31% of the participants indicated that they would choose to continue warfarin therapy. For EGD with biopsy, 72.2% of the participants chose warfarin withdrawal, and 25% of the participants chose heparin replacement. In mitral valve replacement patients, 47.2% of the participants chose to discontinue warfarin, and 22.2% of the participants chose heparin replacement. For EGD with biopsy in patients with a mitral valve replacement, 58.3% of the participants chose to stop warfarin, and 41.7% of the participants chose heparin replacement. Conclusion: This study demonstrated that attitudes regarding warfarin treatment for EGD are very different among Korean surgeons. Guidelines specific to the Korean population are required.

St. Jude Medical 기계판막의 임상적 연구 (Clinical Analysis of St. Jude Medical Prosthesis)

  • 최순호
    • Journal of Chest Surgery
    • /
    • 제24권2호
    • /
    • pp.171-181
    • /
    • 1991
  • Result of St. Jude Medical valve replacement are presented in 106 patients who underwent operation from January 1985 through July 1989. The patient were 52 males and 56 females. Total 136 of St. Jude Medical valves were implanted; 91 in mitral position, 45 in aortic position. The hospital mortality rate was 5.7%o[6 patients] and the late mortality rate was 2.0%[2 patients]. The causes of death were low cardiac output in 5, iatrogenic right ventricular rupture in 1, heart failure in 1, ventricular arrhythmia in l. And, the causes of valve related complication were anticoagulant related hemorrhage in 5 patients[0.03% /patient-year] and thromboembolism[0.01% /patient-year] in 2 patients. In conclusion, the performance of the St. Jude Medical valve compare most favorably with other artificial valves. But it remains still hazards of mechanical prosthesis such as thromboembolism and anticoagulant related hemorrhage.

  • PDF

대동맥판 폐쇄부전증이 동반된 심실중격결손증 수술의 장기 성적- 적절한 수술시기 및 수술 방법- (Long-term Results of Surgical Treatment for Ventricular Septal defect Associated Aortic Insufficiency-Proper Timing and Method of Surgical Treatment)

  • 김진국;함시영;서경필
    • Journal of Chest Surgery
    • /
    • 제21권2호
    • /
    • pp.254-269
    • /
    • 1988
  • 52 cases of ventricular septal defect [VSD] associated with aortic insufficiency [Al] were found among 1271 patients with simple VSD operated during 27-year period [1959, August-1987, June] at Seoul National University Hospital. Their preoperative data, intraoperative findings and postoperative short-term and long-term follow-up data were evaluated to find the proper timing and method of surgical treatment. The result of this survey shows as follows: 1. To obtain the proper surgical indication, cardiac catheterization and angiography, especially root aortography, was essential. 2. Of all 52 patients, the VSD were type I in 40 patients [77%], type II in 8 [15%] and combination of type I and II in 4 [3%]. Patch closure of VSD were performed in 46 patients and direct suture closure of small VSD in 6. Most common pathologic findings of Al were prolapse of right coronary cusp [40 cases, 77%]. Aortic valve reconstruction were performed in 19 patients, aortic valve replacement in 6 and VSD closure alone in 27. 3. There were 3 surgical deaths [mortality 5.8%], and the long-term follow-up shows that VSD closure alone might have been sufficient to arrest progression of Al in younger patients [less than 10-year old], particularly in those with mild insufficiency. Valve reconstructions, when necessary, were more effective when done at an early age [less than 15-year old]. In a conclusion, we could recommend followings: 1. If patient at any age having VSD with Al is diagnosed, prompt operation is recommended. As for the surgical method, VSD closure only may be fit for mild degree of Al when patient is less than 10-year old, but the management of valve itself may be needed for moderate to severe degree of Al, especially when patient is over 10 year old. The management of valve itself may be variable, but valve reconstruction should be considered as a first choice in less than 15-year old patient. If patient is diagnosed less than 5-year old without evidence of Al, close follow-up observation is recommended. But if Al evidences of clinical findings and/or echocardiography during follow-up examination are notified, corrective operation should be accomplished while the Al is mild. If cusp prolapse and/or even type I VSD of significant size is demonstrated on aortogram, without Al, it should be corrected as early as possible before the patient is about 5 years old.

  • PDF

생물학적 보철판막의 조직실패 (Primary Tissue Filure of Bioprosthetic Valves)

  • 김종환
    • Journal of Chest Surgery
    • /
    • 제26권9호
    • /
    • pp.667-676
    • /
    • 1993
  • Boprosthetic cardiac valves fail from biological and metabolic as well as mechanical reasons, and the limited durability is the main factor of marked withdrawal in their clinical use. Starting the use of bioprosthetic valves in 1976, up to the end of 1992, the consecutive 178 patients have undergone re-replacement of glutaraldehyde-treated xenograft valves for primary tissue failure [PTF]among the patients who had initial valve replacement at Seoul national University Hospital. The explanted valves were 69 porcine aortic [51 Hancock, 12 Angell-Shiley and 6 Carentier-Edwards] and 141 bovine pericardial [129 standard-profile and 12 low-profile ionescu-Shiley] valwes, with an overall incidence of PTF of 15.2%. The operative mortality rate of re-replacement was 5.1%. Calcific degeneration and tissue damage in relation to calcification were the most frequent modes of PTF on gross examinatin of the explanted valves resulting hemodynamically in valvular regurgitation. The number of Hancocg porcine and the standard-profile Ionescu-Shiley valves in valves in mitral position failed more often from tissue damage [tears, holes, and loss or destruction of cuspal tissue] than calcification [68.3% vs. 39.0%, p<0.01] with resultant regurgitation in 61%, the Ionescu-Shiley valves in the same position in 53%. The tendency of more calcification than tissue damage[71.3% vs. 33.3%, p<0.001]with stenosis in 53%. The tendency of more calcification and immobility of cusps in the latter group was partly explainable by the inclusion of patients of pediatric age. Observation made in this study suggest : many of bioprosthetic valves would fail from calcification and tissue damage : some fail prematurely because of mechanical stress probably owing to the valve design in construction ; andeven those valves escaped early damage would be subject to calcify in the prolonged follow-up period. In conclusion, at the present time, the clinical use of bioprostheticxenograft valves seems to be quite limited until further improvement in biocompatibility and refinement in valve design in manufacture are achieved.

  • PDF

Hemodynamic Performance of Pericardial Bioprostheses in the Aortic Position

  • Lee, Haeju;Hwang, Ho Young;Sohn, Suk Ho;Choi, Jae Woong;Park, Jun-Bean;Kim, Kyung Hwan;Kim, Ki-Bong
    • Journal of Chest Surgery
    • /
    • 제53권5호
    • /
    • pp.285-290
    • /
    • 2020
  • Background: This study was conducted to evaluate the hemodynamic performance and the incidence of prosthesis-patient mismatch (PPM) after aortic valve replacement (AVR) using bovine pericardial valves (Carpentier-Edwards Perimount Magana and Magna Ease). Methods: In total, 216 patients (mean age, 70.0±10.5 years) who underwent AVR using stented bovine pericardial valves and had follow-up echocardiography between 3 months and 2 years (mean, 12.0±6.6 months) after surgery were enrolled. The implanted valve sizes were 19, 21, 23, and 25 mm in 32, 56, 99, and 29 patients, respectively. Results: On follow-up echocardiography, the mean transvalvular pressure gradients for the 19-mm, 21-mm, 23-mm, and 25-mm valves were 13.3±4.4, 12.6±4.2, 10.5±3.9, and 10.2±3.7 mm Hg, respectively. The effective orifice area (EOA) was 1.25±0.26, 1.54±0.31, 1.81±0.41, and 1.87±0.33 ㎠, respectively. These values were smaller than those suggested by the manufacturer for the corresponding sizes. No patients had PPM, when based on the reference EOA. However, moderate (EOA index ≤0.85 ㎠/㎡) and severe (EOA index ≤0.65 ㎠/㎡) PPM was present in 56 patients (11.8%) and 9 patients (1.9%), respectively, when using the measured values. Conclusion: Carpentier-Edwards Perimount Magna and Magna Ease bovine pericardial valves showed satisfactory hemodynamic performance with low rates of PPM, although the reference EOA could overestimate the true EOA for individual patients.

인공 대동맥판막 기능부전을 일으킨 특발성 과호산구 증후군 -1예 보고- (Dysfunction of the Prosthetic Aortic Valve in Idiopathic Hypereosinophilic Syndrome -A case report -)

  • 유동곤;성규완;정상식;강길현;김종욱;박종빈
    • Journal of Chest Surgery
    • /
    • 제40권4호
    • /
    • pp.297-300
    • /
    • 2007
  • 특발성 과호산구 증후군은 호산구 매개에 의한 조직 손상으로 인해 다발성 장기부전, 특히 심장을 침범하는 드문 전신성, 백혈구증식성 질환이다. 심장침범은 특발성 과호산구 증후군 환자의 75% 이상에서 일어난다. 심장증상은 심내막 하 섬유증, 제한성 심근병증, 판막부전, 그리고 말초동맥 혈전증을 유발하는 혈전이다. 이 질환은 남자에서 여자보다 9 : 1로 호발하고, $20{\sim}50$대에서 주로 발현하는 경향이 있으며 소아에서는 매우 드물다. 인공 대동맥판막부전을 나타낸 특발성 과호산구 증후군 환자(58세, 남자)를 인공판막 재치환 수술 후 부신피질호르몬제와 hydroxyurea 투여로 성공적으로 치료하였기에 보고하는 바이다.