Coronary ostium obstruction due to dislodgement of the prosthetic valve is a rare and life-threatening complication, and particular caution is required for sutureless aortic valve replacement (AVR) with concomitant valvular surgery. In general, coronary artery bypass surgery is performed when coronary ostium obstruction occurs after AVR, but other options may need to be considered in some cases. Herein, we present a case of coronary artery occlusion in an 82-year-old female patient who had undergone AVR and mitral valve replacement for aortic valve stenosis and mitral valve stenosis at the age of 77 years. A hybrid procedure involving redo AVR and percutaneous coronary intervention after left main coronary ostium endarterectomy was performed. To summarize, we present a case of hybrid AVR in a patient with coronary artery obstruction after AVR that was successfully managed using this method.
Chang, Sung Wook;Chun, Sangwook;Lee, Gyeongho;Seo, Pil Won
Journal of Chest Surgery
/
v.54
no.5
/
pp.429-432
/
2021
Isolated iliac artery aneurysm (IAA) is rare, but can be fatal. Emergency surgery is performed in cases of hemorrhagic shock due to a suddenly ruptured IAA, which may have a high mortality rate because of massive non-compressible torso hemorrhage (NCTH). Recently, resuscitative endovascular balloon occlusion of the aorta (REBOA) has been accepted as an alternative to aortic cross-clamping via open thoracotomy to achieve hemostasis in trauma patients with profound shock due to NCTH and is considered an emerging bridging therapy for damage control. However, there is limited information on the use of REBOA in non-trauma patients with shock. Herein, we describe a patient with impending cardiac arrest due to isolated ruptured IAA, in whom perioperative bleeding was successfully controlled by REBOA.
A total of 63 patients [42 males and 21 females] underwent multiple valve replacement with artificial valves between January 1975 and August 1980 at Seoul National University Hospital. There were 38 patients with aortic and mitral valve replacement, 22 with mitral and tricuspid, and 3 with aortic, mitral and tricuspid valve replacement. The valve lesions varied from trivial to severe and most aortic and mitral valves had mixed stenosis and insufficiency, while tricuspid valves had only insufficiency. The patients were severely symptomatic in majority of the cases, and belonged to the Classes III and IV [III:45, IV:16] of the NYHA functional criteria. Hemodynamic studies were performed on all the patients. The mean pulmonary wedge pressure was remarkably increased to 19.8 mmHg in aortic and mitral valve lesions and 18.0 mmHg in mitral and tricuspid valve lesions. The mean pulmonary arterial pressure was also increased, while the cardiac index was reduced. In 1977, the average perfusion time was 245.5 minutes for aortic and mitral valve replacement and 181.6 minutes for mitral and tricuspid valve replacement. It has progressively declined to 169.2 minutes for aortic and mitral valve replacement and 123 minutes for mitral and tricuspid valve replacement in 1980. The average period of aortic occlusion also declined after the use of cardioplegic solution. Twenty deaths occurred among the 63 patients operated upon, an overall mortality rate of 30.8%. The operative mortality has declined with successive year from a level of 66.7% before 1977 to 21.1% in 1980. Fourteen patients suffered from a list of postoperative complications, which eventually resolved with adequate treatment. All the survivors were enjoying the levels of daily life activities greater than those existing before the operation.
Cho, JooHyun;Bang, Jung Hee;Jeong, Sang Seok;Yi, Junghoon;Yoon, Sung Sil;Cho, Kwangjo
Journal of Chest Surgery
/
v.53
no.6
/
pp.353-360
/
2020
Background: Most abdominal aortic aneurysms are degenerative atherosclerotic aneurysms. Inflammatory or infected abdominal aortic aneurysms, which show a slightly different clinical course, are rarely encountered in clinical settings. Therefore, we aimed to investigate the clinical course of these variants of abdominal aortic aneurysms. Methods: This retrospective study included 32 patients with atypical inflammatory or infected abdominal aortic aneurysms who underwent emergent graft replacement between November 1997 and December 2017. Patients were followed up at the outpatient clinic for a mean period of 4.9±6.9 years. We analyzed the patients' clinical course and compared it with that of patients with atherosclerotic abdominal aortic aneurysms. Results: There was 1 surgical mortality (3.0%) in a case complicated by aneurysmal free rupture. In 2 cases of infected abdominal aortic aneurysms, anastomotic complications developed immediately postoperatively. During the follow-up period, 10 patients (30%) developed graft complications, and 9 of them underwent reoperations; of these, 2 patients (22.2%) died of postoperative complications after the second operation, whereas 2 patients survived despite graft occlusion. Conclusion: Patients with inflammatory abdominal aneurysms frequently develop postoperative graft complications requiring secondary surgical treatment, so they require close mandatory postoperative follow-up.
Background: Conventional ascending aortic cross clamping is often limited. This study was carried out to evaluate the safety and efficacy of an endovascular aortic clamping technique with an intraaortic balloon catheter. Material and Method: From April 2004 to January 2007, surgery with endoaortic clamping was performed in seven patients. A retrograde access perfusion (RAP) catheter was used in six patients and a Pruitt's balloon catheter in two patients. The indication for the operation was a retrosternal pseudoaneurysm of the aortic root in six patients, diffuse calcification of the ascending aorta with aortic regurgitation in 2 patients and an atrial septal defect in one patient. Five patients had at least two prior cardiac surgeries. Result: Successful insertion of the catheter and endoaortic clamping was achieved in all patients. Conclusion: The endovascular aortic clamping technique with a balloon catheter was a useful alternative method for patients in whom conventional cardiac surgery was limited.
Background: Achieving external access to and manual occlusion of the left atrial appendage (LAA) during minimally invasive mitral valve surgery (MIMVS) through a small right thoracotomy is difficult. Occlusion of the LAA using an epicardial closure device seems quite useful compared to other surgical techniques. Methods: Fourteen patients with atrial fibrillation underwent MIMVS with concomitant surgical occlusion of the LAA using double-layered endocardial closure stitches (n=6, endocardial suture group) or the AtriClip Pro closure device (n=8, AtriClip group) at our institution. The primary safety endpoint was any device-related adverse event, and the primary efficacy endpoint was successful complete occlusion of blood flow into the LAA as assessed by transthoracic echocardiography at hospital discharge. The primary efficacy endpoint for stroke reduction was the occurrence of ischemic or hemorrhagic neurologic events. Results: All patients underwent LAA occlusion as scheduled. The cardiopulmonary bypass and aortic cross-clamp times in the endocardial suture group and the AtriClip group were 202±39 and 128±41 minutes, and 213±53 and 136±44 minutes, respectively (p=0.68, p=0.73). No patients in either group experienced any device-related serious adverse events, incomplete LAA occlusion, early postoperative stroke, or neurologic complication. Conclusion: Epicardial LAA occlusion using the AtriClip Pro during MIMVS in patients with mitral valve disease and atrial fibrillation is a simple, safe, and effective adjunctive procedure.
매우 드물게 발생하지만 대동맥판막수술중에 우관상동맥의 급성폐색은 우심실부전을 일으켜 매우 치명적인 결과를 초래할 수 있다. 심한 대동맥 판막부전증을 가진 67세 여자 환자에서 19 mm Hancock II 조직판막을 이용하여 대동맥판막치환술을 시행한 후 심폐기에서 이탈하는 과정주에 우심실부전이 발견되었으며, 우관상 동맥의 폐색을 의심하여 우측 내흉동맥을 사용하여 관상동맥 우회수술을 시행하였고 이후에 심폐기에서 순조롭게 이탈할 수 있었다. 수술후 9일째 시행한 관상동맥 조영술에서 우관상동맥 근위부에 색전에 의한 폐색을 확인할 수 있었다. 이에 저자들은 우관상동맥의 폐색으로 인한 우심부전증이 우관상동맥우회수술후에 회복된 증례를 보고하고자 한다.
Takayasu`s arteritis is a non-specific arteritis involving the aorta and its major branches. Because of the complexity in the feature of vessel involvement, it represents various clinical presentations according to the sites of involvement. In general, the medical and the surgical treatment of this progressive disease are known to be unsatisfactory but the surgical treatment can provide symptomatic relief and prolong life in selected cases. Recently we experienced one case of Takayasu`s arteritis involving the aortic arch and its major branches. A 45 year-old male patient admitted with the complaints of dizziness, headache, visual disturbance and coldness of upper extremities. Ascending aortogram revealed total occlusion of innominate artery and near total occlusion of left common carotid artery at the site of origin of both vessels. Under the clinical diagnosis of Takayasu`s arteritis, aorto-bicarotid-right subclavian bypass was performed. Postoperative course was uneventful and most of symptoms were relieved except mild residual visual disturbance.
Takayasu arteritis (TA) is a chronic inflammatory disease of unknown etiology that affects mainly the aorta, main aortic branches, and pulmonary arteries. Diverse neurological manifestations of TA have rarely been reported in children. Posterior reversible encephalopathy syndrome (PRES) is a neuroradiological condition that presents with headache, seizure, visual disturbances, and characteristic lesions on imaging. Inflammatory condition and severe hypertension in TA can cause PRES. We report of a 5-year-old girl with presumed TA who presented with PRES and chronic total occlusion in the renal artery. The findings on magnetic resonance imaging suggested PRES. Left nephrectomy was performed for total occlusion of the left renal artery, and the confirmatory diagnosis of TA was based on the pathologic findings of the renal artery.
Yu, Byungchul;Lee, Gil Jae;Choi, Kang Kook;Lee, Min A;Gwak, Jihun;Park, Youngeun;Lee, Jung Nam
Journal of Trauma and Injury
/
v.33
no.3
/
pp.162-169
/
2020
Purpose: There is increasing evidence in the literature regarding resuscitative endovascular balloon occlusion of the aorta (REBOA) globally, but few cases have been reported in Korea. We aimed to describe our experience of successful Zone III REBOA and to discuss its algorithm, techniques, and related complications. Methods: We reviewed consecutive cases who survived from hypovolemic shock after Zone III REBOA placement for 4 years. We reviewed patients' baseline characteristics, physiological status, procedural data, and outcomes. Results: REBOA was performed in 44 patients during the study period, including 10 patients (22.7%) who underwent Zone III REBOA, of whom seven (70%) survived. Only one patient was injured by a penetrating mechanism and survived after cardiopulmonary resuscitation. All patients underwent interventions to stop bleeding immediately after REBOA placement. Conclusions: This case series suggests that Zone III REBOA is a safe and feasible procedure that could be applied to traumatic shock patients with normal FAST findings who receive a chest X-ray examination at the initial resuscitation.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.