• 제목/요약/키워드: Aortic bypass surgery

Search Result 371, Processing Time 0.021 seconds

Aortic Surgery without Infusion of Cardioplegic Solution at Total Circulatory Arrest

  • Lee, Hae Young;Kim, Dong Jin
    • Journal of Chest Surgery
    • /
    • v.46 no.1
    • /
    • pp.27-32
    • /
    • 2013
  • Background: Minimal infusion of cardioplegic solution (CPS) during aortic surgery using total circulatory arrest (TCA) may reduce several potential side effects: clamping on a diseased aorta, insult of coronary ostia, and edema. Materials and Methods: From 2006 to 2009, 72 patients underwent aortic surgery without infusion of cardioplegic solution at the initiation of circulatory arrest. The diagnoses were acute aortic dissection (44), aneurysm (22), and intramural hematoma (6). Results: The duration of TCA, the lowest nasopharyngeal temperature, bypass time, and aortic clamp time was 45 minutes, $16.4^{\circ}C$, 162 minutes, and 100 minutes, respectively. The amount of CPS was 1,050 mL, and 15 patients underwent surgery without CPS. The average inotrope score was 113 points (range, 6.25 to 5,048.5 points) corresponding to the dopamine infusion of 5 mcg/kg/min for 1 day. Seven patients showed a level of creatine kinase-MB above 50 ng/mL, postoperatively, compared with the average of 12.75 ng/mL. The ischemic change was found on electrocardiogram in 5 patients, postoperatively. There was no cardiac morbidity requiring mechanical assist. The average of intensive care unit stay and postoperative hospital stay was 40 hours (range, 15 to 482 hours) and 11 days, respectively. Conclusion: Minimal infusion of only retrograde CPS during rewarming without initial infusion at TCA in aortic surgery is feasible and can be used with acceptable results.

Short-term Outcomes of Aortic Wrapping for Mild to Moderate Ascending Aorta Dilatation in Patients Undergoing Cardiac Surgery

  • Park, Ji-Young;Shin, Je-Kyoun;Chung, Jin-Woo;Kim, Jun-Seok;Chee, Hyun-Keun;Song, Meong-Gun
    • Journal of Chest Surgery
    • /
    • v.45 no.3
    • /
    • pp.148-154
    • /
    • 2012
  • Background: The adequate management of mild to moderate dilatation of the ascending aorta during cardiac operations remains controversial. In this study, we present the short-term outcomes of 90 patients undergoing ascending aortic wrapping with a Dacron graft during other cardiac operations. Materials and Methods: From March 2008 to January 2011, 90 consecutive patients underwent treatment for ascending aortic aneurysm using the external wrapping technique during the concomitant procedure. The study group consisted of 49 male and 41 female patients with a mean age of $58.7{\pm}13$years. The primary cardiac surgical procedures were coronary artery bypass grafting (CABG) in 3, aortic valve replacement in 2, and aortic valvuloplasty in 85 patients (isolated in 62 and combined with CABG or mitral valvuloplasty in 23). The ascending aorta diameter was measured using a computed tomography scan within 4 weeks after surgery, and was compared with the preoperative value. Results: The diameters of the ascending aorta wrapped with the Dacron graft were significantly reduced within a month after surgery from $46.4{\pm}4.3$ mm to $33.0{\pm}3.5$ mm (p<0.05). There was no early mortality or major surgical complication. During the mean follow-up period of $15.4{\pm}5.2$ months, there was only one late death caused by septic multiorgan failure. Conclusion: Dacron wrapping of the ascending aorta offers excellent results with very low mortality and morbidity, and it can be regarded as a safe and effective method for the treatment of moderately dilated ascending aorta in selected patients.

An Aortic Dissection in Pregnant Woman -a case report- (임산부에서 발생한 대동맥 박리 (Aortic Dissection) 1례)

  • Lee, Hyeong-Min;Hong, Eun-Pyo;Lee, Dong-Hyup;Lee, Jung-Cheul;Han, Sung-Sae;Sin, Dong-Gu;Kim, Young-Jo;Shim, Bong-Sup
    • Journal of Yeungnam Medical Science
    • /
    • v.10 no.1
    • /
    • pp.253-259
    • /
    • 1993
  • We have experienced a case of aortic dissecting aneurysm in pregnant woman. She felt initially severe chest pain which was radiated to the neck on the 3days before delivery. Thereafter dyspnea and generalized edema were developed for 1 month after delivery. She was diagnosed as aortic dissection, Debakey typeII. During cardiopulmonary bypass, the selective cerebral perfusion was done through the right and left commom carotid arteries. Aortic replacement with Hemashield vascular graft and reimplantation of innominate artery, resuspension of aortic valve, repair of intimal tear were performed. The postoperative course was uneventful.

  • PDF

Srugical treatment of aortic arch syndrome -Two cases report- (대동맥궁 증후군의 수술치료 -2례 보고-)

  • 채성수
    • Journal of Chest Surgery
    • /
    • v.16 no.2
    • /
    • pp.170-174
    • /
    • 1983
  • Aortic arch syndrome is an unusual disease entity characterized by the narrowing or obliteration of major branches of the arch of the aorta regardless of etiology. We have experienced 2 cases. One of them was 22 years old office girl with 3 months history of headache, intermittent syncope and weakness and claudication on left arm especially during her physical exercise. On physical examination, pulseless on left antecubital and radial artery and blood pressure on left arm was inable to check and coldness with weakness were noted on the same side. Aortic angiography reealed 34% narrowing of left subclavian artery as that of right. But both common carotid artery and both axillary arterial patency were relatively good. Through right supraclavicular and left axillary incision, bypass graft with Gore-tex prosthesis (I.D. 6mm, Length 25 cm) was implanted from right subclavian artery on 2cm distal to origin of right common carotid arery to left axillary artery distal to axillary fossa. End to side anastomosis with preservation of left subclavian artery was done. Postoperative state was stable with blood pressure of 110/70 mmHg on left arm and palpable antecubital and radial pulsation. Another one was 41 year old male patient with 8 months history of pain and numbness on right upper arm and shoulder. On admission, right arm blood pressure was 110/80 mmHg, left arm was 160/110 mmHg, but other physical findings had no abnormalities. Angiography revealed segmental narrowing of right axillary artery on the beginning with 2 cm in length. Operative treatment with right wupraclavicular and right axillary incision, bypass graft with great saphenous vein (Length; 15 cm) from right subclavian artery between scalenus anticus and medius to axillary artery at distal end of axillary fossa was done. The authors report two cases of Aortic arch syndrome treated with bypass graft using Autograft or Gore-tex with good result.

  • PDF

Early and Midterm Results of Hybrid Endovascular Repair for Thoracic Aortic Disease (흉부대동맥 질환에서 시행된 하이브리드 혈관내 성형술의 중단기 성적)

  • Youn, Young-Nam;Kim, Kwan-Wook;Hong, Soon-Chang;Lee, Sak;Chang, Byung-Chul;Song, Seung-Jun
    • Journal of Chest Surgery
    • /
    • v.43 no.5
    • /
    • pp.490-498
    • /
    • 2010
  • Background: A hybrid procedure using an open surgical extra-anatomic bypass of aortic arch vessels and thoracic endovascular aortic repair (TEVAR) is less invasive than open surgery, and provides a suitable proximal landing zone. Here we report our experience with a hybrid TEVAR procedure at a single center. Material and Method: We retrospectively reviewed consecutive patients with thoracic aortic disease who received a hybrid TEVAR procedure between August 2008 and January 2010. Patients' data were prospectively collected and mean follow-up was $10.8{\pm}5.5$ months (range 3~20). Result: Nine patients (7 males and 2 females) with a mean age of $63.8{\pm}15.8$ years (range 38~84) underwent a hybrid procedure. Five patients had an arch or a proximal descending aortic aneurysm, two had a dissecting aneurysm of the descending aorta, and two had an aneurysm of the ascending arch and descending aorta. Mean expected mortality calculated by logistic EuroSCORE was 21%. Six patients underwent debranching and rerouting from ascending aorta to arch vessels, 2 had carotid-carotid bypass grafting, and 1 underwent carotid-axillary bypass grafting. Mean operation time was $221.4{\pm}84.0$ min (range 94~364). Deployment success of endovascular stent grafting was 100% with no endoleak on completion angiography. There was no mortality, and a small embolism in the branch of the right opthalmic artery in one patient. During follow-up, one intervention was required for the endoleak. Actuarial survival at 20 months was 100%. Conclusion: Early and mid-term results are encouraging and suggest that hybrid TEVAR procedures are less invasive and safer and represent an effective technique for treating thoracic aortic disease.

Cabrol Technique Application in Off-pump Coronary Artery Bypass Grafting Using Radial Artery (인공심폐기를 이용하지 않는 관상동맥우회술 시 요골동맥을 이용한 Cabrol 술식의 응용)

  • Na, Chan-Young;Oh, Sam-Se;Kim, Soo-Cheol;Kim, Jae-Hyun;Jo, Won-Min;Seo, Hong-Ju;Lee, Cheul;Chang, Yun-Hee;Kang, Chang-Hyun;Lim, Cheong;Baek, Man-Jong;Whang, Song-Wok;Choi, In-Seok;Kim, Woong-Han;Park, Yoon-Ock;Moon, Hyun-Soo;Park, Young-Kwang;Kim, Chong-Whan
    • Journal of Chest Surgery
    • /
    • v.36 no.8
    • /
    • pp.630-632
    • /
    • 2003
  • In off-pump coronary artery bypass grafting (CABG), multiple proximal anastomosis may increase the risk of cerebral embolism (air, debris) and aortic injury (dissection, pseudoaneurysm). Radial artery (RA) has no intraluminal valve such as saphenous vein. We applied Cabrol technique using aortic root replacement for proximal anastomosis in off-pump CABG. Cabrol technique using RA graft can reduce numbers of proximal anastomosis and reduce number of aortic manipulation in off-pump CABG. We report a Cabrol technique for proximal anastomosis in off-pump CABG with RA graft.

A Case of Total Aortic Arch Replacement with Root Plasty with Right Coronary Artery Bypass and Distal Open Stent-graft Insertion in Acute Type I Aortic Dissection (급성대동맥박리중에서 전궁치환술 시 근부성형술 및 우관상동맥우회로술과 하행대동맥 내 스텐트인조혈관삽입 동시 시술 증례)

  • Bang Jung Hee;Woo Jong Su;Kim Si Ho;Choi Pil Jo;Cho Kwang Jo
    • Journal of Chest Surgery
    • /
    • v.38 no.6 s.251
    • /
    • pp.434-437
    • /
    • 2005
  • Since the operative mortality rate of the Acute aortic dissection has been reducing, a more extensive primary repair of the dissected aorta is preferred for acute aortic dissection to reduce the needs of secondary procedures. We performed a total aortic arch replacement with distal stent-grafting in acute type A aortic dissection. The patient was a 50-years old man. He recovered from the operation and was followed up for 7 months. The pseudolumen in the descending aorta was obliterated with the stent.

Intracardiac a Aortic Foreign Body (심장 및 대동맥내 이물 치험 1례)

  • 방정희;편승환
    • Journal of Chest Surgery
    • /
    • v.30 no.9
    • /
    • pp.932-935
    • /
    • 1997
  • A 50-year-old male patient was admitted due to right ventricular & aortic foreign bodies with ascending aortic pseudoaneurysm. The patient had a history of Kirschner wire fixation of right sternoclavicular joint 3 months ago. Under cardiopulmonary bypass, two K-wires were removed and injured pulmonary valve leaflet and aortic wall were repaired successfully The postoperative course was uneventful and the patient was discharged on the 14th postoperative day.

  • PDF

Traumatic Aneurysm of Descending Thoracic Aorta -A Case Report- (외상성 하행 흉부 대동맥류 -치험 1 례 보고-)

  • 임승현
    • Journal of Chest Surgery
    • /
    • v.27 no.12
    • /
    • pp.1042-1046
    • /
    • 1994
  • We experienced a case of traumatic aneurysm of descending thoracic aorta by an automobile accident. The patient was 23-year-old-male with a traumatic aortic aneurysm [6x12cm] on the descending thoracic aorta just distal to the origin of the left subclavian artery. Exposure was obtained through a left posterolateral thoracotomy incision in the fourth intercostal space and then partial femoro-femoral cardiopulmonary bypass was established.After aortic cross- clamping, the aneurysmal sac was opened and repaired with interposition of Dacron vascular graft and aortic cross-clamping period lasted for 100 minutes. Postoperative bleeding and vocal cord paralysis were complicated, but bleeding was controlled by reoperation and vocal cord paralysis was improved. Follow up was continued for 14months and postoperative course was uneventful.

  • PDF

Thoracoabdominal Aortic Aneurysm Repair after Renal Transplantation (신장 이식후 발생한 해리성 흉복부 대동맥류의 외과적 치험)

  • 김대영;문광덕
    • Journal of Chest Surgery
    • /
    • v.29 no.4
    • /
    • pp.449-453
    • /
    • 1996
  • A successful resection of dissecting thoracoabdominal aortic aneurysm is presented in a patient who had undergone kidney transplantation 20 months previously. Because the transplanted kidney is more sensitive to ischemia than the normal kidney, a femoro-femoral bypass with a pump oxygenator was used for perfusion of the transplanted kidney during crossclamping. During the clamping time of 1)8 minutes, kidney perfusion was maintai ed with a perfusion pressure of (19 to 31) 27mmHg and the flow was 0.53 to 0.81 L/min. 32mm sized Hemashield (22 Cm in length) was interposed. The postoperative course was uncomplicated. We believe that performing the femoro- femoral bypass with a pump oxygenator is an effective and simple method for renal and spinal protection in such operations.

  • PDF