• Title/Summary/Keyword: Aorta valve

Search Result 166, Processing Time 0.026 seconds

Robot-Assisted Cardiac Surgery Using the Da Vinci Surgical System: A Single Center Experience

  • Kim, Eung Re;Lim, Cheong;Kim, Dong Jin;Kim, Jun Sung;Park, Kay Hyun
    • Journal of Chest Surgery
    • /
    • v.48 no.2
    • /
    • pp.99-104
    • /
    • 2015
  • Background: We report our initial experiences of robot-assisted cardiac surgery using the da Vinci Surgical System. Methods: Between February 2010 and March 2014, 50 consecutive patients underwent minimally invasive robot-assisted cardiac surgery. Results: Robot-assisted cardiac surgery was employed in two cases of minimally invasive direct coronary artery bypass, 17 cases of mitral valve repair, 10 cases of cardiac myxoma removal, 20 cases of atrial septal defect repair, and one isolated CryoMaze procedure. Average cardiopulmonary bypass time and average aorta cross-clamping time were $194.8{\pm}48.6$ minutes and $126.1{\pm}22.6$ minutes in mitral valve repair operations and $132.0{\pm}32.0$ minutes and $76.1{\pm}23.1$ minutes in myxoma removal operations, respectively. During atrial septal defect closure operations, the average cardiopulmonary bypass time was $128.3{\pm}43.1$ minutes. The median length of stay was between five and seven days. The only complication was that one patient needed reoperation to address bleeding. There were no hospital mortalities. Conclusion: Robot-assisted cardiac surgery is safe and effective for mitral valve repair, atrial septal defect closure, and cardiac myxoma removal surgery. Reducing operative time depends heavily on the experience of the entire robotic surgical team.

Numerical Study on the Pulsatile Blood Flow through a Bileaflet Mechanical Heart Valve and Leaflet Behavior Using Fluid-Structure Interaction (FSI) Technique (유체-고체 상호작용 (FSI)기법을 이용한 이엽기계식 인공심장판막을 지나는 혈액유동과 판첨거동에 관한 수치해석적 연구)

  • Choi, Choeng-Ryul;Kim, Chang-Nyung
    • The KSFM Journal of Fluid Machinery
    • /
    • v.7 no.3 s.24
    • /
    • pp.14-22
    • /
    • 2004
  • Bileaflet mechanical valves have the complications such as hemolysis and thromboembolism, leaflet damage, and leaflet break. These complications are related with the fluid velocity and shear stress characteristics of mechanical heart valves. The first aim of the current study is to introduce fluid-structure interaction method for calculation of unsteady and three-dimensional blood flow through bileaflet valve and leaflet behavior interacted with its flow, and to overcome the shortness of the previous studies, where the leaflet motion has been ignored or simplified, by using FSI method. A finite volume computational fluid dynamics code and a finite element structure dynamics code have been used concurrently to solve the flow and structure equations, respectively, to investigate the interaction between the blood flow and leaflet. As a result, it is observed that the leaflet is closing very slowly at the first stage of processing but it goes too fast at the last stage. And the results noted that the low pressure is formed behind leaflet to make the cavitation because of closing velocity three times faster than opening velocity. Also it is observed some fluttering phenomenon when the leaflet is completely opened. And the rebounce phenomenon due to the sudden pressure change of before and after the leaflet just before closing completely. The some of time-delay is presented between the inversion point of ventricle and aorta pressure and closing point of leaflet. The shear stress is bigger and the time of exposure is longer when the flow rate is maximum. So it is concluded that the distribution of shear stress at complete opening stage has big effect on the blood damage, and that the low-pressure region appeared behind leaflet at complete closing stage has also effect on the blood damage.

Estimation of Blood Pressure Diagnostic Methods by using the Four Elements Blood Pressure Model Simulating Aortic Wave Reflection (대동맥 반사파를 재현한 4 element 대동맥 혈압 모델을 이용한 혈압 기반 진단 기술의 평가)

  • Choi, Seong Wook
    • Journal of Biomedical Engineering Research
    • /
    • v.36 no.5
    • /
    • pp.183-190
    • /
    • 2015
  • Invasive blood pressure (IBP) is measured for the patient's real time arterial pressure (ABP) to monitor the critical abrupt disorders of the cardiovascular system. It can be used for the estimation of cardiac output and the opening and closing time detection of the aortic valve. Although the unexplained inflections on ABP make it difficult to find the mathematical relations with other cardiovascular parameters, the estimations based on ABP for other data have been accepted as useful methods as they had been verified with the statistical results among vast patient data. Previous windkessel models were composed with systemic resistance and vascular compliance and they were successful at explaining the average systolic and diastolic values of ABP simply. Although it is well-known that the blood pressure reflection from peripheral arteries causes complex inflection on ABP, previous models do not contain any elements of the reflections because of the complexity of peripheral arteries' shapes. In this study, to simulate a reflection wave of blood pressure, a new mathematical model was designed with four elements that were the impedance of aorta, the compliance of aortic arch, the peripheral resistance, and the compliance of peripheral arteries. The parameters of the new model were adjusted to have three types of arterial blood pressure waveform that were measured from a patient. It was used to find the relations between the inflections and other cardiovascular parameters such as the opening-closing time of aortic valve and the cardiac output. It showed that the blood pressure reflection can bring wide range errors to the closing time of aortic valve and cardiac output with the conventional estimation based on ABP and that the changes of one-stroke volumes can be easily detected with previous estimation while the changes of heart rate can bring some error caused by unexpected reflections.

Successful Surgical Correction of Complete Transposition of Great Arteries (S.D.D.) : 1 Case Report (Rastelli씨 수술법을 이용한 완전 대혈관전위증(S. D. D.) -치험 1예-)

  • Kang, Myung-Sik;Cho, Bum-Koo
    • Journal of Chest Surgery
    • /
    • v.13 no.4
    • /
    • pp.442-447
    • /
    • 1980
  • A 8-year-old boy underwent surgical correction of complete transposition S.D.D. of great arteries combined with subaortic ventricular septal defect and pulmonary stenosis [infundibular and valvular]. The operation consisted of an internal baffling connecting the left ventricle to the aorta through the ventricular septal defect. The pulmonary stenosis was corrected with the method of external connection, the right ventricle to the pulmonary artery using the conduit valve [20 mm] contained Hancock due to abnormal distribution of left coronary artery of which conduit due to abnormal distribution of left coronary artery of which the circumflex branch crossed the portion of right ventricular outflow tract. This case was suitable for corrective surgery-Rastelli operation-and the patient`s condition in very good until present [post-operative 5 months].

  • PDF

Modified Anatomic Repair of Corrected Transposition of the Great Arteries with Ventricular Septal Defect and Pulmonary Outflow Obstruction (심실중격결손과 폐동맥유출로 협착을 동반한 교정형 대혈관전위증의 해부학적 교정수술)

  • 박계현
    • Journal of Chest Surgery
    • /
    • v.24 no.11
    • /
    • pp.1149-1153
    • /
    • 1991
  • A modified procedure for the operative management of the corrected transposition of the great arteries with ventricular septal defect and pulmonary stenosis or atresia was performed in 4 patients. (age ; 18 months-9 years). The operation consists of a venous switch procedure (Senning), intraventricular baffling directing the blood flow from the morphologic left ventricle into the aorta via ventricular septal defect through the right ventriculotomy, and insertion of valved conduit between the morphologic right ventricle and the pulmonary artery. All the four patients had large non-restrictive ventriular septal defects and no evidence of significant mitral valve regurgitation. Both ventricles were well-developed. Three cases had pulmonary atresia, and the remainder had severe subpulmonic stenosis. Postperatively, all patients showed no findings of systemic or pulmonary venous obstruction withnormal sinus rhythm. One patient died of sepsis due to infection by Methicillin-resistant S. aureus on the thirteenth postoperative day. Follow-up is done on the survivors, and all of them are dong well with regular sinus rhythm, with their functional class I or II at 2 to 8 months after the operation.

  • PDF

Surgical Management of Aortic Insufficiency in Behcet`s Syndrome - An Experience of 8 Cases - (Behcet 씨 증후군에 의한 대동맥판 폐쇄부전의 수술치험 -3례 보고-)

  • 원용순
    • Journal of Chest Surgery
    • /
    • v.21 no.5
    • /
    • pp.899-904
    • /
    • 1988
  • In Behcet syndrome, cardiac involvements are rare and have been reported pericarditis, myocarditis, right heart endocardial fibrosis, right ventricle mural thrombus with pulmonary embolism, active endocarditis, granulomatous endocarditis, conduction disturbance, acute aortic insufficiency, mitral valve prolapse. Our three patients underwent AVR because of aortic insufficiency and ascending aorta enlargement combined with Behcet syndrome. Two patients had mitral regurgitation too. So one underwent MAP and the other underwent MVR concomitantly. One who underwent AVR have been well for 50 months. Another who underwent AVR+MAP and redo AVR due to aortic paravalvular leakage was died of congestive heart failure. The other who underwent AVR+MVR and repeated AVR three times because of aortic paravalvular leakage is in condition of aortic paravalvular leakage. Paravalvular leakage is considered to recur due to progressive dilatation and fragility of aortic root that is the result of pathologic change of Behcet syndrome in it. If Open heart surgery is needed in Behcet`s syndrome during inflammatory reaction is active, postoperative complications such as paravalvular leakage or suture line rupture may be prevented with pre- and postoperative anti-inflammatory management.

  • PDF

Congenital Aortic Stenosis: Report of 2 Cases (선천성 대동맥 판막 협착증 치험 2예)

  • 송명근
    • Journal of Chest Surgery
    • /
    • v.11 no.2
    • /
    • pp.194-198
    • /
    • 1978
  • Congenital aortic stenosis, a relatively uncommon congenital heart disease, may cause heart failure and may be fatal. In recent years, increased clinical awareness and improved diagnostic and operative technique has made accurate diagnosis and successful treatment possible. Recently we experienced 2 cases of congenital aortic stenosis, and which was corrected surgically. The first case was 9 years old boy, and second case was 16 years male. Preoperative diagnosis was entertained by angiography and cardiac catheterization in both cases. In each case, aortic valve opening was widened by incision along the fused commissure between the combined left and right coronary cusp on one side, and the noncoronary cusp on the other side. Post-op. pressure gradient between the aorta and left ventricle markedly reduced, in the first case, 50mmHg, and in the 2nd case, 55mmHg.Both patients discharged with good results 2 weeks after open heart surgery.

  • PDF

Double Outlet Left Ventricle - One Case Report - (양대동맥 좌심실기시증치험 1례)

  • 성후식
    • Journal of Chest Surgery
    • /
    • v.20 no.4
    • /
    • pp.798-802
    • /
    • 1987
  • Origin of both great vessels from morphological left ventricle [DOLV] is a rare cardiac anomaly which embryologic possibility has been explained by differential conal development concept and differential canal absorption concept. Recently we had surgical experience of DOLV in 4 month-age infant weighing 5.7Kg. The chief complaints on admission were cyanosis and anoxic spell during severe crying, and right heart catheterization and right ventriculogram were performed but incorrect diagnosis was made. The operative procedures were ligation of patent ductus arteriosus, patch closure of subaortic VSD aligning aorta and pulmonary artery with left ventricle, suture closure of proximal pulmonary artery and valve and the use of extracardiac valved conduit [Carpentier-Edward l4mm] from right ventricle to distal pulmonary artery. Postoperative course was uneventful and discharged in the good condition.

  • PDF

Subaortic Stenosis in Dogs. (개의 대동맥협착증)

  • 허진영;최지혜;최호정;이희천;이영원;박수원;엄기동;한정희;윤화영
    • Journal of Veterinary Clinics
    • /
    • v.16 no.2
    • /
    • pp.523-528
    • /
    • 1999
  • Subaortic stenosis in a 2.9kg, 3-month-old pug dog and a 11 kg, 4-month-old Rott -weiler dog showing signs of dyspnea, tachypnea, anorexia, exercise intolerance and depression was diagnosed with electrocardiography, thoracic radiography and ultrasonographic evaluation. In electrocardiography, PR interval widening, R wave amplitude increase in lead II in case 2, ST segment depression and left axis deviation in case 1 and 2 were identified. In thoracic radiographs, enlarged left ventricle and atrium, caudal displacement of left crus of diaphragm and caudal part of cranial mediastinum widening were identified in ventrodorsal view. In lateral view, left ventricular enlargement, secondary dorsal deviation of trachea and post-stenotic dilation of aorta were seen. Also, edematous pulmonary changes were shown in peri-hilar area. In ultrasonographic examination, left ventricular dilatation, pericardial effusion and subaortic valvular ridge were seen with real time B-mode in right parasternal long axis view. Aortic valve regurgitation was identified in color-Doppler mode.

  • PDF

Isolated Ventricular Inversion and Anatomically Corrected Malposition of the Great Arteries Associated with Right Juxtaposition of Left Atrial Appendage: A case of Successful surgical repair

  • 이정렬
    • Journal of Chest Surgery
    • /
    • v.23 no.6
    • /
    • pp.1280-1287
    • /
    • 1990
  • A seven month old female infant with isolated ventricular inversion and anatomically corrected malposition of the great arteries in situs solitus, associated with ventricular septal defect, patent ductus arteriosus, right-sided juxtaposition of left atrial appendage, is reported. The patient showed usual atrial arrangement with somewhat superoinferior relation, a discordant atrioventricular connection, and a concordant ventriculoarterial connection with aorta in the right-sided position. A normal sized left atrium was connected to the left superiorly positioned morphologic right ventricle through a tricuspid valve, which crossed the left ventricular outflow tract anteriorly. Well developed bilateral[subaortic and sub-pulmonary]conus was documented at operative field. successful surgical repair was done by performing the Senning procedure and by closing the ventricular sepal defect with a patch through the right ventriculotomy. The infant’s postoperative course was uneventful with normal sinus rhythm. Postoperative cardiac catheterization revealed no hemodynamic obstruction or residual shunt.

  • PDF