• Title/Summary/Keyword: Anti-vibration gloves Hand-transmitted vibration

Search Result 6, Processing Time 0.024 seconds

Assessment of Anti-vibration Gloves for Reduction of Hand-transmitted Vibration Exposure (수전달 진동 피폭 저감을 위한 방진 장갑의 성능 평가)

  • Choi, Seok Hyun;Hong, Seok In;Jang, Han Kee
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.18 no.1
    • /
    • pp.1-10
    • /
    • 2008
  • In order to evaluate performance of anti-vibration gloves, it is necessary to measure the transmitted vibration to the hand and the applied forces at the same time while gripping the vibrating handle. In the study a system was developed to measure both the vibration and the forces. The system consists of a measurement handle with eight strain gauges and two accelerometers and a PC-based system with a software for signal processing, evaluation of the hand-transmitted vibration and for control of applied forces in the pre-determined range. The handle was installed on the vibration shaker which is strong enough so as not to be affected by dynamic coupling with the hand-arm. Whole procedure of ISO 10819:1996 to determine the vibration transmissibility of anti-vibration gloves was programmed into the system. As an example of the application, three subjects joined the test to get vibration transmissibilities of 9 anti-vibration gloves where each glove was tested twice a subject. Average and standard deviation of the corrected vibration transmissibility were also calculated. All tested gloves fulfilled criterion for M-spectrum($\overline{TR_M}$<1.0), but one glove fulfilled criterion for H-spectrum($\overline{TR_H}$<6.0),

Development of the System for Measurement of the Vibration Transmissibility of an Anti-vibration Glove (방진 장갑 진동 전달률 측정 시스템 개발)

  • Choi, Seok-Hyun;Hong, Seok-In;Jang, Han-Kee;Park, Tae-Won
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.6 s.111
    • /
    • pp.602-608
    • /
    • 2006
  • In order to evaluate performance of anti-vibration gloves, it is necessary to measure the transmitted vibration to the hand and the applied forces at the same time while gripping the vibrating handle. In the study a system was developed to measure both the vibration and the forces. The system consists of a measurement handle with eight strain gauges and two accelerometers and a PC-based system with a software for signal processing and evaluation of the hand-transmitted vibration and for control of applied forces in the pre-determined range. The handle was installed on the vibration shaker which is strong enough so as not to be affected by dynamic coupling with the hand-arm system. Whole procedure of ISO 10819 to determine the vibration transmissibility of anti-vibration gloves was programmed into the system. As an example of the application, three subjects joined the test to get vibration transmissibilities of anti-vibration gloves where each glove was tested twice a subject. Average and standard deviation of vibration transmissibility were also calculated.

Analysis and Isolation of Walking-type Cultivator Vibration Transmitted to Operator′s Hands (손으로 전달된 관리기 진동의 분석과 방진대책)

  • 박영준;김경욱
    • Journal of Biosystems Engineering
    • /
    • v.27 no.4
    • /
    • pp.273-282
    • /
    • 2002
  • This study was intended to measure and analyze hand-transmitted vibrations from cultivator in idle and operation modes for three different types of field works. Based on this analysis a time for the white finger syndrome to appear on 10% of the operators was estimated assuming that their daily exposure is 3 hours. The 4 methods to reduce the hand vibration were also proposed and compared with each other. The results of the study were summarized as follows : The highest vibration level was recorded during trenching operation, resulting in a total average vibration of 11.5 m/s$^2$. Followings were 7.6 m/s$^2$ during rotary tillage and 7.0 m/s$^2$ for weeding. When exposed to these levels of vibrations three hours a day, the white finger syndrome is likely to appear in 4 years for trenching, 6.2 years for rotary tillage and 6.8 years for weeding operations. Isolation of hand vibration performed by a rubber pad, anti-vibration gloves, a handle anti-vibration device and engine mounts were respectively 15.7%, 16.5%. 26.1% and 27.0%, resulting in most effective methods of the handle anti-vibration device and engine mounts. A better performance of about 33.9% was achieved when both the handle anti-vibration device and engine mounts were used.

Measurement of Grip and Feed Force in the Evaluation of Hand-arm Vibration (수완계 진동 평가에 영향을 미치는 작용력의 측정)

  • 최석현;장한기
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.1038-1042
    • /
    • 2003
  • In order to evaluate dynamic impedance of a hand-arm system it is necessary to measure the hand-transmitted vibration and the reaction force at the same time while gripping the vibrating handle. In the study a device was developed to measure both the vibration and the force. The device consists of a measurement handle with four strain gauge and two accelerometers and a PC based control system with a program for the signal processing and evaluation of the hand-transmitted vibration and reaction force. The handle was installed on the vibration shaker so that it can move by the generated signal from the control system. As an application of the system dynamic reaction force and the frequency weighted acceleration at the handle attached to the shaker were measured at various grip force and feed force. This system will be very useful in the area of impedance measurement and the evaluation of performance of anti-vibration gloves.

  • PDF

Measurement and Assessment of Hand-arm Vibration due to Grinders (그라인딩 작업에 의한 수완계 진동 계측 및 평가)

  • 이종문;박진화
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.1032-1037
    • /
    • 2003
  • This work measured the hand-transmitted vibration due to shipyard worker's grinding and assessed the vibration exposure for predicted 10% prevalence of vibration-induced white finger in a group of exposed persons according to test procedure of ISO 5349-1. And also the transmissibility performance of resilient material, mainly applied to anti-vibration gloves in present market was measured on the basis of ISO 13753 and confirmed that the material would Probably not provide greater attenuation below 30㎐, the dominant frequency range of hand-transmitted vibration due to grinder.

  • PDF

Estimation of Anti-vibration Glove Performance Considering the Vibration Characteristic of Power Tool through Development of Flexible Palm Adapter (Flexible Palm 어댑터의 개발을 통한 동력 공구의 진동 특성을 고려한 방진장갑의 성능 평가)

  • Song, Chi-Mun;Jang, Han-Kee;Hong, Seok-In;Chai, Jang-Bom
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.2
    • /
    • pp.217-224
    • /
    • 2009
  • This study aims to show the guideline to select optimal anti-vibration gloves for specific power tools to prevent hazardous vibration to human body. It is most desirable for the correct evaluation of handtransmitted vibration form the power tool handle to measure the acceleration between the handle surface and the hand palm as recommended in ISO 5349-1. First, the accurate acceleration measurement device was developed of which the thickness and weight were less than 6 mm and 12 g respectively so that it can be placed between the handle and the palm without any inconvenience during the measurement. Finally, using the device we estimated anti-vibration glove performances considering the frequency characteristics of generated vibration by the power tool.