• Title/Summary/Keyword: Anti-saturation

Search Result 55, Processing Time 0.025 seconds

A Study on the Fault-Tolerant and Bumpless Switching Control for Boiler Systems in the Power Plant (발전용 보일러 시스템의 이상허용 및 과도상태의 유연한 제어에 관한 연구)

  • Kwon, Oh-Kyu;Lee, Young-Sam
    • Proceedings of the KIEE Conference
    • /
    • 1998.11b
    • /
    • pp.689-692
    • /
    • 1998
  • In this research a fault-tolerant and bumpless switching control is proposed for boiler systems used in the power plants. Firstly, three operating points are selected to control the nonlinear boiler through the full operational range, and the $H_{\infty}$ loop shaping controller and the model-based predictive controller(MBPC) are designed. To prevent the windup and bump problems which are caused by the actuator saturation and the controller switching, an anti-windup and bump less transfer technique is adopted to the $H_{\infty}$ loop shaping controller. Also the constrained gain-scheduling technique is applied to MBPC to achieve the same objective. Secondly, the fault-tolerant control technique is proposed to continue the control action without stopping the boiler operation even in case of some faults. Through various simulation studies, the performances of the proposed control techniques are demonstrated.

  • PDF

A Study en the Fault-Tolerant and Bumpless Switching Control for Boiler Systems in the Power Plant (발전용 보일러 시스템의 이상허용 및 과도상태의 유연한 제어에 관한 연구)

  • Kwon, Oh-Kyu;Lee, Young-Sam
    • Proceedings of the KIEE Conference
    • /
    • 1998.11a
    • /
    • pp.369-372
    • /
    • 1998
  • In this research a fault-tolerant and bumpless switching control is proposed for boiler systems used in the power plants. Firstly, three operating points are selected to control the nonlinear boiler through the full operational range, and the $H_{\infty}$ loop shaping controller and the model-based predictive controller(MBPC) are designed. To prevent the windup and bump problems which are caused by the actuator saturation and the controller switching, an anti-windup and bumpless transfer technique is adopted to the $H_{\infty}$ loop shaping controller. Also the constrained gain-scheduling technique is applied to MBPC to achieve the same objective. Secondly, the fault-tolerant control technique is proposed to continue the control action without stopping the boiler operation even in case of some faults. Through various simulation studies, the performances of the proposed control techniques are demonstrated.

  • PDF

Accurate Evaluation and Treatment of Dyspnea in Patients with Gastrointestinal Cancer (소화기 암환자 호흡곤란의 정확한 평가와 치료)

  • Jong Yoon Lee
    • Journal of Digestive Cancer Research
    • /
    • v.11 no.2
    • /
    • pp.108-113
    • /
    • 2023
  • Dyspnea is a common symptom among patients with gastrointestinal cancer, and a comprehensive evaluation of their respiratory function is essential. Self-reporting aids in the assessment of the degree of dyspnea, while objective examination methods are performed to identify the potential underlying causes when subjective symptoms are present. Standard treatment protocols should be followed for potentially reversible and common causes of dyspnea, such as pleural effusion, pneumonia, airway obstruction, anemia, asthma, exacerbation of chronic obstructive pulmonary disease, pulmonary thromboembolism, or drug-induced interstitial lung disease. Careful and close monitoring is required due to the high frequency of pulmonary thromboembolism and the risk of cardiovascular accidents, drug-induced interstitial lung disease, or other complications from some anticancer drugs. In case of hypoxemia with an oxygen saturation of 90% or less, palliative treatment should comprise standard oxygen therapy such as nasal cannula, mask, or high-flow nasal cannula. If non-pharmacological oxygen therapy is not effective, pain control through systemic narcotic analgesics and anti-anxiety therapy with benzodiazepines may be helpful.

Bit-Rate Analysis of Various Symmetric ESQWs SEED under Optimized Input Power (최적 입사 광 전력 하에서의 대칭 ESQWs SEED의 비트 전송률 특성 분석)

  • Lim, Youn-Sup;Choi, Young-Wan
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.36D no.7
    • /
    • pp.66-79
    • /
    • 1999
  • We investigate the effects of high input power on the performance of optical bistable symmetric self-electooptic effect devices (S-SEEDs) using extremely shallow quantum wells (ESQWs). In this study, we consider the four ESQWs SEEDs; anti-reflection (AR)-coated ESQWs S-SEED, back-to-back AR coated ESQWs S-SEED, asymmetric F뮤교-Perot (AFP) ESQWs S-SEED, and back-to-back AFP-ESQWs S-SEED. As the input power increases, device performances such as on/off contrast ratio, on/off reflectivity difference are seriously degraded because of ohmic heating and exciton saturation. On the other hand, switching speed of the device increases up to certain value and then begins to decrease. With reasonable optimization of the input power for the best switching speed operation of the devices in a cascading optical interconnection system, we simulate and analyze the system bit-rate of the various ESQWs S-SEEDs, for a mesa of $5{\times}5{\mu}m^2$ size, changing the namber of quantum wells for the external bias of 0 V and -5V.

  • PDF

Study on collapse mechanism and treatment measures of portal slope of a high-speed railway tunnel

  • Guoping Hu;Yingzhi Xia;Lianggen Zhong;Xiaoxue Ruan;Hui Li
    • Geomechanics and Engineering
    • /
    • v.32 no.1
    • /
    • pp.111-123
    • /
    • 2023
  • The slope of an open cut tunnel is located above the exit of the Leijia tunnel on the Changgan high-speed railway. During the excavation of the open cut tunnel foundation pit, the slope slipped twice, a large landslide of 92500 m3 formed. The landslide body and unstable slope body not only caused the foundation pit of the open cut tunnel to be buried and the anchor piles to be damaged but also directly threatened the operational safety of the later high-speed railway. Therefore, to study the stability change in the slope of the open cut tunnel under heavy rain and excavation conditions, a 3D numerical calculation model of the slope is carried out by Midas GTS software, the deformation mechanism is analyzed, anti-sliding measures are proposed, and the effectiveness of the anti-sliding measures is analyzed according to the field monitoring results. The results show that when rainfall occurs, rainwater collects in the open cut tunnel area, resulting in a transient saturation zone on the slope on the right side of the open cut tunnel, which reduces the shear strength of the slope soil; the excavation at the slope toe reduces the anti-sliding capacity of the slope toe. Under the combined action of excavation and rainfall, when the soil above the top of the anchor pile is excavated, two potential sliding surfaces are bounded by the top of the excavation area, and the shear outlet is located at the top of the anchor pile. After the excavation of the open cut tunnel, the potential sliding surface is mainly concentrated at the lower part of the downhill area, and the shear outlet moves down to the bottom of the open cut tunnel. Based on the deformation characteristics and the failure mechanism of the landslides, comprehensive control measures, including interim emergency mitigation measures and long-term mitigation measures, are proposed. The field monitoring results further verify the accuracy of the anti-sliding mechanism analysis and the effectiveness of anti-sliding measures.

Research of Corrosion Control Technology for the Product Water of SWRO(Seawater Reverse Osmosis) by using liquid lime (액상소석회를 이용한 SWRO 생산수의 부식제어 연구)

  • Kim, Min-Chul;Hwang, Kyu-Won;Woo, Dal-Sik;Yoon, Seok-Min;Kwak, Myung-Hwa
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.1
    • /
    • pp.529-536
    • /
    • 2011
  • In this study, we confirmed that the SWRO(Sea Water Reverse Osmosis) production water has more hard corrosiveness than the tap water by fundamental experiment. According to the result, the target of this study was aimed at developing maintenance and anti-corrosion method. In the early stages of the research, batch tests using mild steel coupons and electrochemical experiments were applied to compare the corrosiveness between SWRO production water and the tap water. After then, two corrosion control methods for SWRO production water were applied. Liquid lime($Ca(OH)_2$) and Carbon Dioxide($CO_2$) were inserted and compared with the combination of liquid lime with phosphate corrosion inhibitor and carbon dioxide. The water qualities were evaluated through LSI(Langelier Saturation Index) and proper injection ratio was deduced by the result. Since then, simulated loop system test were performed to evaluate anti-corrosion effect depending on corrosion inhibitors. Subsequently, carbon steel pipes equipped at the loop system were detached for SEM, EDX and XRD analysis to acquire quantitative and qualitative data of the major corrosion products inside the pipes. In conclusion, the controled groups with anti-corrosion techniques applied were effective by appearing 97.4% and 90.9% of improvements in both case of liquid lime and the liquid lime with a phosphate corrosion Inhibitor. furthermore, major components of scale were iron oxides, on the other hand, protective effect of film formation by calcium carbonate($CaCO_3$) could be confirmed.

Measurement of OH radical spectrum in counterflow burner using degenerate four wave mixing (DFWM(degenerate four wave mixing)을 이용한 대향류버너 화염내의 OH 라디칼 스펙트럼 측정)

  • 이은성;한재원
    • Korean Journal of Optics and Photonics
    • /
    • v.7 no.2
    • /
    • pp.142-149
    • /
    • 1996
  • In non-saturation region, we measured the degenerate four wave mixing spectra of $X^2\;{\Pi}(v=0){\to}A^2{\Sigma}^+(v'=0)$ transition for OH in counterflow burner, which exists transiently in combustion reaction. We used forward box type geometry for phase matching. Calculating the population of each rotational level from the line intensities of R$_1$band and comparing it with Boltzmann distributions, we could obtain the temperatures of the flame at several points. Corrected for the absorption of incident laser fields, the final temperatures coincided with those measured by coherent anti-Stokes Raman Scattering within error $\pm$60 K near 2000 K. We also measured the concentration distribution of OH radical and it was compared to that measured by laser induced fluorescence.

  • PDF

Intranasal administration of dexmedetomidine (DEX) as a premedication for pediatric patients undergoing general anesthesia for dental treatment

  • Lee, Yookyung;Kim, Jongsoo;Kim, Seungoh;Kim, Jongbin
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.16 no.1
    • /
    • pp.25-29
    • /
    • 2016
  • Background: The most important reason for pre-operative administration of medication is to reduce anxiety. Alleviation of fear and anxiety about surgery enables patients to remain comfortable during treatment. Dexmedetomidine (DEX) is a fast-acting drug that is used as a premedication in different circumstances because it has sedative and anti-anxiolytic effects, and stable hemodynamics. It also has the advantage of intranasal administration. The aim of this study was to investigate the effects and hemodynamic stability of DEX by retrospectively analyzing cases in which DEX was administered nasally as a premedication. Methods: Ten patients treated at Dankook University Dental Hospital, recruited between February and April 2015, received intranasal delivery of $2{\mu}g/kg$ DEX, 30 minutes prior to general anesthesia. Anesthesia records of anxiety, blood pressure, respiration, pulse, estimated arterial oxygen saturation ($SpO_2$), and partial pressure, or maximum concentration, of carbon dioxide ($ETCO_2$) were analyzed. Results: Administration of DEX prior to a general anesthetic effectively relieved anxiety. Respiratory depression, the most severe adverse effect of other sedatives, was not observed. Hemodynamic stability under general anesthesia was maintained during treatment and a reduction in emergence delirium was observed upon completion of treatment. Conclusions: Premedication administration of DEX is safe for pediatric patients undergoing dental treatment under general anesthesia.

Pharmacological Activities of Flavonoids (I) -Relationships of Chemical Structure of Flavonoids and their Inhibitory Activity of Hypersensitivities- (Flavonoids의 약리작용(I) -Flavonoids 구조와 과민반응 억제작용과의 상관성-)

  • Kim, Chang-Johng;Chung, Jin-Mo
    • YAKHAK HOEJI
    • /
    • v.34 no.5
    • /
    • pp.348-364
    • /
    • 1990
  • The activities of twenty-one flavonoids and their related compounds on the hypersensitivity reaction against various antigens were studied in vitro and in vivo. 1. Generally flavonoids inhibited significantly the homologous passive cutaneous anaphylaxis (PCA) induced by reaginic antibody as compared as anaphylaxis by compound 48/80-induced mast cell degranulation, and so more strongly active in the IgE-mediated anaphylaxis than non-IgE-mediated anaphylaxis. 2. Flavonids inhibited remarkably Arths reaction, hemolysin titer, delayed hypersensitivity, haemagglutinin titer, rosette forming cells and plague forming cells against sheep red blood cells, and so it exhibited that flavonoids inhibited type 2, 3 and 4 hypersensitivity. 3. Quercetin, kaempferol, hesperetin, disodium cromoglycate, malvin and baicalein were active dose-dependently in the all types of hypersensitivity. Fisetin, daidzein, morin, narigin, flavone, catechin, rutin, hesperidin, neophsperidin, apigenin and chrysin were significantly active in the various types of hypersensitivity, but apigenin, rutin and catechin were less active in the delayed hypersensitivity. Taxifolin was significantly active in PCA and histamine-induced anaphylaxis except other types of hypersensitivity. Rotenone and cyanin also inhibited all types of hypersensitivity, but they are toxic. 4. Based on these results from hypersensitivity, the following flavonoid structure-activity relationships became apparent. 1) Flavonoids with $C_{2-3}$ double bond in C-ring were more active than that of $C_{2-3}$ saturation. 2) Flavonoids with $C_4$ ketone group in C-ring were more active than abscence of them except catechin and malvin. 3) Flavonoids with benzene ring at positions 2 or 3 in C-ring exhibited same activities. 4) Flavonoids with opening of the C-ring does not abolish their activities. 5) The glycosylated flavonoids in position 3 or 7 was less active than their aglycone. 6) Flavonoids with the more hydroxy group in A and B-ring were more active. 7) Flavonoids with or without $C_3-OH$ did not change their activities.

  • PDF

Importance of Green Density of Nanoparticle Precursor Film in Microstructural Development and Photovoltaic Properties of CuInSe2 Thin Films

  • Hwang, Yoonjung;Lim, Ye Seul;Lee, Byung-Seok;Park, Young-Il;Lee, Doh-Kwon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.471.2-471.2
    • /
    • 2014
  • We demonstrate here that an improvement in precursor film density (green density) leads to a great enhancement in the photovoltaic performance of CuInSe2 (CISe) thin film solar cells fabricated with Cu-In nanoparticle precursor films via chemical solution deposition. A cold-isostatic pressing (CIP) technique was applied to uniformly compress the precursor film over the entire surface (measuring 3~4 cm2) and was found to increase its relative density (particle packing density) by ca. 20%, which resulted in an appreciable improvement in the microstructural features of the sintered CISe film in terms of lower porosity, reduced grain boundaries, and a more uniform surface morphology. The low-bandgap (Eg=1.0 eV) CISe PV devices with the CIP-treated film exhibited greatly enhanced open-circuit voltage (VOC, from 0.265 V to 0.413 V) and fill factor (FF, from 0.34 to 0.55), as compared to the control devices. As a consequence, an almost 3-fold increase in the average power conversion efficiency, 3.0 to 8.2% (with the highest value of 9.02%), was realized without an anti-reflection coating. A diode analysis revealed that the enhanced VOC and FF were essentially attributed to the reduced reverse saturation current density (j0) and diode ideality factor (n). This is associated with the suppressed recombination, likely due to the reduction in recombination sites such as grain/air surfaces (pores), inter-granular interfaces, and defective CISe/CdS junctions in the CIP-treated device. From the temperature dependences of VOC, it was confirmed that the CIP-treated devices suffer less from interface recombination.

  • PDF