• 제목/요약/키워드: Anti-freezing

검색결과 118건 처리시간 0.025초

내부식성 콘크리트 개발을 위한 기초연구로서 개질유황 혼합 콘크리트의 물성 평가 (Evaluation on the Properties of Modified-sulfur Concrete as a Basic Study for Development of Anti-corrosive Concrete)

  • 박상순;나옥정
    • Corrosion Science and Technology
    • /
    • 제15권1호
    • /
    • pp.28-37
    • /
    • 2016
  • Due to the increased construction of offshore concrete structures and the use of de-icing salts for the purpose of snow removal, the needs for the development of anti-corrosive concrete are increasing. To solve these problems, an evaluation of the mechanical and durability properties for concrete were conducted by mixing modified-sulfur as 0 %, 5 %, 10 %, 15 % cement weight ratio. Both strengths and the properties affecting durability such as water absorption coefficient, chloride ion permeability, accelerated carbonation resistance, rapid freezing and thawing, and chemical resistance were evaluated. All evaluations performed were according to the test specifications associated KS. The results indicate that mixing of modified-sulfur lowed chloride ion permeability and improved chemical resistance.

탄소섬유 쉬트를 활용한 도로 결빙방지 시스템 개발을 위한 기초연구 (Fundamental Study for Development of an Anti-Icing Pavement System Using Carbon-Fiber Sheet)

  • 임치수;박광필;이재준;이병석
    • 한국도로학회논문집
    • /
    • 제18권3호
    • /
    • pp.59-65
    • /
    • 2016
  • PURPOSES : This paper aims to develop a road pavement de-icing system using carbon sheet to replace the older snow de-icing method. Carbon sheet is a light and high-strength metal. Hence, various bodies of research for its applications in many industries have progressed. METHODS : The experiment was conducted in a laboratory. The carbon sheet supplied voltage through a power supply system, and produced heat transfers to the concrete surface. Various factors, such as pavement material, carbon sheet width, penetration depth, and freezing-thawing resistance, were considered in the conducted experiments to confirm the heating transfer efficiency of the carbon sheet. RESULTS : The carbon sheet used was a conductor. Therefore, it produced heat if voltage was supplied. The exposed carbon sheet on the atmosphere did not affect the carbon sheet width when it provided constant voltage. However, the sheet showed different heating behaviors by width change when the carbon sheet penetrated into the concrete. Moreover, the freezing-thawing resistance was decreased by the carbon sheet with increasing width. CONCLUSIONS : The experiments confirmed the possibility of developing a road snow melting system using a carbon sheet. The antiicing system using the carbon sheet to replace the traditional anti-icing system has disadvantages of environmental pollution risk and electric leakage. The pavement also improved its toughness resistance. The utilization value will be very high in the future if carbon sheet heat loss can be minimized and durability is improved.

부동액 함유량과 냉각수 종류에 따른 자동차 엔진 성능분석 (Automotive Engine Performance Analysis of antifreeze content and water type)

  • 홍성인
    • 한국산학기술학회논문지
    • /
    • 제16권3호
    • /
    • pp.1594-1599
    • /
    • 2015
  • 세계 자동차 산업은 지난 100여년간의 내연기관의 시대에서 환경, 에너지 그리고 IT기술들이 접목된 친환경, 첨단자동차의 시대로 변모해가고 있다. 지금까지 자동차의 연구는 새로운 기술에 대한 연구 및 개발에 주력해 왔다. 자동차의 새로운 기술개발도 중요한 사항이지만, 최첨단 기술이 적용된 자동차 이전에 이미 사용되어지고 있는 자동차의 성능 및 환경개선 문제도 중요한 시점이 되었다. 새로운 기술개발 뿐 만아니라 기존의 기술에 대한 효과적인 적용 또한 중요한 사항이다. 부동액 기술 또한 자동차 기술의 중요한 부분이다. 본 연구는 부동액의 효과적인 적용을 위하여 자동차 엔진 냉각수에 함유된 부동액의 함유량과 냉각수의 종류(수돗물, 증류수, 지하수)에 따라 자동차 엔진 온도와 성능에 미치는 영향을 파악하고 원인을 규명하는 실험적 연구이다. 냉각수의 어는점 -10, -20, -30, -40, $-50^{\circ}C$에서 다이나모 성능시험과 수치해석을 실시하였다. 냉각수(증류수) 어는점 $-10^{\circ}C$에서 측정 기준점에서 최고 성능 71.112, 99.622hp를 나타냈다.

Heat transfer performance of a helical heat exchanger depending on coil distance and flow guide for supercritical cryo-compressed hydrogen

  • Cha, Hojun;Choi, Youngjun;Kim, Seokho
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제24권3호
    • /
    • pp.62-67
    • /
    • 2022
  • Liquid hydrogen (LH2) has a higher density than gaseous hydrogen, so it has high transport efficiency and can be stored at relatively low pressure. In order to use efficient bulk hydrogen in the industry, research for the LH2 supply system is needed. In the high-pressure hydrogen station based on LH2 currently being developed in Korea, a heat exchanger is used to heat up supercritical hydrogen at 700 bar and 60 K, which is pressurized by a cryogenic high-pressure pump, to gas hydrogen at 700 bar and 300 K. Accordingly, the heat exchanger used in the hydrogen station should consider the design of high-pressure tubes, miniaturization, and freezing prevention. A helical heat exchanger generates secondary flow due to the curvature characteristics of a curved tube and can be miniaturized compared to a straight one on the same heat transfer length. This paper evaluates the heat transfer performance through parametric study on the distance between coils, guide effect, and anti-icing design of helical heat exchanger. The helical heat exchanger has better heat transfer performance than the straight tube exchanger due to the influence of the secondary flow. When the distance between the coils is uniform, the heat transfer is enhanced. The guide between coils increases the heat transfer performance by increasing the heat transfer length of the shell side fluid. The freezing is observed around the inlet of distribution tube wall, and to solve this problem, an anti-icing structure and a modified operating condition are suggested.

콘크리트제품의 동결저항성에 관한 실험적 연구 (Experimental Study on the Frost Resistance of Concete Product)

  • ;;이상훈
    • 한국방재학회:학술대회논문집
    • /
    • 한국방재학회 2011년도 정기 학술발표대회
    • /
    • pp.91-91
    • /
    • 2011
  • The quality of the surface layer in concrete structures plays an important role in the durability of the concrete. The concrete factory products are made as they improve the appearance of the surface and compressive strength in need. A common criterion to judge the quality of concrete products frequently seen in our daily life appears to be "beauty" in terms of consistent shaping. However, as for most concrete curb in such areas where a large amount of anti-freezing agents(NaCl) and ice and snow melting agents(CaCl2) are spread over roads to ensure road safety during the winter season, since deterioration advances from the surface, scaling is seen on the surface concrete due to deterioration which combined freezing damage and salt damage. Especially, In cold northern districts, the spreading amount of deicing salts increases by regulation of studded tire use, and the scaling of the concrete products, the various parts of concrete structures for roads is increasing in recent years. In this study, L-shape concrete curb were targeted, the permeable form method with the commercial permeable sheet was applied to it and the improvements of the quality were examined. By the permeable form method, surface layers got strengthened, which prevented permeation of the deterioration factor from the outside, and the scaling resistance of the upper surface where the permeable sheet was applied improved exceedingly. It will be expected by applying the permeable form method to various concrete products that frost resistance improves and scaling damage decreases.

  • PDF

Numerical Investigation on Freezing in Ballast Tank of Ship Navigating in Ice-bound Sea

  • Kang, Ho-Keun;Kim, Ki-Pyoung;Ahn, Soo-Whan
    • 동력기계공학회지
    • /
    • 제17권2호
    • /
    • pp.95-102
    • /
    • 2013
  • For vessels operating in the cold climate regions, the ballast water inside or hopper tanks above the waterline may be frozen, starting at the top of the tank and at the side walls. Therefore, countermeasures against freeze-up of the ballast tank such as air-bubbling system, hot steam injecting system, heating coil system and water circulating system are taken to prevent freeze-up phenomenon; however, there are no rigorous investigations of anti-freezing to examine the effectiveness and validity of systems against freeze-up of the ballast tank, in which the temperatures are about $-25^{\circ}C$ (ambient air temperature) and $0^{\circ}C$ (sea water), respectively. In this paper, to ensure reasonable specifications for cold regions if the measures from the above-mentioned systems against freeze-up are effective, the phenomenon of ballast tank freeze-up is simulated and discussed in low temperature conditions. With the results using the commercial CFD code, CFX 14, the most cost-effective solution is conducted to prevent being frozen along the outer surface.

Numerical Analysis on Freezing in the Ship Voyaging in Polar Regions

  • Kang, Ho-Keun;Kim, Ki-Pyoung;Ahn, Soo-Whan
    • 동력기계공학회지
    • /
    • 제17권5호
    • /
    • pp.30-37
    • /
    • 2013
  • For vessels operating in the cold climate regions, the ballast water inside or hopper tanks above the waterline may be frozen, starting at the top of the tank and at the side walls. Therefore, countermeasures against freeze-up of the ballast tank such as air-bubbling system, hot steam injecting system, heating coil system and water circulating system are taken to prevent freeze-up phenomenon; however, there are no rigorous investigations of anti-freezing to examine the effectiveness and validity of systems against freeze-up of the ballast tank, in which the temperatures are about -$25^{\circ}C$ (ambient air temperature) and $0^{\circ}C$ (sea water), respectively. In this paper, to ensure reasonable specifications for cold regions if the measures from the above-mentioned systems against freeze-up are effective, the phenomenon of ballast tank freeze-up is simulated and discussed in low temperature conditions. With the results using the commercial CFD code, CFX 14, the most cost-effective solution is conducted to prevent being frozen along the outer surface.

동파방지열선 화재 흔적분석과 발화원인 연구 (A Study for the Fire Analysis and Igniting Cause of Freezing Protection Heating Cables)

  • 이정일;하각천
    • 한국안전학회지
    • /
    • 제33권3호
    • /
    • pp.15-20
    • /
    • 2018
  • There have been a number of major fatal fire accidents in Korea recently. The number of fires in 2017 were 44,178, which is not only increasing number of fires but also increasing in casualties. Particularly, the fire at Jecheon Sports Center, which suffered many casualties, is expected to have a huge impact. The cause of the fire has not been determined yet, but heat waves on the ceiling have also been pointed out. As such, the copper heating waves, which are used as a preventive measure against damage of pipes due to freezing of pipes, etc., always have a fire hazard. To determine the possibility of a flame-resistant heated fire, a positive electric cable product was used to artificially ignite and analyze the results. In case of a short circuit, the external covering of the positive electric cable is damaged, but not short circuit unless the heating material surrounding the wire is damaged. Due to the characteristics of heating cable for preventing copper waves, the chances of insulation becoming more severe due to moisture and temperature changes are higher than normal wires. If the internal heating system is carbonized by insulating deterioration without damage to the outer coating, it is likely to cause trekking, to form a winding loop in the heating materials, and to cause short circuit in the heated materials. For the positive temperature line, if the middle is shorted, the current continues to flow to the short circuit unless the breaker disconnects. Consequently, a heated fire that does not cut off the power immediately may leave multiple marks or cuts.

실내동결시험을 통한 열류량 분석에 따른 동결-융해 조건 분석 및 한랭지역의 분류 (Classification of cold regions and analysis of the freeze-thaw repetition cycle based on heat transfer quantity by freezing test)

  • 안재욱;서정은;정민형;성주현
    • 한국터널지하공간학회 논문집
    • /
    • 제20권6호
    • /
    • pp.957-972
    • /
    • 2018
  • 한랭지역에 건설된 터널은 내 외부의 온도변화에 의해 갱구부 또는 환기구와 같이 특정한 구간에서 외부 온도변화의 영향으로 균열, 누수 등을 비롯한 심각한 결함이 발생할 수 있다. 이러한 동결-융해로 인한 터널의 결함을 방지하기 위해서는 동결 피해가 우려되는 구간에 대해서 적절한 동결 피해 방지 대책을 적용하여야 하지만 동결-융해 조건을 판단하는 구체적인 기준은 제시되어 있지 않다. 본 연구에서는 국내 터널의 정밀안전진단 결과를 통해 강원지역의 동결피해 현황을 분석하였으며 향후 한랭지역 터널의 동결피해 저감을 위한 설계 및 유지관리에 활용할 수 있도록 동결-융해 반복일수(F) 조건에 따른 국내 동결피해 가능지역을 분류하고자 한다. 따라서 한랭지역 터널의 동결피해 사례분석과 국내 외 동해환경 평가기준을 바탕으로 콘크리트 시험체의 온도변화에 대한 실내실험을 실시하였으며 실험적 검토결과를 기반으로 시간 및 온도변화에 따른 열류량(W) 분석을 실시하였다. 최종적으로 열류량(W) 분석결과와 국내의 기후특성을 고려하여 동결-융해 반복일(F)에 대한 조건을 제안하였으며, 동절기 동결피해에 대비하여 효율적인 설계 및 유지관리에 활용할 수 있도록 국내 한랭지역을 분류하였다.

Competitive Indirect ELISA를 이용한 Bovine Myosin의 동결 변성도 측정 (Monitoring the Rate of Frozen Denaturation of Bovine Myosin by Competitive Indirect ELISA Method)

  • 김성배;이주운;박종흠;도형기;현창기;신현길
    • 한국식품과학회지
    • /
    • 제30권4호
    • /
    • pp.862-870
    • /
    • 1998
  • Myosin과 그 subfragment인 S-1과 LMM를 항원으로 하는 간접경합 효소면역분석법(Ci-ELISA)을 이용하여 동결육의 변화를 연구함으로써 수입 냉동육과 국내산 냉장 한우육과의 차별화를 위한 기초 자료를 마련하기 위하여 본 연구를 실시하였다. 각 항체의 표준곡선을 작성하였으며 최적반응범위는 $4{\sim}125{\;}{\mu}g/mL$이었고, 검출한계는 $0.1{\;}{\mu}g/mL$이었다. 확립된 Ci-ELISA를 이용하여 각각 $-10^{\circ}C,{\;}-20^{\circ}C,{\;}-50^{\circ}C$, 그리고 $-80^{\circ}C$에서 동결 기간 동안의 변화와 해동과 재동결에 따른 변화를 측정하였을 때 동결 기간 중 anti-MWM IgG와 반응한 myosin은 비교구와 비교하였을 때 $-20^{\circ}C$에서 변성도가 가장 컸으며 $-50^{\circ}C$에서 가장 적게 변성되었다. 단백질 용해성의 변화와 myosin과 항체와의 면역 친화성을 비교하였을 때 용해성이 감소하는 속도보다 더 빠르게 myosin이 변성되는 것으로 판단되었다. Anti S-1 IgG의 면역 친화성의 변화는 anti-MWM IgG에서 얻은 결과와 비교하였을 때 전혀 다른 경향을 보였다. anti-MWM IgG는 면역 친화성이 1개월 이후 급격히 감소된 데 비하여 anti S-1 IgG는 그와 같은 큰 변화를 나타내지 않았다. 반복되는 해동과 재동결 처리에서 anti-MWM IgG는 myosin과의 반응에서 2회 해동시부터 공격한 반응성의 감소를 보였으며 6회 해동시에는 85%까지 반응력을 상실했다(P<0.05). 두 실험 조건에서 $-20^{\circ}C$의 처리구의 myosin이 가장 심한 영향을 받은 것으로 나타났다. Anti-LMM IgG는 anti-MWM IgG에서 얻은 결과와 매우 유사한 경향을 보였다. $-10^{\circ}C$$-20^{\circ}C$에서 처리된 우육의 myosin은 저온에서 처리된 시료의 그것보다 보다 약 $10{\sim}15%$ 정도 더 많은 변성을 보인 것으로 사료된다.

  • PDF