• Title/Summary/Keyword: Anti-Windup Scheme

Search Result 26, Processing Time 0.024 seconds

A Comparative Study on Anti-windup Schemes for PID Control Systems (PID제어계를 위한 누적방지기법의 비교)

  • 류지수;허학범;박태건;이기상
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.127-127
    • /
    • 2000
  • The anti-windup schemes developed so far are summarized and the similarities/differences schemes are discussed. The anti-windup schemes are applied to a DC servomotor control system with PID controller to perform comparative study and sensitivity analysis. Based on those results, some criteria for choosing anti-windup scheme are suggested. The results of this study provide a very useful guideline for selecting and designing the anti-windup scheme for various types of PID control systems.

  • PDF

EA-based Tuning of a PID Controller with an Anti-windup Scheme (안티와인드업 기법을 가지는 PID 제어기의 EA 기반 동조)

  • Jin, Gang-Gyoo;Park, Dong-Jin
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.19 no.10
    • /
    • pp.867-872
    • /
    • 2013
  • Many practical processes in industry have nonlinearities of some forms. One commonly encountered form is actuator saturation which can cause a detrimental effect known as integrator windup. Therefore, a strategy of attenuating the effects of integrator windup is required to guarantee the stability and performance of the overall control system. In this paper, optimal tuning of a PID (Proportional-Integral-Derivative) controller with an anti-windup scheme is presented to enhance the tracking performance of the PID control system in the presence of the actuator saturation. First, we investigate effective anti-windup schemes. Then, the parameters of both the PID controller and the anti-windup scheme are optimally tuned by an EA (Evolutionary Algorithm) such as the IAE (Integral of Absolute Error) is minimized. A set of simulation works on two high-order processes demonstrates the benefit of the proposed method.

Tuning-free Anti-windup Strategy for High Performance Induction Machine Drives (고성능 유도전동기 구동을 위한 자동 튜닝 Anti-windup 기법)

  • Seok Jul-Ki;Lee Dong-Choon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.1
    • /
    • pp.29-37
    • /
    • 2005
  • This paper presents a tuning-free conditional integration anti-windup strategy for induction machine with Proportional-Integral(PI) type speed controller. The on/off condition of integral action is determined by the frequency domain analysis of machine torque command without a prior knowledge of set-point changes. There are no tuning parameters to be selected by users for anti-windup scheme. In addition, the dynamic performance of the proposed scheme assures a desired tracking response curve with minimal oscillation and settling time even in the change of operating conditions. This algorithm is useful in many high performance induction machine applications not to allow the oscillation and overshoot of speed/torque responses. The main idea can be extended to general applications such as chemical processes and industrial robots.

A New Anti-windup Method Using the Linear Quadratic Observer (LQ관측기를 사용한 새로운 누적방지 기법)

  • Kim, Tae-Shin;Yang, Ji-Hyuk;Kwon, Oh-Kyu
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.16 no.2
    • /
    • pp.134-139
    • /
    • 2010
  • In order to overcome some problems of existing anti-windup methods, this paper defines LQ (Linear Quadratic) observer and proposes a new anti-windup method using the LQ observer. LQ observer is derived by linear quadratic optimization in order to calculate controller states, which make the controller outputs equal to the plant inputs. And we propose an algorithm so that it can be implemented by a digital controller easily. The relationship between the design parameters and the anti-windup performance is shown via some numerical examples, which cover the cases with the anti-windup method using LQ observer designed and the case without it. Finally, the anti-windup performance of the proposed method is exemplified via comparison with the existing model-based conditioning scheme method[4].

A Study on Anti-Windup Schemes for PID Control Systems (PID제어계를 위한 누적방지기법에 관한 연구)

  • Ryu, Ji-Su;Kim, Young-Gon;Park, Tae-Geon;Lee, Kee-Sang
    • Proceedings of the KIEE Conference
    • /
    • 2000.07d
    • /
    • pp.2323-2326
    • /
    • 2000
  • In this paper, the anti-windup schemes developed so far are summarized and the similarities/differences of those schemes are discussed. The anti-windup schemes are applied to a DC servomotor system with PID controller to perform comparative study and sensitivity analysis. Based on those results, some criteria for choosing anti-windup scheme are suggested. The results of this study provide a very useful guideline for selecting and designing the anti-windup scheme for various types of PID control systems.

  • PDF

Comparison and Evaluation of Anti-Windup PI Controllers

  • Li, Xin-Lan;Park, Jong-Gyu;Shin, Hwi-Beom
    • Journal of Power Electronics
    • /
    • v.11 no.1
    • /
    • pp.45-50
    • /
    • 2011
  • This paper proposes a method for comparing and evaluating anti-windup proportional-integral (PI) control strategies. The so-called PI plane is used and its coordinate is composed of the error and the integral state. In addition, an anti-windup PI controller with integral state prediction is proposed. The anti-windup scheme can be easily analyzed and evaluated on the PI plane in detail. Representative anti-windup methods are experimentally applied to the speed control of a vector-controlled induction motor driven by a pulse width modulated (PWM) voltage-source inverter (VSI). The experimental results compare the anti-windup PI controllers. It is empathized that the initial value of the integral state at the beginning of the linear range dominates the control performance in terms of overshoot and settling time.

A Dynamic Anti-windup Scheme for Input-constrained Feedback Linearizable Nonlinear Systems (궤환선형화 가능한 비선형 시스템의 입력제한을 고려한 동적 와인드엎 방지)

  • 윤성식;박종구;윤태웅
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.534-534
    • /
    • 2000
  • This paper proposes a dynamic compensation scheme for input-constrained feedback linearizable nonlinear systems to cope with the windup phenomenon. Given a feedback linearizing controller for such a nonlinear system designed without considering its input constraint, an additional dynamic compensator is proposed to account for the constraint. This dynamic anti-windup is based on the minimization of a reasonable performance index, and some stability properties of the resulting closed-loop are presented.

  • PDF

Tuning-free Anti-windup Strategy for High Performance Induction Machine Drives (고성능 유도전동기 구동을 위한 자동 튜닝 Anti-windup 기법)

  • Seok Jul-Ki;Bae Sang-Gyu;Lee Dong-Choon
    • Proceedings of the KIPE Conference
    • /
    • 2004.07a
    • /
    • pp.312-315
    • /
    • 2004
  • This paper presents a tuning-free conditional integration anti-windup strategy for induction machine with Proportional-Integral (PI) type speed controller. The on/off condition of integral action is determined by the frequency domain analysis of machine torque command without a prior knowledge of set-point changes. There are no tuning parameters to be selected by users for anti-windup scheme. In addition, the dynamic performance of the proposed scheme assures a desired tracking response curve with minimal oscillation and settling time even in the change of operating conditions. This algorithm is useful in many high performance induction machine applications not to allow the oscillation and overshoot of speed/torque responses. The main idea can be extended to general applications such as chemical processes and industrial robots.

  • PDF

Anti-Windup Scheme to Control DC Voltage of Three-Phase Four-Wire Active Power Filter (누적방지 기법을 적용한 3상 4선식 능동전력필터 시스템의 직류전압 제어)

  • 정교범
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.2
    • /
    • pp.128-136
    • /
    • 2003
  • This paper investigates the application of the anti-windup scheme to control U voltage of the three-phase four-wire active power filter, installed in a three-phase four-wire power system. In order to reduce efficiently the harmonic currents caused by the switching loads and to improve the whole performance of the flower system, the DC voltage of the three-phase four-wire active power filter should be properly controlled. PI controller can be applied to the U voltage controller of the three-phase four-wire active power filter. However, a large error input to PI controller leads to a windup phenomenon which deteriorate the dynamic characteristics of the U voltage controller Therefore, the application of the anti-windup scheme for the DC voltage controller is proposed and the improved performances of the anti-windup U voltage controller are proved through the computer simulation study.

Dynamic Anti-Windup for Robot Systems with Friction

  • Yoon, S.S.;Yamada, Y.;Park, J.K.;Yoon, T.W.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1966-1971
    • /
    • 2005
  • Though several previous anti-windup techniques have been proposed, they are limited to linear systems or friction is not considered. Thus this paper proposes a compensation scheme for input-constrained robot systems with friction to cope with the windup phenomenon and shows its effectiveness by simulations. Given a feedback linearizing controller for a robot system designed without considering its input constraint, an additional dynamic compensator is proposed to account for the constraint. The dynamic anti-windup is based on the minimization of a reasonable performance index, and properties of the resulting closed-loop are presented.

  • PDF