• Title/Summary/Keyword: Anti sounds

Search Result 13, Processing Time 0.021 seconds

A study on the Frequency Analysis Function of the Auricle Using A Notch Filter

  • Park, Dong-Cheol
    • International journal of advanced smart convergence
    • /
    • v.10 no.4
    • /
    • pp.241-255
    • /
    • 2021
  • The human auricle is the first part to receive sound from the outside. In this part, the frequency range of human recognizable form is divided and organized. In this study, we propose modeling by applying a single sound source to the surface of the human auricle. This means that when the sound pressure of a low frequency (low frequency) sound enters the pinna, the impedance felt at the tip of a part of the non-linear surface of the pinna is mainly due to the tensile force at the end of the part of the non-linear surface of the pinna. By expressing the situation of moving at a very small speed, the characteristic impedance of the pinna was confirmed to be negative infinity, and it was also confirmed that the speed at the tip of a part of the non-linear surface of the pinna was 0 in the anti-resonance state. It was found that the wave propagation phenomenon that determines the characteristics of the filter is determined by how large the wavelength, kL, is compared to the length of the tip of a part of the non-straight surface of the pinna. Humans first receive sounds from outside through their ears. The auricle is non-linear and has a curved shape, and it is known that it analyzes frequencies while receiving external sounds. The human ear has an audible frequency range of 20Hz - 20,000Hz. Through the study, we applied the characteristics of the notch filter to hypothesize that the human audible frequency range is separated from the auricle, and applied filter theory to analyze it, and as a result, meaningful results were obtained. The curved part and the inner part of the auricle function as a trumpet, collecting sounds, and at the same time amplifying the weak sound of a specific band. The point was found and the shape of the envelope detected in the auricle was found. Selectivity for selecting sounds coming from the outside is the formula of the pinna that implements the function of Q. The function of distinguishing human-recognizable sound from the pinna from low to high through frequency analysis is performed in the pinna, and the 2-3kHz area, where human hearing threshold is the most sensitive, is also the acoustic impedance of the most recessed area of the pinna. It can be seen that starting from.

A Study on Vowel Formant Variation by Vocal Tract Modification (성도 변형에 따른 모음 포먼트의 변화 고찰)

  • Yang, Byung-Gon
    • Speech Sciences
    • /
    • v.3
    • /
    • pp.83-92
    • /
    • 1998
  • Vowels are classified by vocal tract shapes. These shapes form constriction points along the tract, which have an influence on such vocal tract resonance as $F_l,\;F_2,\;F_3$, and so on. This study reviews the perturbation theory of the tract and determines the corresponding formant frequencies from modified vocal tracts using vocal tract area function. Then, formant variation is observed from the theory. Finally, each set of $F_l,\;F_2,\;and\;F_3$ frequency is input to a speech synthesis software to make a vowel sound. Auditory impression of each sound without any modification of its vocal tract shape is almost the same as the corresponding phonetic symbol. Formant frequencies of $F_l,\;F_2,\;F_3$ vary according to the perturbation theory. Generally, constriction along the node causes formant values to decrease while constriction along the anti-node cause it to increase. Vocal tracts modified by more than $3\;cm^2$ change vowel qualities of /a/ and /i/ into those of f /v/ and /$\varepsilon$/, respectively. This study will be helpful in simulating sounds from modified vocal tracts before any operation. Further studies are desirable to compare vocal tract shapes of various languages and their sounds together.

  • PDF

소음의 크기와 면역음 제공이 산란계의 생산성에 미치는 영향

  • 이덕수;강희설;최희철;권두중;유용희;송준익;김형호
    • Proceedings of the Korea Society of Poultry Science Conference
    • /
    • 2002.11a
    • /
    • pp.106-107
    • /
    • 2002
  • The study carried out to investigate the effect of noise levels on the production of layers indicated that the 83.67% and 79.17% egg production of layers affected with the 75 db and 100 db noise levels, respectively, were reduced upto 1.6 and 6.4 respectively, compared with the 84.56% egg production of layser treated with no noise. Egg weight was lowest in layers treated with 100 db noise levels. egg production (80.30%) and egg wight (60.87g) of layer group treated with Anti sound were higher than egg production (79.40%) and egg weight (59.95g) of layer group treated with general noise.

  • PDF

Implementation of a Single-chip Speech Recognizer Using the TMS320C2000 DSPs (TMS320C2000계열 DSP를 이용한 단일칩 음성인식기 구현)

  • Chung, Ik-Joo
    • Speech Sciences
    • /
    • v.14 no.4
    • /
    • pp.157-167
    • /
    • 2007
  • In this paper, we implemented a single-chip speech recognizer using the TMS320C2000 DSPs. For this implementation, we had developed very small-sized speaker-dependent recognition engine based on dynamic time warping, which is especially suited for embedded systems where the system resources are severely limited. We carried out some optimizations including speed optimization by programming time-critical functions in assembly language, and code size optimization and effective memory allocation. For the TMS320F2801 DSP which has 12Kbyte SRAM and 32Kbyte flash ROM, the recognizer developed can recognize 10 commands. For the TMS320F2808 DSP which has 36Kbyte SRAM and 128Kbyte flash ROM, it has additional capability of outputting the speech sound corresponding to the recognition result. The speech sounds for response, which are captured when the user trains commands, are encoded using ADPCM and saved on flash ROM. The single-chip recognizer needs few parts except for a DSP itself and an OP amp for amplifying microphone output and anti-aliasing. Therefore, this recognizer may play a similar role to dedicated speech recognition chips.

  • PDF

Snoring Detection using Polyvinylidene Fluoride Vibration Sensors (Polyvinylidene Fluoride 진동센서를 이용한 코골이 검출)

  • Jee, Duk-Keun;Wei, Ran;Kim, Hee-Sun;Im, Jae-Joong
    • Science of Emotion and Sensibility
    • /
    • v.14 no.3
    • /
    • pp.459-466
    • /
    • 2011
  • Sleep diseases such as snoring and sleep apnea are physically, mentally harmful and results serious health problems. Snoring, known as breathing noise, is caused by coupled oscillation of the airway when the air passes through the trachea, and sleep apnea is caused by upper airway blockage. In order to solve these problems, many attempts have been made to detect the snoring during sleep and alleviate it. In this study, a new sensing system and analysis algorithm were developed in order to detect snoring sounds correctly under various sleep environments. Two polyvinylidene fluoride (PVDF) vibration sensors were used inside the pillow. The first PVDF sensor detects vibration transmitted through skull caused by snoring. And the second PVDF sensor detects both snoring sounds and ambient noises. The signals of two sensors were acquired through the designed analog circuits, and analyzed for snoring detection. Ten volunteers were participated for the experiment under five different conditions. Data from two PVDF sensors were processed by the established analysis algorithm, and snoring sounds were compared to noises. The results indicated that the energy of snoring is 70% bigger than that of ambient noise, which proves effectiveness of sensing system and analysis algorithm. Further study would be continued for more wide clinical studies with various environment noises. Based on this study, development of anti-snore pillow and sleep monitoring system for comfort sleep could be developed.

  • PDF

전간(癲癎)에 대(對)한 문헌적(文獻的) 고찰(考察) (고전(古典)을 중심(中心)으로)

  • Lee, Il-Rang;Kim, Yeong-Man
    • The Journal of Korean Medicine
    • /
    • v.1 no.1
    • /
    • pp.63-73
    • /
    • 1980
  • Through the classical records of the oriental medicine my investigation of the authorities of the epilepsy by classifying the etiology, symptoms and the treatments of it and camparing them has led to the following conclusion. 1) The etiology of 'epilepsy' can be classified into wind(風), sputum(痰), fever(熱) convulsion and caul. 2) The symptoms of it fall into the following nine ones; Sudden strong contraction making Sounds within the mouth, unoonsciousness, mutual jerks of the facial muscules foaming form the mouth, trismus contractive of extremities general body rigidity recovering after the fit and no rest. 3) The symptoms of Epilepsy are classified into 'Um type epilepsy'(癲) and the 'yang type epilepsy'(癎), and then the former has nine kinds in sympatomatic state and latter seventeen. 4) The treatment of the case can be made by using of cold drugs mainly for the purpose of mind purification(淸心), fever abatement(降火), Sputum-elimination(化痰) and normalization of metabolism(順氣) and Sometimes the function of the liver should be normalized by giving liver function normalizing medicine after Emetics. In comparison with the western way of using Anti convelsents therapy and electricshock therapy, the way of its treatment based on the classification of the causes is considered to be far more desirable.

  • PDF

Floor Impact Sound Isolation Performance by Composition of Ceiling and Wall (천장 및 벽구성 방법이 바닥충격음 차단성능에 미치는 영향에 관한 연구)

  • Kim Kyoung-Woo;Kang Jea-Sik;Lee Seung-Eon;Yang Kwan-Seop
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.4 s.97
    • /
    • pp.465-473
    • /
    • 2005
  • The impact sounds, generated by the walking of people, the dropping of an object or the moving of furniture, can be a source of great annoyance in residential buildings. The characteristics and level of this impact noise depends on the object striking the floor, on the basic structure of the floor, and on the finish materials of floor. The focus of this paper is to investigate the amount of improvement impact sound pressure level according to the change of the composition method of ceiling and wall. For this purpose, we tested impact sound pressure level of several cases which is the inserting of mineral wool, the increase of the thickness of air layer, the using of anti-vibration rubber in ceiling and attach the mineral wool on wall in the Floor Impact Sound Test Building of KICT. The results show that the composition method of ceiling and wall is more effective in the reduction of light weight impact sound specially in 125Hz and 250Hz.

Evaluation of Floor Impact Sound Performance according to the installation of Ceiling and Wall (천장 및 벽구성 방법에 따른 바닥충격음 특성평가)

  • Kim, Kyoung-Woo;Choi, Hyun-Jung;Yang, Kwan-Seop;Lee, Seung-Eon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.261-264
    • /
    • 2004
  • Impact sounds, such as those created by footsteps, the dropping of an object or the moving of furniture, can be a source of great annoyance in residential buildings. The character and level of impact noise generated depends on the object striking the floor, on the basic structure of the floor, and on the floor covering. This study base on the evaluate of isolation performance of impact sound according to the installation of ceiling and wall. In this test, we measured the reduction of impact sound in the case of inserting absorption materials, increasing of the thickness of air layer and using anti-vibration rubber in ceiling, install of absorption materials in wall. The results of this study show that treatment of ceiling and wall have some reduction of the light weight impact sound and heavy weight impact sound.

  • PDF

Diaphragmatic hernia in a Jeju horse (crossbred) broodmare

  • Yang, Jaehyuk;Koh, Yang-Nam;Hwang, Kyu-Kye;Lim, Yoon-Kyu
    • Korean Journal of Veterinary Research
    • /
    • v.49 no.4
    • /
    • pp.351-354
    • /
    • 2009
  • Diaphragmatic hernias, whether congenital or acquired (traumatic), are rarely observed in the horse. Acquired diaphragmatic hernias typically occur secondary to trauma or an increase in intraabdominal pressure due to falling, heavy exercise, or parturition. Diaphragmatic herniorrhaphy is difficult to perform in adult horses and the horses with symptomatic diaphragmatic hernias usually die. A 10- year old, 340 kg, Jeju horse (crossbred) broodmare with sudden onset of gait disorder and a moderate emaciation was examined. Findings on physical examination included conjunctivitis, dehydration, shallow breathing, dyspnea, weaken heart beat, lack of auscultatable sounds from the gastrointestinal tract, and anorexia. Rectal temperature was $38.4^{\circ}C$ and respiratory rates were moderately increased. There were slight signs of acute colic. The broodmare died one day after non-specific treatment of fluids, nutriment, antibiotics and non-steroidal anti-inflammatory drug. The cause of death was strangulation of the small intestine through a diaphragmatic hernia. The rent was about 2 cm in diameter and located in the central right part of diaphragm. Around 60 cm of small intestine was protruded into thoracic cavity through the rent. The cause of the hernia could not be ascertained. The broodmare had been pastured with many other horses, and the groom had not noticed any aggressive behavior among them. It was, however, speculated that trauma by stallion's attack may have been the cause of the diaphragmatic hernia, because the new horse may be the object of behaviors ranging from mild threats to seriously aggressive kicking, squealing, rearing, and biting.

Comparative evaluation of low-level laser therapy and ultrasound heat therapy in reducing temporomandibular joint disorder pain

  • Khairnar, Sanyukta;Bhate, Kalyani;Santhosh, Kumar S.N.;Kshirsagar, Kapil;Jagtap, Bhagyashree;Kakodkar, Pradnya
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.19 no.5
    • /
    • pp.289-294
    • /
    • 2019
  • Background: Pain, limitations in opening, asymmetrical jaw movements, and temporomandibular joint (TMJ) sounds are the most common findings in temporomandibular joint disorders (TMDs), which causes excruciating pain, inflammation of the surrounding muscles, posterior fibers, and synovial fluid. This study aimed to evaluate and compare the effects of ultrasound heat therapy and low-level laser therapy (LLLT) in reducing TMD-related pain. Methods: This prospective study included 42 patients (age range, 25-45 years), who were divided into two groups of 21 patients each. All patients were prescribed a non-steroidal anti-inflammatory drug (NSAID) twice a day for 5 days for temporary relief of pain prior to the commencement of treatment. Patients were kept on a soft diet and asked to restrict mouth opening during the same period. Fifteen sessions of LLLT (Group A) or ultrasound therapy (Group B) were administered to the affected side. Results: Post-therapy, the mean visual analog scale score for group A and group B was 4.81 (2.01) and 6.19 (1.20), respectively; the difference was statistically significant and favoring the LLLT group. Similarly, the mean mouth opening for group A and group B was 3.99 (0.40) and 3.65 (0.41), respectively; the difference was statistically significant and favoring the LLLT group. Conclusion: Our study recommends LLLT for treating TMD-related pain with no underlying bony pathology.