• Title/Summary/Keyword: Anti Vibration System

Search Result 131, Processing Time 0.026 seconds

A Study on the Dynamic Design of Anti-Vibration Structures for Nano-class Measuring System (나노 측정시스템을 위한 방진 구조물의 동적 설계에 관한 연구)

  • 전종균;김강부;백재호
    • Journal of the Semiconductor & Display Technology
    • /
    • v.2 no.3
    • /
    • pp.37-43
    • /
    • 2003
  • It is necessary to design the anti-vibration system of precision machinery for a quality assurance. However, in general, the allowable vibration limit is not well known. In this paper, the vibration criteria for foundation of sensitive machinery is proposed and anti-vibration system is designed by using vibration measurement results of foundation. Also, the finite element analysis is performed to verify the effectiveness of the designed anti-vibration system and to determine the allowable dynamic loads of precision measuring system. The results of this study will be helpful for the future design of anti-vibration structures with nano scale measuring system.

  • PDF

Development of the System for Measurement of the Vibration Transmissibility of an Anti-vibration Glove (방진 장갑 진동 전달률 측정 시스템 개발)

  • Choi, Seok-Hyun;Hong, Seok-In;Jang, Han-Kee;Park, Tae-Won
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.6 s.111
    • /
    • pp.602-608
    • /
    • 2006
  • In order to evaluate performance of anti-vibration gloves, it is necessary to measure the transmitted vibration to the hand and the applied forces at the same time while gripping the vibrating handle. In the study a system was developed to measure both the vibration and the forces. The system consists of a measurement handle with eight strain gauges and two accelerometers and a PC-based system with a software for signal processing and evaluation of the hand-transmitted vibration and for control of applied forces in the pre-determined range. The handle was installed on the vibration shaker which is strong enough so as not to be affected by dynamic coupling with the hand-arm system. Whole procedure of ISO 10819 to determine the vibration transmissibility of anti-vibration gloves was programmed into the system. As an example of the application, three subjects joined the test to get vibration transmissibilities of anti-vibration gloves where each glove was tested twice a subject. Average and standard deviation of vibration transmissibility were also calculated.

A Design of Active Vibration Control System Using Electromagnetic Actuators (전자기 액츄에이터를 이용한 진동제어시스템)

  • Lee, Joo-Hoon;Jeon, Jeong-Woo;Caraiani, Mitica;Kang, Dong-Sik
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.936-939
    • /
    • 2006
  • The pneumatic isolator is widely adopted for anti-vibration of precision measuring and manufacturing equipments. But, when the precision demand on anti-vibration is extreme or the load is moving, the performance of anti-vibration can not meet satisfaction. In these cases, as a complementary, active vibration suppression system can be added for advanced performance. In this paper, an active control system is presented, which uses electromagnetic actuators for vibration suppression. The anti-vibration characteristic of pneumatic isolator is analyzed for system modeling and actuator specifying. The modeling and the 3D dynamic simulation is performed for control system design. For the electromagnetic actuator design, the magnetic flex density and the current-force characteristic analysis are achieved.

  • PDF

Assessment of Anti-vibration Gloves for Reduction of Hand-transmitted Vibration Exposure (수전달 진동 피폭 저감을 위한 방진 장갑의 성능 평가)

  • Choi, Seok Hyun;Hong, Seok In;Jang, Han Kee
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.18 no.1
    • /
    • pp.1-10
    • /
    • 2008
  • In order to evaluate performance of anti-vibration gloves, it is necessary to measure the transmitted vibration to the hand and the applied forces at the same time while gripping the vibrating handle. In the study a system was developed to measure both the vibration and the forces. The system consists of a measurement handle with eight strain gauges and two accelerometers and a PC-based system with a software for signal processing, evaluation of the hand-transmitted vibration and for control of applied forces in the pre-determined range. The handle was installed on the vibration shaker which is strong enough so as not to be affected by dynamic coupling with the hand-arm. Whole procedure of ISO 10819:1996 to determine the vibration transmissibility of anti-vibration gloves was programmed into the system. As an example of the application, three subjects joined the test to get vibration transmissibilities of 9 anti-vibration gloves where each glove was tested twice a subject. Average and standard deviation of the corrected vibration transmissibility were also calculated. All tested gloves fulfilled criterion for M-spectrum($\overline{TR_M}$<1.0), but one glove fulfilled criterion for H-spectrum($\overline{TR_H}$<6.0),

Anti-vibration and Shock-resistant Design for Personal Navigation Device (PND 의 내진특성 개선)

  • Hwang, Hyo-Kune;Ha, Sang-Woo;Yoo, Seung-Hun;Choi, In-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.861-862
    • /
    • 2008
  • One of trend of portable devices is convergence with other devices, especially with navigation system. This converged system is generally called PND (Personal Navigation Device). This detachable device is developed for personal entertainment in everyday life and navigation system when deriving, so it should meet the specification of vehicle thermal environment, anti-vibration as well as the anti-shock by sudden drop. In this paper, the way to design the hard disk drive damper with CAE, is introduced to get a reliable system from the beginning of the design step.

  • PDF

A Study on the Dynamic Design of Structure for Sub-Vibration Control of Precision Measuring System (극 초정밀 측정시스템의 미진동제어를 위한 구조물의 동적 설계에 관한 연구)

  • 김강부;김현식;전종균;김기현
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.863-868
    • /
    • 2001
  • It is necessary to design th anti-vibration system of precision machinery for a sound operation and a quality assurance. However, in general. the allowable vibration limit is not well known. In the paper, the vibration criteria for foundation of vibration sensitive machinery is proposed and anti-vibration system is designed by using vibration measurement results of foundation. Also, the F.E. analysis is performed to verify the effectiveness of a designed anti-vibration system and to determine allowable dynamic load of machinery

  • PDF

VIBRATION CONTROL OF SYNCHROTRON LIGHT SOURCE BUILDING USING EXPERIMENTAL MODAL ANALYSIS (실험적 모우드 해석을 이용한 방사광 가속기 건물의 진동제어)

  • 박상규;이홍기;권형오
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1993.10a
    • /
    • pp.157-161
    • /
    • 1993
  • Optical devices and electronic equipments used in the laboratory of the synchrotron light source building of the accelerator have stringent vibration limits. In order to control the vibration of the building structure and HVAC systems which are main vibration sources are evaluated using experimental modal analysis. Double anti-vibration system is used for the HVAC system and results show that the double anti-vibration system reduces the vibrations of the building to acceptable levels.

  • PDF

Study on Performances of the Lever Type Anti-resonance Vibration Isolator (레버형 반공진 진동 절연기의 진동 특성 연구)

  • Yun, Jong-Hwan;Kim, Gi-Woo;Lee, Hyeongill
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.26 no.2
    • /
    • pp.187-194
    • /
    • 2016
  • Parametric study on the lever type dynamic anti-resonance vibration isolator (DAVI) is executed to introduce the system in the path of vibration transmission for the vibratory response attenuation. The effects of inertia and location of the lever on the system performances are investigated using FEA. The effects of other parameters such as ratio of lever lengths, ratio of masses and the location of pivot are studied with analytical approach. According to the results, all the parameters except lever location affect the system response in their own ways. Consequently, the optimal lever type DAVI for translational or rotational system can be efficiently designed by selecting system parameters using the procedure introduced in this study.

A Study on Dynamic Modeling of the Vibration Isolation System for the Ultra Precision Measurement (초정밀작업을 위한 제진시스템의 동역학 모델링 연구)

  • Son, Sung-Wan;Jang, Sung-Ho;Baek, Jae-Ho;Chun, Chong-Keun;Kwon, Young-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.1
    • /
    • pp.25-31
    • /
    • 2009
  • The anti-vibration tables that use air suspensions as dampers have been widely used due to their high anti-vibration performance in wide frequency band. However, they face a problem of easily accelerating the vibration when triggered by external force because their air suspensions have low rigidity and dampness. In response, there has been a study on active/semi-active dampers that use only the passive components like air suspensions to complement the passive-control format. Thus, we have dynamically analyzed the active/semi-active control of such passive anti-vibration tables. To demonstrate the anti-vibration table's control system, we have also constructed a kinetic model based on the physical characteristics of an anti-vibration table with 6 degrees of freedom and verified its applicability through analysis and experiments.

Acoustic resonance by Inserting Anti-noise Baffle in the Tube Bank of Boiler of a Large Fossil Power Plant (대형석탄화력발전용 보일러 관군의 Anti-Noise Baffle 설치에 따른 음향공진)

  • Bang, Kyung-Bo;Kim, Cheol-Hong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.178-183
    • /
    • 2004
  • This paper presents phenomena of vibration and noise due to acoustic resonance in tube bank of a large fossil power plant. The phenomena of acoustic resonance may arise when the vortex shedding frequency coincides with the acoustic natural frequency. In this system dominant frequency of vibration and noise was 37.5Hz. The $3^{rd}$ acoustic natural frequency calculated was 37.2 Hz. When the difference of vortex shedding frequency and acoustic natural frequency is within ${\pm}20%$, acoustic resonance could occur. If system is the state of acoustic resonance, vibration and noise become large. In order to prevent acoustic resonance, anti-noise baffle should be installed in the tube bank. In the case of installing baffle, we should consider the number of baffle and the effect of acoustic mode due to baffle extension length. To do this, we did acoustic mode analysis. After installing anti-noise baffle, acoustic resonance was disappeared and vibration magnitude and noise level was reduced dramatically.

  • PDF