• 제목/요약/키워드: Anti Vibration Bar

검색결과 17건 처리시간 0.024초

고능률 방진 보링바 개발에 관한 연구 (A Study on the Development of High Efficiency Anti-Vibration Boring Bar)

  • 최춘규;이우영;최성주;이동주
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1995년도 추계학술대회 논문집
    • /
    • pp.109-112
    • /
    • 1995
  • This paper analyzes high efficiency anti-vibration boring bars which increase stability against chatter vibration in boring operations. Structural analysis and mathematical modeling with considering dynamic properties for three types of existing boring bars are performed to search for optimal design parameters. The purpose of this paper is to find out design parameters for high efficiency anti-vibration boring bar.

  • PDF

앤티롤바의 취부위치에 따른 철도차량의 실내소음에 대한 연구 (The study of the effects to the structure borne noise in terms of the Anti-Roll Bar's mounting position)

  • 박희준;우관제
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.1794-1798
    • /
    • 2008
  • Inside noise level of a running train in open field is the summation of air borne noise and structure-borne noise. Anti-roll bar is the major transmission path of vibration from bogie. And this vibration gives an effect to the structure borne noise. In this paper, the effect of anti-roll bar is investigated. Structure borne noise is analyzed in terms of changing the mounting position of anti-roll bar to reduce inside noise levels.

  • PDF

증기발생기 세관과 지지대 간극을 고려한 마모량 예측 방법론 (Methodology for Wear Prediction Considering the Gap between Tube and Support/Anti-vibration-bar in the Steam Generator)

  • 이용선;박치용;김태순;부명환
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.84-89
    • /
    • 2004
  • When the tube contacted to support, anti-vibration bar of the steam generator in nuclear power plant, the contact area is worn out by their relative displacement and contact force. Connors and Au-Yang found the relation between tube worn displacement and volume, or normal work rate at given gap size. The present analysis is obtained the relation between tube worn displacement and normal work rate at various gap size modifying Au-Yang's result. The results are compared with Connors and Yettisir and Pettigrew's results. The comparison shows that Yettisir and Pettigrew result is fairly good agreement with Connors and present results with gap clearance, 0.015in.

  • PDF

간극효과를 고려한 증기발생기 전열관의 3차원 유한요소해석 (3-D Finite Element Analyses of Steam Generator Tubes Considering the Gap Effects)

  • 조영기;박재학
    • 한국압력기기공학회 논문집
    • /
    • 제7권4호
    • /
    • pp.51-56
    • /
    • 2011
  • Steam generator is one of the main equipments that affect safety and long term operation in nuclear power plants. Fluid flows inside and outside of the steam generator tubes and induces vibration. To prevent the vibration the tubes are supported by AVB (anti vibration bar). When the steam generator tube contact to AVB, it is damaged by the accumulation of wear and corrosion. Therefore studies are required to determine the effects of the gap between the steam generator tube and AVB. In order to obtain the stress and the displacement distributions of the steam generator tube, three dimensional finite element analyses were performed by using the commercial program ANSYS. Using the calculated the stress and the displacement distributions, the static residual strength of the steam generator tube can be evaluated. The results show that the stress and displacement of the steam generator tube increase significantly compared with the results from a zero-gap model.

콘테이너 크레인의 헤드블록 횡동요 해석 (Swing Motion Analysis of the Container Crane Headblock)

  • 조대승
    • 소음진동
    • /
    • 제7권5호
    • /
    • pp.765-772
    • /
    • 1997
  • This paper presents the swing motion analysis of the container crane headblock with the passive control device using hydraulic motors and anti-swing ropes. The device hauls at the headblock to opposite direction of its swing motion using the tension difference between anti-swing ropes connected to the headblock. To consider this control mechanism, the headblock is modelled as the rigid bar suspended by two hoist ropes at the overhead trolley and its non-linear equation of motion is derived using Lagrange's equation. Some numerical experiments using the equation are carried out to investigate the swing motion characteristics of the headblock under the variation of geometric relation among the cargo handling components and to evaluate the performance of the anti-swing device.

  • PDF

콘테이너 크레인의 헤드블록 횡동요 해석 (Swing Motion Analysis of the Container Crane Headblock)

  • 조대승
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1997년도 춘계학술대회논문집; 경주코오롱호텔; 22-23 May 1997
    • /
    • pp.153-159
    • /
    • 1997
  • This paper presents the swing motion analysis of the container crane headblock with the passive control device using hydraulic motors and anti-swing ropes. The device hauls at the headblock to opposite direction of its swing motion using the tension difference between anti-swing ropes connected to the headblock. To consider this control mechanism, the headblock is modelled as the rigid bar suspended by two hoist ropes at the overhead trolley and its non-linear equation of motion is derived using Lagrange's equation. Some numerical experiments using the equation are carried out to investigate the swing motion characteristics of the headblock under the variation of geometric relation among the cargo handling components and to evaluate the performance of the anti-swing device.

  • PDF

Fluid-elastic Instability Evaluation of Steam Generator Tubes

  • Cho, Young Ki;Park, Jai Hak
    • International Journal of Safety
    • /
    • 제11권1호
    • /
    • pp.1-5
    • /
    • 2012
  • It has been reported that the plugged steam generator tube of Three Mile Island Unit 1 in America was damaged by growing flaw and then this steam generator tube destroyed the nearby steam generator tubes of normal state. On this account, stabilizer installation is necessary to prevent secondary damage of the steam generator tubes. The flow-induced vibration is one of the major causes of the fluid-elastic instability. To guarantee the structural integrity of steam generator tubes, the flow-induced vibration caused by the fluid-elastic instability is necessary to be suppressed. In this paper, the effective velocity and the critical velocity are calculated to evaluate the fluid-elastic instability. In addition, stability ratio value of the steam generator tubes is evaluated in order to propose one criterion when to determine stabilizer installation.

확폭교량 RC 상판의 피로거동에 관한 연구 (A Study on the Fatigue Behavior of RC Slabs of Widened Bridges)

  • 홍순길;장동일
    • 콘크리트학회지
    • /
    • 제6권6호
    • /
    • pp.143-150
    • /
    • 1994
  • 교량의 확폭공사에는 대개 기설부와 신설부 교량을 일체화시키는 접합시공법이 행해지고 있다. 그러나 접합시공법은 설계 및 시공상 여러 가지 복합적인 문제를 야기시킨다. 본 연구는 피로실험을 통하여 접합시공에 따른 제반 문제점중 확폭교량 시공방법에 따른 휨피로거동과 콘크리트 양생시 기설부 교량을 통과하는차량에 의해 발생하는 진동이 신설부 교량에 미치는 영향을 조사하고자 실시하였다. 연구결과, 초기에 접합부 철근에서 약간을 응력집중현상 및 철근과 콘크리트간에 슬립현상이 관찰되었으나 전체적인 거동은 유사하였으며, 무수축합시공법이 신설부 교량의 콘크리트 양생중 발생하는 진동의 영향을 완화시킬 수 있음을 알 수 있었다.

다경간 전열관의 난류 가진에 의한 마모특성 연구 (Wear Characteristics of Multi- span Tube Due to Turbulence Excitation)

  • 김형진;성봉주;박치용;유기완
    • 한국소음진동공학회논문집
    • /
    • 제16권9호
    • /
    • pp.904-911
    • /
    • 2006
  • A modified energy method for the fretting wear of the steam generator tube is proposed to calculate the wear-out depth between the nuclear steam generator tube and its support. Estimation of fretting-wear damage typically requires a non-linear dynamic analysis with the information of the gap velocity and the flow density around the tube. This analysis is very complex and time consuming. The basic concept of the energy method is that the volume wear rate due to the fretting-wear phenomena Is related to work rate which is time rate of the product of normal contact force and sliding distance. The wearing motion is due to dynamic interaction between vibrating tube and its support structure, such as tube support plate and anti-vibration bar. It can be assumed that the absorbed work rate would come from turbulent flow energy around the vibrating tube. This study also numerically obtains the wear-out depth with various wear topologies. A new dissection method is applied to the multi-span tubes to represent the vibrational mode. It turns out that both the secondary side density and the normal gap velocity are important parameters for the fretting-wear phenomena of the steam generator tube.

Corrosive Wear of Alloy 690 Tubes in Alkaline Water

  • Hong, Seung Mo;Jang, Changheui;Kim, In Sup
    • Corrosion Science and Technology
    • /
    • 제8권3호
    • /
    • pp.126-131
    • /
    • 2009
  • The interaction between wear and corrosion can significantly increase total material losses in water chemistry environment. The corrosive wear tests of a PWR steam generator tube material (Alloy 690) against the anti vibration bar material (409 SS) were performed at room temperature. The tests were performed in alkaline water chemistry conditions. NaOH solution was selected for test condition to investigate the corrosive wear effect of steam generator tube material in alkaline pH condition without other factors. The flow induced vibration can caused tube damage and the corrosion can be occurred by water chemistry. The test results showed that, in the alkaline solution at pH 13.9, the corrosion current density was increased about ten times than that in the distilled water. And wear rate at pH 13.9 was increased about ten times from that at neutral condition. However, the wear rate was decreased with time. The decrease would be attributed to the change in roughness of specimen or sub-layer of the worn surface with time. From microstructure observation, severe abrasive shape and several wear debris were found. From those results, it could infer that the oxide film on Alloy 690 changed to easily breakable one in the alkaline water, and then abrasion with corrosion became the main wear mechanism.