• 제목/요약/키워드: Anthropometry

검색결과 365건 처리시간 0.028초

구순열비 석고모형에서 간접인체계측법: 직접인체계측법과의 비교 (Indirect Anthropometry on Cast Model of Cleft Lip Nose: Comparison with Direct Anthropometry)

  • 한기환;정회준;진현석;김준형;손대구
    • Archives of Plastic Surgery
    • /
    • 제34권1호
    • /
    • pp.18-23
    • /
    • 2007
  • Purpose: Anthropometry can be divided into two methods, direct anthropometry and indirect anthropometry. The most ideal and accurate method is a direct anthropometry. However, it is difficult to measure in the case of children because of poor cooperation, and it lacks re-productivity. Cast model has advantages of three dimensional featuring, inexpensive and easy fabrication. This study is conducted to find out an accuracy of indirect anthropometry on cast model by comparing it with direct anthropometry. Methods: Total 48 cleft lip nasal deformity patients (unilateral, 40; bilateral, 8) were included in this study. Cast models were made before surgery under general anesthesia with alginate impression material and model plaster. Eleven linear measurements among 7 landmarks were taken as direct anthropometry before surgery with Castroviejo spreading caliper. At the same time, indirect anthropometry on cast model was done at the same linear distances as well. Results: Of the total 11 linear measurements, both ala lengths, both columella lengths, nose width, projective distance between facial insertion points of the ala, projective distance between the alar base points, right nostril floor width, and columella width were statistically correlated between indirect anthropometry on cast model and direct anthropometry. However, the nasal tip protrusion and the left nostril floor width were not statistically correlated. Conclusion: Accuracy of indirect anthropometry on cast model can be influenced by cast model fabrication techniques and correct identification of landmarks. Nasal tip protrusion could be reduced by compression of the nasal tip in the process of cast model fabrication and nostril floor width can be varied by muscle relaxation of anesthetics and incorrect identification of subalare in cleft lip nasal deformity. If sufficient care is taken to make cast model and to define landmarks exactly, indirect anthropometry on cast model can be a reliable method as direct anthropometry.

코 석고모형에서 간접인체계측법의 정확성 : 직접인체계측법과의 비교 (Accuracy of Indirect Anthropometry on Cast Model of The Nose: Comparison with Direct Anthropometry)

  • 백대향;한기환;원동철;최태현;김준형;손대구
    • Archives of Plastic Surgery
    • /
    • 제35권1호
    • /
    • pp.48-55
    • /
    • 2008
  • Purpose: We measured linear distances, angles and inclinations on the cast models of the noses, and compared these indirect measurements with the direct measurements obtained from the nose in order to validate the accuracy of the indirect anthropometry using the cast model. Methods: Subjects were 50 males and 50 females, medical students in twenties(mean 27.1 years). Cast models were made from the alginate impression material and the plaster. In direct anthropometry, 16 linear, 7 angular, and 2 inclination measurements between 11 landmarks on the nose were obtained using sliding caliper, spreading caliper, and fabric tape measure. At the same time, the same measurements were obtained from the cast models of the same people. Total 25 measurements were compared, and tested by the independent t-test of SPSS. Results: The standard values of Korean nose in twenties were obtained. 24 measurements except the columellar labial angle were not statistically different between the indirect anthropometry and the direct anthropometry. Conclusion: Indirect anthropometry on the cast model of the nose revealed no significant difference from the anthropometric measurement statistically, accounting for 24 in 25 measurements(96%). There are two possible reasons that caused the difference of columellar labial angle between direct and indirect anthropometry. First, the columellar labial angle could be decreased by protrusion of the lips which resulted from contracting mouth in which an drinking straw had been applied on the mouth corner for patients' respiration during making cast model. Second, it is generally known that the columellar labial angle could be measured larger when soft tissues were pressed by protractor in direct anthropometry. Using a drinking straw with greater diameter, and scheming respiration through the nostrils that patients don't feel discomfort, the more accurate data would be obtained from the indirect anthropometry using the cast models of the noses.

한열변증과 체형 및 체성분의 연관성 분석 - 50세 이상 장년 및 노년층을 대상으로 (Association of Cold-heat Pattern and Anthropometry/body Composition in Individuals Between 50-80 Years of Age)

  • 문수정;박기현;이시우
    • 동의생리병리학회지
    • /
    • 제34권4호
    • /
    • pp.209-214
    • /
    • 2020
  • The association of cold-heat (CH) pattern and anthropometry/body composition has been suggested in that they are related to thermoregulation. We aimed to study the association of CH pattern and anthropometry/body composition. A total of 1479 individuals aged 50-80 years were included in the study, and their CH pattern were evaluated by a self-administered questionnaire. After adjustment for age and sex, the CH score were significantly correlated with weight, BMI (body mass index), body surface area, waist-hip ratio, fat free mass, body fat mass, body cell mass, intracellular water, extracellular water, and basal metabolic rate; however, the correlation coefficients were mostly low (0.15-0.24). The selected variables for predicting CH score were various according to the methods used for variable selection; however, the adjusted R-squared of the final models were all around 0.12. Thus the most parsimonious model could be the one that includes sex and BMI. In conclusion, various anthropometry and body composition indices were associated with CH pattern. Future studies are necessary to improve the performance of the prediction model.

인체정보 DB의 경제적인 조합을 통한 골프 스윙 동작 분석용 3D 캐릭터 모델링 (The 3D Character Modeling for Golf Swing Motion Analysis by Economical Verification of Body Information)

  • 곽현민;채균식;박찬종;이상태
    • 감성과학
    • /
    • 제6권2호
    • /
    • pp.59-64
    • /
    • 2003
  • 우리나라의 국민표준체위조사는 1979년 1차 조사를 시작으로 약 5∼6년 주기로 실시되고 있으며, 1997년 제4차 조사가 실시되었다. 국민표준체위조사 결과를 기반으로 한 인체측정치는 의류, 신발, 가구 등 관련산업의 제품설계에 반영되었다. 본 논문에서는 국민표준체위조사 결과자료를 기본으로 성별, 연령별, 체형별로 사용자를 분류한 후 체형별 분류를 위한 인체측정치를 도출하였다 도출된 인체측정치의 상관관계를 분석, 대표적인 항목 도출 등의 과정을 통하여 3D 캐릭터를 구성하였다. 구성을 위한 과정으로 골프, 테니스 등의 스포츠 동작을 효율적으로 나타낼 수 있는 인체 측정치를 도출하였다. 항목이 결정되면 각 타입의 3D 캐릭터를 구성할 수 있는 치수를 제시하여 생성하였다. 스포츠의 자세 및 동작분석에 대한 이론적 접근에서 가시적인 정보제공 및 자세ㆍ동작분석 프로토콜을 개발함으로써 자세 및 동작에 대한 정량적ㆍ객관적 평가가 가능해졌다.

  • PDF

Validation of a new three-dimensional imaging system using comparative craniofacial anthropometry

  • Naini, Farhad B.;Akram, Sarah;Kepinska, Julia;Garagiola, Umberto;McDonald, Fraser;Wertheim, David
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제39권
    • /
    • pp.23.1-23.8
    • /
    • 2017
  • Background: The aim of this study is to validate a new three-dimensional craniofacial stereophotogrammetry imaging system (3dMDface) through comparison with manual facial surface anthropometry. The null hypothesis was that there is no difference between craniofacial measurements using anthropometry vs. the 3dMDface system. Methods: Facial images using the new 3dMDface system were taken from six randomly selected subjects, sitting in natural head position, on six separate occasions each 1 week apart, repeated twice at each sitting. Exclusion criteria were excess facial hair, facial piercings and undergoing current dentofacial treatment. 3dMDvultus software allowed facial landmarks to be marked and measurements recorded. The same measurements were taken using manual anthropometry, using soluble eyeliner to pinpoint landmarks, and sliding and spreading callipers and measuring tape to measure distances. The setting for the investigation was a dental teaching hospital and regional (secondary and tertiary care) cleft centre. The main outcome measure was comparison of the craniofacial measurements using the two aforementioned techniques. Results: The results showed good agreement between craniofacial measurements using the 3dMDface system compared with manual anthropometry. For all measurements, except chin height and labial fissure width, there was a greater variability with the manual method compared to 3D assessment. Overall, there was a significantly greater variability in manual compared with 3D assessments (p < 0.02). Conclusions: The 3dMDface system is validated for craniofacial measurements.

머리고정기(Cephalostat)를 이용한 표준임상사진술에서 사진계측법: 인체계측법과의 비교 (Photogrammetry Based on Standardized Clinical Photography using Cephalostat: Comparison with Anthropometric Analysis)

  • 권혁준;한기환;김준형;손대구
    • Archives of Plastic Surgery
    • /
    • 제34권1호
    • /
    • pp.24-36
    • /
    • 2007
  • Purpose: Direct anthropometry is an ideal method for preoperative planning and postoperative evaluation in plastic surgery, but it requires highly skilled specialty. Indirect anthropometry, especially photogrammetry, is an alternative method. In photogrammetry, standardized clinical photography is essential. Photogrammetry-based standardized clinical photography has several advantages over direct anthropometry. It is easier to measure and has less chance to make errors during measurement. Furthermore, it is possible to repeat measurements, and available for follow up study based on permanent custody. But, it is still different from actual measurement, and inherently less accurate than anthropometry. Methods: The authors revised the standardized clinical photography and then, carried out photogrammetry using Photoshop(Adobe, U.S.A.), and compared each data with those of anthropometry. The subjects were 50 males and 50 females, undergraduate medical students in twenties. Standard head position was obtained from the wire, fixed to cephalostat which indicates the Frankfort horizontal plane. All photographs were taken at the same situation such as fixed position of light, subject and camera, etc. Results: Total 96 measurements, based on 40 landmarks, consist of linear measurements, angular measurements and inclinations include 3 measurements in head, 22 in face, 15 in orbit, 28 in nose, 16 in lip and mouth, and 12 in ear. Conclusion: Normal photogrammetric data of face of Korean in twenties was obtained. Reliable photogrammetric measurements, not significantly different from anthropometric measurement statistically, accounted for 44 in 96 measurements(45.8%). Anthropometric values different from those of photogrammetric values were obtained by multiplying coefficient by photogrammetric value.

Relationship between Representative Anthropometric Dimensions and Income Levels for Korean

  • Kee, Do-Hyung
    • 대한인간공학회지
    • /
    • 제31권1호
    • /
    • pp.255-259
    • /
    • 2012
  • Objective: This study aims to investigate relationship between representative anthropometric dimensions and income levels for Korean from 1958 to 1989. The anthropometric dimensions include stature and body weight, and GNP per head was used as an index of income level. Background: Although anthropometric dimensions were affected by varying factors such as genetic, environmental and socioeconomic factors, most studies on anthropometry have focused on measurement methods, providing data and their characteristics. Method: Anthropometric data were retrieved from homepages of Korean Agency for Technology and Standards, and Ministry of Culture, Sports & Tourism, and GNPs per head by year from Korean Statistical Information Service. Results: During analysis period, statures and body weights for males and females increased by 6.4cm and 6.1cm, 10.7kg and 4.0kg, respectively. Infants' stature and body weight nearly linearly increased with GNPs per head. Anthropometric dimensions of stature and body weight were very positively correlated with GNPs per head. Conclusion: This study revealed that income levels significantly affect stature and body weight. Application: The results would be used as a valuable basic data when establishing government policies related to anthropometry.

Ergonomic Evaluation of Biomechanical Hand Function

  • Lee, Kyung-Sun;Jung, Myung-Chul
    • Safety and Health at Work
    • /
    • 제6권1호
    • /
    • pp.9-17
    • /
    • 2015
  • The human hand is a complex structure that performs various functions for activities of daily living and occupations. This paper presents a literature review on the methodologies used to evaluate hand functions from a biomechanics standpoint, including anthropometry, kinematics, kinetics, and electromyography (EMG). Anthropometry describes the dimensions and measurements of the hand. Kinematics includes hand movements and the range of motion of finger joints. Kinetics includes hand models for tendon and joint force analysis. EMG is used on hand muscles associated with hand functions and with signal-processing technology.

한국인의 신체특성과 표준 안전간극 및 안전거리 (Anthropometry of Korean People and Safety Reach Standards)

  • 김주홍;김동하;임현교
    • 한국안전학회지
    • /
    • 제8권4호
    • /
    • pp.189-193
    • /
    • 1993
  • Elimination of dangerous points is the most effective method for safety in mechanical equipments. The next effective method is recognized as isolation and/or safe-guarding of dangerous spots from human beings. With progress of mechanical automation technique such as industrial robots, the need for safe-guard-ins is now being enlarged. It is needless to say that when a machine-guard is designed and installed, a comprechensive understanding of human movement is indispensable. But in this country, there is no scientific for those thems, and no one verifield whether it is valid to apply general guideline such as OSHA's to Korean or not. Further, basic anthropometric items for safety reach standards are neither availble nor included in nation-wide anthropometry project. In this research, human anthropometry data of Korean youngsters are analyzed for safety barrier and safety slit width, and compared with guidelines of other countries-Germany, United Kingdom, Japan, and USA. Though they are standards for safety, since they are based upon their own peoples' data, some of them especially foot reach are not not applicable in this country. It should be notified that careful application of numeric value is very important.

  • PDF