• Title/Summary/Keyword: Anterior screw fixation

Search Result 93, Processing Time 0.023 seconds

Long-term Effects on the Cervical Spine after Anterior Locking Plate Fixation (경추 전방 잠금식 금속판이 장기적으로 경추에 미치는 영향)

  • Kim, Keun Su
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.4
    • /
    • pp.493-500
    • /
    • 2001
  • Objective : Anterior cervical locking plates are the devices for achieving anterior cervical spinal fusion. This study was conducted to evaluate the locking plate system regarding its long-term advantages and disadvantages in the view of interbody fusion rate, hardware-related failures, vertebral change close to the fusion segment and postoperative complications. Method : Eight-six patients, operated from Jan., 1996 to Jun. 1998, were followed-up for more than two years. All of the cases were fused with iliac bone graft and ORION locking plate(Sofamor Danek USA, Inc., Memphis, TN) fixation. The patients were discharged or transferred to rehabilitation department 2-7 days after operation. A comprehensive evaluation of the interbody fusion state, instrument failure, vertebral change and postoperative complications were made by direct interview and cervical flexion-extension lateral plain films. Results : There were 55 male and 31 female with a mean age of 45 years(18-75 years). The mean follow-up period was 29 months(24-43 months). Various disorders that were operated were 40 cervical discs, 6 cervical stenosis including OPLL, 2 infections, and 38 traumas. Fusion level was single in 59 cases, two levels of each disc space in 15 cases, and two levels after one corpectomy in 12 cases. There was no instrument failure. Pseudoarthrosis was observed in two cases(2%) without radiological instability. The other patients(98%) showed complete cervical fusion with stable instrument. Mild settling of interbody graft with upward migration of screws was found in 12 cases(14%). Anterior bony growth at the upper segment was found in 5 cases(6%). Postoperative foreign body sensation or dysphagia was observed in 12 cases(4%), and disappeared within one month in 7 cases and within six months in 4 cases. One patient complained for more than six months and required reoperation to remove paraesophageal granulation tissue. Conclusion : The results show that Orion cervical locking plate has some disadvantages of upward migration of screws, anterior bony growth at the upper segment, or possibility of esophageal compression even though it has advantages of high interbody fusion rate or low instrument failure. Author believe that anterior cervical locking plate in the future should be thinner, and should have short end from the screw hole, and movable screw with adequate stability.

  • PDF

Cross-Pin and Interference Screw Femoral Fixation in Anterior Cruciate Ligament Reconstruction using Hamstring Tendon -Technical Note- (슬괵건을 이용한 전방십자인대 재건술시 횡고정 핀과 간섭나사를 이용한 대퇴터널 고정술 -수술 수기-)

  • In Yong;Bahk Won-Jong;Park Jong-Beom;Hong Seung-Hwan
    • Journal of the Korean Arthroscopy Society
    • /
    • v.6 no.1
    • /
    • pp.60-63
    • /
    • 2002
  • Purpose : The purpose of this study was to introduce new femoral fixation technique using a cross-pin and a bioabsorbable interference screw in hamstring ACL reconstruction. Method : Semitendinosus and gracilis were harvested for quadrapled graft. After tibial tunnel had been made, femoral tunnel was made 35 mm in depth. Then the graft passed through the tunnels. Cross-pin was fixed through the drill hole which had been made through upper sleeve of the Rigidfix system. While pulling the graft, bioabsorbable interference screw was fixed through the anteromedial portal. Conclusion : We introduced the new femoral fixation technique using a cross-pin and a bioabsorbable interference screw as a good method with high fixation strength and tight graft-bone contact.

  • PDF

Pretibial cyst after Arthroscopic Anterior Cruciate Ligament Reconstruction using Hamstring Autograft - A Case Report - (자가 슬괵근을 이용한 전방 십자 인대 재건술 후 발생한 전경골 낭종 - 증례 보고 -)

  • Seo, Seung-Suk;Kim, Chang-Wan;Ha, Dong-Jun;Jung, Hun-Jae
    • Journal of the Korean Arthroscopy Society
    • /
    • v.13 no.1
    • /
    • pp.53-57
    • /
    • 2009
  • The pretibial cyst is a very rare complication after anterior cruciate ligament (ACL) reconstruction. It occurs whatever kind of graft choice or kind of graft fixation method at tibial side. It have been known such as graft necrosis at tibial side, extra-articular leakage of joint fluid through tibial tunnel, foreign body reaction due to breakdown of the bioabsorbable screw and incomplete incorporation of graft to bony tunnel as the cause of pretibial cyst. We experienced one case of pretibial cyst which had undergone ACL reconstruction with autogenous hamstring graft fixed with biodegradable interference screw. We report a rare case of pretibial cyst with literature review.

  • PDF

Bone Cement Augmentation of Short Segment Fixation for Unstable Burst Fracture in Severe Osteoporosis

  • Kim, Hyeun-Sung;Park, Sung-Keun;Joy, Hoon;Ryu, Jae-Kwang;Kim, Seok-Won;Ju, Chang-Il
    • Journal of Korean Neurosurgical Society
    • /
    • v.44 no.1
    • /
    • pp.8-14
    • /
    • 2008
  • Objective : The purpose of this study was to determine the efficacy of short segment fixation following postural reduction for the re-expansion and stabilization of unstable burst fractures in patients with osteoporosis. Methods : Twenty patients underwent short segment fixation following postural reduction using a soft roll at the involved vertebra in cases of severely collapsed vertebrae of more than half their original height. All patients had unstable burst fracture with canal compromise, but their motor power was intact. The surgical procedure included postural reduction for 2 days and bone cement-augmented pedicle screw fixations at one level above, one level below and the fractured level itself. Imaging and clinical findings, including the level of the vertebra involved, vertebral height restoration, injected cement volume, local kyphosis, clinical outcome and complications were analyzed. Results : The mean follow-up period was 15 months. The mean pain score (visual analogue scale) prior to surgery was 8.1, which decreased to 2.8 at 7 days after surgery. The kyphotic angle improved significantly from $21.6{\pm}5.8^{\circ}$ before surgery to $5.2{\pm}3.7^{\circ}$ after surgery. The fraction of the height of the vertebra increased from 35% and 40% to 70% in the anterior and middle portion. There were no signs of hardware pull-out, cement leakage into the spinal canal or aggravation of kyphotic deformities. Conclusion : In the management of unstable burst fracture in patients with severe osteoporosis, short segment pedicle screw fixation with bone cement augmentation following postural reduction can be used to reduce the total levels of pedicle screw fixation and to correct kyphotic deformities.

Biomechanical Comparison of Inter-fragmentary Compression Pressures : Lag Screw versus Herbert Screw for Anterior Odontoid Screw Fixation

  • Park, Jin-Woo;Kim, Kyoung-Tae;Sung, Joo-Kyung;Park, Seong-Hyun;Seong, Ki-Woong;Cho, Dae-Chul
    • Journal of Korean Neurosurgical Society
    • /
    • v.60 no.5
    • /
    • pp.498-503
    • /
    • 2017
  • Objective : The purpose of the present study was to compare inter-fragmentary compression pressures after fixation of a simulated type II odontoid fracture with the headless compression Herbert screw and a half threaded cannulated lag screw. Methods : We compared inter-fragmentary compression pressures between 40- and 45-mm long 4.5-mm Herbert screws (n=8 and n=9, respectively) and 40- and 45-mm long 4.0-mm cannulated lag screws (n=7 and n=10, respectively) after insertion into rigid polyurethane foam test blocks (Sawbones, Vashon, WA, USA). A washer load cell was placed between the two segments of test blocks to measure the compression force. Because the total length of each foam block was 42 mm, the 40-mm screws were embedded in the cancellous foam, while the 45-mm screws penetrated the denser cortical foam at the bottom. This enabled us to compare inter-fragmentary compression pressures as they are affected by the penetration of the apical dens tip by the screws. Results : The mean compression pressures of the 40- and 45-mm long cannulated lag screws were $50.48{\pm}1.20N$ and $53.88{\pm}1.02N$, respectively, which was not statistically significant (p=0.0551). The mean compression pressures of the 40-mm long Herbert screw was $52.82{\pm}2.17N$, and was not statistically significant compared with the 40-mm long cannulated lag screw (p=0.3679). However, 45-mm Herbert screw had significantly higher mean compression pressure ($60.68{\pm}2.03N$) than both the 45-mm cannulated lag screw and the 40-mm Herbert screw (p=0.0049 and p=0.0246, respectively). Conclusion : Our results showed that inter-fragmentary compression pressures of the Herbert screw were significantly increased when the screw tip penetrated the opposite dens cortical foam. This can support the generally recommended surgical technique that, in order to facilitate maximal reduction of the fracture gap using anterior odontoid screws, it is essential to penetrate the apical dens tip with the screw.

Cortical lag screw fixation for the management of mandibular injuries

  • Elsayed, Shadia Abdel-Hameed
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.46 no.6
    • /
    • pp.393-402
    • /
    • 2020
  • Objectives: Here, we present cases of mandibular fracture that were managed with the cortical lag screw fixation technique (CLSFT) in order to critically evaluate technique indications and limitations of application at various fracture sites. Materials and Methods: This was a retrospective cohort study. The study sample was composed of patients suffering from mandibular fractures that were treated by the CLSFT. The outcome variables were fracture type, duration of surgery, number of screws, and pattern of application. Other study categories included patient demographics and causes of injury. Chi-square tests were used to assess descriptive and inferential statistical differences, and the P-value was set at 0.05. Results: Thirty-three patients were included in the study sample, with a mean age of 30.9±11.5 years and a male predominance of 81.8%. The technique was applied more frequently in the anterior mandibular region (51.5%) than in other sites. Double CLSFT screws were required at the symphysis and parasymphysis, while single screws were used for body and angle regions. No intraoperative and postoperative variables were significantly different except for surgical duration, which was significantly different between the sites studied (P=0.035). Conclusion: We found that CLSFT is a rapid, cost-effective technique for the fixation of mandibular fractures yielding good treatment results and very limited complications. However, this technique is sensitive and requires surgical expertise to be applied to mandibular fractures that have specialized characteristics.

Comparison of F Calcaneal Plate and Locking Calcaneal Plate Fixation Using an Lateral Extensile Approach to Intra-articular Calcaneal Fractures (종골의 관절 내 골절에서 외측 광범위 도달법을 이용한 F형 금속판 고정술과 잠김 금속판 고정술의 비교)

  • Lee, Yun-Tae;Oh, Hyun-Cheol;Yoon, Han-Kook;Jang, Jae-Won;Jang, Ki-Jun
    • Journal of Korean Foot and Ankle Society
    • /
    • v.16 no.3
    • /
    • pp.175-180
    • /
    • 2012
  • Purpose: To evaluate the radiological and clinical results after open reduction and internal fixation with calcaneal F plate and locking calcaneal plate using lateral extensile approach in the treatment of intra-articular calcaneal fracture Materials and Methods: This study included 34 cases of 33 patients followed up for at least 6 months postoperatively. F plate was applied in 18 cases (Group 1), locking plate was used in 16 cases (Group 2) and compared radiological and clinical results between two groups. Results: Radiollogically, the mean Bohler angle was improved from $5.5^{\circ}$ preoperatively to $20.1^{\circ}$ postoperatively and $18.8^{\circ}$ at the last follow up in group 1 and $8.6^{\circ}$ preoperatively, $21.4^{\circ}$ postoperatively and $20.3^{\circ}$ at last follow up in group 2. Bone union was observed in all cases and 4 cases of screw loosening were noted in Group 1 with extended fracture to anterior process. At the last follow up, both groups showed clinical results in American orthopedic foot and ankle society ankle hindfoot score, 76(77 in Sanders type II and 75 in type III) in group 1 and 72(73 in type II and 70 in type III) in group 2. Conclusion: F plate and locking plate showed firm fixation and satisfactory clinical results in the treatment of intra-articular calcaneal fracture. We suggest applying locking plate in cases with extended fracture to anterior process, considering screw loosenings in those who were treated with F plate fixation.

Radiographic Comparison of Four Anterior Fusion Methods in Two Level Cervical Disc Diseases : Autograft Plate Fixation versus Cage Plate Fixation versus Stand-Alone Cage Fusion versus Corpectomy and Plate Fixation

  • Kim, Min-Ki;Kim, Sung-Min;Jeon, Kwang-Mo;Kim, Tae-Sung
    • Journal of Korean Neurosurgical Society
    • /
    • v.51 no.3
    • /
    • pp.135-140
    • /
    • 2012
  • Objective : To evaluate radiographic results of anterior fusion methods in two-level cervical disc disease : tricortical autograft and plate fixation (ACDF-AP), cage and plate fixation (ACDF-CP), stand-alone cage (ACDF-CA), and corpectomy and plate fixation (ACCF). Methods: The numbers of patients were 70 with a minimum 6 month follow-up (ACDF-AP : 12, ACDF-CP : 27, ACDF-CA : 15, and ACCF : 16). Dynamic simple X-ray and computed tomography were evaluated preoperatively, postoperatively, 6 month, and at the final follow-up. The fusion and subsidence rates at the final were determined, and global cervical lordosis (GCL), cervical range of motion, fused segment angle (FSA), and fused segment height (FSH) were analyzed. Results: Nonunion was observed in 4 (25%) patients with ACDF-CA, 1 (8%) patient with ACDF-AP, 1 (4%) patient with ACDF-CP. The number of loss of FSH (%) more than 3 mm were 2 patients (16%) in ACDF-AP, 3 patients (11%) in ACDF-CP, 5 patients (33%) in ACDF-CA, and 3 patients (20%) in ACCF. The GCL was decreased with ACDF-CA and increased with others. The FSA was increased with ACDF-AP, ACDF-CP, and ACCF, but ACDF-CA was decreased. At the final follow-up, the FSH was slightly decreased in ACDF-CP, ACDF-AP, and ACCF, but ACDF-CA was more decreased. Graft related complication were minimal. Screw loosening, plate fracture, cage subsidence and migration were not identified. Conclusion: ACDF-CP demonstrated a higher fusion rate and less minimal FSH loss than the other fusions in two-level cervical disc disease. The ACDF-AP and ACCF methods had a better outcome than the ACDF-CA with respect to GCL, FSA, and FSH.

Revision Anterior Cruciate Ligament Surgery Using Hamstring Autograft (슬괵건을 이용한 전방 십자 인대 재 재건술)

  • In Yong;Bahk Won-Jong;Kwon Oh-Soo;Suh Young-Wan;Im Dong-Sun
    • Journal of the Korean Arthroscopy Society
    • /
    • v.7 no.2
    • /
    • pp.183-188
    • /
    • 2003
  • Purpose : The purpose of this study is to evaluate the results of revision surgery for failed anterior cruciate ligament (ACL) reconstruction using quadruple hamstring tendon autograft. Materials and Methods : From May 2000 to July 2002, six patients received ACL revision surgery using quadruple hamstring autograft for failed ACL reconstruction. Femoral tunnels were made 40 mm in depth and fixed with a cross pin and a bioabsorbable interference screw to fill the bone defect. In tibial tunnels, the grafts were fixed with Intrafix(Mitek, Norwood, MA). In case of tibial tunnel widening, additional screw-washer fixation was done. Follow up was at least 12 months postoperatively. Clinical assessments consisted of Lysholm knee scores, International Knee Documentation Committee(IKDC) evaluation form and manual maximal side to side difference using KT-2000 arthrometer. Results : The average Lysholm knee score improved from 77.2 preoperatively to 87.7 postoperatively. At the final IKDC evaluation, 1 case was graded as normal, 4 nearly normal, 1 abnormal. Mean side to side difference of manual maximum anterior displacement using the KT-2000 arthrometer was 1.8mm. The success rate was $83\%$. Conclusion : ACL revision surgery using quadruple hamstring autograft with double fixation is considered good procedure with successful results.

  • PDF

Treatment of Atlantoaxial Fractures (제1,2경추골절의 치료)

  • Jin, Sung-Chul;Kim, Sang-Jin
    • Journal of Trauma and Injury
    • /
    • v.19 no.2
    • /
    • pp.164-172
    • /
    • 2006
  • Background: The authors conducted a retrospective study to evaluate the mechanism of injury, the surgical techniques, the clinical features, the combined injuries, the treatment results, and the surgical complications in patients with atlantoaxial fracture/subluxations. Methods: The authors reviewed 71 cervical fracture/dislocations during a four-year period from September 2002 to August 2006. Among them, there were twenty one C1,2 fracture/subluxations. There were thirteen men (mean age : 43.5 years) and eight women (mean age : 50 years). Their follow-up period was at least 6 months, and the mean follow-up period was 9.6 months. Gardner-Wells tongs traction was used in all patients immediately on presentation. Surgical treatment was performed, depending on the pathologic conditions. Results: Of all 21 cases, 14 cases were injured in motor vehicle accidents, 5 were falls, and 2 were miscellaneous. There were four C1 fracture (5.6%), fourteen C2 fracture (66.7%), one C1 and 2 combined fracture (4.8%), and one C1-2 subluxation (4.8%). The C1 fractures in our series were classified as two Jefferson's fractures and two C1 lateral mass fracture. The C2 fractures were classified as one odontoid type I fracture, two odontoid type II fractures, five odontoid type III fractures, one hangman's fracture, and four C2 body tear-drop fractures. Atlantoaxial fractures were associated with six (28.6%) head injuries, four (19.0%) other spinal injuries, two (9.5%) chest injuries, and three (14.3%) spinal cord injuries. Surgical treatment was performed in nine cases, which included anterior odontoid screw fixation in two cases, transarticular screw fixation with iliac bone graft in one case, posterior fixation by using C2 pedicle screw and C3 lateral mass screw in three cases, lateral mass screw fixation C1-2 with iliac bone graft in one case, O(occipito)-C1-3-4 screw fixation in one case, posterior C2-3 wiring with allograft in one case, and halo vest in six cases. Conservative management was used in the rest of the patients in our trials. Bone fusion was complete in all cases. There were no operation-related complication, except one pin site infection in the case of halo vest. Conclusion: In this study, the choice of appropriate treatment according to the fracture types resulted in safe and effective management of unique atlantoaxial fracture/subluxations.