• Title/Summary/Keyword: Anterior cervical locking plate

Search Result 5, Processing Time 0.019 seconds

Long-term Effects on the Cervical Spine after Anterior Locking Plate Fixation (경추 전방 잠금식 금속판이 장기적으로 경추에 미치는 영향)

  • Kim, Keun Su
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.4
    • /
    • pp.493-500
    • /
    • 2001
  • Objective : Anterior cervical locking plates are the devices for achieving anterior cervical spinal fusion. This study was conducted to evaluate the locking plate system regarding its long-term advantages and disadvantages in the view of interbody fusion rate, hardware-related failures, vertebral change close to the fusion segment and postoperative complications. Method : Eight-six patients, operated from Jan., 1996 to Jun. 1998, were followed-up for more than two years. All of the cases were fused with iliac bone graft and ORION locking plate(Sofamor Danek USA, Inc., Memphis, TN) fixation. The patients were discharged or transferred to rehabilitation department 2-7 days after operation. A comprehensive evaluation of the interbody fusion state, instrument failure, vertebral change and postoperative complications were made by direct interview and cervical flexion-extension lateral plain films. Results : There were 55 male and 31 female with a mean age of 45 years(18-75 years). The mean follow-up period was 29 months(24-43 months). Various disorders that were operated were 40 cervical discs, 6 cervical stenosis including OPLL, 2 infections, and 38 traumas. Fusion level was single in 59 cases, two levels of each disc space in 15 cases, and two levels after one corpectomy in 12 cases. There was no instrument failure. Pseudoarthrosis was observed in two cases(2%) without radiological instability. The other patients(98%) showed complete cervical fusion with stable instrument. Mild settling of interbody graft with upward migration of screws was found in 12 cases(14%). Anterior bony growth at the upper segment was found in 5 cases(6%). Postoperative foreign body sensation or dysphagia was observed in 12 cases(4%), and disappeared within one month in 7 cases and within six months in 4 cases. One patient complained for more than six months and required reoperation to remove paraesophageal granulation tissue. Conclusion : The results show that Orion cervical locking plate has some disadvantages of upward migration of screws, anterior bony growth at the upper segment, or possibility of esophageal compression even though it has advantages of high interbody fusion rate or low instrument failure. Author believe that anterior cervical locking plate in the future should be thinner, and should have short end from the screw hole, and movable screw with adequate stability.

  • PDF

Functional Outcomes of Subaxial Spine Injuries Managed With 2-Level Anterior Cervical Corpectomy and Fusion: A Prospective Study

  • Jain, Vaibhav;Madan, Ankit;Thakur, Manoj;Thakur, Amit
    • Neurospine
    • /
    • v.15 no.4
    • /
    • pp.368-375
    • /
    • 2018
  • Objective: To evaluate the results of operative management of subaxial spine injuries managed with 2-level anterior cervical corpectomy and fusion with a cervical locking plate and autologous bone-filled titanium mesh cage. Methods: This study included 23 patients with a subaxial spine injury who matched the inclusion criteria, underwent 2-level anterior cervical corpectomy and fusion at our institution between 2013 and 2016, and were followed up for neurological recovery, axial pain, fusion, pseudarthrosis, and implant failure. Results: According to Allen and Ferguson classification, there were 9 cases of distractive extension; 4 of compressive extension; 3 each of compressive flexion, vertical compression, and distractive flexion; and 1 of lateral flexion. Sixteen patients had a score of 6 on the Subaxial Injury Classification system, and the rest had a score of more than 6. The mean follow-up period was 19 months (range, 12-48 months). Neurological recovery was observed in most of the patients (78.21%). All patients experienced relief of axial pain. None of the patients received a blood transfusion. Twenty-one patients (91.3%) showed solid fusion and 2 (8.69%) showed possible pseudarthrosis, with no complications related to the cage or plate. Conclusion: Two-level anterior cervical corpectomy and fusion, along with stabilization with a cervical locking plate and autologous bone graft-filled titanium mesh cage, can be considered a feasible and safe method for treating specific subaxial spine injuries, with the benefits of high primary stability, anatomical reduction, and direct decompression of the spinal cord.

Anterior Cervical interbody Fusion with Cervical Spine Locking Plate (경추 물림 금속판을 이용한 경추 전방추체간 유합술)

  • Park, Joo-Tae;Ahn, Gil-Young;Lee, Young-Tae;Ahn, Myun-Whan
    • Journal of Yeungnam Medical Science
    • /
    • v.14 no.1
    • /
    • pp.209-219
    • /
    • 1997
  • Objectives: Anterior approach to achieve arthrodesis of the cervical spine has become a widely accepted and often-used approach since its earliest reports by Bailey and Badgley, Smith and Robinson and Cloward. However, anterior interbody fusion in the presence of the posterior instability may be complicated by the bone graft dislodgement, kyphotic defomity or nonunion. As an attemp to prevent this undesirable complication, additional methods such as skeletal traction, halo appratus or even posterior fusion has been utilized. Therefore, The cervical spine locking plate(CSLP) with the anterior intervertebral body bone grafting provide immediate cervical stabilization and widely successful in achieving fusion. Material and methods: This study analysed 14 patients who underwent a single anterior procedure and application of CSLP for the treatment of the cervical spinal disorder. Eleven patients were disc herniations and three patients were traumatic lesion. The average age of the patient was 47 years and the mean follow up periods was 20 months ranging from 13 to 27 months. Results: Ambulation was started 2nd day after the operation with the aid of the Philadelpia orthoses. Bone union was observed 13 cases on average 12 weeks after operation. The one case was nonunion with plate breakage without clinical symptom. Conclusion: Anterior fusion with CSLP are thought to be a safe and valuable method for treating cervical spine disorder.

  • PDF

Load Sharing Mechanism Across Graft-Bone Interface in Static Cervical Locking Plate Fixation

  • Han, In-Ho;Kuh, Sung-Uk;Chin, Dong-Kyu;Jin, Byung-Ho;Cho, Yang-Eun;Kim, Keun-Su
    • Journal of Korean Neurosurgical Society
    • /
    • v.45 no.4
    • /
    • pp.213-218
    • /
    • 2009
  • Objective : This study is a retrospective clinical study over more than 4 years of follow up to understand the mechanism of load sharing across the graft-bone interface in the static locking plate (SLP) fixation compared with non-locking plate (NLP). Methods : Orion locking plates and Top non-locking plates were used for SLP fixation in 29 patients and NLP fixation in 24 patients, respectively. Successful interbody fusion was estimated by dynamic X-ray films. The checking parameters were as follows : screw angle (SA) between upper and lower screw, anterior and posterior height of fusion segment between upper and lower endplate (AH & PH), and upper and lower distance from vertebral endplate to the end of plate (UD & LD). Each follow-up value of AH and PH were compared to initial values. Contributions of upper and lower collapse to whole segment collapse were estimated. Results : Successful intervertebral bone fusion rate was 100% in the SLP group and 92% in the NLP group. The follow-up mean value of SA in SLP group was not significantly changed compared with initial value, but follow-up mean value of SA in NLP group decreased more than those in SLP group (p=0.0067). Statistical analysis did not show a significant difference in the change in AH and PH between SLP and NLP groups (p>0.05). Follow-up AH of NLP group showed more collapse than PH of same group (p=0.04). The upper portion of the vertebral body collapsed more than the lower portion in the SLP fixation (p=0.00058). Conclusion : The fused segments with SLP had successful bone fusion without change in initial screw angle, which was not observed in NLP fixation. It suggests that there was enough load sharing across bone-graft interface in SLP fixation.

Mesenchymal Chondrosarcoma of the Cervical Spine - Case Report - (경추부에 발생한 간엽성 연골육종 - 증 례 보 고 -)

  • Kwon, O Hyun;Kim, Jung Deuk;Park, Sang June;Kim, Eui Joong;Yoon, Sung Moon
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.11
    • /
    • pp.1336-1339
    • /
    • 2001
  • Mesenchymal chondrosarcoma is a rare tumor occurring in both bone and soft tissues and exhibits characteristic of a malignant nature. The authors experienced a case of mesenchymal chondrosarcoma occurring in a 23-year-old woman which had invaded the cervical spine. The patient presented with severe both shoulder pain, left upper extremity weakness(Grade IV) and paresthesia at admission. Radiologic studies of the cervial spine showed an aggressive osteolysis of C4 vertebral body, pedicle and lamina with compression of the spinal cord posteriorly on C3, C4, C5 levels. The tumor was totally removed by a combined anterior and posterior approach. The removed vertebral body was replaced with autogenous bone and stabilized by Codman locking plate symtem. The pathological examination showed characteristic of mesenchymal chondrosarcoma.previous symptoms well improved postoperatively. The authors present a case of mesenchymal chondrosarcoma with review of literature.

  • PDF