• Title/Summary/Keyword: Antegrade intramedullary nail

Search Result 8, Processing Time 0.023 seconds

Antegrade Intramedullary Nailing in Traumatic Humeral Shaft Fractures (외상에 의한 상완골 간부골절의 전향적 골수강내 금속정 고정술)

  • Kim, Eugene;Ahn, Hyung Sun;Choi, Young Joon;Kim, Chung Hwan;Hwang, Jae Kwang;Lee, Jong Ha
    • Journal of Trauma and Injury
    • /
    • v.18 no.1
    • /
    • pp.41-46
    • /
    • 2005
  • Background: We evaluated the clinical and the radiological results of treatment for humeral shaft fractures by using an antegrade intramedullary nail. Methods: Thirty-nine (39) cases of humeral shaft fractures treated with antegrade intramedullary nail were evaluated. Bone union was evaluated with simple radiographic findings, and a functional evaluation was done using the American Shoulder and Elbow Surgeons (ASES) score. Results: The average duration until union was 14.1 weeks. On the functional evaluation using the ASES score, 15 cases were excellent, 19 cases good, 3 cases fair, and 2 cases poor. Conclusion: We conclude that antegrade intramedullary nailing has a good clinical and radiological result for treatment of humeral shaft fractures.

Longitudinal Supraspinatus Tear Associated with Antegrade Humeral Intramedullary Nailing: A Case Report and Literature Review with Focus Placed on Nail Entry Point

  • Shon, Min Soo;Bang, Tae Jung;Yoo, Jae Chul
    • Clinics in Shoulder and Elbow
    • /
    • v.18 no.1
    • /
    • pp.47-51
    • /
    • 2015
  • Iatrogenic damage of the rotator cuff followed by postoperative shoulder function loss is a potential complication after antegrade intramedullary nailing (AIN) for a humeral fracture. The authors present a case of arthroscopic rotator cuff repair and subacromial decompression of a non-healed rotator cuff tendon (mainly supraspinatus) and secondary impingement syndrome caused either by the tear or a proud nail after AIN for a mid-shaft humeral fracture. At presentation, the patient complained of right shoulder pain and 'snapping', especially during forward elevation and abduction of the shoulder, of 4 years duration. Right shoulder pain started sometime after pain due to the humeral shaft fracture, operation had subsided, and persisted after nail removal. Arthroscopic findings showed a longitudinal rotator cuff tear at the nail entry point that had not healed and severe fibrous hypertrophy on the acromion underspace, which is a unique finding since most longitudinal splits of tendon fibers are more likely to heal than conventional rotator cuff tears detached from bone. The torn rotator cuff was repaired after debridement and placing side-to-side sutures. At his 34-month follow-up after rotator cuff repair, the patient showed complete recovery and had excellent clinical scores.

Shoulder Function after antegrade intramedullary interlocking nailing for humeral shaft fracture (상완골 간부 골절에 대한 선행성 교합 골수강내 금속정 고정술 후 견관절 기능)

  • Park, Jin-Young;Chun, Ji-Yong;Kim, Myung-Ho
    • Clinics in Shoulder and Elbow
    • /
    • v.6 no.1
    • /
    • pp.27-36
    • /
    • 2003
  • Antegrade interlocking intramedullary nailing (AIIN) for the humeral shaft fracture can induce shoulder pain and decrease of shoulder function postoperatively. The purpose of this study was to estimate the outcome of the shoulder functions after AIIN through the rotator interval between the subscapularis and the supraspinatus to decrease the shoulder pain. Out of consecutive 43 cases that underwent AIIN 42 had been followed for two years or more. Among them we analysized 40 cases of 39 Patients excluding two cases of Pathologic fractures. The average was 47 years. There were 17 men and 23 women. The average follow-up was 34 months. Open nailing was performed in 26 fractures and closed nailing in 14. Bone graft was done in 7 fractures with open nailing. With a single operation, all but two patients achieved osseous union. Average pain score with visual analog scale was one (range; 0∼4) postoperatively By the Neer's score 37 patients received a excellent or satisfactory results while 3 patients' unsatisfactory or failed results. By the functional score of ASES (American Shoulder and Elbow Society) 6 cases received the fair or poor results. Except three cases with persistent nerve palsy and one case of technique failure with protruded nail over humeral head, all patients could achieved satisfactory results with Neer's score and 35 cases (94%) satisfactory results with functional score of ASES. An insertion of antegrade nail to the rotator interval was recommended for better shoulder functions and less pain postoperatively.

Arthrodesis of the Knee Using a Retrograde Femoral Intramedullary Nail: Technical Report (역행성 대퇴부 골수강 내 금속정을 이용한 슬관절 고정술: 술기 보고)

  • Wang, Lih;Kim, Sun Hyo
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.2
    • /
    • pp.183-189
    • /
    • 2021
  • Arthrodesis is one of the last options available to obtain a stable, painless knee in patients who are unable to undergo reconstructive surgery due to a damaged knee joint. A variety of techniques have been used, including external fixation, internal fixation by compression plates, intramedullary fixation through the knee with a modular nail, and antegrade nailing through the piriformis fossa. Another option is the use of a short nail such as the Neff nail, the Wichita nail, or the Huckstep nail, but there are no commercial short nails available for use in Korea. This technical report describes a technique for knee arthrodesis using a retrograde femoral intramedullary nail.

Clinical and Radiographic Outcome of Shoulder Function after Unreamed Antegrade Intramedullary Nailing for Humerus Fracture: Ultrasonographic Evaluation for Rotator Cuff Integrity (비확공성 전향적 상완골 금속정 고정술후 견관절 기능에 대한 임상적 및 방사선학적 평가: 초음파를 이용한 회전근 개 추시관찰)

  • Baek, Seung-Hoon;Choi, Chang-Hyuk
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.6 no.1
    • /
    • pp.1-9
    • /
    • 2013
  • Purpose: The purpose is to perform objective evaluation for rotator cuff using ultrasonography and validate factors influencing cuff integrity as well as efficacy of follow-up ultrasonography after unreamed antegrade intramedullary nailing for humerus fracture. Materials and Methods: Seventeen patients with an average age of $55.7{\pm}18.6$ years underwent antegrade intramedullary nailing for humerus fracture and follow-up ultrasonography of shoulder joint. Mean follow-up period was $43.5{\pm}32.2$ months. Intraoperative evaluation for preoperative cuff tear was performed, of which four cuffs were repaired by single row repair technique. Clinical evaluation included visual analogue scale (VAS), range of motion, Korean Shoulder Scoring System (KSS) and American Shoulder and Elbow Society (ASES) score. Ultrasonographic evaluation was performed on cuff integrity and protrusion of proximal nail tip as well. Radiographic evaluation included time to union, protrusion of proximal nail tip and migration of proximal interlocking screw which could affect shoulder joint function. Results: Mean VAS at last follow-up was $1.65{\pm}1.84$ points. Range of motion showed forward flexion of $137.0{\pm}33.5^{\circ}$, external rotation of $43.5{\pm}12.7^{\circ}$ and internal rotation of $16.4{\pm}2.0^{\circ}$ while KSS score and ASES score were $79.6{\pm}20.7$ and $83.7{\pm}17.0$ points, respectively. Bone union was demonstrated in all cases and average time to union was $3.4{\pm}1.3$ months. Migration of proximal interlocking screw was shown in 6 cases (35%). On ultrasonographic evaluation, there were normal in 8 (47%), weaving in 4 (24%), partial tear in 5 cases (29%), but no complete tear. Protrusion of proximal nail tip was demonstrated in 8 cases (47%) on plain radiographs whereas in 11 cases (65%) on ultrasonography and was associated with increasing age (p=0.038). Ultrasonographic weaving and partial tear was associated with protrusion of proximal nail tip (p=006), but not with repair of preoperative tear (p>0.05). Conclusion: Because weaving and partial tear on ultrasonography originated from protrusion of proximal nail tip, careful insertion of nail and meticulous repair of cuff during operation lead to stable fixation with satisfactory recovery of shoulder function follow-up ultrasonography can be a useful tool for evaluating protrusion of nail tip and rotator cuff tear, of which diagnosis is difficult on plain X-ray after antegrade intramedullary nailing for humerus fracture.

  • PDF

Surgical Treatment of Ipsilateral Multi-Level Femoral Fracture Treated Using Antegrade Intramedullary Nail

  • Kim, Beom-Soo;Cho, Jae-Woo;Yeo, Do-Hyun;Oh, Jong-Keon
    • Journal of Trauma and Injury
    • /
    • v.31 no.2
    • /
    • pp.96-102
    • /
    • 2018
  • Ipsilateral fractures of proximal femur with shaft and condylar region are very rare. Current concept of management is based on fixation of each fracture as independent entity using separate fixation modalities for proximal and distal parts of femur. However, we considered that antegrade femoral nailing with cephalomedullary screw fixation is a good option for ipsilateral multi-level femoral fractures. Here, we present an experience of satisfactory treatment for ipsilateral femoral neck fracture, subtrochanteric fracture, comminuted shaft fracture with supracondylar fracture following road traffic accident.

The Effect of Fibular Fixation on Ankle Function in Intramedullary Nailing for Distal Tibiofibular Fractures (원위 경비골 골절에 대한 골수강내 금속정술에서 비골 고정이 족근 관절 기능에 미치는 영향)

  • Suh, Byung-Ho;Lee, Soo-Won;Kong, Gyu-Min;Kim, Dong-Jun;Oh, Hyun-Keun
    • Journal of Korean Foot and Ankle Society
    • /
    • v.13 no.2
    • /
    • pp.169-174
    • /
    • 2009
  • Purpose: To evaluate the clinical results between interlocking intramedullary nail with fibular fixation and nail only for treating distal tibiofibular diaphyseal fractures. Materials and Methods: From March 2003 to September 2006, 19 distal tibiofibular fractures were antegrade nailed after anatomical reduction and fixation of fibular fractures, and another 37 fractures fixed with nails only. Average age of patients was 48.6 years. These two groups were compared by VAS (visual analogue scale) & ankle ROM according to degree of comminution and fracture configuration. The statistical analysis was evaluated by t-test. Results: There was no statistical difference between fibular fixation group and non-fixation group in VAS score according to fracture comminution and configuration (p>0.05). However, compared according to fracture configuration, mean ankle eversion of fibular fixation group in oblique fractures was 18.3 degrees, and that of non-fixation group was 12.5 degrees (p<0.05). In addition, mean ankle plantar flexion, dorsiflexion, inversion and total ankle ROM of fibular fixation group in spiral fractures was 40.0, 20.0, 30.0 and 108.3 degrees of each and that of non-fixation group was 38.3, 18.5, 27.0 and 101.7 degrees (p<0.05). Conclusions: In oblique and spiral fractures of distal tibiofibular diaphysis, interlocking intramedullary nail with fibular fixation had the advantage in postoperative ankle ROM. So, it can be a worthy method for the treatment of distal tibiofibular diaphyseal fractures.

  • PDF

Analysis of Anatomical Conformity of Straight Antegrade Humeral Intramedullary Nail in Korean (한국인에서의 직선형 전향적 상완골 골수 내 금속정의 해부학적 적합성 분석)

  • Choi, Sung;Jee, Seungmin;Hwang, Seongmun;Shin, Dongju
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.6
    • /
    • pp.498-503
    • /
    • 2021
  • Purpose: The aim of this study were to find ideal entry point of straight antegrade humeral intramedullary nail (SAHN) for the treatment of proximal humerus fracture in Korean and to analyze anatomical conformity using computed tomography. Materials and Methods: From May 2014 to October 2016, the study was conducted retrospectively on 74 Korean patients who had taken computed tomography on both normal and affected shoulder joint as result of shoulder injury. The mean age of the patients was 64.5 years (range, 22-95 years). Radiologic evaluation was done using multiplanar reconstruction technique of the computer tomography on normal proximal humerus. We located ideal entry point of SAHN as the point where humerus intramedullary center axis and humeral head meet. Distance between the entry point and local anatomical landmark was measured. We defined the critical distance as the distance between entry point and the most medial point of the supraspinatus attachment site. For adequate fixation and avoidance of injury to rotator cuff, critical distance should be over 8 mm according to Euler, and we defined the critical type when it is less than 8 mm. Critical distance, sex, age, height, body weight, body mass index was evaluated for the statistical significance. Results: The ideal entry point was as follows: the mean anteroposterior distance, the sagittal distance to the lateral margin of bicipital groove, was 11.5 mm and the mean mediolateral distance, the coronal distance to the lateral margin of grater tuberosity, was 20.5 mm. The mean critical distance, distance from the entry point to the just medial to insertion of the supraspinatus tendon, was 8.0 mm. Critical type with critical distance less than 8 mm was found in 41 in 74 patients (55.4%). Conclusion: The ideal entry point of SAHN in Korean was located on 11.5 mm posteriorly from the lateral margin of bicipital groove and 20.5 mm medially from lateral margin of greater tuberosity. More than half of the cases were critical type. Since critical type can possibly cause rotate cuff injury during nail insertion on entry point, surgeon should consider anatomical variance before choosing surgical option.