• Title/Summary/Keyword: Antecedent dry

Search Result 39, Processing Time 0.025 seconds

Loading Characteristics of Non-Point Source Pollutants by Rainfall - Case Study with Sweet Potato Plot - (강우시 비점오염원의 오염부하 특성 - 고구마 재배지를 대상으로 -)

  • Kang, Mee-A;Jo, Soo-Hyun;Choi, Byoung-Woo;Yoon, Young-Sam;Lee, Jae-Kwan
    • The Journal of Engineering Geology
    • /
    • v.19 no.3
    • /
    • pp.365-371
    • /
    • 2009
  • This paper address the characteristics of loading pollutants caused by the unit agricultural area to establish an efficient management method in NPS (non-point source). The relationship between rainfall and runoff shows good coefficient with 0.92, when the event which shows relatively long antecedent dry days is excepted. The impact of runoff volume on the runoff coefficient can be described by the rainfall intensity strongly. The pollutant EMCs (event mean concentrations) in runoff increased by the increase of antecedent dry days due to dry soil conditions. As the similar pattern of pollutant's loads such as TSS, BOD, COD, TN and TP, it is cleared that other pollutants can be removed when TSS is removed. Therefore the system using only runoff coefficients is not sufficient for the prediction of pollutant loads. It is necessary to consider soil conditions such as rainfall, antecedent dry day, antecedent rainfall etc. for the prediction system.

Rainfall-Runoff Characteristics in a Jeju Stream considering Antecedent Precipitation (선행강우를 고려한 제주하천 유출특성 분석)

  • Yang, Sung-Kee;Kim, Dong-Su;Jung, Woo-Yul
    • Journal of Environmental Science International
    • /
    • v.23 no.4
    • /
    • pp.553-560
    • /
    • 2014
  • The rainfall-runoff characteristics in Jeju Island significantly differ from those in inland, due to highly permeable geologic features driven by volcanic island. Streams are usually sustained in the dry conditions and thereby the rainfall-runoff characteristics changes in terms of initiating stream discharge and its types, depending highly on the antecedent precipitation. Among various the rainfall-runoff characteristics, lag time mainly used for flood warning system in river and direct runoff ratio for determining water budget to estimate groundwater recharge quantity are practically crucial. They are expected to vary accordingly with the given antecedent precipitation. This study assessed the lag time in the measured hydrograph and direct runoff ratio, which are especially in the upstream watershed having the outlet as $2^{nd}$ Dongsan bridge of Han stream, Jeju, based upon several typhoon events such as Khanun, Bolaven, Tembin, Sanba as well as a specific heavy rainfall event in August 23, 2012. As results, considering that the lag time changed a bit over the rainfall events, the averaged lag time without antecedent precipitation was around 1.5 hour, but it became increased with antecedent precipitation. Though the direct run-off ratio showed similar percentages (i.e., 23%)without antecedent precipitation, it was substantially increased up to around 45% when antecedent precipitation existed. In addition, the direct run-off ration without antecedent precipitation was also very high (43.8%), especially when there was extremely heavy rainfall event in the more than five hundreds return period such as typhoon Sanba.

Runoff Characteristics of Non-point Source According to Rainfall in Nam Watershed (남천에서의 강우시 비점오염물질의 유출특성)

  • Jang, Seong-Ho;Park, Jin-Sick
    • Journal of Environmental Health Sciences
    • /
    • v.31 no.1
    • /
    • pp.1-6
    • /
    • 2005
  • This study was conducted to identify the runoff characteristics of non-point source according to rainfall in Nam watershed. Land-uses of the Nam watershed were surveyed paddy field 4.5%, crop field 6.8%, mountainous 78.7%, urban 2.4%, and etc. 7.7%. Mean runoff coefficients in each area were observed Ⅰ area 0.08, Ⅱ area 0.08, and Ⅲ area 0.05. In the relationship between the rainfall and peak-flow, correlation coefficients(r) were investigated Ⅰ area -0.8609, Ⅱ area 0.6035, and Ⅲ area -0.4913. In the relationship between the antecedent dry period and first flow runoff, correlation coefficients(r) were investigated Ⅰ area -0.9093, Ⅱ area -0.1039, and Ⅲ area -0.7317. The discharge of pollutant concentrations relates to the flow rate of storm-water. In the relationship between the rainfall and watershed loading, exponent values of BOD, COD, SS, and T-N were estimated to 1.2751, 1.2003, 1.3744, and 1.1262, respectively.

The Flow rate estimation of CSOs using EC Data (전기전도도를 이용한 CSO의 유량 추정)

  • Choi, Weon-Suk;Song, Chang-Soo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.5
    • /
    • pp.751-757
    • /
    • 2011
  • The monitoring technique based on electrical conductivity (EC) can provide researchers with some advantages in maintenance management and is cost-effective as compared with existing CSOs monitoring. In this study, the flow rate estimation using EC data was executed in two sites where storm overflow chamber had installed. In the result of A-site, R2 of second order multinomial between dilution ratio of EC and observed flow rate was showed the range of 0.68 ~ 0.77. And $R^{2}$ of B-site was 0.62 ~ 0.81. On the other hand, cumulative frequency of A-site was 43.4 ~ 52.2% in the relative error level of under 20%. And B-site was 10.1 ~ 46.5%. The flow rate estimation formula was improved through consideration of some parameters including antecedent dry days and rainfall duration. And difference between estimated flow rate and observed flow rate in total rainfall event was very small.

Loading Rates and Characteristics of Litter from Highway Stormwater Runoff (강우로 인해 고속도로로부터 유출되는 폐기물의 성상, 부하량 및 유출 특성)

  • Kim, Lee-Hyung;Kang, Joohyon
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.5
    • /
    • pp.415-421
    • /
    • 2004
  • Litter wastes on highway runoff are gradually being considered one of the major pollutants of concern in protecting the integrity of receiving waters for beneficial use. The California State Water Resources Control Board has identified in their 303(d) list at least 36 water bodies where trash or litter is considered a pollutant of concern. The first TMDL adopted by the Region 4 (Los Angeles area) of the California State Water Quality Control Board was for trash in the Los Angeles River. The first flush characteristic study was developed to obtain first flush water quality and litter data from representative stormwater runoff from standard highway drainage outfalls in the Los Angeles area. Total captured gross pollutants in stormwater runoff were monitored at six Southern California highway sites over two years. The gross pollutants were 90% vegetation and 10% litter. Approximately 50% of the litter was composed of biodegradable materials. The event mean concentrations show an increasing trend with antecedent dry days and a decreasing trend with total runoff volume or total rainfall. Event mean concentrations were ranged 0.0021 to 0.259g/L for wet gross pollutants and 0.0001 to 0.027g/L for wet litters. The first flush phenomenon was evaluated and the impacts of various parameters such as rainfall intensity, drainage area, peak flow rate, and antecedent dry period on litter volume and loading rates were evaluated. First flush phenomenon was generally observed for litter concentrations, but was not apparent with litter mass loading rates. Litter volume and loading rates appear to be directly related to peak storm intensity, antecedent dry days and total flow volume.

A Study on the Runoff Characteristics of Non-point Source in Urban Watershed - Case Study on the Dalseo and Daemyung Watershed (도시지역 비점오염물질의 유출특성에 관한 연구 - 달서천 및 대명천을 중심으로)

  • Jang Seong-Ho;Park Jin-Sick
    • Journal of Environmental Science International
    • /
    • v.14 no.12
    • /
    • pp.1171-1176
    • /
    • 2005
  • This study was conducted to identify the runoff characteristics of non-point source according to rainfall in Dalseo and Daemyung watershed. Land-uses of the Dalseo and Daemyung watershed were surveyed to urban $72.1\%$ and mountainous $6.7\%$, and urban $49.3\%$ and mountainous $20.5\%$, respectively Mean runoff coefficients in each area were estimated to Dalseo watershed 0.49 and Daemyung watershed 0.16. In the relationship between the rainfall and peak-flow correlation coefficients(r) were determined to Dalseo watershed 0.9060 and Daemyung watershed 0.5620. In the relationship between the antecedent dry period and flrst flow runoff correlation coefficients(r) were determined to Dalseo watershed 0.7217 and Daemyung watershed 0.2464. In the relationship between the rainfall and watershed loading, exponent values of SS in Dalseo and Daemyung watershed were estimated to 0.54 and 0.496, respectively.

Stormwater Runoff Characteristics of Non-point Source Pollutants according to Landuse of Urban Area (도시지역 토지이용에 따른 비점원 오염물질 유출특성)

  • Jeong, Dong-Hwan;Shin, Dongseok;Rhew, Doughee;Jung, Dongil
    • Journal of Environmental Impact Assessment
    • /
    • v.16 no.6
    • /
    • pp.525-532
    • /
    • 2007
  • In order to establish and implement the total maximum daily load (TMDL) management plan in Korea, it is necessary to set the source units and calculate discharge loads for non-point source pollutants such as BOD, COD, SS, TN and TP. This study analysed the corelation between stormwater runoff characteristics and event mean concentrations (EMCs) of non-point source pollutants. As the result of the corelation analysis, we knew that all the antecedent dry days (ADD) and the rainfall correlated lowly with non-point source pollutants in the urban areas such as resident area, industrial area, business area, road area and parking area. Therefore, it is necessary to get all samples from stormwater starting point to stormwater ending point and standardize the sampling method of stormwater in order to obtain more accurate EMCs for landuse.

A Study of Non-point Source Reduction Efficiency by Constructed Wetland installed in Flood Pumping Station (빗물펌프장에 설치된 인공습지의 비점오염원 저감효율 연구)

  • Chun, Suk-Young;Kim, Ji-Tae;Lee, Il-Kook;Chang, Soon-Woong
    • Journal of Environmental Impact Assessment
    • /
    • v.23 no.1
    • /
    • pp.67-74
    • /
    • 2014
  • The aim of this study was evaluated the effects of total rainfall, rainfall intensity and antecedent dry days and identify the correlation analysis with the EMC removal efficiency, in order to provide an understanding of the operation and maintenance factors of constructed wetland in flood pumping station. This study was conducted total of 20 monitoring in a catchment(326.2 ha) of constructed wetland in Ga-un flood pumping station located at the downstream of the Wang-suk stream. The determined EMC removal efficiencies were $36.04{\pm}9.45%$ for BOD, $38.50{\pm}13.50%$ for $COD_{Mn}$, $34.34{\pm}13.05%$ for TN and $34.22{\pm}14.27%$ for TP, respectively. These results showed that the pollutants concentration and EMC were reduced while passing through the constructed wetland. In the correlation analysis, the highly correlations with EMC removal efficiency of BOD and $COD_{Mn}$ were observed for total rainfall and rainfall intensity (P<0.05). However, the correlations were not found with TN and TP for rainfall variables.

Instability Analysis of Unsaturated Soil Slope Considering Wet Condition (습윤상태를 고려한 불포화 토사사면의 불안정성 해석)

  • Kim, Yong Min;Kim, Jaehong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.4
    • /
    • pp.1489-1498
    • /
    • 2013
  • The monolithically coupled finite element analysis for a deformable unsaturated soil slope is performed to investigate the effect of antecedent rainfall which is assumed by initial conditions varying degree of saturation (36, 51, 77%) in finite element analysis. The distributions of matric suction and deformation on slope surface obtained from numerical simulation show the instability of antecedent rainfall-induced unsaturated soil slope. Moreover, the numerical analysis using Drucker-Prager model can be checked if a soil slope has reached failure (trial failure criterion $f^{tr}$ >0, plastic behavior) or not (trial failure criterion $f^{tr}$ < 0, elastic behavior). It is found that displacement of slope surface layer increases and the matric suction on soil slope decreases with an increase of initial degree of saturation by antecedent rainfall. Especially, the matric suction of the soil slope in dry condition (S=36%) rapidly decreases rather than that in wet condition (S=51%) at the same rainfall duration. The results of the trial failure criterion ($f^{tr}$ > 0) show slope instability in the toe region and surface of the slopes.

Analysis of pollutant build-up model applied to various urban landuse

  • Choi, Jiyeon;Na, Eunhye;Ryu, Jichul;Kim, Jinsun;Kim, Hongtae;Shin, Dongsuk
    • Membrane and Water Treatment
    • /
    • v.10 no.1
    • /
    • pp.13-17
    • /
    • 2019
  • This study was conducted to analyse the application of pollutant build-up model on various urban landuses and to characterize pollutant build-up on urban areas as a source of stormwater runoff pollution. The monitored data from impervious surfaces in urban areas such as commercial (8 sites), industrial (10 sites), road (8 sites), residential (10 sites), recreational (5 sites) from 2008 to 2016 were used for the analysis of pollutant build-up model. Based on the results, the average runoff coefficients vary from 0.35 to 0.61. In all landuses except recreational landuse, the runoff coefficient is 0.5 or more, which is the highest in the commercial area. Commercial landuse where pollutants occur at the highest EMC in all landuse, and it is considered that NPS management is necessary compared with other landuses. The maximum build-up load for organic matter (BOD) was highest in the commercial area ($4.59g/m^2$), and for particular matter (TSS) in the road area ($5.90g/m^2$) while for nutrient (TN and TP) in the residential area ($0.40g/m^2$, $0.14g/m^2$). The rate constants ranged from 0.1 to 1.3 1/day depending on landuse and pollutant parameters, which means that pollutant accumulation occurs between 1 and 10 days during dry day. It is clear that these build-up curves can generally be classified based on landuse. Antecedent dry day (ADD) is a suitable and reasonable variable for developing pollutant build-up functions. The pollutant build-up curves for different landuse shows that these build-up curves can be generally categorized based on landuse.