• Title/Summary/Keyword: Anoxic

Search Result 443, Processing Time 0.023 seconds

Effect of Zinc on the Suspended Growth Biological Wastewater Treatment (부유 성장식 생물학적 폐수처리에 미치는 아연의 영향)

  • Seo, Jeong-Beom;Hwang, Chang-Min
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.4
    • /
    • pp.228-233
    • /
    • 2015
  • This study was performed to examine the effect of zinc on the biodegradability, nitrification, denitrification and oxygen uptake rate (OUR) using batch reactor and continuous flow stirred tank reactor (CSTR) of anaerobic/anoxic/oxic ($A^2/O$). The results of this study can be summarized as follows. In the case of the effect of zinc on organic treatment, zinc had no effect up to 12 mg/L with batch reactor but biodegradability was lowered when it was above 3.0 mg/L with CSTR. Concerning the case on nitrification and removal of nitrogen, nitrification rate was lowered when zinc was above 6.0 mg/L with batch reactor and removal rate of nitrogen was lowered when zinc was above 3.0 mg/L with CSTR. Removal rate of phosphorus was lowered when it was above 6.0 mg/L zinc with batch reactor and above 3.0 mg/L zinc with CSTR. In the case of OUR, it decreased as microbial activity was affected when zinc concentration was above 3.0 mg/L in CSTR.

Characteristics of sewage Treatment by using Indirectly Aerated Submerged Biofilter(INSUB) (간접폭기형 침적생물여과장치(INSUB)를 이용한 오수처리 특성)

  • Huh, Mock;Kang, Jin-Yuong;Kim, Gwang-Jin
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.11 no.2
    • /
    • pp.125-131
    • /
    • 2003
  • This study was carried out to develop INSUB(Indirected Aerated Submerged Biofilter) which can remove organics, nitrogen and phosphorus with an advanced treatment system. The results were as followed in laboratory model experiment. As for treatment of sewage, when economical efficiency was considered in practice, the highest removal efficiency was at 18hr of HRT, 1.017m/hr of superficial velocity and 40% of media packing ratio. Each removal efficiency for $COD_{cr}$, $COD_{Mn}$, $BOD_5$, T-N, and T-P was 90.6, 85.3, 95.0, 52.3 and 56.8%. To remove the nitrogen and phosphorus With high efficiency, first of all, denitrification have to be completed, then uptake of phosphorus have to completed. Therefor, mixture of anoxic and aerobic reactor was necessary for the high removal efficiency of nitrogen and phosphorus in INSUB.

  • PDF

Development of Biological Filtration Process for Effective Nitrogen Removal in Tertiary Treatment of Sewage (생물막 여과반응기를 이용한 고도질소 제거법의 개발)

  • Jeong, Jin-Woo;Kim, Sung-Won;Tsuno, Hiroshi
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.2
    • /
    • pp.222-229
    • /
    • 2006
  • The treatment performance and operational parameters of a tertiary wastewater treatment process a biological filtration system were investigated. The biological filtration system consisted of a nitrification filter (Fiter 1) and a polishing filter with anoxic and aerobic parts (Filter 2). SS, T-C-BOD, and T-N in effluent were kept stable at less than 3, 5 mg/L, and 5 mgN/L, respectively, under a HRT in Filter (filter-bed) of 0.37~2.3 h. T-N at the outlet of Filter 2 were about 1~5 mgN/L under the condition of LV of 50~202 m/d. In Filter 2, denitrification was accomplished under LV of 50~168 m/d in a 1 m filter-bed. However, the denitrification capacity reached the maximum when the linear velocity was increased to 202 m/d. Relationship between increase in microorganism and headloss was clearer in Filter 2. As a result, the denitrification rate increased from 1.0~2.3 kgN/($m^3-filter-bed{\cdot}d$) as the headloss increased. The COD removal rate was 6.0~9.6 kgCOD/($m^3-filter-bed{\cdot}d$) when operated with Filters 1 and 2. These results mean that captured bacteria contributed a part of COD consumption and denitrification. The maximum nitrification and denitrification rate was 0.5 and 4 kgN/($m^3-filter-bed{\cdot}d$) in Filter 1 and 2.The ratio of backwashing water to the treated water was about 5~10 %. In Filter 1, wasted sludge in backwashing was only 0.7~5.3 gSS/($m^3$-treated water). In Filter 2, added methanol was converted into sludge and its value was 8.0~24 gSS/($m^3$-treated water). These results proved that this process is both convenient to install as tertiary treatment and cost effective to build and operate.

Effects of Nitrifying Bacterial Communities with Different HRTs and Backwashing Periods in Modified BAF Process (Modified BAF 공정에서 HRT 및 역세주기가 질산화 미생물의 군집에 미치는 영향)

  • Jung, Chul-Soo;Park, Jeung-Jin;Ju, Dong-Jin;Kwon, Soo-Youn;Choi, Won-Seok;Byun, Im-Gyu;Park, Tae-Joo
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.6
    • /
    • pp.920-926
    • /
    • 2007
  • The upflow Biobead$^{(R)}$ process, one of biological aerated filters (BAF), which was used commercially, invented for removal of organic materials and nitrification. This process was modified to enhance the ability of denitrification through the induction of pre-anoxic tank. In this research, we investigated the effects of hydraulic retention time (HRT) and backwashing period in aerobic tank. The characteristics of nitrifying bacteria, which are composed of ammonia-oxidizing bacteria (AOB) and nitrite-oxidizing bacteria (NOB), also investigated using fluorescence in situ hybridization (FISH). Even though the HRT was shortened, the efficiency of nitrification was not decreased when the organic loading rate and ammonium-nitrogen loading rate were $2.10kg/m^3/day$ and $0.25kg/m^3/day$, respectively. And then the distribution ratios of AOB and NOB showed the similar patterns. However, when the backwashing period was lengthened from 12 hours to 24 hours in aerobic 1 tank, the nitrification efficiency was decreased to 63.9% from 89.2%. The results of FISH explained that this decrease of nitrification efficiency was caused by the decrease of distribution ratio of AOB in aerobic 1 tank. The nitrification efficiencies of aerobic 1 and aerobic 2 tank were increased when the backwashing period was lengthened because of relative high distribution ratios of nitrifying bacteria.

Spatial Distribution and Improvement of Water Quality in the Youngrang Lake (영랑호 수질의 공간적 분포 및 개선방안)

  • Huh, In-Ryang;Yi, Geon-Ho;Jeong, Won-Gu;Kwon, Jae-Hyouk
    • Journal of Korean Society on Water Environment
    • /
    • v.33 no.3
    • /
    • pp.341-347
    • /
    • 2017
  • From 2014 to 2016 water quality survey results according to the location and depth of Youngrang Lake are as follows: Distribution of dissolved oxygen in the water depth was investigated by the middle section and the downstream 1st, 3rd, 5th, when investigating bottem 1m interval anoxic layer. In organic matter and nutrient concentration distribution COD upstream 2.8 mg/L, middle section 4.2 mg/L downstream 4.1 mg/L, more than two times higher in bottem layer and TP concentrations showed a similar trend with COD, upstream of 0.047 mg/L, middle section was 0.051 mg/L, downstream of 0.059 mg/L. There was a difference in salinity every survey period the average salinity is lowest with 28.5‰ when the second survey. And the highest with 32.1‰ in the fourth investigation. Korean trophic state index($TSI_{KO}$) were showed eutrophic conditions in the middle section and downstream else showed mesotrophic state in the entire period. In order to evaluate the cause of water pollution Youngrang lake, regression analysis of the relationship between salinity and DO, COD, TN, TP, Chl-a results, $R^2$ is from 0.63 to 0.95 Youngrang lake water quality was found to have a close relationship with salinity due to inflow of seawater. As a result, in order to improve the quality of Youngrang lake efficient incorporation of the amount of water through the seawater influent as it is considered the key.

Removal of nitrogen and sulfur odorous compounds and their precursors using an electrolytic oxidation process (산화전리수를 이용한 질소와 황 계열 악취 및 악취전구물질의 제거)

  • Shin, Seung-Kyu;An, Hea-Yung;Kim, Han-Seung;Song, Ji-Hyeon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.2
    • /
    • pp.223-230
    • /
    • 2011
  • An electrolytic oxidation process was applied to remove odorous compounds from non-point odor sources including wastewater pipelines and manholes. In this study, a distance between the anode and the cathode of the electrolytic process was varied as a system operating parameters, and its effects on odor removal efficiencies and reaction characteristics were investigated. Odor precursors such as sediment organic matters and reduced sulfur/nitrogen compounds were effectively oxidized in the electrolytic process, and a change in oxidation-reduction potential (ORP) indicated that an stringent anaerobic condition shifted to a mild anoxic condition rapidly. At an electrode distance of 1 cm and an applied voltage of 30 V, a system current was maintained at 1 A, and the current density was 23.1 $mA/cm^{2}$. Under the condition, the removal efficiency of hydrogen sulfide in gas phase was found to be 100%, and 93% of ammonium ion was removed from the liquid phase during the 120 minute operating period. Moreover, the sulfate ion (${SO_4}^{2-}$) concentration increased about three times from its initial value due to the active oxidation. As the specific power consumption (i.e., the energy input normalized by the effective volume) increased, the oxidation progressed rapidly, however, the oxidation rate was varied depending on target compounds. Consequently, a threshold power consumption for each odorous compound needs to be experimentally determined for an effective application of the electrolytic oxidation.

Low Temperature Pyrolysis for the Recovery of Value-added Resources from Waste Wire (II) (폐전선으로부터 유가자원 회수를 위한 저온열분해(II))

  • Han, Seong-Kuk;Kim, Jae-Yong
    • Applied Chemistry for Engineering
    • /
    • v.20 no.5
    • /
    • pp.553-556
    • /
    • 2009
  • This research aims at the recovery of valuable resource and more efficient waste treatment through solving the problem of pyrolysis technique. At first, in order to raise the economical efficiency, the low temperature pyrolysis experiment was carried out at the temperature of $450^{\circ}C$, which is lower than the common pyrolysis temperature area ($500{\sim}1000^{\circ}C$). We could lower the reaction temperature and reduce the reaction time by using catalyst. Also we used indirect heat for the purpose of maintaining favorable anoxic condition. As a result, we could raise the recovery rate of the valuable copper and synthetic fuel oil. Furthermore, the by-products and flue gas could be treated more effectively as well. The flue gas passed through two stage neutralization tank, so that dioxin hardly occurs and other environment items are controlled fairly well to the environmental standard. Throughout this study, we produced the low temperature pyrolysis equipment (GTPK-001) as mentioned above, and we found out that the technique can be commercialized economically as well as environmentally friendly.

Improvement of Single Anaerobic Reactor for Effective Nitrogen Removal (효율적 질소제거를 위한 단일 혐기성반응조의 개선)

  • 한동준;류재근;임연택;임재명
    • Journal of environmental and Sanitary engineering
    • /
    • v.12 no.3
    • /
    • pp.9-17
    • /
    • 1997
  • This research aims to remove nitrogen in the piggery wastewater by combined process with upflow anaerobic sludge blanket (UASB) and biofilm process. For the effective denitrification. anaerobic and anoxic reactors were connected to a reactor. The effluent of aerobix reactor was recycled equally with influent in the upper filter of anaerobic reactor for denitrification and outlet of UBF reactor was connected to the settling tank with $1.5{\;}{\ell}$ capacity and the settling sludge was repeatedly recycled to UASB zone. The organic loading rate of total reactor was operated from 0.4 to $3.1kgCOD/m^{3}/d$ and it was observed that the removal rate of TCOD was 80 to 95 percentage. Ammonia nitrogen was removed over 90 percentage in the less volumetric loading rate than $0.1{\;}kgN/m^{3}/d$. But because of non-limitation of organic materials, it was reduced to 70 percentage in the more volumetric loading rate than $0.6{\;}kgN/m^{3}/d$. But denitrification rate was observed 100 percentage in the all of loading rate. This is caused by the maintenance of optimum temperature, sufficient carbon source, and competition of electron acceptors. The results of COD mass balance at the $1.21{\;}kgCOD/m^{3}/d$ was observed with the 71.7% percentage of influent COD. It was revealed that the most part of organic materials was removed in the aerobic and the anaerobic reactor because 38.4 percentage was conversed into $CH_{4}$ gas and 11 percentage was removed in the aerobic reactor with cell synthesis and metabolism. Besides, 5.7% organics was used to denitrification reaction and 3.7% organics related to sulfate reduction.

  • PDF

Removal of Organic and Nutrients in Fish Market Wastewater using Sequencing Batch Reactor (SBR) (SBR공정을 이용한 수산물 위판장 폐수에서 유기물 및 질소 제거)

  • Kim, Sung-Ju;Lee, Dae-Hee;Park, Hung-Suck
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.1
    • /
    • pp.46-51
    • /
    • 2007
  • This research work aims at treating saline wastewater generated from a fish market using four Sequencing Batch Reactors (SBR) operated under different conditions. The effect of C/N ratio (3, 6) and salt concentration (0.5~2%) on organic and nitrogen removal was studied. The synthetic wastewater prepared with glucose ($C_6H_{12}O_6$) as the primary carbon source along with ammonium chloride ($NH_4Cl$) was used in the three reactors. The fill, anoxic, aeration, settle and draw conditions were 2 hr, 4 hr, 4 hr and 2 hr respectively. The fourth reactor was operated at different conditions to investigate the practical feasibility of SBR application to handle fish market wastewater generated in Ulsan city that had fluctuating loading characteristics. Though the unacclimated sludge was initially affected by the salt concentration, the acclimated sludge removed 95% of the organics irrespective of the NaCl concentration and C/N ratio. However, the removal of nitrogen was affected more by C/N ratio than the salt concentration. While handling fish market wastewater, though the organic and nitrogen loading rate were varying between $0.009{\sim}0.259gCOD_{OH}/gVSS/day$ and 0.005~0.034 gN/gVSS/day, the effluent concentrations were far less than the effluent standard of $120mgCOD_{OH}/L$ and 60 mgN/L respectively, except when loading rates were fluctuating and 4 times higher than the average.

Complete Repair of Tetralogy of Fallot in Neonate or Infancy (신생아및 영아기 활로씨 사징증의 완전 교정술)

  • 이정렬
    • Journal of Chest Surgery
    • /
    • v.25 no.1
    • /
    • pp.32-41
    • /
    • 1992
  • From August 1982 to December 1991, 58 consecutive infants with tetralogy of Fallot underwent primary repair. Age ranged from 22 days to twelve months [n=58, 8.7$\pm$2.7 months] and body weight from 3.1 to 13 kilograms [n=58, 7.8$\pm$1.7 kilograms]. Qne infant had absence of the pulmonary valve; one had Ebstein`s anomaly and one had supramitral ring. Thirty-two patients [56%] experienced anoxic spell. Preoperative pulmonary artery indices were measured in 38 cases, ranging 126-552mm2/M2BSA[n=38, 251$\pm$79mm2/M2BSA]. All infants required a right ventricular outflow tract patch; in 41, the patch extended across the pulmonary valve annulus, in 13 of them, monocusps were constructed. All had patch closure of ventricular septal defect. Two infants had REV operation for avoiding injury to the canal branch of the right coronary artery which cross the right ventricular out flow tract. Post repair PRV/LV were measured at operating room in 40 cases, which revealed mean value of 0.49$\pm$0.12 [range: 0.25-0.74]. The hospital mortality was 10.3% [6 patients], and causes of deaths were right heart failure due to sustained right ventricular hypertension[4] and right ventricular outflow tract obstruction, intractablesuraventricular tachyarrhythmia[1], hypoxia[1] due to residual right to left shunt across the atrial septal defect in patient associated with Ebstein`s anomaly. All infants were doing well at follow-up from 1 to 101 months[20.6 months /patient, 1, 072 patient-month] Serial postoperative echocardiograms revealed no residual ventricular septal defects and estimated RVOT gradients between 0 and 40 mmHg except 3 cases [50, 50, 60 mmHg]. There were no late deaths and late ventricular arrhythmias or congestive heart failure. Redo operations were done in 2 cases because of residual right ventricular outflow tract obstruction. This experience with infants with tetralogy of Fallot suggests that, if mortality is tolerable, eletive repair of tetralogy of Fallot could be reasonably undertaken during the first year of life, and even better results could be anticipated along with improvement of methods of myocardial protection and postoperative care.

  • PDF