• Title/Summary/Keyword: Anoxic

Search Result 443, Processing Time 0.027 seconds

Development of Optimal Treatment Process Train of Leachate from Industrial Waste Disposal Site

  • Han Gee Baek;Choi Kwang Soo;Min Man Gi;Han Young Hwan;Im Jung Hoon;Lee Hae Goon;Choi Myung Won;Kim Chang Won;Park Dong Keun
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • v.2 no.2
    • /
    • pp.115-121
    • /
    • 1998
  • Train of chemical and biological processes was investigated to treat leachate from industrial waste landfill. Organics and nitrogen concentrations of landfill leachate studied in this research were high and their BOD/COD ratio was 0.3. Biological process should be combined with chemical process for optimum treatment of leachate. PAC(Polyaluminium chloride) was the best coagulant among three chemicals tested, and the optimum condition of PAC coagulation was pH 6 and 1,250 mg/L of dosage. When SBR was operated for simultaneous removal of organics and nitrogen, removal efficiency of COD and T-N reached over $82\%,\;71\%,$ respectively and time distribution of 2/4/2/1 was most effective for one cycle of anoxic/aerobic/anoxic/aerobic.

  • PDF

Simplification of ASM No. 1 Using Aerobic-Anoxic SBR (호기-무산소 SBR 반응조를 이용한 ASM No. 1 모델의 간략화)

  • Kim, Shin Geol;Choi, In Su;Koo, Ja Yong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.4
    • /
    • pp.409-420
    • /
    • 2007
  • ASM No. 1 is a very useful model to analyze wastewater treatment system removing organic carbon and nitrogen material. But it isn't adequate to control the wastewater treatment system with real time since it has many material divisions and parameters. So, the purpose of this study is the simplification of ASM No. 1 to control the wastewater treatment system. ASM No. 1 was changed with the model which has 3 material divisions(COD, $NH_4{^+}$, $NO_3{^-}$) and two phases(Aerobic and Anoxic condition). SBR was running with two phases(Phase I and II). Phase II running 20 minutes with aerobic time was used for deciding model parameters and Phase I running 12 minutes with aerobic time was used for proving the simplified model. The simplified model was compared with ASM No. 1 using data of Phase I and II. As a result of model comparison, the simplified model has enough ability to express the variation of $NH_4{^+}$ compound.

Study on the optimum operation system of Sequencing Batch Reactor (연속 회분식 반응조의 최적 운전시스템에 관한 연구)

  • Eom, Tae Kyu;Ko, Eun Joo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.13 no.4
    • /
    • pp.54-61
    • /
    • 1999
  • SBR process used to evaluate the removal of organics, nitrogen and phosphorus on the basis of a report of research on a precedence at various operation cycle and condition change. Effluent concentration of COD were 50mg/l, 50mg/l, 90mg/l respectively, The removal rates of COD were nearly over 95% at Run 1, 2 and 4. But at Run 3, Effluent concentration of COD was 255.0mg/l, The removal rate of COD was 87% at Run 3. As Oxic/Anoxic rate was fixed and operating cycle of Oxic/Anoxic was changed, the removal rates of T-N were 74.7%, 46.9%, 28.5%, 63.3% respectively at Run 1~4. The case of Run 1 was best result. The removal rates of T-P was appeared in proportion to T-N removal rates and rest of $NO_2-N$. The removal rates of T-P were 51.2%, 35.5%, 41.5%, 51.9% respectively. The removal rates of COD, T-N, T-P were influenced on the change of SBR operation cycle. As organic loading rate was $1.43kgCOD/m^3day$ and C/N ratio was 3.0, operation cycle of Run 1 was best condition of T-N removal rates and T-P removal.

  • PDF

Study on Removal of DOC for Effluent from Nitrification and Denitrification Process with Zeolite by Combined Process of Coagulation and UF Membrane (제올라이트를 첨가한 질산화 탈질공정에서 응집과 UF공정을 이용한 처리수내 용존 유기물질 제거 연구)

  • Han, Jang Hyuk;Yoon, Tai Il;Cho, Kyung Chul;Song, Jea Yong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.5
    • /
    • pp.537-546
    • /
    • 2005
  • This study was carried out to evaluate EPS and SMP variation of sludge and effluent in nitrification and denitrification process with zeolite addition, a possible reduction of effluent DOC by URC(Ultra Rapid Coagulation) process. As a biological wastewater treatment result, EPS formation of both aeration and anoxic sludges are not affect by SRT variation. However, EPS concentration of sludges is higher in aeration tank than in anoxic tank by 6~8 mg EPS/ g VSS. Linear relationship between SMP to DOC indicates that SMP of bulk solution contributes to most of the biological treatment effluent DOC. DOC and turbidity removal efficiency was more improved with URC process than in a conventional coagulation. For pretreatment of UF filtration DOC removal was advanced by URC process than only UF filtration.

Enbancement of Treatement Efficiency in a Biological Nutrient Removal Process by addition of Volatile Fatty Acids (휘발성 지방산의 주입을 통한 생물학적 영양염류 제거공정의 효율증진에 관한 연구)

  • Choung, Yoon Kyoo;Ko, Kwang Baik;Kim, Sue Jin;Yim, Seong Keun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.10 no.3
    • /
    • pp.73-82
    • /
    • 1996
  • The removal efficiencies of organic substrates, nitrogen and phosphorus in the anaerobic-aerobic biological phosphorus removal process were investigated by addition of acetic acid, propionic acid and butyric acid which are normal volatile fatty acids contained in anaerobic digester supernatants. Substrate utilization coefficients for the phosphorus release and uptake were also estimated. The effect of a VFA, which showed higher phosphorus removal efficiency than the other VFAs did, was also studied in an anaerobic-aerobic-anoxic biological nutrient removal process. For the anaerobic-aerobic process added by VFA, the phosphorus removal efficiencies were up to about 68%, 55% and 61% for the reactors of acetic acid, propionic acid and butyric acid added, respectively, which indicates the efficiencies were increased by about 8-21%, comparing to that of 47% for the reactor with no VFA added. There were no significant difference in removal efficiencies for organic substrate and $NH_3-N$ without regard to addition of VFA. However, the removal efficiency of total nitrogen was increased in the case of VFA added, since $NO_3-N$ was less produced. For the anaerobic-aerobic-anoxic process added VFA, the removal efficiencies for $NH_3-N$ and $PO{_4}^{3-}-P$ were increased by 5% and 13%, respectively, comparing with them in the reactors not added VFA.

  • PDF

Simplification of ASM No. 2 using Anaerobic-Aerobic-Anoxic SBR (혐기-호기-무산소 SBR 반응조를 이용한 ASM No. 2 모델의 간략화에 관한 연구)

  • Kim, Shin Geol;Choi, In Su;Koo, Ja Yong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.1
    • /
    • pp.3-14
    • /
    • 2008
  • ASM No. 2(Activated sludge model No. 2) is very useful model to analyze the wastewater treatment which removes nitrogen and phosphorus. But, it is difficult to apply ASM No. 2 to control of wastewater treatment since it has 17 material divisions and 46 parameters. So the purpose of this study was the simplification of ASM No. 2 and the provement of simplification model. Firstly ASM No. 2 was simplified with 5 material division and three phases(Anaerobic, aerobic, anoxic phases). The simplified model was proved by R-square using track study data. As a result of provement, the values of R-square in ${NH_4}^+$ were 0.9815 in ASM No. 2 and 0.9250 in simplified model and in ${NO_3}^-$ were 0.8679 in ASM No. 2 and 0.7914 in simplified model and in ${PO_4}^{3-}$ are 0.9745 in ASM No. 2 and 0.9187 in the simplified model when the ability to express the material variation was compared by R-square. So, the simplified model has enough ability to express the variation of ${NH_4}^+$, ${NO_3}^-$ and ${PO_4}^{3-}$.

Nutrients removal on Oxic/Anoxic time ratio in 2-stage-intermittent-aeration reactor (2단 간헐 포기조의 포기/비포기 시간비에 따른 영양염류 제거특성)

  • Kim, Hong Tae;Sin, Seok U;O, Sang Hwa;Gwon, Seong Hyeon
    • Journal of Environmental Science International
    • /
    • v.13 no.7
    • /
    • pp.675-680
    • /
    • 2004
  • This study was conducted to remove organics and nutrients using 2 stage intermittent aeration reactor. First reactor, using suspended microbial growth in intermittent aeration instead of anaerobic reactor in the typical BNR process, used minimum carbon source to release P, and it was possible to reduce ammonia loading going to second reactor. In the second reactor, using moving media intermittent aeration, it was effective to reduce nitrate in non-aeration time by attached microorganisms having long retention time. In aeration time, nitrification and P uptake were taken place simultaneously. From the experiment, two major results were as follows. First, the removal of organics was more than 90%, and optimum aeration/non-aeration time ratio for organic removal was corresponded with aeration/non-aeration time ratio for nitrogen removal. Second, in the first reactor, optimum aeration/non-aeration time ratio was 15/75 (min.) because it was necessary to maintain 75 min. of non-aeration time to suppress of impediment of return nitrate and to lead release of phosphate. In the second reactor, optimum aeration/non-aeration time ratio was 45/90 (min.).

Stoichiometric Study for Nitrogen Removal in Anoxic-oxic Process (무산소-산소 공정에서 양론적 질소제거 연구)

  • Lee, Byung-Dae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.11
    • /
    • pp.1222-1227
    • /
    • 2005
  • Optimal sludge recycling ratio for maximum total nitrogen(TN) removal efficiency was calculated stoichiometrically using nitrification and denitrification reaction with given influent water qualities in anoxic-oxic process which was one of the popular nitrogen removal system. The water quality items for stoichiometric calculation were ammonia, nitrite, nitrate, alkalinity, COD, and dissolved oxygen which could affect nitrification and denitrification. Optimal sludge recycling ratio for maximum TN removal efficiency was expressed by those five influent water qualities. TN concentration calculated stoichiometrically had kept good relationship with reported TN concentration in each tank and final effluent. In addition, it was possible to expect the TN concentration in final effluent by stoichiometric calculation within ${\pm}5.0\;mg/L$.