• 제목/요약/키워드: Anodized surface

검색결과 232건 처리시간 0.026초

양극산화로 제작된 티타늄의 발색효과 연구 (Color Evolution in Anodized Titanium)

  • 송오성;홍석배;이정임
    • 한국표면공학회지
    • /
    • 제35권5호
    • /
    • pp.273-278
    • /
    • 2002
  • We oxidized pure titanium by anodizing oxidation process in the range of 590V, within 1.5A, 30seconds. we investigated color evolution with a spectrophotometer. Surface images and surface roughness were characterized by an optical microscope and an atomic force microscope, respectively. Below the thickness of 40 $\mu\textrm{m}$, metallic yellow, blue, and pink colorsn were obtained. Lightness decreased, increased, and decreased again as titanium oxide thickness increased. Blue color at the applied voltage of 30V showed the best lightness and reproducibility with surface roughness below l$\mu\textrm{m}$. Bare titanium and titanium oxide films had micro pits more than 10ea/$\mu\textrm{m}^2$. We report that we successfully made colors by varing thickness below 40$\mu\textrm{m}$ with anodizing oxidation of method.

Heavy Metal Adsorption of Anodically Treated Activated Carbon Fibers in Aqueous Solution

  • Park, Soo-Jin;Kim, Young-Mi
    • Carbon letters
    • /
    • 제4권1호
    • /
    • pp.21-23
    • /
    • 2003
  • In this work, the effect of anodic oxidation treatment on Cr(VI) ion adsorption behaviors of activated carbon fibers (ACFs) was investigated. The aqueous solutions of 10 wt% $H_3PO_4$ and $NH_4OH$ were used for acidic and basic electrolytes, respectively. Surface characteristics and textural properties of ACFs were determined by XPS and $N_2$ adsorption at 77 K. The heavy metal adsorption of ACFs was conducted by ICP. As a result, the adsorption amount of the anodized ACFs was improved in order of B-ACFs > A-ACFs > pristine-ACFs. In case of the anodized treated ACFs, the specific surface area was decreased due to the pore blocking or pore destroying by acidic electrolyte. However, the anodic oxidation led to an increase of the Cr(VI) adsorption, which can be attributed to an increase of oxygen-containing functional groups, such as, carboxylic, lactonic, and phenolic groups. It was clearly found that the Cr(VI) adsorption was largely influenced by the surface functional groups, in spite of the reduced specific surface area of the ACFs.

  • PDF

Al-Mg합금의 컬러에 미치는 양극산화 및 착색처리의 영향 (Effect of Anodizing and Dyeing Treatments on Coloring of Al-Mg)

  • 배성화;이현우;손인준
    • 한국표면공학회지
    • /
    • 제52권1호
    • /
    • pp.30-36
    • /
    • 2019
  • In this study, we investigated the effects of anodizing time, dyeing treatment time, and variations in coloring concentration on the color of an AA5052 alloy processed by dye-treated anodizing. The outward color of the anodized film changed to deep red according to increases in anodizing time, dyeing treatment time, and coloring concentration; accordingly, lightness $L^*$ decreased and saturation $a^*$ and $b^*$ increased. The concentration of the dye and the UV-visible absorbance showed a nearly perfect linear relationship, allowing a quantitative analysis of the absorbed dye. Because the quantity of absorbed dye increased as anodizing time, dyeing treatment time, and coloring concentration increased, the outward color of the anodized film deepened. In addition, from the GD-OES depth profile, we found that the dye was preferentially absorbed on the surface of the porous anodized film.

알루미늄 6061 합금의 표면 나노 구조물 변화에 따른 방빙 특성 연구 (Anti-Icing Characteristics of Aluminum 6061 Alloys According to Surface Nanostructure)

  • 김리안;정찬영
    • Corrosion Science and Technology
    • /
    • 제21권6호
    • /
    • pp.476-486
    • /
    • 2022
  • Recently, aluminum 6061 instead of copper alloy is used for cooling heat exchangers used in the internal combustion of engines due to its economic feasibility, lightweight, and excellent thermal conductivity. In this study, aluminum 6061 alloy was anodized with oxalic acid, phosphoric acid, or chromic acid as an anodizing electrolyte at the same concentration of 0.3 M. After the third anodization, FDTS, a material with low surface energy, was coated to compare hydrophobic properties and anti-icing characteristics. Aluminum was converted into an anodization film after anodization on the surface, which was confirmed through Energy Dispersive X-ray Spectroscopy (EDS). Pore distance, interpore distance, anodization film thickness, and solid fraction were measured with a Field Emission Scanning Electron Microscope (FESEM). For anti-icing, hydrophobic surfaces were anodized with oxalic acid, phosphoric acid, or chromic acid solution. The sample anodized in oxalic acid had the lowest solid fraction. It had the highest contact angle for water droplets and the lowest contact hysteresis angle. The anti-icing contact angle showed a tendency to decrease for specimens in all solutions.

양극산화로 제조된 다공성 나노구조 철 산화막의 열처리 조건에 따른 광전기화학적 성질 (Photoelectrochemical performance of anodized nanoporous iron oxide based on annealing conditions)

  • 정동헌;유정은;이기영
    • 한국표면공학회지
    • /
    • 제56권4호
    • /
    • pp.265-272
    • /
    • 2023
  • Photoelectrochemical (PEC) water splitting is one of the promising methods for hydrogen production by solar energy. Iron oxide has been effectively investigated as a photoelectrode material for PEC water splitting due to its intrinsic property such as short minority carrier diffusion length. However, iron oxide has a low PEC efficiency owing to a high recombination rate between photoexcited electrons and holes. In this study, we synthesized nanoporous structured iron oxide by anodization to overcome the drawbacks and to increase surface area. The anodized iron oxide was annealed in Ar atmosphere with different purging times. In conclusion, the highest current density of 0.032 mA/cm2 at 1.23 V vs. RHE was obtained with 60 s of pursing for iron oxide(Fe-60), which was 3 times higher in photocurrent density compared to iron oxide annealed with 600 s of pursing(Fe-600). The resistances and donor densities were also evaluated for all the anodized iron oxide by electrochemical impedance spectra and Mott-Schottky plot analysis.

Oxide Nanolayers Grown on New Ternary Ti Based Alloy Surface by Galvanic Anodizing-Characteristics and Anticorrosive Properties

  • Calderon Moreno, J.M.;Drob, P.;Vasilescu, C.;Drob, S.I.;Popa, M.;Vasilescu, E.
    • Corrosion Science and Technology
    • /
    • 제16권5호
    • /
    • pp.257-264
    • /
    • 2017
  • Film of new Ti-15Zr-5Nb alloy formed during galvanic anodizing in orthophosphoric acid solution was characterized by optical microscope, scanning electron microscope (SEM), energy dispersive spectroscopy (EDS), and Raman micro-spectroscopy. Its anticorrosive properties were determined by electrochemical techniques. The film had a layer with nanotube-like porosity with diameters in 500-1000 nm range. The nano layer contained significant amounts of P and O as well as alloying element. Additionally, Raman micro-spectroscopy identified oxygen as oxygen ion in $TiO_2$ anatase and phosphorous as $P_2O_7{^{4-}}$ ion in phosphotitanate compound. All potentiodynamic polarization curves in artificial Carter-Brugirard saliva with pH values (pH= 3.96, 7.84, and 9.11) depending on the addition of 0.05M NaF revealed nobler behavior of anodized alloy and higher polarization resistance indicating the film is thicker and more compact nanolayer. Lower corrosion rates of the anodized alloy reduced toxicity due to less released ions into saliva. Bigger curvature radii in Nyquist plot and higher phase angle in Bode plot for the anodized alloy ascertain a thicker, more protective, insulating nanolayer existing on the anodized alloy. Additionally, ESI results indicate anodized film consists of an inner, compact, barrier, layer and an outer, less protective, porous layer.

다양한 rhBMP-2 코팅 임플란트 표면에서의 인간 간엽 줄기세포의 부착, 증식, 분화반응 분석 (Analysis of attachment, proliferation and differentiation response of human mesenchymal stem cell to various implant surfaces coated with rhBMP-2)

  • 이인구;한인호;황선욱;류재준
    • 대한치과보철학회지
    • /
    • 제50권1호
    • /
    • pp.44-52
    • /
    • 2012
  • 연구 목적: 본 실험은 거친 표면으로 유의성 있는 줄기세포반응을 나타냈던 4 가지의 티타늄 표면 위에 rhBMP-2를 코팅했을 때 어떤 유의한 줄기세포반응(세포부착, 증식, 분화)이 나타나는지 비교 분석함으로 rhBMP-2 코팅을 위한 가장 적절한 표면을 평가하기 위해 시행되었다. 연구 재료 및 방법: 대조군인 기계절삭표면(machined surface)과 실험군인 양극산화(anodized), RBM, SLA 표면에 rhBMP-2를 코팅한 후 코팅하지 않은 표면과 같이 8가지 표면 위에 인간줄기세포를 배양하였다. 배양 후 24시간 후 SEM을 통해 줄기세포의 부착을 평가하였고 배양 3, 7, 14일후MTT와 ALP 검사를 통해 줄기세포의 증식과 분화반응을 평가하였다. 그리고 배양 7일후RT-PCR 검사를 통해 Type I collagen, osteocalcin, osteopontin의 유전자 발현의 변화를 평가하였다. 결과: SEM 평가에서 4가지 rhBMP-2 표면이 코팅하지 않은 표면에 비해 세포부착 면적이 넓고 긴밀하며 세포돌기가 더 많이 관찰되었다. 양극산화 rhBMP-2코팅표면에서 가장 두드러지게 관찰되었다. MTT 검사에서 크게 의미 있는 차이는 나타나지 않았다. ALP검사에서 양극산화 rhBMP-2코팅 표면은 대조군과 비교해서 (3, 14일) 또 RBM rhBMP-2 코팅 표면과 비교해서 (14일) 유의성 있는 ALP 활성도의 증가를 나타내었다(P<.05). RT-PCR 검사에서 osteocalcin과 osteopontin의 유전자 발현은 양극산화 rhBMP-2코팅 표면에서 높게 나타났다. 결론: 양극산화 rhBMP-2코팅표면이 줄기세포의 부착과 분화실험에서 대조군표면과 rhBMP-2를 코팅한 기계절삭표면이나 RBM 표면에 비해 유의성 있는 증가를 나타냈다(P<.05).

양극산화 불꽃 방전에 의한 Ti 산화피막의 표면특성 (Characterization of Surface at Ti Oxide Films Converted by Anodic Spark Discharge)

  • 송재주;한병성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 하계학술대회 논문집 Vol.7
    • /
    • pp.545-546
    • /
    • 2006
  • This study was performed to investigate the surface properties of electrochemically oxidized pure titanium by anodic spark discharging method. Commercially pure titanium plates of $10{\times}20{\times}1[mm]$ in dimensions were polished sequentially emery paper. Anodizing was performed at current density of $76.2\;[mA/cm^2]$, application voltage of 290, 350, 400 [V] using a regulated DC power supply, which allowed automatic transition constant current when a preset maximum voltage has been reached. The Ti surface oxided films was characterized by scanning electron microscope(SEM). The precipitation of HA(Hydroxyapatite) crystals on anodized surface was greatly accelerated by hydrothermal treatment. The concentrations of DL-$\alpha$-Glycerolphosphate Magnesiurn(DL-$\alpha$-GP-Mg) salt and Ca acetate in an electrolyte was highly affected the precipitation of HA crystals converted by Ti Anodized oxide films by Shape of Impulse Voltage.

  • PDF

절삭가공이 알루미늄 경질 아노다이징 피막에 미치는 영향 (Effect of Machining on Hard Anodizing Surface of Aluminum)

  • 김수진;문정일
    • 한국기계가공학회지
    • /
    • 제21권8호
    • /
    • pp.87-92
    • /
    • 2022
  • The Al3003 aluminum plate was cut by grinding, milling, sawing, and shearing, and the hard-anodizing surface of the material was investigated. Large burrs were formed during grinding and milling. The brittle anodized film split and migrated along the deformed aluminum surface. During shearing, the hard-anodized film on the blade entry surface cracks and slides along the deforming aluminum. The cutting heat increased the ductility of the aluminum and further promoted burr formation. The oil-based coolant suppressed burrs and prevented chips from sticking to the endmill. It is better to avoid the high cutting speed and slow material feed rate conditions, which increase the cutting temperature and burr in the band saw.

임플랜트 표면처리가 생체활성에 미치는 영향 (EFFECT OF DIFFERENT SURFACE TREATMENTS TO INCREASE BIOCOMPATIBILITY OF DENTAL IMPLANT)

  • 이호진;송광엽;윤태호
    • 대한치과보철학회지
    • /
    • 제44권5호
    • /
    • pp.594-605
    • /
    • 2006
  • Statement of problem: Modification of titanium implant surface has potential to ensure clinically favorable performance that several surface modification technologies have been introduced. Among the methods. anodizing method and sol-gel hydroxyapatite coating method have gained much interest due to its roughness and chemical composition of the coating layer, but more of its biocompatibility result is required. Purpose : The purpose of this study was to compare bone-implant interface shear strength of four different surface treated implants as time elapsed. Resonance frequency analysis(RFA) and removal torque measurement methods were employed to measure implant stability at one week and six week after implantation. Material and method: A total of 80 screw-shaped implant [20 machined, 20 resorbable media blasted(RBM), 20 anodized, and 20 anodized+hydroxyapatite sol-gel coated] were prepared, and one of each group was implanted in the tibia of a New Zealand white rabbit that total 20 of them were used. In order to test the implant stability and implant-tissue interface contact changing in the bone bed, each 10 rabbit were sacrificed 1 week and 6 week later while resonance frequency and removal torque were measured. One-way analysis of variance and the Tukey test were used for statistical analysis. Results : The results were as follows. 1. There was no statistically significant difference of implant stability quotients(ISQ) value in RFA between individual groups after 1 week of implantation and 6 weeks(p>0.05). But, there was statistically significant increase of ISQ value in 6 weeks group compared to 1 week group(p<0.05). 2. There was no statistically significant difference in removal torque analysis between individual groups after 1 week of implantation and 6 weeks(p>0.05). but there was statistically significant increase in all 4 groups after 6 weeks compared to 1 week later(p<0.05). 3. There was no statistically significant difference in removal torque analysis between anodized group and HA coating after anodic oxidation 6 weeks later(p>0.05), but significant difference was appeared in both groups compared to RBM group and smooth-machined group(p<0.05). Conclusions : It can be suggested that changes in surface characteristics affect bone reactions. Anodized and anodized+hydroxyapatite sol-gel coating showed significantly improved bone tissue response to implants, but further study on the effect of hydroxyapatite dissolution is needed.