• Title/Summary/Keyword: Anodic limit

Search Result 54, Processing Time 0.026 seconds

Determination of Ag(Ⅰ) Ion at a Modified Carbon Paste Electrode Containing N,N'-Diphenyl Oxamide

  • Won, Mi-Sook;Yeom, Jeong-Sik;Yoon, Jang-Hee;Jeong, Euh-Duck;Shim, Yoon-Bo
    • Bulletin of the Korean Chemical Society
    • /
    • v.24 no.7
    • /
    • pp.948-952
    • /
    • 2003
  • New approach for the determination of Ag(I) ion was performed by using a carbon paste electrode (CPE) containing N,N'-Diphenyl oxamide (DPO) with anodic stripping voltammetry. The CMEs have been prepared by making carbon paste mixtures containing an appropriate amount of DPO salt coated onto graphite particles to analyze trace metal ions via complexation followed by stripping voltammetry. Various experimental parameters affecting the response, such as pH, deposition time, temperature, and electrode composition, were carefully optimized. Using differential pulse anodic stripping voltammetry, the logarithmic linear response range for the Ag(I) ion was 1.0 × $10^{-7}$ - 5.0 × $10^{-9}$ M at the deposition time of 10 min, with the detection limit was 7.0 × $10^{-10}$ M. The detection limit adopted from anodic stripping differential pulse voltammetry was 7.0 × $10^{-10}$ M for silver and the relative standard deviation was ± 3.2% at a 5.0 × $10^{-8}$ M of Ag(I) ion (n = 7). The proposed electrode shows a very good selectivity for Ag(I) in a standard solution containing several metals at optimized conditions.

Assay of Dinitrotoluene on a Contaminated Soil Sample with an Anodic Stripping Peak Current

  • Ly, Suw-Young;Lee, Chang-Hyun;Jung, Young-Sam
    • Journal of Environmental Science International
    • /
    • v.15 no.11
    • /
    • pp.997-1002
    • /
    • 2006
  • This report presents a voltammetric assay of dinitrotoluene using a DNA immobilized onto a carbon nanotube paste electrode (PE). The cyclic voltammetry (CV) and square wave (SW) stripping voltammetry parameters of the optimized conditions were obtained. An anodic peak current appeared at 0.3 V (versus Ag/AgCl) in a 0.1-M $NH_4H_2PO_4$ electrolyte solution. The detection limit was found to be $0.6ngL^{-1}$(S/N = 10), within a deposition time of 100 sec.

Determination of Germanium(IV) by Differential Pulse Anodic Stripping Voltammetry(I) (Differential Pulse Anodic Stripping Voltammetry법에 의한 게르마늄 분석에 관한 연구(제1보))

  • 문동철
    • YAKHAK HOEJI
    • /
    • v.27 no.1
    • /
    • pp.1-10
    • /
    • 1983
  • Voltammetric deposition and differential pulse anodic stripping (DPASV) of Ge(IV)at a gold electrode was investigated. Germanium (IV) exhibits two stripping peaks by DPASV in sodium borate solution, the first peak at about -1.1v. vs SCE and the second one, in the range of -0.6 to -0.2v. vs SCE. Factors affecting the sensitivity and precision included the nature of working electrode, supporting electrolytes, deposition potential, deposition time, pH, pulse height, voltage scan rate. The relative standard deviation of the measurements of the peak currents, for 100ng/ml Ge(IV), was less than ${\pm}3%$. The detection limit of Ge(IV) was 0.01ng/ml. Percent recovery in the extraction procedure of Ge(IV) from matrices by benzene in c-HCl, followed by back extraction with saturated borax solution, ranged from 96 to 104%.

  • PDF

Label-Free Electrochemical DNA Detection Based on Electrostatic Interaction between DNA and Ferrocene Dendrimers

  • Lee, Ji-Young;Kim, Byung-Kwon;Hwang, Seong-Pil;Lee, Young-Hoon;Kwak, Ju-Hyoun
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.11
    • /
    • pp.3099-3102
    • /
    • 2010
  • A label-free DNA detection method was developed for a simple electrochemical DNA sensor with a short assay time. Self-assembled monolayers of peptide nucleic acid were used as a probe on gold electrodes. The formation of the self-assembled monolayers on the gold electrodes was successfully checked by means of cyclic voltammetry. The target DNA, hybridized with peptide nucleic acid, can be detected by the anodic peak current of ferrocene dendrimers, which interact electrostatically with the target DNA. This anodic peak current was measured by square wave voltammetry at 0.3 V to decrease the detection limit on the order of the nanomolar concentrations. As a result, the label-free electrochemical DNA sensor can detect the target DNA in concentrations ranging from 1 nM to $1\;{\mu}M$ with a detection limit of 1 nM.

Detection of Trace Copper Metal at Carbon Nanotube Based Electrodes Using Squarewave Anodic Stripping Voltammetry

  • Choi, Changkun;Jeong, Youngsam;Kwon, Yongchai
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.3
    • /
    • pp.801-809
    • /
    • 2013
  • We investigate sensitivity and limit of detection (LOD) of trace copper (Cu) metal using pristine carbon nanotube (CNT) and acidified CNT (ACNT) electrodes. Squarewave based anodic stripping voltammetry (SWASV) is used to determine the stripped Cu concentration. Prior to performing the SWASV measurements, its optimal conditions are determined and with that, effects of potential scan rate and $Cu^{2+}$ concentration on stripping current are evaluated. The measurements indicate that (1) ACNT electrode shows better results than CNT electrode and (2) stripping is controlled by surface reaction. In the given $Cu^{2+}$ concentration range of 25-150 ppb, peak stripping current has linearity with $Cu^{2+}$ concentration. Quantitatively, sensitivity and LOD of Cu in ACNT electrode are 9.36 ${\mu}A\;{\mu}M^{-1}$ and 3 ppb, while their values are 3.99 ${\mu}A\;{\mu}M^{-1}$ and 3 ppb with CNT electrode. We evaluate the effect of three different water solutions (deionized water, tap water and river water) on stripping current and the confirm types of water don't affect the sensitivity of Cu. It turns out by optical inspection and cyclic voltammetry that superiority of ACNT electrode to CNT electrode is attributed to exfoliation of CNT bundles and improved interfacial adhesion occurring during oxidation of CNTs.

Effect of Electrolytes on Electrochemical Properties of Magnesium Electrodes

  • Ha, Se-Young;Ryu, Anna;Cho, Woosuk;Woo, Sang-Gil;Kim, Jae-Hun;Lee, Kyu Tae;Kim, Jeom-Soo;Choi, Nam-Soon
    • Journal of Electrochemical Science and Technology
    • /
    • v.3 no.4
    • /
    • pp.159-164
    • /
    • 2012
  • Magnesium (Mg) deposition and dissolution behaviors of 0.2 M $MgBu_2-(AlCl_2Et)_2$, 0.5 M $Mg(ClO_4)_2$, and 0.4M $(PhMgCl)_2-AlCl_3$-based electrolytes with and without tris(pentafluorophenyl) borane (TPFPB) are investigated by ex situ scanning electron microscopy (SEM) and galvanostatic cycling of Mg/copper (Cu) cells. To ascertain the factors responsible for the anodic stability of the electrolytes, linear sweep voltammogrametry (LSV) experiments for various electrolytes and solvents are conducted. The effects of TPFPB as an additive on the anodic stability of 0.4M ($(PhMgCl)_2-AlCl_3$/THF electrolyte are also discussed.

Anodic Stripping Voltammetric Detection of Arsenic(III) at Platinum-Iron(III) Nanoparticle Modified Carbon Nanotube on Glassy Carbon Electrode

  • Shin, Seung-Hyun;Hong, Hun-Gi
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.11
    • /
    • pp.3077-3083
    • /
    • 2010
  • The electrochemical detection of As(III) was investigated on a platinum-iron(III) nanoparticles modified multiwalled carbon nanotube on glassy carbon electrode(nanoPt-Fe(III)/MWCNT/GCE) in 0.1 M $H_2SO_4$. The nanoPt-Fe(III)/MWCNT/GCE was prepared via continuous potential cycling in the range from -0.8 to 0.7 V (vs. Ag/AgCl), in 0.1 M KCl solution containing 0.9 mM $K_2PtCl_6$ and 0.6 mM $FeCl_3$. The Pt nanoparticles and iron oxide were co-electrodeposited into the MWCNT-Nafion composite film on GCE. The resulting electrode was examined by cyclic voltammetry (CV), scanning electron microscopy (SEM), and anodic stripping voltammetry (ASV). For the detection of As(III), the nanoPt-Fe(III)/MWCNT/GCE showed low detection limit of 10 nM (0.75 ppb) and high sensitivity of $4.76\;{\mu}A{\mu}M^{-1}$, while the World Health Organization's guideline value of arsenic for drinking water is 10 ppb. It is worth to note that the electrode presents no interference from copper ion, which is the most serious interfering species in arsenic detection.

Integrated Microdisk Gold Electrode Modified with Metal-porphyrin and Metal-phthalocyanines for Nitric Oxide Determination in Biological Media

  • Kim, Il-Kwang;Bae, Hyun-Ok;Oh, Gi-Soo;Chung, Hun-Taeg;Kim, Young-Jin;Chun, Hyun-Ja
    • Bulletin of the Korean Chemical Society
    • /
    • v.24 no.11
    • /
    • pp.1579-1584
    • /
    • 2003
  • An integrated gold microdisk electrode was constructed and modified with metal-porphyrin or metal-phthalocyanines for NO determination in biological media. Microanalysis of NO using square wave anodic stripping voltammetry in $1\;{\times}\;10^{-2}$ M $HClO_4$ was optimal when the accumulation potential was 0.1 V, frequency 100 Hz, and the scan rate was 200 mV/s. When the electrode was modified with metal-porphyrin or metal-phthalocyanines, the anodic peak currents of NO increased due to the catalytic oxidation of NO. In case of Fe(II)-phthalocyanine modified electrode, the peak currents remarkably increased and the sensitivity was high. The calibration curve had good linearity in the range from $3.6\;{\times}\;10^{-5}$ M to $7.2\;{\times}\;10^{-7}$ M, and the detection limit was $5.7\;{\times}\;10^{-7}$ M. For the structural stability and increased sensitivity, Fe(II)-phthalocyanine modified gold microdisk electrode coated with Nafion was applied to determination of NO released from cultured macrophase.

Determination of Heavy Metals in Sea Salt Using Anodic Stripping Voltammetry

  • Kim, Yong Hoon;Kim, Giyoung
    • Food Engineering Progress
    • /
    • v.21 no.2
    • /
    • pp.180-186
    • /
    • 2017
  • Salt, as food, is the most essential element for human survival due to its significant physiological functions. Here, we report the simultaneous detection of Pb and Cd in sea salt by square wave anodic stripping voltammetry (SWASV). Stripping voltammetric measurements were conducted using a manufactured rotating disk electrode system (MRDES). The detection limit was $3.6{\pm}0.18{\mu}gL^{-1}$ for Pb and $3.9{\pm}0.37{\mu}gL^{-1}$ Cd in NaCl solution. When the pH increased from 5.5 to 8.5, the peak currents of Pb and Cd decreased. At a pH of 8.3, the ratio of the current drop compared with that at a pH of 5.5 was 0.6 for Pb and 0.73 for Cd. The concentrations corrected by the current drop are in agreement with the concentrations obtained with ICP (inductively coupled plasma). This system demonstrates the reliable detection of heavy metals in aqueous media and, at a high $Na^+$ concentration, the successful application for the determination of Pb and Cd in sea salts.

Determination of Trace Level Mercury in Bio-Materials by Square Wave Anodic Stripping Voltammetry (네모파 산화전극벗김 전압전류법을 이용한 생체시료 중의 미량 수은 분석)

  • Kim Il Kwang;Park Sung Woo;Han Jong Hyun;Kim Youn Geun;Chun Hyun Ja;Park Kyung Ok
    • Journal of the Korean Chemical Society
    • /
    • v.37 no.5
    • /
    • pp.477-482
    • /
    • 1993
  • The determination of trace level mercury in bio-materials has been investigated by the square wave anodic stripping voltammetry (ASV)-technique at glassy carbon electrode. Prior to analysis, the bio-materials were digested with HNO3/H2SO4 mixture and KMnO4 was added to complete the oxidation. The detection limit of the mercury varied greatly with deposition time, deposition potential, pH and stirring rate. When deposition is carried out for 240 sec with 400 rpm stirring at -1.0 volts vs. Ag/AgCl, the detection limit was below $0.5\;ppb\;(2.5{\times}10^{-9} M)$. The method is recommended for trace level mercury analysis of biomaterials because this procedure is time saving and has higher sensitivity.

  • PDF