• Title/Summary/Keyword: Anode effect

Search Result 497, Processing Time 0.025 seconds

Fundamental Mechanisms of Platinum Catalyst for Oxygen Reduction Reaction in Fuel Cell: Density Functional Theory Approach (연료전지 산소환원반응 향상 위한 백금 촉매의 구조적 특성: 밀도범함수이론 연구)

  • Kang, Seok Ho;Lee, Chang-Mi;Lim, Dong-Hee
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.5
    • /
    • pp.242-248
    • /
    • 2016
  • The overall reaction rate of fuel cell is governed by oxygen reduction reaction (ORR) in the cathode due to its slowest reaction compared to the oxidation of hydrogen in the anode. The ORR efficiency can be readily evaluated by examining the adsorption strength of atomic oxygen on the surface of catalysts (i.e., known as a descriptor) and the adsorption energy can be controlled by transforming the surface geometry of catalysts. In the current study, the effect of the surface geometry of catalysts (i.e., strain effect) on the adsorption strength of atomic oxygen on platinum catalysts was analyzed by using density functional theory (DFT). The optimized lattice constant of Pt ($3.977{\AA}$) was increased and decreased by 1% to apply tensile and compressive strain to the Pt surface. Then the oxygen adsorption strengths on the modified Pt surfaces were compared and the electron charge density of the O-adsorbed Pt surfaces was analyzed. As the interatomic distance increased, the oxygen adsorption strength became stronger and the d-band center of the Pt surface atoms was shifted toward the Fermi level, implying that anti-bonding orbitals were shifted to the conduction band from the valence band (i.e., the anti-bonding between O and Pt was less likely formed). Consequently, enhanced ORR efficiency may be expected if the surface Pt-Pt distance can be reduced by approximately 2~4% compared to the pure Pt owing to the moderately controlled oxygen binding strength for improved ORR.

Effect of Inorganic Coagulants on the Performance of Electro-Chemical Treatment Process Treating Hospital Wastewater (병원폐수의 전기화학적 처리시 무기응집제 주입 효과에 관한 연구)

  • Jeong, Seung-Hyun;Jeong, Byung-Gon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.10
    • /
    • pp.709-716
    • /
    • 2011
  • Effect of inorganic coagulants dosing on the performance of electro-chemical process was studied when treating hospital wastewater having low electrolyte concentration. It is thought that adding inorganic coagulants caused increase in concentration of electrolyte and this caused increase in free chloride concentration and consequently, caused increase in indirect oxidation effect. Thus, COD removal efficiencies more than doubled in percentage terms at the 2 hrs of reaction time and current density of $1.76A/dm^2$ compared with the results obtained from the parallel experiments without adding inorganic coagulants. T-N removal efficiencies approximately doubled in percentage terms at the 2 hrs of reaction time and 700 ppm of coagulants addition and applied current density of $1.76A/dm^2$ due to the increase of free residual chlorine such as HOCl caused by increase of electrolyte concentration through the addition of inorganic coagulants. Under the same experimental condition, more than 90% of T-P removal efficiencies was obtained. The reason can be explained that increase of chemical adsorption rate between phosphate and insoluble metal compounds caused by dissolved oxygen generated from anode by the increased electrolyte concentration through inorganic coagulants addition make a major role in improving T-P removal efficiencies. It can be concluded that inorganic coagulants addition as the supplemental agent of electrolyte is effective way in improving organic and nutrient salt removal efficiency when treating hospital wastewater having low electrolyte concentration.

A Study on the Effect of Electrolyte Additives on Zn Electrode with Pb3O4 in Zn-AgO Secondary Battery System (Zn-AgO 이차 전지에서 Pb3O4가 첨가된 아연 전극에 미치는 전해질 첨가제의 영향에 관한 연구)

  • Park, Kyung-Wha;Moon, Kyung-Man
    • Journal of the Korean Electrochemical Society
    • /
    • v.6 no.4
    • /
    • pp.242-249
    • /
    • 2003
  • Zn electrode was widely used as an anode material in alkaline battery systems in highly concentrated KOH electrolyte, however it was well known that its cycle life is significantly shortened by growth of dendrite due to the high dissolution of $Zn(OH)_2$ and rapid electrochemical reaction. In this study when by the additives such as $Ca(OH)_2$, Citrate, tartrate and Gluconate were added to $40\%$ KOH electrolyte at solution temperature of $25^{\circ}C$ and the amount of $5wt\%\;Pb_3O_4$ was mixed to Zn electrode and then the effect of $Pb_3O_4$ and additives on the electrochemical behavior of Zn electrode was investigated by Potentiodynamic Polarization Curves, Cyclic Voltammetry, Accelerated Life Cycle lest, and SEM image analyses. The addition of $Pb_3O_4$ reduced the corrosion rate of Zn electrode. The corrosion potential of Zn electrode with $Pb_3O_4$ was higher or lower than that of pure Zn electrode however was not influenced practically to the open circuit voltage. And the addition of 4 type additives had an important role in improving both cycle life in accelerated cycle life test and corrosion resistance. Furthermore the additive of Tartrate indicated comparatively a good effect to corrosion resistance as well as charging-discharging property Improvement among those four type additives.

The Effect of Additives on the Properties of Zn Electrode in Zn/AgO Secondary Battery (Zn/AgO Secondary Battery용 아연 양극의 성능에 미치는 첨가제의 영향)

  • Park, Kyung-Wha;Kim, Chang-Hwan;Moon, Kyung-Man
    • Journal of the Korean Electrochemical Society
    • /
    • v.6 no.3
    • /
    • pp.196-202
    • /
    • 2003
  • We investigated the effect of both 4 types additives and $0.5wt\%\;Pb_3O_4$ which have been reported to show an improvement on the performance of Zinc anode. And Experimental methods such as corrosion potential measurement, potentiodynamic polorization test and charging-discharging cycle life test were carried out in $40 wt\%$ KOH with $Pb_3O_4(0.5, \;10\;&\;2.0wt\%)$ and 4 types additives $(0.4wt\%\;of\;Ca(OH)_2$, 0.025M of Citrate, Tartrate and Gluconate). Corrosion potential was shifted to high direction and also changed to high and low direction repeatedly with increasing of $Pb_3O_4$ quantity. However by adding $0.5wt\%\;Pb_3O_4$, corrosion potential shifted to low direction and showed stable condition. Furthermore it was well known that corrosion resistance was predominantly increased compared to no addition and improved charging-discharging property with adding additives. By SEM analysis, it was concluded that the morphology of surface in case of only $0.5wt\%\;Pb_3O_4$ addition was nearly the same as that of Tartrate additive and in the other additives such as $Ca(OH)_2$, Citrate, Tartrate and Gluconate, their morphologies showed dendrite growth. Eventually it was thought that the additive of Tartrate indicated comparatively good corrosion resistance effect as well as charging-discharging property improvement among those four types additives.

Development of Multiwire Proportional Counter for Measurement of Environmental-level Alpha Particles (환경준위 알파입자측정을 위한 다중선 비례계수기 개발(I))

  • Oh, Pil Jae;Park, Tae Soon;Lee, Min Kie;Kim, Kyung Hwa
    • Analytical Science and Technology
    • /
    • v.9 no.3
    • /
    • pp.262-269
    • /
    • 1996
  • The muiltiwire proportional counter for the measurement of low-level and environmental $\alpha$ particles emitting nuclides was developed. External dimension of the devloped multiwire proportional counter is $350{\times}290{\times}30mm$ and the sensitivity area is $250{\times}200mm$. The wall material of the detector was selected the stainless steel to prevent the deformation by external impact and to obtain minimum background. The anode and cathode wires were used the stainless steel material of diameter $50{\mu}m$. The spacing of each wires are 10.0mm, 5.0mm and the numbers of total wire are 21, 42 lines, respectively. The multiwire proportional counter was designed that the measurement source is placed within the detector to prevent the wall absorption effect and the efficiency variation by various source heights. The characteristics of the developed detector have been investigated to obtain the plateau, operating voltage, background, counting efficiency, position sensitivity and energy resolution etc. For the $^{241}Am$ nuclide, the calculated LLD(Lower Limit of Detection) is 5.0mBq/L which is lower than 40mBq/L of recommended LLD value by ISO(International Organization for Standardization).

  • PDF

A STUDY ON THE EFFECT OF ORTHODONTIC FORCES AND EXOGENOUS ELECTRIC CURRENTS ON $PGE_2$ CONTNET OF ALVEOLAR BONE IN CATS (교정력 및 외인성 전류가 고양이 치조골의 prostaglandin $E_2$에 미치는 영향에 관한 연구)

  • Kim, Jong-Tae;Kim, Joong-Soo;Yang, Won-Sik
    • The korean journal of orthodontics
    • /
    • v.14 no.2
    • /
    • pp.203-215
    • /
    • 1984
  • This experiment was performed to explore the effect of electric currents and orthodontic forces on bone $PGE_2$ content and orthodontic tooth movement on cats. Stainless steel electrodes were connected a power pack consisting of five miniature batteries, a transistor, and a resistor. The current $(10{\pm}2{\mu}A)$ was provided by a constant source encased in a palatal acrylic plate. In first experiment, the cathode was placed mesial to the right maxillary canine tooth and the anode was positioned distal to the tooth, Sham electrodes were placed new the left cuspid, to serve as control. Nine cats were divided into three groups evenly. Groups of three animals were treated with electric currents only-for 1, 3 and 7 days, respectively. In second experiment, electric currents and the orthodontic forces of about 80 gm were applied to the right maxillary canine, and the orthodontic forces only were applied to the left maxillary canine. 3 groups of three cats each were treated in this experiment-for 1, 3 and 7 days, respectively. Alveolar bone samples were obtained from sites of tension and compression as well as from contralateral sites. Bone samples were extracted by homogenization in $40\%$ ethanal. The supernatant partitioned twice with 2 volumes of petroleum ether to remove neutral lipids and the aqueous supernatant partitioned in ethyl acetate. After drying the solvent, $PGE_2$ was measured by radioimmunoassay technique. The obtained results were as follows. 1. Teeth treated with combined force and electricity moved faster than those treated with force alone. 2. Alveolar bone $PGE_2$ content of electric stimulation was increased at both electrodes. 3. Alveolar bone $PGE_2$ content of mechanical stimulation at compression sites was gradually increased at all time period. At tension site, $PGE_2$ content increased after 1 day of mechanical stimulation remained elevated at all time period. 4. Alveolar bone $PGE_2$ content of compression sites was increased more than that of tension sites from mechanical stimulation as well as electrical stimulation.

  • PDF

Effect of Vinyl Ethylene Carbonate on Electrochemical Characteristics for Activated Carbon/Li4Ti5O12 Capacitors (활성탄/리튬티탄산화물 커패시터의 전기화학적 특성에 미치는 비닐에틸렌카보네이트의 영향)

  • Kwon, Yong-Kab;Choi, Ho-Suk;Lee, Joong-Kee
    • Journal of the Korean Electrochemical Society
    • /
    • v.15 no.3
    • /
    • pp.190-197
    • /
    • 2012
  • We employed the vinyl ethylene carbonate (VEC) as an electrolyte additive and investigated the effect of the electrolyte additive on the electrochemical performance in hybrid capacitor. The activated carbon was adopted as cathode material, and the $Li_4Ti_5O_{12}$ oxide was used as anode material. The electrolyte was prepared with the $LiPF_6$ salt in the mixed solvent of ethylene carbonate (EC), dimethyl carbonate (DMC), and ethyl methyl carbonate(EMC). We evaluated the electrochemical performance of the hybrid capacitor with increasing the amount of the VEC electrolyte additive, which is known as the remover of oxygen functional group and the stabilizer of the electrode by reducing the surface of electrode, and obtained the superior performance data especially at the addition of the VEC electrolyte additive of around 0.7 vol%. On the contrary, the addition of the VEC more than 0.7 vol% in the electrolyte leads to the degradation in electrochemical performance of hybrid capacitor, suggesting the increase of the side reaction from the excessive VEC additive. X-ray photoelectron spectroscopy (XPS) revealed that the addition of the VEC suppressed the formation of LiF component, which is known as the insulator, on the surface of electrode. The optimized addition of VEC exhibited the improved capacity retention around 82.7% whereas the bare capacitors without VEC additive showed the 43.2% of capacity retention after 2500 cycling test.

The Effect of Microcurrent Stimulation on Expression of BMP-4 After Tibia Fracture in Rabbits (미세전류가 토끼 경골의 골절 후 BMP-4 발현에 미치는 영향)

  • Cho, Mi-Suk
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.3
    • /
    • pp.196-203
    • /
    • 2010
  • This study aimed to examine the effect of microcurrent stimulation on expression of Bone Morphogenetic Protein(BMP) 4 after tibia fracture in rabbits. The twenty four adult 6 month old New Zealand white rabbits weighting 2.5~3.5 ㎏ were used. Twenty four rabbits with tibia fracture were randomly divided into control and experimental groups. Each group was divided into four subgroups, based on the duration of the experiment (3, 7, 14, 28 days). The experimental groups received microcurrent stimulation of 20~25 ${\mu}A$ intensity with surface Ag-AgCl electrode (diameter 1cm, Biopac, U.S.A.) for 24 hours a day. Cathode of the microcurrent stimulator located on the tibia directly, anode of it did on the gastrocnemius muscle. After evaluation, the test results are as follows: Comparisons of immunohistochemical observation of BMP-4 in 7 days after tibial fracture show that there was shown to be a moderate positive reaction (++) on concentric circles of Harversian system and the interstitial lamella in the control group, while there was a very strong positive reaction () on concentric circles of Harversian system and interstitial lamellain the experimental group. These results suggest that applying non-invasive constant microcurrent stimulation on fractured bone is helpful to bone healing.

Effect of $Al^{3+}$ Dopant on the Electrochemical Characteristics Of Spinel-type $Li_{4}Ti_{5}O_{12}$ (스피넬형 $Li_{4}Ti_{5}O_{12}$ 음극물질의 $Al^{3+}$ 첨가에 의한 전기화학적 성능 변화)

  • Jeong, Choong-Hoon;Lee, Eui-Kyung;Bang, Jong-Min;Lee, Bong-Hee;Cho, Byung-Won;Na, Byung-Ki
    • Clean Technology
    • /
    • v.14 no.3
    • /
    • pp.171-175
    • /
    • 2008
  • The effect of the addition of $Al^{3+}$ dopant on the electrochemical characteristics of $Li_{4}Ti_{5}O_{12}$ was investigated. $Li_{4}Ti_{5}O_{12}$ is known as a 2ero-strain material, and $Li_{3.95}Al_{0.15}Ti_{4.9}O_{12}$ has been manufactured by solid-state reaction with high energy ball milling (HEBM). The samples were heated at 800, 900 and $1000^{\circ}C$ in electric furnace. The structural and surface structures were measured by XRD (X-ray diffraction) and SEM (scanning electron microscopy). Cut-off voltage of charge/discharge cycles was $1.0{\sim}3.0 V$ to investigate reversible capacity, cycle stability and plateau voltage. The reversible capacity of $Li_{3.95}Al_{0.15}Ti_{4.9}O_{12}$ was 138 mAh/g.

  • PDF

Effect of the Heat Treatment on the Mechanical Property and Corrosion Resistance of CU - 7Al - 2.5Si Alloy (Cu-7Al-2.5Si 합금의 기계적 및 내식특성에 미치는 열처리 효과)

  • Lee, Syung-Yul;Won, Jong-Pil;Park, Dong-Hyun;Moon, Kyung-Man;Lee, Myeong-Hoon;Jeong, Jin-A;Baek, Tae-Sil
    • Corrosion Science and Technology
    • /
    • v.13 no.1
    • /
    • pp.28-35
    • /
    • 2014
  • Recently, the fuel oil of diesel engines of marine ships has been increasingly changed to heavy oil of low quality as the oil price is getting higher and higher. Therefore, the spiral gear attached at the motor of the oil purifier which plays an important role to purify the heavy oil is also easy to expose at severe environmental condition due to the purification of the heavy oil in higher temperature. Thus, the material of the spiral gear requires a better mechanical strength, wear and corrosion resistance. In this study, the heat treatment(tempering) with various holding time at temperature of $500^{\circ}C$ was carried out to the alloy of Cu-7Al-2.5Si as centrifugal casting, and the properties of both hardness and corrosion resistance with and without heat treatment were investigated with observation of the microstructure and with electrochemical methods, such as measurement of corrosion potential, cathodic and anodic polarization curves, cyclic voltammogram, and a.c. impedance. in natural seawater solution. The ${\alpha}$, ${\beta}^{\prime}$ and ${\gamma}_2$ phases were observed in the material in spite of no heat treatment due to quenching effect of a spin mold. However, their phases, that is, ${\beta}^{\prime}$ and ${\gamma}_2$ phases decreased gradually with increasing the holding time at a constant temperature of $500^{\circ}C$. The hardness more or less decreased with heat treatment, however its corrosion resistance was improved with the heat treatment. Furthermore, the longer holding time, the better corrosion resistance. In addition, when the holding time was 48hrs, its corrosion current density showed the lowest value. The pattern of corroded surface was nearly similar to that of the pitting corrosion, and this morphology was greatly observed in the case of no heat treatment. It is considered that ${\gamma}_2$ phase at the grain boundary was corroded preferentially as an anode. However, the pattern of general corrosion exhibited increasingly due to decreasing the ${\gamma}_2$ phase with heat treatment. Consequently, it is suggested that the corrosion resistance of Cu-7Al-2.5Si alloy can be improved with the heat treatment as a holding time for 48 hrs at $500^{\circ}C$.