Chordae Tendineae Approximation Technique for Severe Tricuspid Regurgitation with Severe Leaflet Tethering Using a Totally Endoscopic Beating-Heart Strategy: A Case Report

  • Dong Hee Jang;Jae Suk Yoo
    • Journal of Chest Surgery
    • /
    • v.56 no.1
    • /
    • pp.56-58
    • /
    • 2023
  • Untreated severe tricuspid regurgitation (TR) is associated with poor outcomes. Functional TR occurs secondary to dilatation of the annulus and tethering of the leaflets. Ring annuloplasty alone can correct most cases, but is insufficient in cases of severe annular dilatation due to severe leaflet tethering. In such cases, a tricuspid edge-to-edge technique may be an option. However, stitching of the leaflet tips alone is likely to result in tearing of the leaflets. Approximation of the durable chordae tendineae is considered helpful for this problem. Herein, we present the case of a 39-year-old man who had undergone open-heart surgery for acute type A aortic dissection 13 months earlier. A right mini-thoracotomy approach with a beating-heart strategy was used, which did not require unnecessary pericardial adhesiolysis and dissection. This technique had the advantage of reducing the operation time and the risk of bleeding. To summarize, we present a case of tricuspid valve repair in a high-risk patient with severe leaflet tethering that was successfully managed using these methods.

Tricuspid Edge-to-Edge Repair Versus Tricuspid Valve Replacement for Severe Tricuspid Regurgitation

  • Jihoon Kim;Heemoon Lee;Ji-Hyun Jung;Jae Suk Yoo
    • Korean Circulation Journal
    • /
    • v.53 no.11
    • /
    • pp.775-786
    • /
    • 2023
  • Background and Objectives: Tricuspid valve (TV) repair techniques other than annuloplasty remain challenging and frequently end in tricuspid valve replacement (TVR) in complicated cases. However, the results of TVR are suboptimal compared with TV repair. This study aimed to evaluate the clinical effectiveness of TV edge-to-edge repair (E2E) compared to TVR for severe tricuspid regurgitation (TR). Methods: We retrospectively reviewed 230 patients with severe TR who underwent E2E (n=139) or TVR (n=91) from 2001 to 2020. Clinical and echocardiographic results were analyzed using inverse probability of treatment weighting analysis and propensity score matching. Results: The two groups showed no significant differences in early mortality and morbidities. During the mean follow-up of 106.2±68.8 months, late severe TR and TV reoperation rates were not significantly different between groups. E2E group, however, showed better outcomes in overall survival (p=0.023), freedom from significant tricuspid stenosis (TS) (trans-tricuspid pressure gradient ≥5 mmHg, p=0.021), and freedom from TV-related events (p<0.001). Matched analysis showed consistent results. Conclusions: E2E for severe TR presented more favorable clinical outcomes than TVR. Our study supports that E2E might be a valuable option in severe TR surgery, avoiding TVR.

Reconstructive Procedures Combined with or Without Prosthetic Valve Replacement for Cardiac Valvular Lesions (심장판막 질환 성형술에 대한 임상적 고찰)

  • Kim, Y.;Cho, B.K.;Hong, S.N.
    • Journal of Chest Surgery
    • /
    • v.9 no.2
    • /
    • pp.207-214
    • /
    • 1976
  • Operations for cardiac valvular disease has been progressed in various ways. Since 1949 when Lord Russel operated mitral stenosis by closed technique at Johns Hopkins Hospital then much progress has been achieved and that nowadays severely diseased cardiac valve has been replaced by prosthetic valve, which is almost ideal in hemodynamic aspect, but still it has many problems such as thromboembolism, destruction of red blood cell, pressure gradient, and disturbance of left ventricular function, so in case of delicate situations, valve replacement should be decided carefully. Besides prosthetic valve, there are some kinds of reconstructive procedures and these have been resulted in better prognosis than prosthetic valve replacement in selected cases. So, authors have reviewed 61 Cases of cardiac patients who have been operated reconstructive valvular surgery by cardiopulmonary bypass, at Yonsei University, from Jan. 1963 to Mar. 1976. Out of 61 cases, 9 patients were replaced by prosthetic valve and rest of the patients were operated upon in various reconstructive procedures such as commissurotomy, valvotomy, valvuloplasty, and annuloplasty. Twenty cases of congenital heart diseases with valvular lesion, which had been operated for valvular lesion were also included in this statistics. Out of 9 cases of prosthetic valvular replacement five cases of prosthetic valvular replacement was done combined with other reconstructive procedures after attempted valvuloplasty. Comparative prognosis of both procedures are somewhat variable by reporters, average 19% of mortality after reconstructive surgery and 38% of mortality after prosthetic valve replacement in long term results. Most common cause of death in postoperative period was low output syndrome in both cases. It seems that good preoperative evaluation and proper reconstructive surgery will afford good prognosis in selected cardiac valvular diseased patient.

  • PDF

Surgical Outcomes of Congenital Atrial Septal Defect Using da VinciTM Surgical Robot System

  • Kim, Ji Eon;Jung, Sung-Ho;Kim, Gwan Sic;Kim, Joon Bum;Choo, Suk Jung;Chung, Cheol Hyun;Lee, Jae Won
    • Journal of Chest Surgery
    • /
    • v.46 no.2
    • /
    • pp.93-97
    • /
    • 2013
  • Background: Minimally invasive cardiac surgery has emerged as an alternative to conventional open surgery. This report reviews our experience with atrial septal defect using the da VinciTM surgical robot system. Materials and Methods: This retrospective study included 50 consecutive patients who underwent atrial septal defect repair using the da VinciTM surgical robot system between October 2007 and May 2011. Among these, 13 patients (26%) were approached through a totally endoscopic approach and the others by mini-thoracotomy. Nineteen patients had concomitant procedures including tricuspid annuloplasty (n=10), mitral valvuloplasty (n=9), and maze procedure (n=4). The mean follow-up duration was $16.9{\pm}10.4$ months. Results: No remnant interatrial shunt was detected by intraoperative or postoperative echocardiography. The atrial septal defects were mainly repaired by Gore-Tex patch closure (80%). There was no operative mortality or serious surgical complications. The aortic cross clamping time and cardiopulmonary bypass time were $74.1{\pm}32.2$ and $157.6{\pm}49.7$ minutes, respectively. The postoperative hospital stay was $5.5{\pm}3.3$ days. Conclusion: The atrial septal defect repair with concomitant procedures like mitral valve repair or tricuspid valve repair using the da VinciTM system is a feasible method. In addition, in selected patients, complete port access can be helpful for better cosmetic results and less musculoskeletal injury.

Severe Tricuspid Insufficiency after Correction of Anomalous Origin of the Left Coronary Artery from the Pulmonary Artery(ALCAPA) (ALCAPA 교정후 발생한 심한 삼첨판 폐쇄부전)

  • 백만종;김웅한;오삼세;류재욱;공준혁
    • Journal of Chest Surgery
    • /
    • v.34 no.9
    • /
    • pp.724-728
    • /
    • 2001
  • We report a case of an 8 years and 11 month-old male patient who had developed severe tricuspid insufficiency(TI) after correction of anomalous origin of the left coronary artery from the pulmonary artery(ALCAPA). Transthoracic echocardiogram and coronary angiography confirmed ALCAPA, ischemic mitral regurgitation and trivial TI. He underwent direct reimplantation of the left coronary artery to the aortic root by using additional cannulation at the main pulmonary artery for arterial inflow and cardioplegia delivery to the left coronary artery. After the correction of ALCAPA, transesophageal echocardiogram(TEE) revealed good antegrade flow at the aortic implantation site of the left coronary artery and severe TI(Gr III-IV/IV). Cardiopulmonary bypass was reestablished and tricuspid valve was repaired with Kay-type annuloplasty, artificial chordae formation and chordal shortening plasty. The postrepair TEE revealed trivial to mild TI.

  • PDF

Clinical experience of open heart surgery -70 cases- (개심술 70예의 임상경험)

  • 조광현
    • Journal of Chest Surgery
    • /
    • v.19 no.4
    • /
    • pp.644-662
    • /
    • 1986
  • Seventy cases of open heart surgery were performed in the department of Thoracic and Cardiovascular Surgery, Pusan Paik Hospital, Inje College, from Oct. 1985 to Oct. 1986. And the results were summarized as follows. 1. Among the 70 cases, there were 48 cases of congenital heart anomalies and 22 cases of acquired rheumatic valvular heart diseases. Age range of the congenital patients was 7 months to 31 years with the mean age of 10 years, and the acquired patients was 18 to 62 years with the mean age of 40 years. 2. The heart-lung machine used for cardiopulmonary bypass was Sarns 7000, 5-head roller pump, and the number and type of oxygenators were 5 of membrane type and 65 of bubble type. For all cases GIK [glucose-insulin-potassium] solution was used as cardioplegic solution for myocardial protection during operation. 3. Among the 48 congenital anomalies, there were 12 cases of ASD group, 29 of VSD group, 3 of ECD, 3 of TOF and one of PDA + MR, and to all of which the appropriate radical operations were applied. 4. Among the 22 acquired valvular diseases, there were 11 cases of mitral valve diseases [MS; 4, MSr; 3, MRs; 4], 3 cases of aortic valve diseases [AR:1, ARs;1, ASr;1], 4 cases of double valve diseases [MRs+TR; 3, MRs+ARs; 1] and 4 cases of triple valve diseases [MSr+ASr+TR; 3, MSr+Ar+TR; 1]. To all the diseased mitral and aortic valves, artificial valve replacement was applied except one [As], in which valve plication was applied. And to all the diseased tricuspid valve, DeVega annuloplasty was applied. 5. The number of replaced artificial valves were 29 in 25 patients [congenital; 3, acquire; 22]. In MVR, 6 of mechanical valves [St. Jude Medical valve; 6] and 15 of tissue valves [Carpentier-Edward valve; 11, lonescu-Shiley valve; 4] were used. In AVR, 6 of mechanical valves [St. Jude Medical valve; 6] and 2 of tissue valves [Carpentier-Edward valve; 2] were used. 6. Postoperative complications were occurred in 12 cases. Among them 11 cases were recovered with intensive cares, but one patient [VSD + Fistula of Valsalva sinus] was expired with low cardiac out put syndrome.

  • PDF

Open Heart Surgery 110 Cases in One Year(1987) (연간 (1987년) 개심술 110례에 대한 검토)

  • 조광현
    • Journal of Chest Surgery
    • /
    • v.21 no.2
    • /
    • pp.351-365
    • /
    • 1988
  • During one year[1987], 110 cases of open heart surgeries were performed in the department of Thoracic and Cardiovascular Surgery, Pusan Paik Hospital, Inje Medical College. And the results were summarized as follows. 1. Among the 110 cases, there were 77 cases of congenital heart diseases and 33 cases of acquired heart diseases. Age range of the congenital patients was 8 months to 30 years with the mean age of 8 years, and acquired patients was 16 to 56 years with the mean age was 32 years. 2. The heart lung machine used for cardiopulmonary bypass was Sarns 7000, 5-head roller pump, and the number and type of oxygenators were 50 of membrane type and 60 of bubble type. For all cases GIK[glucose-insulin-potassium] solution was used as cardioplegic solution for myocardial protection during operation. 3. Among the 77 congenital anomalies, there were 67 cases of acyanotic patients[ASD: 12, VSD: 50, PS: 1, AP window: 1, Gerbode defect: 1, ECD: 2] and 10 cases of cyanotic patients[TOF: 10], and to all of which the appropriate radical operations were applied. 4. Among the 33 acquired diseases, there were one case of left atrial myxoma, one of annuloaortic ectasia, 20 of mitral valve diseases[MS: 2, MSr: 8, MR: 2, MRs: 8], 9 of double valve diseases[MRs+AR: 1, MRs+ARs: 2, MRs+TR: 1, MSr+TR: 3, MSr+ASr: 1, MSr+ARs: 1], 2 of triple valve diseases[MSr+AR+TR: 1, MSr+ASr+TR: 1]. The left atrial myxoma was removed well with right atriotomy and atrial septal approach. And to the annuloaortic ectasia, Bentall operation was applied with good result. Mitral valve replacement[MVR] was applied to 20 cases of mitral valve diseases, double valve replacement[MVR+AVR] was applied to 6 cases of double valve diseases, MVR & tricuspid annuloplasty[TVA] was applied to 3 cases of mitral 5. The number of replaced valve were 39 in 31 cases. In MVR, 5 of mechanical valves[St. Jude Medical Valve] and 26 of tissue valves[Carpentier-Edward valve] were used. In AVR, 3 of mechanical valves and 5 of tissue valves were used. 6. Postoperative complications were occurred in 23 cases, and among them 21 cases were recovered with intensive cares, but 2 cases were expired[mortality: 1.8%].

  • PDF

Midterm results of aortic root enlargement with AVR in patients with narrow aortic root and AS (협소 대동맥 판륜을 가진 환자에서의 대동맥치환술시 판륜 확장술의 중기 성적)

  • 박광훈;김하늘루;최강주;이양행;황윤호;조광현
    • Journal of Chest Surgery
    • /
    • v.33 no.4
    • /
    • pp.285-289
    • /
    • 2000
  • Background: For AVR using conventional prosthetic valves in adult patients with a narrow aortic root, aortic root enlargement is necessary to reduce postoperative pressure gradient across the aortic valve (ΔP). An evaluation of early and mid-term results of aortic root enlargement with AVR and echocardiographic follow up of ΔP and left ventricular function was performed. Method: From Aug. 1991 to Feb. 1998, eighteen patients aged 17 to 59 years(mean, 38$\pm$12 years) underwent Manouguian procedure with AVR. Aortic annular circumstance was enlarged 10.0mm to 18.0mm(mean, 12.6$\pm$6.3mm). Eight patients(44.0%) had NYHA class III status before operation, and seven cases of them underwent concomitant MVR. Valve pathology was ASr in 6 cases, AS in 4 cases, nd ASr+MSr in 8 cases. Replaced valve size was 21mm in 8 cases and 23 mm in 10 cases, and St. Jude Medical mechanical valve was used in 10 cases and Carbomedics in 8 cases. Result: Follow-up duration was 6 to 57 months (mean, 26$\pm$18 months), and total follow-up was 287 patient-year. There were one hospital death and one late death, therefore, actuarial survival rate was 85.7% at 56 months. Peak ΔP wad decreased significantly at postoperative mid-term period as 13$\pm$5mmHg, compared with thepreoperative one (42$\pm$8mmHg) (p<0.01). LVM(gm/$m^2$) was also diminished as 35.8%(115$\pm$36gm/$m^2$)at postoperative mid-term period, compared with preoperative one (179$\pm$56gm/$m^2$)(p<0.05). Conclusion: There were no specific complications related to the procedure. And we could have adequate enlargement of aortic annulus to suitable prosthetic valve that have no effect of patient-prosthese mismatch.

  • PDF

Mitral Valve Reconstruction (승모판 재건술)

  • 이현우
    • Journal of Chest Surgery
    • /
    • v.28 no.12
    • /
    • pp.1107-1112
    • /
    • 1995
  • Between December 1993 and December 1994, fifty-eight percent of the mitral valve patients[33/57 had undergone mitral valve repair. Their mean age was 49[SD-16 years[range 11 - 75 and they were consisted with 15 males and 18 females. The causes of mitral disease in 33 patients were classified as follows: 19 cases[58% were degenerative, 9[27% were rheumatic, 3[9% were congenital and 2[6% were infectious. Carpentier`s functional classification was consisted with Class I 4 cases[12% , II 25 [76% and III 4 [12% . Surgical techniques included prosthetic annuloplasty in 32 cases[97% , leaflet resection in 16[48% , chorda shortening in 13[39% , chorda transfer in 9[27% , new chorda formation in 7[21% , commissurotomy in 7[21% , leaflet mobilization in 4[12% , chorda resection in 3[9% , papillary muscle splitting in 2[6% , cleft repair in 2[6% , leaflet patching in 1[3% and vegetation removal in 1[3% . Average number of mitral anatomical lesions per patient was 3.3 and We used average 3.0 procedures upon mitral valve apparatus per patient. Intraoperative transesophageal echocardiography was carried out in 27 patients[82% for providing an immediate and accurate assessment of the adequacy of the reconstruction before closure of the chest. Operative mortality was absent. The mean functional class[NYHA was 2.87 preoperative and improved to 1.03 postoperatively. Postoperative Doppler echocardiography showed much improvement from grade II MR[5 , grade III[5 , grade IV[21 to no MR[26 , only trace MR[3 , grade III MR[2 . Postoperative mean mitral valve area was 2.4$\pm$0.6cm2[range 1.5 - 4.0 . We conclude that cautiously evaluated mitral valve reconstruction is stable and predictable operation with minimal postoperative left ventricular dysfunction.

  • PDF

Open heart surgery of Ebstein's anomaly -Report of 12 cases- (Ebstein 기형에 대한 개심술 -12례 보고-)

  • Ahn, Hyuk;Park, Yee-Tae;Rho, Joon-Ryang;Suh, Kyung-Phill;Lee, Yung-Kyoon
    • Journal of Chest Surgery
    • /
    • v.16 no.2
    • /
    • pp.157-163
    • /
    • 1983
  • Ebstein's anomaly is a rare congenital cardiac malformation oand the ideal surgical correction seems controversial at present, and some problems are left unsolved in the surgical correction of this anomaly. Between June 1978 and June 1982, 12 patients with Ebsteins' anomaly underwent corrective open heart surgery at Seoul National University Hospital. Except for one patient, who had no ASD, all had a huge right atrium, secundum type ASD, and definite atrialized right ventricle. Typically, displaced tricuspid valve leaflets were found in all cases, but the degree of displacement and deformity were variable. In the point of NYHA functional classification, five were in class II, six were in class III, and one was in class IV. Ten patients were operated on by tricuspid valve replacement and pication. Two patients were operated on only by plication and annuloplasty techniques, and in all cases, ASD was closed. Postoperatively, four patients suffered from complete A-V block, and two of them died immediately. The remaining two patients took pacemaker generator implantation with good results. The other eight patients were in good condition. Tricuspid valve replacement using tissue valve and plication of the atrialized rght ventricle seems to be a good method of surgical correction for Ebstein's anomaly.

  • PDF