• 제목/요약/키워드: Annual electricity generation

검색결과 54건 처리시간 0.025초

태양광발전시스템 국내 지역별 발전특성 분석 (Analysis of Power Generation Characteristics of a Photovoltaic System in Korea)

  • 이현승;김법전;신우철
    • 한국태양에너지학회 논문집
    • /
    • 제39권2호
    • /
    • pp.33-43
    • /
    • 2019
  • In this study, reflecting long-term climate characteristics, we analyzed electricity generation and generation characteristics of 3kWp PV system, which was semi-integrated with air duct behind. Using PVsyst as a simulation analysis tool, we inputted "National reference standard weather data" of 16 regions as a typical climatic data. The result is summarized as follows: First, the national average annual electricity generation was 1,312 kWh/kWp (StDev, ${\sigma}=71$). It was most abundant in Mokpo with 1,434 kWh/kWp, which was average 21% greater than the lowest with 1,165 kWh/kWp in Seoul and 1,197 kWh/kWp in Jeju. National average daily generating time based on STC was 3.6 hours (${\sigma}=0.43$), and that of Mokpo and Seoul was 3.9 and 3.2 hours respectively. Second, Jeju showed the great difference of annual monthly generation by month (annual average = 99.7 kWh/kWp, ${\sigma}=25.5$), while Jinju showed the smallest difference (annual average = 115.5 kWh/kWp, ${\sigma}=10.6$). Generation in Jeju was at the largest in April with 132.2 kWh/kWp, which was 2.3 times greater than the lowest 55.2 kWh/kWp in January. However, generation in Jinju was at the largest in March with 129.3 kWh/kWp, which was only 1.3 times greater than the lowest 101.1 kWh/kWp in June. Third, the annual average PR was the highest in Incheon with 85.8% and the lowest in Jeju with 83.2%. PR of Mokpo was 84.3%, which was lower than that of national average.

주택지붕용 2kWp BIPV시스템의 성능 실험 및 전기 부하 감당에 관한 연구 (The Performance and Energy Saving Effect of a 2kWp Roof-Integrated Photovoltaic System)

  • 이강록;오명택;박경은;김진희;김준태
    • 한국태양에너지학회 논문집
    • /
    • 제26권1호
    • /
    • pp.13-19
    • /
    • 2006
  • The efficiency of building-integrated photovoltaic(BIPV) system is mainly determined by solar radiation and the temperature of PV modules. The performance of BIPV systems is reported to be different from that of conventional PV systems installed in the open-air. This paper presents the relationship of solar radiation and electricity generation from a 2kWp roof-integrated PV system that is applied as building elements on an experimental house, and the energy saving effect of the BIPV system for a typical house. For the performance evaluation of the BIPV system, it produced a regression equation with measured data for winter days. The regression equation showed that a comparison of the measured electricity generation and the predicted electricity generation of the BIPV system were meaningful. It showed that an annual electricity generation of the system appeared to cover around 52% of an annual electricity consumption of a typical domestic house with the floor area of $96m^2$.

지리정보시스템을 이용한 소수력자원 분포 연구 (A Study on Distribution of Small Hydropower Resources Using GIS)

  • 박완순;이철형
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 추계학술대회 초록집
    • /
    • pp.203-203
    • /
    • 2010
  • Small hydropower is one of the many types of new and renewable energy, which South Korea is planning to develop, as the country is abundant in endowed resources. In order to fully utilize small hydropower resources, there is a need for greater precision in quantifying small hydropower resources and establish an environment in which energy sources can be discovered using the small hydropower geographic information system. This study has given greater precision to calculating annual electricity generation and installed capacity of small hydropower plants of 117 medium basins by inquiring into average annual rainfall, basin area and runoff coefficient, which is anticipated to promote small hydropower resources utilization. Small hydropower geographic information system was also established by additionally providing base information on quantified small hydropower resources and analysis function and small hydropower generator status, rivers, basin, rainfall gauging station, water level gauging station etc.. Established system of GIS small hydropower energy can be used gather basic information for positive applications of small hydropower energy nationwide.

  • PDF

발전용 연료전지 형식에 따른 균등화 발전비용 분석 (Analysis of Levelized Cost of Electricity for Type of Stationary Fuel Cells)

  • 이동근;이스라엘;배용균;김영상;안국영;이선엽
    • 한국수소및신에너지학회논문집
    • /
    • 제33권6호
    • /
    • pp.643-659
    • /
    • 2022
  • For the economic analysis of fuel cells, levelized cost of electricity was calculated according to the type, capacity, and annual production of the fuel cells. The cost of every component was calculated through the system component breakdown. The direct cost of the system included stack cost, component cost, assembly, test, and conditioning cost, and profit markup cost were added. The effect of capacity and annual production was analyzed by fuel cell type. Sensitivity analysis was performed according to stack life, capital cost, project period, and fuel cost. As a result, it was derived how much the economic efficiency of the fuel cell improves as the capacity increases and the annual production increases.

전기충전소의 경제적 운영을 위한 독립발전 시스템 설계 (Independent Generation System Design for the Economic Management of Electrical Charging Stations)

  • 서진규;김규호;이상봉
    • 전기학회논문지
    • /
    • 제64권2호
    • /
    • pp.222-227
    • /
    • 2015
  • This paper presents the optimal energy generation systems for economical EVs(Electric Vehicles) charging stations located in an island area. The system includes grid electricity, diesel generator and renewable energy sources of wind turbines and PV(Photovoltaic) panels. The independent generation system is designed with data resources such as annual average wind speed, solar radiation and the grid electricity price by calculating system cost under different structures. This sensitive analysis on the varying data resources allows for the configuration of the most economical generation system for charging stations by comparing initial capital, operating cost, NPC(Net Present Cost) and COE(Cost of Energy). Depending on the increase of the grid cost, the NPC variation of the most economical system which includes renewable energy generations and grid electricity can be smaller than those of other generation systems.

Energy Forecasting Information System of Optimal Electricity Generation using Fuzzy-based RERNN with GPC

  • Elumalaivasan Poongavanam;Padmanathan Kasinathan;Karunanithi Kandasamy;S. P. Raja
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제17권10호
    • /
    • pp.2701-2717
    • /
    • 2023
  • In this paper, a hybrid fuzzy-based method is suggested for determining India's best system for power generation. This suggested approach was created using a fuzzy-based combination of the Giza Pyramids Construction (GPC) and Recalling-Enhanced Recurrent Neural Network (RERNN). GPC is a meta-heuristic algorithm that deals with solutions for many groups of problems, whereas RERNN has selective memory properties. The evaluation of the current load requirements and production profile information system is the main objective of the suggested method. The Central Electricity Authority database, the Indian National Load Dispatch Centre, regional load dispatching centers, and annual reports of India were some of the sources used to compile the data regarding profiles of electricity loads, capacity factors, power plant generation, and transmission limits. The RERNN approach makes advantage of the ability to analyze the ideal power generation from energy data, however the optimization of RERNN factor necessitates the employment of a GPC technique. The proposed method was tested using MATLAB, and the findings indicate that it is effective in terms of accuracy, feasibility, and computing efficiency. The suggested hybrid system outperformed conventional models, achieving the top result of 93% accuracy with a shorter computation time of 6814 seconds.

An Investigation Into the Impact of Limiting Carbon Emissions on the Korean Power System and the Electricity Market

  • Kim, Changseob;Park, Hyeongon
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권3호
    • /
    • pp.1038-1045
    • /
    • 2017
  • To address mounting concerns over global warming, the Paris Agreement was reached in December 2015, which aims to limit the increase in global average temperature. South Korea has set a highly ambitious target to reduce emissions and submitted an Intended Nationally Determined Contribution (INDC). Based on the INDC, we investigated the impact of limiting carbon emissions on the power system and the electricity market in Korea. Through detailed simulations on assumed plausible scenarios, this work highlights a) the effects of different carbon emission targets on the annual carbon emission volumes, generation costs, and carbon price; b) the generation mix changes induced by carbon emission limits; and c) the difference in system marginal price and payments for generator owners that carbon emission constraint creates in electricity markets under three different pricing rules.

태양광발전시스템의 장기운전에 의한 성능변화 분석 (Performance Analysis of long term operation for photovoltaic system)

  • 김의환;김정삼
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 춘계학술대회 초록집
    • /
    • pp.110.1-110.1
    • /
    • 2011
  • This study analyzed the performance of long term operation photovoltaic system The 50 kWp grid connected photovoltaic system which was installed at KEPRI site in 1999 has been operated more than 12 years. In order to acquire long term operation characteristics of medium size photovoltaic system, the operation test data related on power generation electricity and capacity factor of 50 kWp system, which have been collected since 1999, were analysed. From the analysing results, 57.7 MWh in annual power generation electricity of 50 kWp photovoltaic system in 1999 has been decreased 49.1 MWh in 2005 and reached 38.0 MWh in 2010. In addition to, the capacity factor of 50 kWp photovoltaic system also showed 13.2 % in 1999, 11.2% in 2005 and finally reached 8.8% in 2011. The operation test data showed a trend of decreasing of generation electricity and capacity factor during the 12 years operation time and we guessed that was caused by solar cell performance degradation and decreasing of PCS system efficiency.

  • PDF

중규모 태양광발전시스템 장기 실증운전 평가 (The long-term operating evaluation of the grid connected photovoltaic system)

  • 김의환;안교상;임희천
    • 한국태양에너지학회 논문집
    • /
    • 제29권5호
    • /
    • pp.14-19
    • /
    • 2009
  • The 50 kWp grid connected photovoltaic system which was installed at KEPRI site in 1999 has been operated more than 10 years. In order to acquire long term operation characteristics of medium size photovoltaic system, the operation test data related on power generation electricity and capacity factor of 50 kWp system, which have been collected since 1999, were analysed. From the analysing results, 57.7 MWh in annual power generation electricity of 50 kWp photovoltaic system in 1999 has been decreased 49.1 MWh in 2005 and reached 41.9 MWh in 2008. In addition to, the capacity factor of 50 kWp photovoltaic system also showed 13.2 % in 1999, 11.2% in 2005 and finally reached 9.6% in 2008. The operation test data showed a trend of decreasing of generation electricity and capacity factor during the 10 years operation time and we guessed that was caused by solar cell performance degradation and decreasing of PCS system efficiency.

어린이집의 넷 에너지 제로화 구현에 관한 사례분석 (A Feasibility Case Study on Net-Zero Energy Daycare Center)

  • 김지현;임희원;신우철
    • 대한건축학회논문집:구조계
    • /
    • 제35권4호
    • /
    • pp.185-192
    • /
    • 2019
  • In this study, we, through case studies, formulated a method to implement net-zero energy daycare center at the current insulation and technology level, and calculated its energy expense. The reference model was a medium sized daycare center whose number of children was 99. We analyzed the energy consumption status for the reference model and developed TRNSYS simulation analytical model to realize net-zero energy . We assumed the reference model to be "All Electric Building" where all energy including cooking is supplied by electricity. The result is summarized as follows: First, the annual electricity consumption of daycare center was 53,291kWh. Plug load occupied the largest share of 48% followed by lighting, 10%, cooling, 9%, cooking, 9%, heating, 8%, hot water, 5% and ventilation, 2%. Second, the photovoltaic installation capacity to realize net-zero energy was 40.32kWp and its annual generation was 53,402kWh. Third, the annual energy expense(electricity bill) by realizing net-zero energy was 2,620,390won.