• Title/Summary/Keyword: Annual Volume

Search Result 360, Processing Time 0.023 seconds

Stand Yield Table and Commercial Timber Volume of Eucalyptus Pellita and Acacia Mangium Plantations in Indonesia (인도네시아 유칼립투스 및 아카시아 조림지의 임분수확표 및 이용가능 목재생산량 추정)

  • Son, Yeong-Mo;Kim, Hoon;Lee, Ho-Young;Kim, Cheol-Min;Kim, Cheol-Sang;Kim, Jae-Weon;Joo, Rin-Won;Lee, Kyeong-Hak
    • Journal of Korean Society of Forest Science
    • /
    • v.99 no.1
    • /
    • pp.9-15
    • /
    • 2010
  • This study was conducted to develop a stand growth model and a stand yield table for Eucalyptus pellita and Acacia mangium plantations in Kalimantan, Indonesia. To develop a stand growth model, Weibull robability density function, a diameter class model, was applied in this study. In the development of stand growth model by site index and stand age, a hierarchy is generally required - estimation, recovery and prediction of the diameter class model. A number of grow equations were also involved in each process to estimate diameter, height, basal area, minimum or maximum diameter. To examine whether the grow equations are adequate for Eucalyptus pellita or Acacia mangium plantations, a fitness index was analyzed for each equation. The results showed that fitness indices were ranged from 65 to 89% for Eucalyptus pellita plantations and from 72 to 95% for Acacia mangium plantations. As being highly adequate for the plantations, a stand yield table was developed based on the resulted growth model, and applied to estimate the stand growth with midium site index for 10-year period. The highest annual stand growth of Eucalyptus pellita plantations was estimated to be 21.25 $m^3$/ha, while that of Acacia mangium plantations was 27.5 $m^3$/ha. In terms of annual stand growth, Acacia mangium plantations appeared to be more beneficial than Eucalyptus pellita plantations. Also, to estimate commercial timber volume available from the plantations, an assumption that a log would be cut by 2.7 m in length and the rest of the log would be cut by 1.5m was involved. The commercial timber volume available from Eucalyptus pellita plantations was 68.0 $m^3$/ha, 33% from the total stand volume, 203.2 $m^3$/ha. Also 96.7 $m^3$/ha of commercial timbers were available from Acacia mangium plantations, which was 42% from the 232.9 $m^3$/ha in total. Presenting a good information about the stand growth in Eucalyptus pellita and Acacia mangium plantations, this study might be useful for whom proceeds or considers an abroad plantation for merchantable timber production or carbon credit in tropical regions.

A Study on Performance Evaluation of Various Kriging Models for Estimating AADT (연평균 일교통량 산정을 위한 다양한 크리깅 방법의 성능 평가에 대한 연구)

  • Ha, Jung Ah;Oh, Sei-Chang;Heo, Tae-Young
    • Journal of Korean Society of Transportation
    • /
    • v.32 no.4
    • /
    • pp.380-388
    • /
    • 2014
  • Annual average daily traffic(AADT) serves as important basic data in the transportation sector. AADT is used as design traffic which is the basic traffic volume in transportation planning. Despite of its importance, at most locations, AADT is estimated using short term traffic counts. An accurate AADT is calculated through permanent traffic counts at limited locations. This study dealt with estimating AADT using various models considering both the spatial correlation and time series data. Kriging models which are commonly used spatial statistics methods were applied and compared with each model. Additionally the External Universal kriging model, which includes explanatory variables, was used to assure accuracy of AADT estimation. For evaluation of various kriging methods, AADT estimation error, proposed using national highway permanent traffic count data, was analyzed and their performances were compared. The result shows the accuracy enhancement of the AADT estimation.

Storm-Water CSOs for Reservoir System Designs in Urban Area (도시유역 저류형 시스템 설계를 위한 CSOs 산정)

  • Jo, Deok-Jun;Kim, Myoung-Su;Lee, Jung-Ho;Park, Moo-Jong;Kim, Joong-Hoon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2005.05b
    • /
    • pp.1199-1203
    • /
    • 2005
  • Combined sewer overflows(CSOs) are themselves a significant source of water pollution. Therefore, the control of urban drainage for CSOs reduction and receiving water quality protection is needed. Examples in combined sewer systems include downstream storage facilities that detain runoff during periods of high flow and allow the detained water to be conveyed by an interceptor sewer to a centralized treatment plant during periods of low flow. The design of such facilities as stormwater detention storage is highly dependant on the temporal variability of storage capacity available(which is influenced by the duration of interevent dry periods) as well as the infiltration capacity of soil and recovery of depression storage. As a result, a contiunous approach is required to adequately size such facilities. This study for the continuous long-term analysis of urban dranage system used analytical Probabilistic model based on derived probability distribution theory. As an alternative to the modeling of urban drainage system for planning or screening level analysis of runoff control alternatives, this model have evolved that offer much ease and flexibility in terms of computation while considering long-term meteorology. This study presented rainfall and runoff characteristics or the subject area using analytical Probabilistic model. Runoff characteristics manifasted the unique characteristics of the subject area with the infiltration capacity of soil and recovery of depression storage and was examined appropriately by sensitivity analysis. This study presented the average annual COSs and number of COSs when the interceptor capacity is in the range 3xDWF(dry weather flow). Also, calculated the average annual mass of pollutant lost in CSOs using Event Mean Concentration. Finally, this study presented a dicision of storage volume for CSOs reduction and water quality protection.

  • PDF

A Study of Heavy Metal Pollutants in the Respirable Dust in Seoul Area (호흡성분진중의 중금속 오염도에 관한 조사연구)

  • Lim, Young-Wook;Chung, Young
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.5 no.1
    • /
    • pp.68-78
    • /
    • 1989
  • The heavy metal of suspended particulates with human health has long been studied in environmental interest concerned. This study was intended to identify harmful heavy metals of the ambient air borne dusts which were related with the respirable sizes in the aerodynamics. Two sampling sites were selected comparatively; one was in the Shinchon area, which is the commercial district with heavy traffic and the other site was in the Bulgwang area which is residential area. The supended particulates were sampled by high volume air sample with 6 cascade impactor stages. The heavy metals in terms of As, Cd, Cr, Cu, Fe, Hg, Mn, Ni, Pb, Se, V and Zn were determined by stomic absorption spectrometry or inductively coupled plasma emission spectrometry. The samples weretaken bimothly for seven consecutive days from May 1987 to March 1988. The annual average concentration of the respirable suspended dust of which diameter is less than 10$\mum$ was 152.59 $\mug/m^3$ of the Shinchon air samples; the respirable dust was equivalent to approximately 85% of the total suspended particulates. The annual average concentration of the respirable suspended dust of the Bulgwang air samples was 112.56 $\mug/m^3$; that was approximately 86% of the total suspended particulates. The concentration of heavy metals was investigated in relation to the particle size. The concentration of Cr, Fe, Mn and V were tended to be much more in the coarse particles than in the fine particles. Cd and Pb in the fine particles were more than in the coarse particles. In the partial correlation coefficients; in the Shinchon area, high correlations among Fe, Se and Mn were determined; it is assumed that those sources would be originated from coal, gasolineand diesel. In Bulgwang area, would be high correlation among Fe, Se, Hg and Mn considered to be originated from coal, Bunker-C and heavy oil as well. From the above results, the hazardous heavy merals in air should be measured and controlled in originally their sources.

  • PDF

Characteristics of Nonpoint Source Pollutant Loads from Forest watershed with Various Water Quality Sampling Frequencies (수질샘플빈도에 따른 산림유역의 비점원오염부하특성)

  • Shin, Min-Hwan;Shi, Yong-Chul;Heo, Sung-Gu;Lim, Kyoung-Jae;Choi, Joong-Dae
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.50 no.2
    • /
    • pp.65-71
    • /
    • 2008
  • A monsoon season monitoring data from June to September, 2005 of a small forested watershed located at the upstream of the North Han River system in Korea was conducted to analyze the flow variations, the NPS pollutant concentrations, and the pollution load characteristics with respect to sampling frequencies. During the 4-month period, 1,423 mm or 79.2% of annual rainfall(1,797 mm) were occurred and more than 77%, 54% and 68% of annual T-N, $NO_3$-N and T-P loads discharged. Flow rate was continuously measured with automatic velocity and water level meters and 58 water quality samples were taken and analyzed. It was analyzed that the flow volume by random measurement varied very widely and ranged from 79% to 218% of that of continuous measurement. It was recommended that flow measurement of small forested watersheds should be continuously measured with automated flow meters to precisely measure flow rates. Flow-weighted mean concentrations of T-N, $NO_3$-N and T-P during the period were 2.114 mg/L, 0.836 mg/L, and 0.136 mg/L, respectively. T-N, $NO_3$-N and T-P loads were sensitive to the number of samples. And it was analyzed that in order to measure the pollution load within the error of 10% to the true load, the rate of sampling frequency should be higher than 89.7% of the sample numbers that were required to compute the true pollution load. If it is compared to selected foreign research results, about 10 water samples for each rainfall event were needed to compute the pollution load within 10% error. It is unlikely in Korea and recommended that thorough NPS pollution monitoring studies are required to develop the standard monitoring procedures for reliable NPS pollution quantification.

A Estimation on the Annual Growth in Diameter of Pitch Pine (Pinus rigida Mill.) Stand (리기다 소나무림(林)의 직경연년성장량(直徑連年成長量) 추정(推定))

  • Lee, Yeo Ha
    • Journal of Korean Society of Forest Science
    • /
    • v.17 no.1
    • /
    • pp.23-28
    • /
    • 1973
  • In this survey, to estimate volume growth of pitch pine (Pinus rigida Mill) stand, diameter growth was estimated. Among 223 sample trees, the number of rejected trees was 12, about 5 percent of total sample trees. The stand showed uniform growth and rejected trees included insect-damaged trees. Compared with reports made on forest classification basis, pitch pine a single species showed faster growth. Minimum, average and maximum value of D.B.H and mean annual diameter growth, of 16 year old pitch pine stand, were as follow. The correlation of each factors estimated by 9590 of confidence interval is shown in the table of correlation as bellow.

  • PDF

Evaluation of Rainwater Utilization for Miscellaneous Water Demands in Different Types of Buildings Using Geographic Information System

  • Kim, Jinyoung;An, Kyoungjin;Furumai, Hiroaki
    • Environmental Engineering Research
    • /
    • v.18 no.2
    • /
    • pp.85-90
    • /
    • 2013
  • This study is an attempt to quantify rainwater utilization and miscellaneous water demand in Tokyo's 23 special wards, the core of the urban area in Tokyo, Japan, in order to elucidate the potential of further rainwater utilization. The rainwater utilization for miscellaneous appropriate water demands, including toilet flushing, air conditioning, and garden irrigation, were calculated for six different types of building: residential house, office, department store, supermarket, restaurant, and accommodation. Miscellaneous water demands in these different types of building were expressed in terms of equivalent rainfall of 767, 1,133, 3,318, 1,887, 16,574, and 2,227 (mm/yr), respectively, compared with 1,528 mm of Tokyo's average annual precipitation. Building types, numbers and its height were considered in this study area using geographic information system data to quantify miscellaneous water demands and the amount of rainwater utilization in each ward. Area precipitation-demand ratio was used to measure rainwater utilization potential for miscellaneous water demands. Office and commercial areas, such as Chiyoda ward, showed rainwater utilization potentials of <0.3, which was relatively low compared to those wards where many residential houses are located. This is attributed to the relatively high miscellaneous water demand. In light of rainwater utilization based on building level, the introduction of rainwater storage mechanisms with a storage depth of 50 mm for six different types of buildings was considered, and calculated as rainfall of 573, 679, 819, 766, 930, and 787 (mm), respectively. Total rainwater utilization using such storage facilities in each building from 23 wards resulted in the retention of 102,760,000 $m^3$ of water for use in miscellaneous applications annually, and this volume corresponded to 26.3% of annual miscellaneous water demand.

Pollutant Load Characteristics from a Small Mountainous Agricultural Watershed in the North Han River Basin (북한강 중류 산간농업 소하천에서의 오염부하특성분석)

  • Shin, Yong-Chul;Choi, Joong-Dae;Lim, Kyoung-Jae;Shim, Hyeok-Ho;Lyou, Chang-Won;Yang, Jae E.;Yoo, Kyung-Yoal
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.47 no.6
    • /
    • pp.83-92
    • /
    • 2005
  • Natural environment of the Wolgokri stream watershed, located in Chuncheon, Gangwon province, Korea, has been well preserved as a traditional agricultural watershed. To analyze characteristics of NPS pollution generated from an mountainous agricultural watershed, the flow and water qualities of the study watershed were monitored and were analyzed to estimate pollution loads. Annual runoff volume ratio was $70.4\%$. Concentrations of T-N, T-p, COD, and TOC were higher when monthly rainfall was between $0\~30mm$ than those when monthly rainfall was between $30\~70mm$. However, the concentrations varied considerably when monthly rainfall was higher than 100mm. The flow weighted mean concentrations(mg/L) of BOD, COD, TOC, $NO_3-N$, T-N, T-P and SS were 1.96, 2.72, 3.32, 1.41, 4.70, 0.187 and 13.36, respectively. The BOD, SS, T-N and T-P loads of July, 2004 were $48\%,\;17\%,\;51\%\;and\;32\%$ of annual load, respectively. The BOD, COD, TOC, $NO_3-N$, T-N, T-p, and SS loads (kg/ha) from Mar. 2004 to Apr. 2005 were 19.09, 26.55, 32.39, 13.85, 45.92, 1.887 and 130.18, respectively. The highest concentrations of BOD, NO3-N, T-N, T-p, SS, COD and TOC were found before the flow reached the peak runoff, possibly due to the first flushing effect. Generally, pollution loads of the Wolgokri watershed were not that significant. Phosphorus load, however, was higher enough to cause eutrophication in the receiving water body It was recommended that best management practices need to be implemented to reduce phosphorus sources.

Estimation of Storage Capacity for CSOs Storage System in Urban Area (도시유역 CSOs 처리를 위한 저류형시스템 설계용량 산정)

  • Jo, Deok Jun;Lee, Jung Ho;Kim, Myoung Su;Kim, Joong Hoon;Park, Moo Jong
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.4
    • /
    • pp.490-497
    • /
    • 2007
  • A Combined sewer overflows (CSOs) are themselves a significant source of water pollution. Therefore, the control of urban drainage for CSOs reduction and receiving water quality protection is needed. Examples in combined sewer systems include downstream storage facilities that detain runoff during periods of high flow and allow the detained water to be conveyed by an interceptor sewer to a centralized treatment plant during periods of low flow. The design of such facilities as stormwater detention storage is highly dependant on the temporal variability of storage capacity available (which is influenced by the duration of interevent dry periods) as well as the infiltration capacity of soil and recovery of depression storage. As a result, a continuous approach is required to adequately size such facilities. This study for the continuous long-term analysis of urban drainage system used analytical probabilistic model based on derived probability distribution theory. As an alternative to the modeling of urban drainage system for planning or screening level analysis of runoff control alternatives, this model have evolved that offer much ease and flexibility in terms of computation while considering long-term meteorology. This study presented rainfall and runoff characteristics of the subject area using analytical probabilistic model. This study presented the average annual COSs and number of COSs when the interceptor capacity is in the range $3{\times}DWF$ (dry weather flow). Also, calculated the average annual mass of pollutant lost in CSOs using Event Mean Concentration. Finally, this study presented a decision of storage volume for CSOs reduction and water quality protection.

Future Climate Change Impact Assessment of Chungju Dam Inflow Considering Selection of GCMs and Downscaling Technique (GCM 및 상세화 기법 선정을 고려한 충주댐 유입량 기후변화 영향 평가)

  • Kim, Chul Gyum;Park, Jihoon;Cho, Jaepil
    • Journal of Climate Change Research
    • /
    • v.9 no.1
    • /
    • pp.47-58
    • /
    • 2018
  • In this study, we evaluated the uncertainty in the process of selecting GCM and downscaling method for assessing the impact of climate change, and influence of user-centered climate change information on reproducibility of Chungju Dam inflow was analyzed. First, we selected the top 16 GCMs through the evaluation of spatio-temporal reproducibility of 29 raw GCMs using 30-year average of 10-day precipitation without any bias-correction. The climate extreme indices including annual total precipitation and annual maximum 1-day precipitation were selected as the relevant indices to the dam inflow. The Simple Quantile Mapping (SQM) downscaling method was selected through the evaluation of reproducibility of selected indices and spatial correlation among weather stations. SWAT simulation results for the past 30 years period by considering limitations in weather input showed the satisfactory results with monthly model efficiency of 0.92. The error in average dam inflow according to selection of GCMs and downscaling method showed the bests result when 16 GCMs selected raw GCM analysi were used. It was found that selection of downscaling method rather than selection of GCM is more is important in overall uncertainties. The average inflow for the future period increased in all RCP scenarios as time goes on from near-future to far-future periods. Also, it was predicted that the inflow volume will be higher in the RCP 8.5 scenario than in the RCP 4.5 scenario in all future periods. Maximum daily inflow, which is important for flood control, showed a high changing rate more than twice as much as the average inflow amount. It is also important to understand the seasonal fluctuation of the inflow for the dam management purpose. Both average inflow and maximum inflow showed a tendency to increase mainly in July and August during near-future period while average and maximum inflows increased through the whole period of months in both mid-future and far-future periods.