• Title/Summary/Keyword: Anion-exchange

Search Result 685, Processing Time 0.024 seconds

Permeability of anion-exchange membrane for Cl- ions. Dialysis of hydrochloride acid in the presence of nickel chloride

  • Palaty, Zdenek;Bendova, Helena
    • Membrane and Water Treatment
    • /
    • v.1 no.1
    • /
    • pp.39-47
    • /
    • 2010
  • Using a conventional two-compartment cell with stirrers the separation of an aqueous solution of HCl-$NiCl_2$ by an anion-exchange membrane Neosepta-AFN was investigated. The dialysis process was characterized by the permeability coefficient of the membrane towards to $Cl^-$ ions. This quantity was determined by the numerical integration of equations, which describe the time dependence of the total concentration of $Cl^-$ ions in compartment initially filled with stripping agent (water), combined with an optimizing procedure. The analysis of the experimental results showed that this permeability coefficient is a satisfactory characteristic for the process studied. It can be graphically correlated with the initial acid and initial salt concentrations in the compartment initially filled with acid+salt mixture.

A SIMPLE AND QUANTITATIVE DETERMINATION OF PU ISOTOPES IN SOIL SAMPLES

  • Lee, Myung-Ho;Choi, Geun-Sik;Chung, Kun-Ho;Cho, Young-Hyun;Lee, Chang-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.3
    • /
    • pp.191-195
    • /
    • 2001
  • An accurate and simple analytical technique for low levels of fallout Pu in the environment was developed using an anion exchange resin. To develop the reliable determination of Pu isotopes in soil samples, decomposition of soil matrix, plutonium oxidation state adjustment on the anion exchange column and source preparation of Pu isotopes have been carried out. The optimum method of Pu isotopes with an anion exchange has been validated by application to IAEA-Reference soils.

  • PDF

Step-wise Anion-Exchange in Layered Double Hydroxide Using Solvothermal Treatment

  • Lee, Jong-Hyeon;Rhee, Seog-Woo;Jung, Duk-Young
    • Bulletin of the Korean Chemical Society
    • /
    • v.26 no.2
    • /
    • pp.248-252
    • /
    • 2005
  • Synthetic layered double hydroxides (LDHs), [$Mg_4Al_2(OH)_{12}]CO_3{\cdot}nH_2O$, were prepared in the submicron size of plate-like polycrystals. Anion-exchange reactions with various linear dicarboxylic acids were performed to produce LDH/organic hybrid materials by solvothermal treatment in toluene. X-ray powder diffraction spectra for the products indicated that the interlayer spacings of LDHs remarkably changed, up to 20 $\AA$ when 1,10-decanedicarboxylic acid anions were intercalated as an organic guest. Dicarboxylates-LDHs samples could be also re-exchanged consecutively with other dicarboxylic acids or carbonate without serious destruction of layer structure under the scanning electron microscopic observation.

Purification of Odontoglossum Ringspot Virus by DEAE-Cellulose Chromatography (DEAE 셀루로오즈 컬럼 크로마토그래피 기법에 의한 Odontoglossum 윤문 바이러스의 정제)

  • 이철호;박종오;정효원;나용준
    • Korean Journal Plant Pathology
    • /
    • v.14 no.6
    • /
    • pp.559-562
    • /
    • 1998
  • Odontoglossum ringspot virus (ORSV) was finally purified from ORSV-infected orchid plants by diethylaminoethyl (DEAE) cellulose anion exchange column chromatography. The virus was reliably eluted by potassium chloride at the concentration from 0.1 M to 0.13 M. Partial purification was done by solubilization with Triton X-100 (allkylphenoxypolyethoxy ethanol) and precipitation with polyethylene glycol (PEG; MW 8,000). The finally purified ORSV represented one distinct homogeneous band and the molecular weight of its capsid protein was about 17,500 Dalton in electrophoretic analysis. Electron microscopy showed not only intact particles ranged from 280 nm to 340 nm in length, but also segmented particles that final 140 nm to 220 nm and even disks. Enzyme-linked immunosorbent assay (ELISA) showed that final yield was 12 mg/100 g of the infected leaves. Bioassay demonstrated that the purified ORSV had the normal infectivity to orchid plants and Nicotiana glutionsa. Based on these data, anion exchange column chromatography could be efficiently applied to the purification of ORSV and other viruses similar to ORSV.

  • PDF

Separation of Rare Earth Elements in Monazite Sand by Anion Exchange Resin (음이온교환수지에 의한 모나자이트중 희토류원소의 분리)

  • Ki-Won Cha;Joung-Hae Lee;Young-Gu Ha
    • Journal of the Korean Chemical Society
    • /
    • v.24 no.3
    • /
    • pp.239-244
    • /
    • 1980
  • An anion exchange method for separating the individual rare earth elements in monazite into enriched fractions has been developed. The complexed rare earth ions with EDTA at pH 8.4 pass through the anion resin bed. The absorption order of the complexed ions was in accord with that of the stability constants of the complexes. The elution of a mixture of all the rare earths through an ion-exchange bed with an ammonia-buffered solution of EDTA indicated that this chelating agent is as effective for separating the light rare earths. The separation results of each ion obtained from their elution fractions are 55% to 98%.

  • PDF

Tracing Resistances of Anion Exchange Membrane Water Electrolyzer during Long-term Stability Tests

  • Niaz, Atif Khan;Lee, Woong;Yang, SeungCheol;Lim, Hyung-Tae
    • Journal of Electrochemical Science and Technology
    • /
    • v.12 no.3
    • /
    • pp.358-364
    • /
    • 2021
  • In this study, an anion exchange membrane water electrolysis (AEMWE) cell was operated for ~1000 h at a voltage bias of 1.95 V. Impedance spectra were regularly measured every ~ 100 h, and changes in the ohmic and non-ohmic resistance were traced as a function of time. While there was relatively little change in the I-V curves and the total cell resistance during the long-term test, we observed various electrochemical phenomena in the cell: 1) initial activation with a decrease in both ohmic and non-ohmic resistance; 2) momentary and non-permanent bubble resistance (non-ohmic resistance) depending on the voltage bias, and 3) membrane degradation with a slight increase in the ohmic resistance. Thus, the regular test protocol used in this study provided clear insights into the performance degradation (or improvement) mechanism of AEMWE cells.

Stability Tests on Anion Exchange Membrane Water Electrolyzer under On-Off Cycling with Continuous Solution Feeding

  • Niaz, Atif Khan;Lim, Hyung-Tae
    • Journal of Electrochemical Science and Technology
    • /
    • v.13 no.3
    • /
    • pp.369-376
    • /
    • 2022
  • In this study, the stability of an anion exchange membrane water electrolyzer (AEMWE) cell was evaluated in an on-off cycling operation with respect to an applied electric bias, i.e., a current density of 500 mA cm-2, and an open circuit. The ohmic and polarization resistances of the system were monitored during operation (~800 h) using electrochemical impedance spectra. Specific consideration was given to the ohmic resistance of the cell, especially that of the membrane under on-off cycling conditions, by consistently feeding the cell with KOH solution. Owing to an excess feed solution, a momentary increase in the polarization resistance was observed immediately after the open-circuit. The excess feed solution was mostly recovered by subjecting the cell to the applied electric bias. Stability tests on the AEMWE cell under on-off cycling with continuous feeding even under an open circuit can guarantee long-term stability by avoiding an irreversible increase in ohmic and polarization resistances.

Cation exchange membrane and anion exchange membrane aided electrolysis processes for hypochlorite generation

  • Seong K. Kim;Dong-Min Shin;Ji Won Rhim
    • Membrane and Water Treatment
    • /
    • v.14 no.2
    • /
    • pp.55-63
    • /
    • 2023
  • In this study, the influence of different IEMs (ion exchange membranes) to performance of the hypochlorite electrolysis unit with Cl2 recovery stream was investigated. More specifically, Nafion 117-a representative cation exchange membrane (CEM)-and aminated polypheylene oxide (APPO)-an anion exchange membrane (AEM)-were installed in the hypochlorite electrolysis unit, and the performance and the energy efficiency of the units were evaluated and compared. Regardless of whether CEM (Nafion 117) or AEM (APPO) was installed, the rate of hypochlorite generation was increased (by up to 24.3% and 22.2% for Nafion 117 and APPO, respectively) compared with the unit without an IEM. On the other hand, the power efficiency and the optimum operation condition of hypochlorite production units seem to depend on the conductivity and stability of the installed IEM. As the result, between Nafion 117 and APPO, higher performance and efficiency were achieved with Nafion 117, due to excellent conductivity and stability of the membrane.

Speciation of Cd, Cu and Zn in Sewage Sludge-Treated Soils Incubated under Aerobic and Anaerobic Conditions

  • Lee, Sang-Mo;Cho, Chae-Moo;Yoo, Sun-Ho
    • Journal of Applied Biological Chemistry
    • /
    • v.42 no.2
    • /
    • pp.85-91
    • /
    • 1999
  • The incubation study was conducted under aerobic and anaerobic conditions to study the release of the kinetically labile forms (i. e. chelating ion or anion forms) of Cd, Cu and Zn in sludge-untreated soil ("Control"), sludge 50 and $100dry\;Mg\;ha^{-1}$ treated soils ("Soil-Sludge mixtures"), and sewage sludge ("Sludge"). The chelating ion and anion exchange membranes were embedded into the samples and incubated for 16 weeks under aerobic and anaerobic condition. The total amounts of chelating ion or anionic forms of Cd were too little to be measured during both aerobic and anaerobic incubation. On the other hand, the total amounts of chelating ion or anionic forms of Cu and Zn slightly increased throughout the incubation period under both incubation conditions. For "Control" and "Soil-Sludge mixtures" treatments, the total amounts of Cu and Zn in chelating ion and anion exchange membrane were little difference between aerobic and anaerobic condition, and the total amounts of chelating ion form of Cu and Zn were not different from the those of anionic form of Cu and Zn. However, for "Sludge" treatment, the total amounts of Cu and Zn in anion and chelating ion exchange membrane were greater under aerobic condition than under anaerobic condition, and the total amounts of chelating ion form of Cu and Zn were greater than those of anion form of Cu and Zn under both incubation conditions.

  • PDF

Separation and Recovery of Uranium from Korean Monazite Sand by Ion-Exchange resin (이온교환수지에 의한 모나자이트중 우라늄의 분리, 회수에 관한 연구)

  • Young Gu Ha
    • Journal of the Korean Chemical Society
    • /
    • v.27 no.5
    • /
    • pp.361-367
    • /
    • 1983
  • The selective separation and the quantitative recovery of uranium from Korean monazite sand have been studied by anion-exchange chromatography. It has been shown that method of anion-exchange chromatography under controlled conditions of elution can be applied to the production of relatively high purity of Uranium Oxide from monazite sand. Under the optimum separation conditions, the recoveries from standard sample were up to 99.3% as $U_3O_8$ on sulfate form anion resin bed and 99.2% as $U_2O_3{\cdot}P_2O_7$ on phosphate form anion resin bed. The possibility of recovering uranium from the monazite sulfate solution using a strong base anion exchange resin-Amberlite IRA-900. Uranium was successfully recovered about 92 percent. Phosphate ion did not seem to interfere with the process.

  • PDF